• Title/Summary/Keyword: ashing

Search Result 100, Processing Time 0.027 seconds

The role of matrix modifier and for the determination of cadmium in blood by graphite furnace atomic absorption spectrometry (흑연로 원자흡수분광법에 의한 혈중 카드뮴 분석시 매트릭스 개선제(matrix modifier)의 역할)

  • Yoo, Kwang-Sik;Kim, Chang-Bok;Kwon, Jin-Kee
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 1995
  • The low concentration of cadmium in the whole-blood was determined by graphite furnace atomic absorption spectrometry(GFAAS) after the sample was diluted five-fold by 1% Triton X-100, 2% $(NH_4)_2HPO_4$ as matrix modifier and pyrocoated graphite tube with L'vov platform was tried remove the interferences of blood matrix and reduce the loss of volatility of cadmium at higher ashing temperature($600^{\circ}C$). The criteria for evaluating the accuracy and precision of this analysis was confirmed by analysis of interlaboratory comparison(Japan) and NIST SRM No. 909(Cd in Serum). The limit of the determination for cadium was 0.1ng/ml and the relative standard deviation(RSD) at 1.0ng/ml level was about 10% for the GFAAS.

  • PDF

Evaluation of Accuracy and Precision of Analysis of Metals with Polyvinyl Chloride Membrane Filters (PVC 여과지를 이용한 금속 분석방법에 대한 정확도와 정밀도 평가)

  • Byun, Seong-Uk;Choi, Sangjun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.1
    • /
    • pp.48-57
    • /
    • 2016
  • Objectives: This study was conducted to evaluate the accuracy and precision of airborne metal analysis using polyvinyl chloride(PVC) membrane filter by pretreatment methods. Methods: A total of 75 spiked PVC samples for Cr, Fe and Mn ranged from 6 ug/sample to 40 ug/sample were used to evaluate recovery rates for three pretreatment methods: acid extraction, hot plate ashing and microwave digestion. For Mn, an additional 75 spiked mixed cellulose ester(MCE) membrane filters were analysed to compare the recovery rates of PVC samples. All samples were analysed with an inductively coupled plasma optical emission spectrometer(ICP-OES) and manganese samples were additionally analyzed by atomic absorption spectrometer(AAS). Results: The overall mean recovery rates of PVC samples for Cr, Fe and Mn were 90% or higher regardless of pretreatment methods, but there were statistically significant differences in recovery rates for Cr(p<0.05) and Mn(p<0.01) samples by pretreatment methods. The biases and the coefficient variations of PVC samples for three metals pretreated with three kinds of pretreatment methods ranged from 1.7% to 4.7% and from 1.6% to 6.5%, respectively. The manganese PVC samples pretreated by microwave digestion and analyzed with ICP-OES had the lowest bias at 1.9% and also showed lower bias than the bias for MCE samples, 2.7%. Conclusions: In order to accurately analyze the metals sampled with PVC membrane filters, microwave digestion and ICP-OES can be recommended.

Direct Determination Method of Antimony in High Purity Copper Metal by Graphite Furnace Atomic Absorption Spectrometry (흑연로 원자 흡수흡광법에 의한 고순도 구리 합금중의 안티몬의 직접 분석 방법)

  • Yoo, K.S;Kyung, J.D;Kwon, J.G;Lee, J.J
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.4
    • /
    • pp.252-256
    • /
    • 1995
  • A study was carried out for the development of direct determination of antimony in high purity copper metal without preseparation. The large excess of copper seemed to be performed as the matrix modifier to enhance the absorbance of antimony in copper metal. Sensitivity enhancement of Sb was obtained at the condition of the ashing temperature of $600^{\circ}C(20s){\sim}700^{\circ}C(10s)$ rather than $1000^{\circ}C(20s){\sim}1100^{\circ}C(10s)$, and the atomization temperature of $2200^{\circ}C.$ The operating pressure of argon gas was readjusted to the optimum condition at 2.0 kg/$cm^2.$ The linearity of the Sb calibration graph could be obtained in the range of 20 ppb up to 200 ppb Sb in existence of 5,000 ppm Cu with the coefficient of variation of about 5%.

  • PDF

Fabrication of Nickel Oxide Film Microbolometer Using Amorphous Silicon Sacrificial Layer (비정질 실리콘 희생층을 이용한 니켈산화막 볼로미터 제작)

  • Kim, Ji-Hyun;Bang, Jin-Bae;Lee, Jung-Hee;Lee, Yong Soo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.379-384
    • /
    • 2015
  • An infrared image sensor is a core device in a thermal imaging system. The fabrication method of a focal plane array (FPA) is a key technology for a high resolution infrared image sensor. Each pixels in the FPA have $Si_3N_4/SiO_2$ membranes including legs to deposit bolometric materials and electrodes on Si readout circuits (ROIC). Instead of polyimide used to form a sacrificial layer, the feasibility of an amorphous silicon (${\alpha}-Si$) was verified experimentally in a $8{\times}8$ micro-bolometer array with a $50{\mu}m$ pitch. The elimination of the polyimide sacrificial layer hardened by a following plasma assisted deposition process is sometimes far from perfect, and thus requires longer plasma ashing times leading to the deformation of the membrane and leg. Since the amorphous Si could be removed in $XeF_2$ gas at room temperature, however, the fabricated micro-bolomertic structure was not damaged seriously. A radio frequency (RF) sputtered nickel oxide film was grown on a $Si_3N_4/SiO_2$ membrane fabricated using a low stress silicon nitride (LSSiN) technology with a LPCVD system. The deformation of the membrane was effectively reduced by a combining the ${\alpha}-Si$ and LSSiN process for a nickel oxide micro-bolometer.

Contents of Cr and Co in Some Fisheries Caught in the West Coast (서해안지역 어패류의 크롬(Cr)과 코발트(Co) 함량)

  • Kim, Ae-Jung;Kim, Sun Yeou;Lee, Won-Chu
    • Analytical Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.29-35
    • /
    • 1998
  • This study was performed to assess the levels of the Cr and Co in fisheries caught from the some areas of west coast in Korea. The samples were 26 kinds of fishes, 19 kindly of Mollusca and 3 kinds of Crustacea. They were ashed with 5 ml $HNO_3$ and then wet-decomposed with 10 ml of a mixture of $HNO_3:H_2SO_4:HClO_4$ (10:1:4). After ashing of samples, the amounts of Cr and Co in the samples were determined by ICP-AES analysis. The moisture content of molluscans was significantly higher than that of crustaceans (p<0.05), but there was no significant difference among fisheries in the Cr content. And the Co content of crustaceans was significantly higher than that of fishes and molluscans (p<0.001). There was no significance between contents of Cr and Co in fisheries. The Cr content of Arkshell was 422.00 ppm, which was the most amount compared with those of the other samples. And the Co in Myong-Ge was 3.78 ppm, which was the most amount. Areliscus honaleus (Cr:2.76 ppm, Co:0.97 ppm), Solen (Cr:6.56 ppm, Co:1.59 ppm) and dried barley shrimp (Cr:1.06 ppm, Co:0.90 ppm) contained great amount of Cr and Co.

  • PDF

Asbestos and Non-Asbestos Fiber Content in Lungs of Autopsied Subjects in Pohang with no Known History of Occupational Asbestos Exposure (포항지역 부검 폐조직에서 석면과 비석면 섬유농도에 관한 연구)

  • Lim, Hyun-Sul;Kim, Dong-Hoon;Sakai, Kiyoshi;Hisanaga, Naomi;Kim, Ji-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.4
    • /
    • pp.477-483
    • /
    • 2000
  • Objectives : To obtain reference values for the pulmonary asbestos and non-asbestos fiber contents of residents in Korea and to compare them with similar results from Japan. Methods : The autopsied lung specimens from 22 deceased people (20 males and 2 females) in Pohang, without any known occupational history of asbestos exposure, were analyzed for incidence of asbestos and non-asbestos fibers by transmission electron microscopy with energy dispersive X-ray analysis after using low temperature ashing procedures. Results : Chrysotite fiber (46.2%) was the major fiber type found in the lungs of the subjects. The asbestos fiber concentrations found in males and females were $0.09\times10^6$ fiberss(g of dry lungs) and $0.30\times10^6$ fibers/(g of dry lungs), respectively, showing a geometric mean concentration $0.09\times10^6$ fibers/(g of dry lung tissue), due to the predominance of males in the sample. The non-asbestos fiber contents in males and females were $4.61\times10^6$ fibers/(g of dry lungs) and $17.79\times10^6$ fibers/(g of dry lungs), respectively, with a geometric mean concentration $5.21\times10^6$ fibers/(g of dry lung tissue). Conclusions : Residents in Pohang had significantly lower levels of both asbestos and non-asbestos fibers than urban residents in Korea. Furthermore, Koreans had significantly lower levels of both asbestos and non-asbestos fibers than Japanese.

  • PDF

Evaluation of the Feasibility of Eliminating Non-point Source Pollution Using Waste Sewage Sludge Bio-blocks (하수슬러지를 이용한 Bio-block의 비점오염물질 제거 가능성 평가)

  • Han, Sang Moo;Kim, Do Hyeong;Jeong, Byung Gon
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.5
    • /
    • pp.363-368
    • /
    • 2021
  • On the assessment results of the non-point source pollutant removability of bio-block using waste sewage sludge, at the reactor's initial operation stage, the removal efficiency of COD was slightly unstable. However, after the reactor was stabilized, the COD removal efficiency was higher in the reactor filled with bio-blocks compared to the reactor filled with broken stones. In terms of nitrogen and phosphorus, their removal efficiency was unstable at the initial stage of the reactor operation. This phenomenon was investigated through the bio-block elution experiments. Results indicated that nitrogen and phosphorus were eluted from the bio-blocks affecting their removal at the initial operation. Furthermore, based on elution tests conducted after the dry ashing of the waste sewage sludge, part of the nitrogen and phosphorus was eluted similar to the bio-block elution test results, although considerable amounts of nitrogen and phosphorus were reduced compared to the sludge cake. Prior to the use of the waste sewage sludge bio-blocks as a filter medium to remove non-point source pollutants, a stabilization period of 10 days was required. After the stabilization process, results showed similar characteristics as general aggregates. Moreover, to use the bio-block as a filter medium for the non-point pollutant removal, the filling ratio of 75% was the most suitable as it resulted in the highest nitrogen removal efficiency after the stabilization. The results of this study suggested that waste sewage sludge can be suitably recycled as a mixed raw material for the bio-blocks, with satisfactory application as a filter medium in artificial wetlands, stormwater runoff problems, stream water pollutants to eliminate non-point source pollutants.

Monitoring Heavy Metals in Meat and Meat Products (식육 및 그 가공품의 중금속 모니터링)

  • Hwang, Tae-Ik;Ahn, Tae-Hyun;Kim, Eun-Jung;Lee, Jung-Ah;Kang, Myoung-Hee;Jang, Young-Mi;Kim, Mee-Hye
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.525-531
    • /
    • 2011
  • This study was conducted to examine the contents of lead (Pb), cadmium (Cd), arsenic (As), and mercury (Hg) in meat and meat products in Korea. The contents of Pb, Cd, As, and Hg in 466 samples of beef, pork, chicken, duck, ham, and sausage were measured using inductively coupled plasma mass spectrometry or a mercury analyzer. Wet ashing and microwave method were compared, and the recovery and reproducibility of the microwave method were better than those of wet ashing for meat and meat products. The recovery of the microwave method was 98.1% for Pb, 104.6% for Cd, and 103.4% for As, respectively. The best result was obtained through digestion using an acid mixture ($HNO_3$/$H_2O_2$, 6:2). Hg content was measured using a mercury analyzer. As a result, the contents of Hg and Cd in samples were lower than those of Pb and As. The average contents of Pb were 0.009 mg/kg in beef, 0.010 mg/kg in pork, 0.006 mg/kg in chicken, 0.007 mg/kg in duck, 0.005 mg/kg in ham, and 0.009 mg/kg in sausage. The average Cd contents were 0.0004 mg/kg in beef, 0.0004 mg/kg in pork, 0.0005 mg/kg in chicken, 0.0012 mg/kg in duck, 0.0015 mg/kg in ham, and 0.0019 mg/kg in sausage. The average As contents were 0.016 mg/kg in beef, 0.004 mg/kg in pork, 0.021 mg/kg in chicken, 0.010 mg/kg in duck, 0.014 mg/kg in ham, and 0.018 mg/kg in sausage. The average Hg contents were 0.713 ${\mu}g/kg$ in beef, 0.902 ${\mu}g/kg$ in pork, 0.710 ${\mu}g/kg$ in chicken, 0.796 ${\mu}g/kg$ in duck, 1.141 ${\mu}g/kg$ in ham, and 1.052 ${\mu}g/kg$ in sausage. Based on the results of the National Health and Nutrition Survey 2005, the levels of dietary exposure to heavy metal contaminants in meat and meat products were compared with the provisional tolerable weekly intake(PTWI) established by the Joint FAO/WHO Expert Committee on Food Additives. The average dietary exposure of the general population from meat and meat products was 0.03-0.2% of PTWI for Pb, Cd, As, and Hg, which indicates a safe level for public health at present.

A Study on the Mineral Content of Calcium-fortified Foods in Korea (우리나라의 칼슘강화식품의 무기질 함량에 관한 연구)

  • 김욱희;김을상
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.1
    • /
    • pp.96-101
    • /
    • 2003
  • This study was done to analyze the contents of minerals, to compare the measured values of calcium and the labeled values in food labeling and to analyze the ratio of calcium to other minerals in 43 calcium-fortified Food products sold in markets in Seoul, Korea. Content of minerals such as Ca, P, Mg, Na, K, Fe, Cu, Zn was measured by atomic absorption or colorimetric method after dry-ashing or wet-ashing. The measured values of calcium were ranged 65.5~343.9% of the labeled values in 43 calcium-fortified products. In 21 calcium-fortified food products, the measured calcium values were ranged 120~160% of the labeled values, and in three drinks those were less than 80% of the labeled, which is not acceptable to the food regulation. The ratios of Ca:P were 2.63$\pm$1.99 (mean$\pm$SD) in grain Products, 1.79$\pm$0.39 in Ramyuns, 2.80$\pm$0.53 in retort pouch food products and 8.35$\pm$12.87 in drinks. The Ca:Fe ratios were 126.33$\pm$44.36 in grain products, 130.65$\pm$34.67 in Ramyuns, 120.31$\pm$71.15 in retort pouch food products and 700.25$\pm$553.70 in drinks. The ratios of Ca:Mg were 11.86$\pm$5.40 in grain products, 9.29$\pm$1.34 in Ramyuns, 9.09$\pm$2.09 in retort pouch food products and 32.50$\pm$41.35 in drinks. The P:Mg ratios were 4.11$\pm$1.54 in grain products, 4.17$\pm$0.67 in Ramyuns, 2.58$\pm$0.45 in retort pouch food Products and 2.59$\pm$2.50 in drinks. These results suggest calcium contents and the ratio of calcium contents to other minerals in calcium-fortified food products should be strictly controlled.

The Study on the Aluminum Content in Fishes Caught from Several Areas of the West Coast in Korea (수산식품 중 노인성 퇴행성 질환과 관련된 알루미늄 함량 및 그에 따른 수산식품의 이용방안에 관한 연구)

  • 김애정
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.7 no.4
    • /
    • pp.512-518
    • /
    • 1997
  • This study was performed to determine the amount of aluminum, which is one of the factors of Alzheimer's disease, In some fishes caught from some areas of the west coast in Korea. The 46 aquatic products were composed of fishes, molluscs, and salt-fermented products (jeot-gal). The 24 fishes were Hickory shad, Gobies, Pomfref, Atkafish, Flounder, Jambeng-ie Monk fish, Yellow hair tail, Mackerel, Bartailed flathead, Alaska pollack, Brown croaker, Eel, Fine-spotted flounder, Black spotted grouper, Sea-eel, Pacific saury, Areliscus honaleus, Small boil-dried anchovy, Croaker, Hair tail, Sea bream genuine, Motleystrip rainbowfish, and Bastard halibut. The 15 Molluscs were Whip-arm octopus, Sea arrow, Common squid, Han chi, Cuttle fish, Turban shell, Pond snail, Orient calm, Surf calm, Butter calm, Crib shell, Oyster, Egg cockle, Little neck calm, and Arkshell. The 7 salt-fermented products were salt-fermented Shrimp, Little neck, Oyster, Shad, Gonjeng-ie, Hqangsegi, and Squid. All of them were ashed with 5$m\ell$ HNO$_3$ and then with 10$m\ell$ ternary solution (HNO$_3$ : H$_2$SO$_4$ : HClO$_4$= 10 : 1 : 4). After ashing of the samples, the aluminum amount were measured by ICP. The aluminum amount of molluscs was significantly higher than that of fishes and salt-fermented products(p<0.01). The aluminum amount of Orient calm and Healak in molluscs were 827.70, 812.55ppm, respectively, which were the most amounts compared nth that of the other samples. But the aluminum amounts of Bartailed flathead and Sea bream, genuine In fishes were 0.98, 0.97ppm, respectively, which were the least amounts compared with that of other samples. This study was limited within 46 aquatic samples, therefore I hope there will be wider efforts to determine about auminum amount in broade range of aquatic foods for the prevention of Alzheimer's disease.

  • PDF