• Title/Summary/Keyword: artificial tears

Search Result 15, Processing Time 0.03 seconds

The Effect of Artificial Tear Components on Tear Film Stability of Dry Eyes in the Early Stage of Soft Contact Lenses Wear (소프트콘택트렌즈를 착용한 건성안의 착용초기 눈물막 안정성에 인공눈물 성분 조성이 미치는 영향)

  • Kim, So Ra;Lim, Jung A;Jung, Ji Hye;Byun, Hyun Young;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.191-201
    • /
    • 2016
  • Purpose: In the present study, the effect of artificial tears with different ingredients on tear film stability and subjective symptoms of dry eyes in the early stage of soft contact lenses wear was investigated. Methods: The three kinds of artificial tears and saline solution were respectively applied onto 50 dry eyes which wore soft contact lenses made of etafilcon A. Then, non-invasive tear film break-up time (NIBUT) was measured at every five minutes for 30 minutes right after the instillation of artificial tears, and the changes in blink rate and subjective symptoms were estimated after 30 minutes from the instillations. Results: All three kinds of artificial tears increased NIBUT larger than saline. The effect of increasing NIBUT immediately after the instillation of artificial tears was the largest when the artificial tear containing viscosity enhancer was used. The duration time of the effect was the longest when the artificial tear having both surfactant and viscosity enhancer was applied. The blink rate was not significantly changed when both artificial tears and saline solution were instilled. Subjective symptoms were significantly improved by the instillation of both artificial tears and saline solution and dryness, irritation, tiredness, stiffness, dazzling were improved by the use of most solutions. However, the subjective symptoms were rebounded to the level before the instillation of artificial tears after 30 minute-instillation. Conclusions: It was revealed that both artificial tears and saline solution could improve the subjective symptoms of dry eye in the early stage of soft contac lenses however, the effect of these solutions on the tear film stability was different according to the components. From the results, it is suggested that the proper selection of artificial tears is necessary for the improvement of dry eye symptoms at the early stage of soft contact lenses wear in dry eye.

indolent ulcer (난치성 괴양)

  • 이승근
    • Proceedings of the Korean Society of Veterinary Pathology Conference
    • /
    • 2002.11a
    • /
    • pp.66-79
    • /
    • 2002
  • The basic treatments - Epithelial & stromal debridement with a swab or diamond burr. - Possible placement of a collagen shield or nictitans flap. - Topical treatment with Adequan IM diluted in artificial tears : 1 ml Adequan + 4 ml tears : One drop four times daily. - Topical treatment with an antibiotic drop : Three times daily - 5% sodium chloride ointment : Four times daily. If inflammation is severe - Topical treatment with nonsteroidal agent : Four times daily (Voltaren, Ocufen, or Profenyl) - Cyclosporine A (Optimmune) : Twice daily Healing time - Healing typically occurs rapidly - Fluorescein negative : 7-10 days - Vascular keratitis : Often several months

  • PDF

Eastern and Western Combined Medical Treatments on 11 Patients with Dry Eye Syndrome (안구건조증환자 11례의 한·양방 병용치료에 대한 임상보고)

  • Lee, Dong-Jin;HwangBo, Min;Seo, Hyung-Sik;Kim, Soo-Jin;Lee, Jong-Soo
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.25 no.2
    • /
    • pp.61-67
    • /
    • 2012
  • Objective : The endpoint of this trial is to verify therapeutical availability of conventional western eyedrops combined with acupuncture treatment by means of BUT(tear film break-up time), Schirmer's test, which have been considered to be typical methods for diagnosing dry eye syndrome. Methods : The subjects of this trial included the outpatients who had been diagnosed with dry eye syndrome in Pusan national university hospital and underwent acupuncture treatment from March 2011 to April 2011. They received acupuncture treatment once a week, three times while constantly using Restasis or artificial tears. We collated and analyzed the outcome data of Schirmer's test and BUT conducted at the beginning of this trial and three times more after each acupuncture treatments. Acupoints, such as, Chanjuk(BL2), Eoryo, Sajukgong(TE23), Taeyang, Sabaek(ST2), limited around both eyes were selected based on their clinical effects referring to medical books. Results : 1. From BUT test results, Restasis and acupuncture combined group showed statistically significant difference, however, artificial tears and acupuncture combined group showed difference only between before and after the treatment, which is not statistically significant. 2. From Schirmer's test results, Restasis and acupuncture combined group showed statistically significant difference, however, artificial tears and acupuncture combined group showed difference only between before and after the treatment, which is not statistically significant. 3. The average duration of treatment was statistically 16.3 days for Restasis and acupuncture combined group. Conclusions : Combination of acupuncture and Restasis for dry eye syndrome can shorten the duration of treatment. Therefore, clinical benefit is expected to be worth.

Influence of Artificial Tear Containing Carboxymethyl Cellulose Component on Physical Properties of Hydrogel Contact lens (카르복시메칠 셀룰로오스 성분이 포함된 인공누액이 하이드로젤 콘택트렌즈의 물성에 미치는 영향)

  • Cho, Seon-Ahr;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.457-463
    • /
    • 2013
  • To determine the impact of artificial tears which include carboxymethyl cellulose on a hydrogel contact lenses. Methods: A contact lenses made of the cross-linking agent, EGDMA (ethylene glycol dimethacrylate) and HEMA (2-hydroxyethyl methacrylate) and with added NVP (n-vinyl-2-pyrrolidone) and MMA (methyl methacrylate) was evaluated for water content, refractive index, spectral transmittance and contact angle of produced contact lens. Results: The physical properties of the sampled copolymerized polymers showed that water content, refractive index, visible ray transmittance and contact angle were in the range of 26.61%~48.58%, 1.422~1.455, 80.8%~91.4% and $33.93^{\circ}{\sim}65.70^{\circ}$, respectively. In addition, after soaking with artificial tears, the water content, refractive index and contact angle were in the range of 24.46%~48.25%, 1.422~1.457, 77.0%~91.0% and $37.25^{\circ}{\sim}77.33^{\circ}$, respectively. The changes of the physical property depending on hydration time and showed an increase of refractive index and contact angle, decrease of water content and visible ray transmittance. Conclusions: Artificial tears which include carboxymethyl cellulose sodium which is used as a wetting agent influenced water content, refractive index, contact angle and spectral transmittance of a hydrogel contact lenses.

Development of Paper-based Microfluidic Device for Dry Eye Test (종이-미세유체공학을 이용한 건성안 검사 용지 개발)

  • Seo, Young Tae;Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.93-99
    • /
    • 2013
  • Purpose: The aim of this study was to develop a dry eye test method using a paper based microfluidic device that improves inaccuracy caused by using one of current point-of-care dry eye tests such as Shirmer's. Methods: Wax printed hydrophilic chromatography papers were dyed with anthocyanin extracts to detect colorimetric display of liquid samples with varying pH. Fluid distribution rates were measured using artificial tears and human tears directly from 32 subjects. Results: With Shirmer's, fluid distribution rates with small amount of samples (less than $0.5{\mu}l$) were not displayed. However, with paper based microfluidic device, fluid imbibition distances over time were clearly showed. Also clinical results of dry eye from newly developed paper based microfluidic device showed correlation with the results from tear break up time tests. Conclusions: The newly developed paper based microfluidic devices were easy to use and exhibited more accurate clinical results than current dry eye point of care tests such as Shirmer's.

Characteristics of the Grunge Look in 21st century fashion (21세기 패션에 나타난 그런지 룩의 표현특성)

  • Kim, Sun-Young
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.5
    • /
    • pp.957-969
    • /
    • 2011
  • This study intended to analyze the grunge look as a mode of expression and as a characteristic of the fashion of the 21st century, arguing that the look expressed not only an outward appearance or sub-culture but also a change in our attitude and spirit about contemporary fashion. In the study, I carried out an empirical analysis focused on the collection from 2001S/S to 2010F/W and a literature review. In my results, I classified the grunge look into the following categories: 1. mix and match layering; 2. patchwork, collages, and assemblage using all objects as well as clothing materials; and 3. distressing techniques, such as bleaching and dyeing, unweaving, and tears and holes. I also classified the characteristics of grunge into the following categories: 1. conspicuous destitution, which is intentionally expressed by skillful techniques and craftsmanship, indicating that modern people want to attract attention and be distinguished from others, which reflects an attitude of superiority through ironic fashion choices; 2. high lighting the dissolution of decoration, where destruction, poverty and recombination shown in the grunge look emerged as an artificial and intentional ugly aesthetic in contrast to the existing elegant and sophisticated image; and 3. satire and playfulness, as grunge expresses alienation and conflict in modern society through satire and sarcasm, not attacking or avoiding, but through playful and sarcastic engagement so as to decrease poverty and give temporary freedom.

Adsorption Properties of the Lysozyme and Albumin with Physicochemical Properties of the Contact Lens (콘택트렌즈의 물리화학적 특성에 따른 라이소자임과 알부민의 흡착 특성)

  • Sung, Yu-Jin;Ryu, Geun-Chang;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.261-270
    • /
    • 2013
  • Purpose: Adsorption properties of lysozyme and albumin according to physiochemical properties of commercial contact lens classified with the FDA categories and a contact lens fabricated in the laboratory were investigated. Methods: The contact lens were prepared using HEMA(2-hydroxyethyl methacrylate) and TRIM(3-(trimethoxysilyl) propyl methacrylate) in a cast mold. Artificial tears containing lysozyme and albumin were prepared. We measured the amounts of protein adsorbed on the each lenses with varying adsorbed time (48 hour) and the pH range (6, 6.8, 7.4, 8.2, 9) of artificial tear. Amount of the proteins absorbed on the contact lenses were measured by using HPLC. Results: Time to reach the equilibrium of protein adsorption for silicone hydrogel lens was taken longer than hydrogel lens. The amount of adsorbed both lysozyme and albumin at equilibrium were greater for the hydrogel lens than the silicone hydrogel lens, and larger for the ionic lens than the non-ionic lens. Lysozyme was more adsorbed on the higher water content of contact lens, whereas albumin was more adsorbed on the lower water content of contact lens. Only lysozyme was adsorbed on the Group IV hydrogel lens of ionic higher water content. The adsorption of protein on contact lens increased with pH of artificial tears as close to the isoelectric point of each protein. Conclusions: The adsorption amount of lysozyme is more affected by the ionic strength of the contact lens surface than the water content of contact lens. Albumin adsorption is more affected by water content than the ionic strength of the contact lens surface. For the adsorption of proteins on the silicone hydrogel lens, the pore size, determined both by the number of Si atoms and the chemical structure of the silicone-containing monomers, as well as the polarity of contact lens should be also considered.

Surface Modification of Gold Electrode Using Nafion Polymer and Its Application as an Impedance Sensor for Measuring Osmotic Pressure (나피온 폴리머를 이용한 금 전극의 표면 개질 및 이의 삼투압 측정용 임피던스 센서 응용)

  • Min Sik, Kil;Min Jae, Kim;Jo Hee, Yoon;Jinwu, Jang;Kyoung G., Lee;Bong Gill, Choi
    • Applied Chemistry for Engineering
    • /
    • v.34 no.1
    • /
    • pp.9-14
    • /
    • 2023
  • In this work, we developed a Nafion polymer-coated impedance sensor with two gold electrode configurations to measure the ion concentration in solution samples. The gold electrodes were fabricated through the sputtering process, followed by surface modification using Nafion polymer. The resulting sensors enable the prevention of the polarization phenomenon on the electrode surface, resulting in stable measurement of electrochemical signals. Spectroscopy and scanning electron microscopy measurements revealed that the thin film of Nafion was coated uniformly onto the surface of the gold electrode. The Nafion-coated sensor exhibited more stable impedance signals than the conventional gold electrode. It showed a highly reliable calibration curve (R2 = 0.983) of the impedance sensor using a standard sodium chloride solution. In addition, a comparison experiment between the impedance sensor and a commercial conductivity sensor was performed to measure the ion concentration of artificial tears, showing similar results for the two sensors.

The Comparative Study on the wettability of the RGP lens multi-purpose solutions(MPSs) (RGP lens 다목적용액의 습윤성에 관한 비교 연구)

  • Park, Hyun-Ju;Goe, Eun-Kyung;Seo, Eun-Sun;Kim, Jai-Min;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.119-127
    • /
    • 2003
  • We measured the effect of wettability of six MPSs for RGP lens. The used MPSs(multipurpose solutions) were OPTI-SOAK(ALCON), SOLO care hard(CIBA Vision), Total care(ALLERGAN), Simplicity(BOSTON). Wetting and Soaking Sol.(Bausch & Lomb) and Aquas-multi(Saehan). These MPSs keeps hydrophilic property of lens surface and increase the effect of cleaning or increase the effect of preservative effect. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. The results showed that every lens was nearby hydrophilic property within $25^{\circ}{\sim}36^{\circ}$. Also, it was differed by various factors. The surface tension showed various differences between 19.8 and 31.3(mN/m). In the viscosity, MPSs represented the highest viscosity between $4^{\circ}C$ and $20^{\circ}C$. It was much higher than compared with the viscosity of soft lens MPS. This experiment could be used to grasping the interaction between solutions used to MPS and the natural endowments of lens and to considering the relations of different factors effecting the wettability.

  • PDF

RGP lens 다목적 용액의 습윤성에 관한 비교 연구

  • Park, Hyeon-Ju;Kim, Jae-Min;Lee, Gi-Yeong
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.428-433
    • /
    • 2003
  • We measured the effect of wettability of six MPSs for RGP(rigid gas permeable) lens. The used MPSs(multipurpose solutions) were OPTI-SOAK(ALCON), SOLO care hard(CIBA Vision), Total care(ALLERGAN), Simplicity(BOSTON), Wetting and Soaking Sol.(Bausch & Lomb) and Aquas-multi(Saehan). These MPSs keeps hydrophilic property of lens surface and increase the effect of cleaning or increase the effect of preservative effect. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. The results showed that every lens was nearby hydrophilic property within $25\;^{\circ}-36\;^{\circ}$. Also, it was differed by various factors. The surface tension showed various differences between 19.8 and 31.3 mN/m. In the viscosity, MPSs represented the highest viscosity between $4^{\circ}C$ and $20^{\circ}C$. It was much higher than compared with the viscosity of soft lens MPS. This experiment could be used to grasping the interaction between solutions used to MPS and the natural endowments of lens and to considering the relations of different factors effecting the wettability.

  • PDF