• 제목/요약/키워드: artificial tooth movement

검색결과 15건 처리시간 0.022초

A comparative study on the accuracies of resin denture bases and metal denture bases

  • Park Hwee-Woong;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.250-259
    • /
    • 2001
  • Since the late 1930s, acrylic resins have been the materials of choice for the fabrication of complete denture bases. It has excellent esthetic properties, adequate strength, low water sorption, and low solubility. But acrylic resin has disadvantage of processing shrinkage that reduces denture retention and accuracy of denture occlusion. Metals also have been used in denture base material. Metals used in denture bases display excellent strength and dimensional stability. The major disadvantages associated with metal denture bases include increased cost, difficulty in fabrication, compromised esthetic qualities, and inability to re-base. The purpose of this study is to compare the artificial tooth movements of complete dentures with resin bases and metal bases after curing, deflasking, polishing immersion in water for 1 week and 4 weeks. Twenty-four maxillary complete resin denture bases with artificial teeth were fabricated. Twelve of them were resin based and other twelve of them were metal based. Fine crosses were marked on the incisal edges of right central incisors and distobuccal cusps of be second molars. Measurements were done for the changes of distances of reference points at the time of wax denture, after deflasking after decasting after polishing after immersion in water for 1 week and 4 weeks Meaurements were done to the accuracy of 0.001mm with a measuring microscope. The results were as follows : 1. Metal base showed significantly less tooth movement than resin base after curing and decasting (p<0.01). 2. Metal base showed significantly less tooth movement than resin base after polishing (p<0.01). 3. After immersion in water for 1 week and 4 weeks, metal base showed less movement than resin base. Difference was significant for anterior-posterior distances (p<0.01), but not significant for molar-to-molar distance (p>0.01). 4. 1 week and 4 weeks of immersion failed to compensate the initial processing shrinkage of metal and resin bases (p>0.01).

  • PDF

의치주위조직(義齒周圍組織)의 기능인상(機能印象) 채득법에 의한 0$^{\circ}$ 구치(臼齒)의 Full Denture 제작법(製作法) ("A Study of Farbricating Full Denture, Which is Used Functional Imp and Zero-degree Artificial Poster Teeth")

  • 김의남
    • 대한치과기공학회지
    • /
    • 제7권1호
    • /
    • pp.33-40
    • /
    • 1985
  • When full denture is being fabricated, pronounciation, recovery of aesthetics of function and mastificatory function should be satisfies for patients. To satisfy for the function of denture, following is the difference between this new way of fabricating and formerly one of it. 1. The size of fabricating tooth which is harmony of original oral structure for patients is deaded by manufacturing labial index and artificial tongue. 2. By the use of artificial tongue and labial index, the arranges of artificial tooth is to become harmony of oral structure. 3. Formation of gingival decided functional impression which is used by impression paste, is harmony of oral structure. Therefore, this full denture can be satisfied with pronouncing oral function of recovery of aesthetics as well as mastificatory through physiological movement of oral tissue not disturbed with anything but cooperated drastically. In manufacturing of this full denture, both dentist and dental technician under cooperation need to proceed the work on the base of importance of communication.

  • PDF

A COMPARATIVE STUDY ON THE DIMENSIONAL CHANGE OF THE DIFFERENT DENTURE BASES

  • Kim, Myung-Joo;Kim, Chang-Whe
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.712-721
    • /
    • 2006
  • Statement of problem. Acrylic resin is most commonly used for denture bases. However, acrylic resin has week points of volumetric shrinkage during polymerization that reduces denture fit. The expandability of POSS (Polyhedral Oligomeric Silsesquioxane) containing polymer could be expected to reduce the polymerization shrinkage of denture bases and would increase the adaptability of the denture to the tissue. Purpose. The purpose of this study was to compare the dimensional stability in the conventional acrylic resin base, POSS-containing acrylic resin base, and metal bases. Materials and methods. Thirty six maxillary edentulous casts and dentures of different base were fabricated. Tooth movement and tissue contour change of denture after processing (resin curing, deflasking, decasting and finishing without polishing) and immersion in artificial saliva at $37^{\circ}C$ for 1 week and 4 weeks were measured using digital measuring microscope and threedimensional laser scanner. Results. The results were as follows: 1. The conventional resin group showed significant (p<0.01) dimensional change throughout the procedure (processing and immersion in artificial saliva). 2. After processing, the metal group and POSS resin group showed lower linear and 3-dimensional change than conventional resin group (p<0.01). 3. There was no statistically significant linear and 3-dimensional change after immersion for 1 week and 4 weeks in metal and POSS resin group. 4. In all groups, the midline and alveolar ridge crest area presented smaller 3-dimensional change compared with vestibule and posterior palatal seal area after processing and soaking in artificial saliva for 1 week and 4 weeks (p<0.01). Conclusion. In this study, a reinforced acrylic-based resin with POSS showed good dimensional stability.

인공타액하에서 교정선과 Bracket간의 마찰력에 대한 연구 (FRICTIONAL FORCES BETWEEN ORTHODONTIC WIRE AND BRACKET UNDER ARTIFICIAL SALIVA)

  • 고정석;양규호
    • 대한치과교정학회지
    • /
    • 제18권1호
    • /
    • pp.55-63
    • /
    • 1988
  • It has been suggested that the frictional force between bracket and arch wire may impede the tooth movement. The present study was aimed to compare and analyze the effect of wire size, type of ligation, and duration of ligation on the magnitude of frictional force between cobalt chromium wire and stainless steel bracket under the artificial saliva. The results were as follows: 1. Type of ligation and size of wire were the main influencing factor on the level of friction. 2. Stainless steel ligature generated higher frictional forces than elastomeric module. 3. The rectangular wire consistently exhibited more frictional force values than round wires, while there was no significant difference between frictional forces of round wires. 4. In elastic ligature, frictional force decreased with time. 5. Artificial saliva had no significant influence on the frictional force between cobalt chromium wire and bracket.

  • PDF

성인 구순구개열 환자에서 Multidisciplinary 치료로 기능성 교합을 형성한 증례 (Multidisciplinary Treatment Approach in a Secondary Cleft Lip and Palate Patient for Functional Occlusal Rehabilitation)

  • 이지나
    • 대한구순구개열학회지
    • /
    • 제15권1호
    • /
    • pp.29-38
    • /
    • 2012
  • A 20 year-old cleft lip and palate patient came for occlusal rehabilitation, but the constricted maxilla and early loss of posterior teeth called for an unusual treatment modalities. Distraction osteogenesis in the edentulous areas followed by artificial bone graft, dental implant along with orthodontic tooth movement were planed. Multidisciplinary treatment enabled both esthetic and functional oral rehabilitation of this patient.

  • PDF

A comparison of the elimination rate of artificial dental plaque between reciprocating- and rotating-interdental toothbrushes

  • Lim, Kun-Ok
    • 한국치위생학회지
    • /
    • 제21권1호
    • /
    • pp.17-25
    • /
    • 2021
  • Objectives: Interdental toothbrushes are made and sold in various design types and brush thicknesses. However, there is little research on which type of interdental toothbrush currently manufactured and sold on the market is the most effective in eliminating interdental plaque. Therefore, this study aims at comparing the elimination rate of artificial dental plaque between reciprocating- and rotating-types of interdental toothbrush based on the frequency of application and thickness of brush. Methods: This study focused on the effective management of dental plaque using interdental toothbrush, a recommended item for personal dental hygiene. The method was as follows: artificial dental plaque coloring was applied to the distal surface of artificial tooth #46 and the mesial surface of #47. The area was subject to reciprocal movement three and six times to eliminate artificial plaque. Results: The results showed that using a 0.7mm rotating interdental toothbrush, on the proximal surface of each molar, the elimination rates were: on the distal surface of #46, upon three applications 40.24%, upon six applications 30.41%; on the mesial surface of #47, upon three applications 44.52%, upon six applications 29.72%. Conclusions: These results showed that for rotating-type interdental toothbrushes, a high dental plaque elimination rate was observed even though many reciprocal movements were not performed.

상악전치 후방 견인시 견인 loop후방에 부여한 gable bend 양에 따른 치아이동 양상에 관한 연구 (A study on the effect of the magnitude of the gable bends on the tooth movement pattern during on-masse space closure in the maxillary dentition)

  • 전윤식;노준;정상혁;김희정
    • 대한치과교정학회지
    • /
    • 제34권1호
    • /
    • pp.33-45
    • /
    • 2004
  • 제 1소구치가 발치된 증례에서 bull loop를 견치 직후방에 제작한 후 gable bend를 어느 정도 부여할 때 전치부의 효과적인 치축조절과 후방 이동량을 극대화 할 수 있는지를 입체적으로 확인하는 것이 본 연구의 목적이다. 제 1소구치가 제거된 상악우측 인공 치조골부에 중절치부터 제 2대구치까지 실험용 치아들을 식립하였다. 그 후 bull-loop가 형성된 반쪽 호선에 $10^{\circ},\;20^{\circ},\;30^{\circ}$의 gable bend를 부여한 후 3전치를 후방 견인하여 발치공간을 폐쇄시켰고 이러한 실험과정을 각 군마다 3회씩 반복 실험하였다. 발치공간이 폐쇄된 후 실험전, 후의 교합방사선 사진상에 촬영된 전치부와 구치부의 시상면과 교합면 상에서의 각 군별 치아이동 양상을 일요인 분산분석(ANOVA)과 Scheffe 검정으로 평가한 결과 아래와 같은 결론을 얻었다. 1. Gable bend의 양이 증가할수록 전치부의 치축은 치체이동 양상을 보였으며 후방 이동량도 증가하였다. 2. Gablebend의 양이 증가할수록 구치부의 전방 이동량은 감소하였으나 수직적 압하량 및 협측 이동량은 증가하였다(p<0.001). 3. 발치공간에 인접한 견치의 원심회전과 제 2소구치의 근심회전에 의해 악궁의 조화가 이루어졌다(p<0.001).

결찰양식이 교정용 브라켓과 교정선 사이의 마찰력에 미치는 영향 (THE EFFECT OF LIGATION METHOD ON THE FRICTIONAL FORGE BETWEEN ORTHODONTIC BRACKET AND ARCHWIRE)

  • 신현정;권오원;김교한
    • 대한치과교정학회지
    • /
    • 제28권5호
    • /
    • pp.813-823
    • /
    • 1998
  • 마찰력은 치아이동시 활주이동부에 유해한 인자로 인식되어져 왔으나 치아이동에 저항하는 고정원에 있어서는 유리한 인자로 받아들여질 수 있다. 즉 마찰력이 작은 결찰법들을 이용하여 효과적인 치아이동을 도모하는 반면 마찰력이 큰 결찰법들을 이용하여 브라켓의 걸림에 의해 치아이동이 거의 일어나지 않게 하면 고정원을 강화할 수 있다. 인공타액하에서 시간경과에 따른 교정선과 브라켓 사이의 마찰력 변화, 탄성 모듈과 스테인레스 강 결찰선을 이용하여 각각 결찰양식을 달리 하였을 때의 마찰력 변화 그리고 결찰재의 재료를 달리 하였을 때의 마찰력 변화를 알아보기 위하여 .018"x.025" 슬롯의 상악 중절치용 standard edgewise twin 브라켓과 .017"x.022" 스테인레스 강 교정선을 탄성 모듈, .009" 스테인레스 강 결찰선 그리고 .012" 스테인레스 강 결찰선을 이용하여 다양하게 결찰하였다. 또한 통상적인 방법으로 결찰한 탄성 모듈 결찰군을 결찰 직후와 1주 간격으로 4주간 마찰력을 측정하여 다음과 같은 결과를 얻었다. ${\cdot}$탄성 모듈 whole tie시 시간경과에 따른 마찰력은 4주 경과시 가장 높았으나 3주, 2주, 1주, 결찰 직후간에는 통계학적으로 유의한 차이가 없었다 (p>0.n). ${\cdot}$탄성 모듈로 결찰시 마찰력은 twisting tie가 가장 높았고 double overlay tie, whole tie, half tie 순으로 나타났으나 twisting tie와 double overlay tie 간에는 통계학적으로 유의한 차이가 없었다 (p>0.05). ${\cdot}$스테인레스 강 결찰선으로 결찰시 half tie 군이 whole tie 군보다 낮은 마찰력을 보였으며 ligature tying plier로 결찰한 경우가 needle holder로 결찰한 경우보다 더 높았고 .012" 결찰선을 이용한 경우가 .009" 결찰선을 이용한 경우보다 더 높았다 (p<0.05). ${\cdot}$통상적인 방법으로 탄성 모듈과 스테인레스 강 결찰선을 이용하여 결찰한 경우 두 군간에 유의한 차이가 없었다(p>0.05).

  • PDF

시간경과에 따른 교정용 bracket과 교정선 사이의 마찰력 변화에 관한 연구 (A STUDY ON THE CHANCES OF FRICTIONAL FORCE BETWEEN BRACKET AND ORTHODONTIC WIRE WITH TIME IN ARTIFICIAL SALIVA)

  • 곽춘;김진범;손우성
    • 대한치과교정학회지
    • /
    • 제23권2호
    • /
    • pp.283-294
    • /
    • 1993
  • The friction of orthodontic appliances is recogonized to be detrimental to tooth movement. The purpose of this study was to determine the magnitude of frictional force changes between bracket$(018'\times025'\;solt)$ and orthodontic wires(stainless steel, cobalt-chromium, and $\beta-titanium$, $017'\times0.25'$ rectangular) with time. The wire was secured in the bracket slot with a elastomeric ligature. Frictional forces were measured by universal testing machine. The following conclusions were obtained. 1. The frictional forces under dry condition were greater than those in saliva. 2. The frictional forces produced by cobalt-chromium wire were less than those generated by stainless steel and $\beta-titanium$ wire. 3. The frictional forces increased progressively with time, and the amount of increase on first two weeks was greater than on last two weeks. 4. The change of frictional force under dry condition was greater than in artificial saliva.

  • PDF

두 종류의 구치직립 스프링 사용시 저항원 및 근심경사치의 동적인 치아이동 양상에 관한 연구 (An experimental study on the dynamic tooth movement of two molar uprighting springs by calorific machine)

  • 전윤식;노준
    • 대한치과교정학회지
    • /
    • 제30권3호
    • /
    • pp.273-285
    • /
    • 2000
  • 본 연구의 목적은 1200g.mm의 모멘트를 발생시키는 두 종류의 canti-lever형 구치직립 스프링 중 치관직립형(crown uprighting)과 치근직립형(root uprighting)을 Calorific machine 상에 각 각 5회씩 적용하여 나타난 저항원 및 근심경사치의 동적인 치아이동 양상을 좀더 구체적으로 비교해 보는데 있다. 열 발생 및 온도조절 장치, 실험용 치아, 그리고 실험용모델로 구성 된 Calorific machine을 이용하여 치아이동 전, 후에 얻어진 2장의 교합X-선사진 상에 X-선 불투과상으로 나타난 두 개의 임플란트를 기준 표지점으로 중첩함으로써 치아이동 전후의 시상면과 교합면 상에서의 위치변화를 확인하였다. 각 스프링의 변화량을 2회씩 계측한 결과 조사자내 동의율(intra-examiner agreement)과 조사자간 동의율(inter-examiner agreement)은 $96.54\%$$95.73\%$였으며 각 스프링의 실험 전, 후의 유의성 검증과 두 스프링간의 유의성 여부를 짝비교(Paired t-test)로 통계처리한 결과 다음과 같았다. 1. 치관직립 스프링 보다 치근직립 스프링을 사용할 때 저항원의 상실량이 원심 및 협측방향으로 크게 나타났다. 2. 치관직립 스프링 사용시 경사치 치관의 원심이동량은 ,3.29mm 였으나 치근직립 스프링은 1.68mm 였다. 3. 치관직립 스프링 사용시 경사치의 근, 원심 치근의 전방 이동량은 각각 3.91mm, 3.60mm였으나 치근직립 스프링에서는 각각 6.76mm, 6.26mm였다.

  • PDF