• Title/Summary/Keyword: aseismic capacity

Search Result 14, Processing Time 0.024 seconds

A Test on the Aseismic Capacity of a Traditional Three-bay-straw-roof House(I) : Rock Site Condition (전통 초가삼간 가옥의 내진성능 평가 실험(I) : 암반지반 조건)

  • 서정문;최인길;전영선;이종림;신재철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.4
    • /
    • pp.11-20
    • /
    • 1997
  • The aseismic capacity of a traditional three-bay-straw-roof wooden house for rock site condition is quantitatively estimated. One 1/4 scale model was tested for the Nahanni Earthquake with peak ground accelerations from 0.1g to 0.6g. The natural frequency of the wooden house in elastic range is 1.66 Hz and 2.15 Hz in longitudinal and transversal direction, respectively. Damping ratio of the house in elastic range is 7%. The horizontal acceleration response of the house is significantly reduced compared with the input motion due to the nonlinear inelastic characteristics of the Sagae-machum joint of the frame. The traditional wooden house has high aseismic capacity in the rock site condition where high frequency contents of motion are predominant.

  • PDF

Damage Assessment and Aseismic Capacity Evaluation of Existing Structures (기설구조물의 손상도 및 내진능력 평가방법)

  • 윤정방;송종걸;김유진
    • Computational Structural Engineering
    • /
    • v.11 no.3
    • /
    • pp.199-212
    • /
    • 1998
  • 본 연구에서는 기설구조물에 대한 손상도 추정기법과 내진능력평가 방법에 대하여 연구하였다. 구조물의 손상도를 추정하는 방법으로는 소수의 계측 데이터를 이용한 모드섭동법(inverse modal perturbation)을 이용하였다. 구조물의 손상은 강성행렬의 감소로 표현하여, 각 요소행렬에 대한 손상을 손상지수를 사용하여 나타내었다. 구조적 손상과 이에 기인한 고유진동 특성의 변화량과의 관계를 섭동방정식으로부터 구한 후, 이로부터 손상지수와 고유진동 특성의 변화량과의 관계를 유동하였다. 따라서 손상 전과 후에서 구조물의 고유진동수와 모드형상을 측정하여 섭동식의 해를 구함으로써 구조물의 강성행렬의 감소로 나타나는 구조물의 손상도를 추정하게 된다. 손상도 추정에 의해 평가된 강성의 변화량에 기인한 손상 후의 기설구조물의 지진응답, 내진능력과 지진손상도의 평가를 손상전과 비교하였다. 내진능력은 구조부재에서 회전연성도 능력의 경험식을 이용하여 평가하였고, 지진손상도의 평가는 가장 많이 사용되는 방법인 Park & Ang 방법을 사용하였다. 예제해석은 다른 지진하중을 받는 2층과 8층의 예제구조물에 대해서 수행하였다.

  • PDF

A Test on the Aseismic capacity of a Traditional Three-bay-straw-roof House(II): Soil Site Condition (전통 초가삼간 가옥의 내진성능 평가 실험 (II): 연약지반 조건)

  • 서정문;최인길;전영선;이종림;신재철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.4
    • /
    • pp.21-28
    • /
    • 1997
  • The aseismic capacity of a traditional three-bay-straw-roof wooden house for soft soil site condition is quantitatively estimated. One 1/4 scale model was tested for the Imperial Valley Earthquake up to failure. The natural frequency of the wooden house measured in elastic range is 1.66 Hz and 1.76 Hz in the longitudinal and transversal direction, respectively. Damping ratio of the house measured in elastic range is 7%. The peak horizontal acceleration response of the house was reduced compared with input motion due to the nonlinear inelastic characteristics of the wooden frame. The horizontal displacement response was significantly increased as the level of input motion was increased. The model was collapsed at 0.25g due to the low frequency contents of the input motion. The results of nonlinear seismic analysis were compared with the test results.

  • PDF

Development of Seismic Analysis Technique for Masonry Structure (조적식 교각의 내진해석 기법 개발)

  • 정용철;배준현;이준석;강영종
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.171-176
    • /
    • 2002
  • There are many railway structures which were designed without conidering aseismic capacity. In special, masonry structures constructed long time ago should be reviewed about their resistance to earthquake. In this paper, technique to evaluate the capacity of masonry railway bridge is tried to develop by means of FEM analysis. In general FEM analysis program, 3-D solid element is used for masonry structures and response spectrum analysis procedure is tried. In addition, 3-D solid element has material properties equivalent to mortar-brick composite body. Used FEM program is ABAQUS-CAE.

  • PDF

Damage Assessment and A seismic Capacity Evaluation of Existing Structures (기설구조물의 손상도추정 및 내진능력평가 방법에 관한 연구)

  • 윤정방;송종걸;김유진
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.414-421
    • /
    • 1998
  • The content of this paper consists of two related subjects. One is the assessment of damages in the existing structure and the other is the evaluation of seismic capacity of the structure with damage. A method is presented for damage assessment of existing structures using the modal data measured at limited points by the inverse medal perturbation technique. For efficient damage assessment, the number of the unknown probable damaged members is reduced for each damage identification by grouping the members in the large structure. The aseismic capacity is evaluated for the structure using the results of damage assessment. An example analysis is carried out for a building structure subjected to different earthquake excitations.

  • PDF

Foundation size effect on the efficiency of seismic base isolation using a layer of stone pebbles

  • Banovic, Ivan;Radnic, Jure;Grgic, Nikola
    • Earthquakes and Structures
    • /
    • v.19 no.2
    • /
    • pp.103-117
    • /
    • 2020
  • The effect of the foundation size on the efficiency of seismic base isolation using a layer of stone pebbles is experimentally investigated. Four scaled models of buildings with different stiffnesses (from very stiff to soft) were tested, each with the so-called small and large foundation, and exposed to four different accelerograms (different predominant periods and durations). Tests were conducted so that the strains in the model remained elastic and afterwards the models were tested until collapse. Each model was tested for the case of the foundation being supported on a rigid base and on an aseismic layer. Compared to the smaller foundation, the larger foundation results in a reduced rocking effect, higher earthquake forces and lower bearing capacity of the tested models, with respectable efficiency (reduced strain/stress, displacement and increase of the ultimate bearing capacity of the model) for the considered seismic base isolation compared to the foundation on a rigid base.

Seismic Capacity Evaluation of Existing Structures Incorporating Damage Assessment (구조손상을 고려한 기설구조물의 내진성능평가)

  • Song, Jong Keol;Yi, Jin Hak;Lee, Dong Guen
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.543-553
    • /
    • 2004
  • This paper covered two related subjects: the use of the inverse modal perturbation technique to assess structural damage in existing structures; and the use of a seismic capacity evaluation to assess damaged structures, with the aid of the identified structural damage. The substructural identification and the Tikhonov regularization algorithm were incorporated for efficient damage assessment of complex and large frame structures. The seismic capacity of a damaged structure was evaluated by comparing the structure's seismic responses and seismic damage indices. The effectiveness of the proposed method has been investigated through the numerical simulation study for a twenty-story frame structure with undamaged and damaged cases, and also different earthquake excitations.

Mechanics model of novel compound metal damper based on Bi-objective shape optimization

  • He, Haoxiang;Ding, Jiawei;Huang, Lei
    • Earthquakes and Structures
    • /
    • v.23 no.4
    • /
    • pp.363-371
    • /
    • 2022
  • Traditional metal dampers have disadvantages such as a higher yield point and inadequate adjustability. The experimental results show that the low yield point steel has superior energy dissipation hysteretic capacity and can be applied to seismic structures. To overcome these deficiencies, a novel compound metal damper comprising both low yield point steel plates and common steel plates is presented. The optimization objectives, including "maximum rigidity" and "full stress state", are proposed to obtain the optimal edge shape of a compound metal damper. The numerical results show that the optimized composite metal damper has the advantages such as full hysteresis curve, uniform stress distribution, more sufficient energy consumption, and it can adjust the yield strength of the damper according to the engineering requirements. In view of the mechanical characteristics of the compound metal damper, the equivalent model of eccentric cross bracing is established, and the approximate analytical solution of the yield strength and the yield displacement is proposed. A nonlinear simulation analysis is carried out for the overall aseismic capacity of three-layer-frame structures with a compound metal damper. It is verified that a compound metal damper has better energy dissipation capacity and superior seismic performance, especially for a damper with double-objective optimized shape.

Overturning of precast RC columns in conditions of moderate ground shaking

  • Kafle, Bidur;Lam, Nelson T.K.;Lumantarna, Elisa;Gad, Emad F.;Wilson, John L.
    • Earthquakes and Structures
    • /
    • v.8 no.1
    • /
    • pp.1-18
    • /
    • 2015
  • A simple method of assessing the risk of overturning of precast reinforced concrete columns is presented in this paper. The displacement-based methodology introduced herein is distinguished from conventional force-based codified methods of aseismic design of structures. As evidenced by results from field tests precast reinforced concrete columns can be displaced to a generous limit without sustaining damage and then fully recover from most of the displacement afterwards. Realistic predictions of the displacement demand of such (rocking) system in conjunction with the displacement capacity estimates enable fragility curves for overturning to be constructed. The interesting observation from the developed fragility curves is that the probability of failure of the precast soft-storey column decreases with increasing size of the column importantly illustrating the "size effect" phenomenon.

Experimental study on high gravity dam strengthened with reinforcement for seismic resistance on shaking table

  • Wang, Mingming;Chen, Jianyun;Fan, Shuli;Lv, Shaolan
    • Structural Engineering and Mechanics
    • /
    • v.51 no.4
    • /
    • pp.663-683
    • /
    • 2014
  • In order to study the dynamic failure mechanism and aseismic measure for high concrete gravity dam under earthquake, the comparative models experiment on the shaking table was conducted to investigate the dynamic damage response of concrete gravity dam with and without the presence of reinforcement and evaluate the effectiveness of the strengthening measure. A new model concrete was proposed and applied for maintaining similitude with the prototype. A kind of extra fine wires as a substitute for rebar was embedded in four-points bending specimens of the model concrete to make of reinforced model concrete. The simulation of reinforcement concrete of the weak zones of high dam by the reinforced model concrete meets the similitude requirements. A tank filled with water is mounted at the upstream of the dam models to simulate the reservoir. The Peak Ground Acceleration (PGA) that induces the first tensile crack at the head of dam is applied as the basic index for estimating the overload capacity of high concrete dams. For the two model dams with and without strengthening tested, vulnerable parts of them are the necks near the crests. The results also indicate that the reinforcement is beneficial for improving the seismic-resistant capacity of the gravity dam.