• Title/Summary/Keyword: assessment in science

Search Result 8,356, Processing Time 0.038 seconds

A Study of Factors Associated with Software Developers Job Turnover (데이터마이닝을 활용한 소프트웨어 개발인력의 업무 지속수행의도 결정요인 분석)

  • Jeon, In-Ho;Park, Sun W.;Park, Yoon-Joo
    • Journal of Intelligence and Information Systems
    • /
    • v.21 no.2
    • /
    • pp.191-204
    • /
    • 2015
  • According to the '2013 Performance Assessment Report on the Financial Program' from the National Assembly Budget Office, the unfilled recruitment ratio of Software(SW) Developers in South Korea was 25% in the 2012 fiscal year. Moreover, the unfilled recruitment ratio of highly-qualified SW developers reaches almost 80%. This phenomenon is intensified in small and medium enterprises consisting of less than 300 employees. Young job-seekers in South Korea are increasingly avoiding becoming a SW developer and even the current SW developers want to change careers, which hinders the national development of IT industries. The Korean government has recently realized the problem and implemented policies to foster young SW developers. Due to this effort, it has become easier to find young SW developers at the beginning-level. However, it is still hard to recruit highly-qualified SW developers for many IT companies. This is because in order to become a SW developing expert, having a long term experiences are important. Thus, improving job continuity intentions of current SW developers is more important than fostering new SW developers. Therefore, this study surveyed the job continuity intentions of SW developers and analyzed the factors associated with them. As a method, we carried out a survey from September 2014 to October 2014, which was targeted on 130 SW developers who were working in IT industries in South Korea. We gathered the demographic information and characteristics of the respondents, work environments of a SW industry, and social positions for SW developers. Afterward, a regression analysis and a decision tree method were performed to analyze the data. These two methods are widely used data mining techniques, which have explanation ability and are mutually complementary. We first performed a linear regression method to find the important factors assaociated with a job continuity intension of SW developers. The result showed that an 'expected age' to work as a SW developer were the most significant factor associated with the job continuity intention. We supposed that the major cause of this phenomenon is the structural problem of IT industries in South Korea, which requires SW developers to change the work field from developing area to management as they are promoted. Also, a 'motivation' to become a SW developer and a 'personality (introverted tendency)' of a SW developer are highly importantly factors associated with the job continuity intention. Next, the decision tree method was performed to extract the characteristics of highly motivated developers and the low motivated ones. We used well-known C4.5 algorithm for decision tree analysis. The results showed that 'motivation', 'personality', and 'expected age' were also important factors influencing the job continuity intentions, which was similar to the results of the regression analysis. In addition to that, the 'ability to learn' new technology was a crucial factor for the decision rules of job continuity. In other words, a person with high ability to learn new technology tends to work as a SW developer for a longer period of time. The decision rule also showed that a 'social position' of SW developers and a 'prospect' of SW industry were minor factors influencing job continuity intensions. On the other hand, 'type of an employment (regular position/ non-regular position)' and 'type of company (ordering company/ service providing company)' did not affect the job continuity intension in both methods. In this research, we demonstrated the job continuity intentions of SW developers, who were actually working at IT companies in South Korea, and we analyzed the factors associated with them. These results can be used for human resource management in many IT companies when recruiting or fostering highly-qualified SW experts. It can also help to build SW developer fostering policy and to solve the problem of unfilled recruitment of SW Developers in South Korea.

The Comparative Assessment of the KVA and Dynamic Stereoacuity (동적시력(KVA)과 동적 입체시의 비교 평가)

  • Kim, Young-Cheong;Shim, Hyun-Suk;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.519-525
    • /
    • 2014
  • Purpose: On this study, we investigated the relationship between the kinetic visual acuity (KVA) and the dynamic stereoacuity and the effects of anisometropia with measuring KVA and the dynamic stereoacuity. Methods: For 63 adults (male 30, female 33), KVA and the dynamic stereoacuity were measured by using the kinetic visual acuity tester (KOWA AS-4A) and the Howard-Dolman test (H-D test) at distance 2.5 m after conducted full correction of subjects' refractive error respectly. Results: The means of KVA were $0.49{\pm}0.25$ for total subjects, $0.58{\pm}0.26$ for male, $0.40{\pm}0.22$ for female, and LogMAD (Log minimum angle of displacement) dynamic stereoacuities were $1.27{\pm}0.44$($28.44{\pm}25.03sec$ of arc) for total subjects, $1.28{\pm}0.44$($28.23{\pm}23.34sec$ of arc) for male, $1.27{\pm}0.45$($28.63{\pm}26.83sec$ of arc) for female. KVA showed a statistically significant difference between male and female (p=0.00), but dynamic stereoacuity was no significant difference (p=0.97). No significant correlation was present between KVA and dynamic stereoacuity (r=0.03). Also there were no significant differences in the dynamic stereoacuity of the three group which were classified according to the low, middle, high range of KVA (p=0.99). The anisometropia were less than 1 D and over 1 D when divided into two groups, KVA and dynamic stereoacuity showed no significant difference between each (p=0.11, p=0.99). There was no significant correlation between anisometropia and KVA (r=0.33), dynamic stereoacuity (r=0.18) but the correlation between KVA and anisometropia revealed more higer than between dynamic stereoacuity and anisometropia. Conculsions: The KVA for adults showed a significant difference between male and female and male was higher than female for KVA. The dynamic stereoacuity due to the KVA, the KVA and dynamic stereoacuity due to anisometropia were not significant differences between each and also were not great correlations.

Cross-cultural Adaptation and Psychometric Evaluation of the Korean Version of the A-ONE (한국판 일상생활활동중심 작업기반 신경행동평가(A-ONE)의 개발 및 평가)

  • Kang, Jaewon;Park, Hae Yean;Kim, Jung-Ran;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.10 no.2
    • /
    • pp.109-128
    • /
    • 2021
  • Objective : The purpose of this study was to develop a Korean version of the Activities of Daily Living (ADL)-focused Occupation-Based Neurobehavioral Evaluation (A-ONE) through cross-cultural adaptation and examine its validity and reliability. Methods : This study translated the A-ONE into Korean and performed cross-cultural adaptation for the Korean population. After the development of the Korean version of the A-ONE, cross-cultural and concurrent validities were analyzed. Internal consistency, test-retest reliability, and inter-rater reliability were also evaluated. Results : We adapted three items to the Korean culture. The Korean version of the A-ONE showed high cross-cultural validity with a content validity index (I-CVI) >0.9. It correlated with the Functional Independence Measure (FIM) (r=0.52-0.77, p<0.001), except for communication. Cronbach's α was 0.58-0.93 for the functional independence scale (FI) and 0.42-0.93 for the neurobehavioral specific impairment subscale (NBSIS). Intraclass correlation coefficients (ICCs) indicated high test-retest and inter-rater reliability for FI (ICC=0.79-1.00 and 0.75-1.00, respectively) and NBSIS (ICC=0.74-1.00 and 0.72-1.00, respectively). Conclusion : The Korean version of the A-ONE is well adapted to the Korean culture and has good validity and reliability. It is recommended to evaluate ADL performance skills and neurobehavioral impairments simultaneously in Korea.

Measurement of Bone mineral density According to Middle aged Women with Low Back Pain (중년여성의 요통에 따른 골밀도 측정)

  • Kang, Jeom-Deok;Kim, Jong-Bong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.7 no.1
    • /
    • pp.5-28
    • /
    • 2001
  • Objectives: The objective of this study was to investigate analysis of bone mineral density according to Women with low back pain women. Methods: The data were collected from women who visited Physical Examination Center of a Catholic university hospital located in Daegu. Questionnaires were completed by 50 women during the period from July 20, 2000 to January 12, 2001. The sample was divided into three groups(the normal group of 16 cases and the osteopenia group of 12cases and the osteoporosis group of 22 cases). Bone mineral density(BMD) of lumbar spine was measured using energy absorptiometry. Results: The bone mineral density of the lumbar spine decreased with aging. The bone mineral density of the lumbar spine decreased with the serum Calcium and Phosphorus and Alkaline phosphatase increased. The mean bone mineral density of the lumbar spine of healthy women in age(50~59) was 0.87g/$cm^2$, the lumbar spine of women with low back pain in age(50~59) was 0.77g/$cm^2$. In the multiple regression of risk factors to bone mineral density(BMD) of lumbar spine were correlated with age, marriage existence, exercise time, the loving food of taste, calcium, bone mineral density standard T scores(p<0.05). The experience for LBP increased as weight increased(Odds ratio=999.000). The experience for LBP increased as number of Exercise decreased(Odds ratio=999.000). The experience for LBP increased as menopause existence increased(Odds ratio=999.000). The experience for LBP increased as serum Calcium and Phosphorus increased (Odds ratio=999.000). however all four variables had significant no relationship. The correlation in variables in relation to low back pain and bone mineral density, age showed contra-correlation with low back pain existence, Alkaline phosphatase(p<0.01). Weight showed contra-correlation with body mass index(BMI)(p<0.01). Exercise time showed correlation with number of exercise(p<0.01). The loving food of taste showed contra-correlation with Alkaline phosphatase(p<0.05). Bone mineral density showed correlation with menopause existence(p<0.05). Conclusions: Results from this study indicated that a statistically significant association between bone mineral density of the lumbar spin and age, marriage existence, exercise time, the loving food of taste, calcium, bone mineral density standard T scores. In logistic regression test, there were no related variables. The combination of bone mineral density measurement and assessment of the bone turnover rate by measuring biochemical would be helpful for the treatment of patients with risks of osteoporosis. The more precise study for risk factors to osteoporosis is essential.

  • PDF

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

An Analytical Study on the Stem-Growth by the Principal Component and Canonical Correlation Analyses (주성분(主成分) 및 정준상관분석(正準相關分析)에 의(依)한 수간성장(樹幹成長) 해석(解析)에 관(關)하여)

  • Lee, Kwang Nam
    • Journal of Korean Society of Forest Science
    • /
    • v.70 no.1
    • /
    • pp.7-16
    • /
    • 1985
  • To grasp canonical correlations, their related backgrounds in various growth factors of stem, the characteristics of stem by synthetical dispersion analysis, principal component analysis and canonical correlation analysis as optimum method were applied to Larix leptolepis. The results are as follows; 1) There were high or low correlation among all factors (height ($x_1$), clear height ($x_2$), form height ($x_3$), breast height diameter (D. B. H.: $x_4$), mid diameter ($x_5$), crown diameter ($x_6$) and stem volume ($x_7$)) except normal form factor ($x_8$). Especially stem volume showed high correlation with the D.B.H., height, mid diameter (cf. table 1). 3) (1) Canonical correlation coefficients and canonical variate between stem volume and composite variate of various height growth factors ($x_1$, $x_2$ and $x_3$) are ${\gamma}_{u1,v1}=0.82980^{**}$, $\{u_1=1.00000x_7\\v_1=1.08323x_1-0.04299x_2-0.07080x_3$. (2) Those of stem volume and composite variate of various diameter growth factors ($x_4$, $x_5$ and $x_6$) are ${\gamma}_{u1,v1}=0.98198^{**}$, $\{{u_1=1.00000x_7\\v_1=0.86433x_4+0.11996x_5+0.02917x_6$. (3) And canonical correlation between stem volume and composite variate of six factors including various heights and diameters are ${\gamma}_{u1,v1}=0.98700^{**}$, $\{^u_1=1.00000x_7\\v1=0.12948x_1+0.00291x_2+0.03076x_3+0.76707x_4+0.09107x_5+0.02576x_6$. All the cases showed the high canonical correlation. Height in the case of (1), D.B.H. in that of (2), and the D.B.H, and height in that of (3) respectively make an absolute contribution to the canonical correlation. Synthetical characteristics of each qualitative growth are largely affected by each factor. Especially in the case of (3) the influence by the D.B.H. is the most significant in the above six factors (cf. table 2). 3) Canonical correlation coefficient and canonical variate between composite variate of various height growth factors and that of the various diameter factors are ${\gamma}_{u1,v1}=0.78556^{**}$, $\{u_1=1.20569x_1-0.04444x_2-0.21696x_3\\v_1=1.09571x_4-0.14076x_5+0.05285x_6$. As shown in the above facts, only height and D.B.H. affected considerably to the canonical correlation. Thus, it was revealed that the synthetical characteristics of height growth was determined by height and those of the growth in thickness by D.B.H., respectively (cf. table 2). 4) Synthetical characteristics (1st-3rd principal component) derived from eight growth factors of stem, on the basis of 85% accumulated proportion aimed, are as follows; Ist principal component ($z_1$): $Z_1=0.40192x_1+0.23693x_2+0.37047x_3+0.41745x_4+0.41629x_5+0.33454x_60.42798x_7+0.04923x_8$, 2nd principal component ($z_2$): $z_2=-0.09306x_1-0.34707x_2+0.08372x_3-0.03239x_4+0.11152x_5+0.00012x_6+0.02407x_7+0.92185x_8$, 3rd principal component ($z_3$): $Z_3=0.19832x_1+0.68210x_2+0.35824x_3-0.22522x_4-0.20876x_5-0.42373x_6-0.15055x_7+0.26562x_8$. The first principal component ($z_1$) as a "size factor" showed the high information absorption power with 63.26% (proportion), and its principal component score is determined by stem volume, D.B.H., mid diameter and height, which have considerably high factor loading. The second principal component ($z_2$) is the "shape factor" which indicates cubic similarity of the stem and its score is formed under the absolute influence of normal form factor. The third principal component ($z_3$) is the "shape factor" which shows the degree of thickness and length of stem. These three principal components have the satisfactory information absorption power with 88.36% of the accumulated percentage. variance (cf. table 3). 5) Thus the principal component and canonical correlation analyses could be applied to the field of forest measurement, judgement of site qualities, management diagnoses for the forest management and the forest products industries, and the other fields which require the assessment of synthetical characteristics.

  • PDF