• Title/Summary/Keyword: artificial sewage

Search Result 73, Processing Time 0.024 seconds

A Testing Method of Indoor Artificial Acceleration for the evaluation of Biochemical Corrosion Properties of Sewage Concrete (하수시설 콘크리트의 생화학적 부식특성 평가를 위한 실내 인공촉진 시험방법)

  • Lee, Eui-Bae;Kim, Do-Su;Khil, Bae-Su;Lee, Seung-Hoon;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.69-72
    • /
    • 2006
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. To prevent biochemical corrosion of the sewage concrete, antibiotics which prevent growth of sulfur-oxidizing bacteria were developed. Existing methods to evaluate properties of biochemical corrosion of concrete examine the antimicrobial performance and resistance to sulfuric acid separately, but don't complexly. So, in this study, new method to test properties of biochemical corrosion of concrete complexly is suggested.

  • PDF

Effects of oral administration with fermented product from sewage in land-based seawater fish farm on haematological factors of olive flounder, Paralichthys olivaceus (양식장 배출물 발효물의 어류 사료 첨가에 따른 넙치, Paralichthys olivaceus의 혈액학적 변동에 미치는 영향)

  • Gang, Ju-Chan;Ji, Jeong-Hun;Song, Seung-Yeop;Mun, Sang-Uk;Gang, Ji-Ung;Lee, Yeong-Don;Kim, Se-Jae
    • Journal of fish pathology
    • /
    • v.17 no.1
    • /
    • pp.57-66
    • /
    • 2004
  • Effects of oral administration with fermented product from sewage in land-based seawater fish farm on haematological disturbance in the olive flounder, Paralichthys olivaceus was investigated. After 4 weeks of conditioning with a basal diet, fish were divided into 4 groups and provided experimental diet (0.1, 0.5, 1.0 and 2.0%) supplement of fermented sewage for 80 days. Proximal analysis was performed for the product of sewage which was fermented by lactic acid and yeast. RBC count, hemoglobin concentration and hematocrit value were increased according to the treated periods, however, no statistical difference was observed between control and treatment groups. There were no significant difference in serum organic, inorganic compounds and enzyme activities between control and treatment groups. This study hypothesized that the supplement of fermented product from sewage in land-based seawater fish farm might be an additive supplement for source of fish diet in view of haematological examination. Recycling of the sewage may be an economic artificial sources of diet for fish aquaculture practices.

Evaluation of the Feasibility of Eliminating Non-point Source Pollution Using Waste Sewage Sludge Bio-blocks (하수슬러지를 이용한 Bio-block의 비점오염물질 제거 가능성 평가)

  • Han, Sang Moo;Kim, Do Hyeong;Jeong, Byung Gon
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.5
    • /
    • pp.363-368
    • /
    • 2021
  • On the assessment results of the non-point source pollutant removability of bio-block using waste sewage sludge, at the reactor's initial operation stage, the removal efficiency of COD was slightly unstable. However, after the reactor was stabilized, the COD removal efficiency was higher in the reactor filled with bio-blocks compared to the reactor filled with broken stones. In terms of nitrogen and phosphorus, their removal efficiency was unstable at the initial stage of the reactor operation. This phenomenon was investigated through the bio-block elution experiments. Results indicated that nitrogen and phosphorus were eluted from the bio-blocks affecting their removal at the initial operation. Furthermore, based on elution tests conducted after the dry ashing of the waste sewage sludge, part of the nitrogen and phosphorus was eluted similar to the bio-block elution test results, although considerable amounts of nitrogen and phosphorus were reduced compared to the sludge cake. Prior to the use of the waste sewage sludge bio-blocks as a filter medium to remove non-point source pollutants, a stabilization period of 10 days was required. After the stabilization process, results showed similar characteristics as general aggregates. Moreover, to use the bio-block as a filter medium for the non-point pollutant removal, the filling ratio of 75% was the most suitable as it resulted in the highest nitrogen removal efficiency after the stabilization. The results of this study suggested that waste sewage sludge can be suitably recycled as a mixed raw material for the bio-blocks, with satisfactory application as a filter medium in artificial wetlands, stormwater runoff problems, stream water pollutants to eliminate non-point source pollutants.

Groundwater Recharge and Discharge in the Urban-rural Composite Area (도농복합지역 지하수 함양과 배출에 대한 연구)

  • Lee, Byung-Sun;Hong, Sung-Woo;Kang, Hee-Jun;Lee, Ji-Seong;Yun, Seong-Taek;Nam, Kyoung-Phile
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.2
    • /
    • pp.37-46
    • /
    • 2012
  • This study was conducted to identify groundwater recharge and discharge amounts of a representative urban-rural composite area located in Yongin city, Kyounggi-do, Korea. Groundwater recharge would be affected by mainly two processes in the study area: rainfall and leakage from public water pipelines including water-supply and sewage system. Groundwater recharge rate was estimated to be 13.5% by applying annual groundwater level data from two National Groundwater Monitoring Stations to the master regression curve method. Subsequently, the recharge amounts were determined to be $13,253{\times}10^3m^3/yr$. Leakage amounts from water-supply and sewage system were estimated to be $3,218{\times}10^3$ and $5,696{\times}10^3m^3/yr$, respectively. On the whole, a total of the recharge amounts was $22,167{\times}10^3m^3/yr$, of which 60% covers rainfall recharge and 40% pipeline leakage. Groundwater discharge occurred through three processes in the composite area: baseflow, well pumping, and discharge from urban infrastructure including groundwater infiltration into sewage pipeline and artificial extraction of groundwater to protect underground facilities from submergence. Discharge amounts by baseflow flowing to the Kiheung agricultural reservoir and well pumping were estimated to be $382{\times}10^3$ and $1,323{\times}10^3m^3/yr$, respectively. Occurrence of groundwater infiltration into sewage pipeline was rarely identified. Groundwater extraction amounts from the Bundang subway line as an underground facility were identified as $714{\times}10^3m^3/yr$. Overall, a total of the discharge amounts was determined to be $2,419{\times}10^3m^3/yr$, which was contributed by 29% of artificial discharge. Even though groundwater budget of the composite area was identified to be a surplus, it should be managed for a sound groundwater environment by changing deteriorated pipelines and controlling artificial discharge amounts.

Disinfection Characteristic of Sewage Wastewater Treatment Using Solar Light/TiO2 Film System (태양광/광촉매를 이용한 오폐수 살균특성)

  • Cho Il-Hyoung;Lee Nae-Hyun;An Sang-Woo;Kim Young-Kyu;Lee Seung-Mok
    • Journal of Environmental Science International
    • /
    • v.15 no.7
    • /
    • pp.677-688
    • /
    • 2006
  • Currently, the application of $TiO_2$ photocatalyst has been focused on purification and treatment of wastewater. However, the use of conventional $TiO_2$ slurry photocatalyst results in disadvantage of stirring during the reaction and of separation after the reaction. And the usage of artificial UV lamp has made the cost of photocatalyst treatment system high. Consequently, we studied that solar light/$TiO_2$ film system was designed and developed in order to examine disinfection characteristics of sewage wastewater treatment. The optimum conditions for disinfection such as solar light intensity, characteristic of sewage wastewater, amounts of $TiO_2$ and comparison of solar ligth/$TiO_2$ systems with UV light/$TiO_2$ system was examined. The results are as follows: (1) photocatalytic disinfection process with solar light in the presence of $TiO_2$ film more effectively killed total coliform (TC) than solar light or $TiO_2$ film absorption only. (2) The survival ratio of TC and residual ratio of organic material (BOD, CODcr) decreased with remain resistant material. (3) The survival ratio of TC and residual ratio of organic material (BOD, CODcr) decreased with the increase of amounts of $TiO_2$. (4) TC survival ratio decreased linearly with increasing UV light intensity. (5) The disinfection effect of solar light/$TiO_2$ slurry system decreased more than UV light/$TiO_2$ film systems. (6) The disinfection reaction followed first-order kinetics. We suggest that solar light instead of using artificial UV light was conducted to investigate the applicability of alternative energy source in the disinfection of TC and the degradation of organic material.

Comparison and Management of Water Purification Efficiency of Artificial Wetland according to Inflow Water Conditions: Focusing on the Gyeongancheon Basin (유입수 조건에 따른 인공습지 수질 정화효율 비교: 경안천 유역을 중심으로)

  • Seol Jun Lee;Beomjin Eun;Jong Hwan Kim;I Song Choi;Jong-Min Oh
    • Korean Journal of Ecology and Environment
    • /
    • v.57 no.1
    • /
    • pp.28-38
    • /
    • 2024
  • In this study, in order to analyze the water purification efficiency according to the influent water conditions of artificial wetlands, the purification efficiency was compared at two points where sewage treatment water flows in and one point where good effluent flows in. As a result of reviewing the results of the analysis of influent and effluent and the removal efficiency, the T-N and T-P removal efficiency was calculated at 54.7% and 77.4%, respectively, for the two points where sewage treatment water was treated, the treatment efficiency of SS 90.8%, BOD 51.1%, TOC 30.6%, T-N 38.8%, T-P 55.3% was shown. As a result, the efficiency of removing pollutants in the artificial wetland was found to be proportional to the concentration of influent water, and in order to create an efficient artificial wetland, it is judged that thorough review and management at the design stage are necessary considering that the removal efficiency of high-concentration contaminated water was high.

Adaptation of Betula schmidtii Seedling in Coal-mine Field with Different Sewage Sludge Treatment Methods

  • Han, Sim-Hee;Lee, Jae-Cheon;Oh, Chang-Young;Kim, Pan-Gi
    • The Korean Journal of Ecology
    • /
    • v.28 no.4
    • /
    • pp.189-192
    • /
    • 2005
  • We tested the field adaptation of Betula schmidtii on the abandoned coal-mine soil with sludge amendment methods for promoting physiological activity of B. schmidtii seedlings under several environmental stress. Sewage sludges were amended to coal-mine soil with B. schmidtii seedlings which grown in the mixture of artificial soil and composted sludge soil before transplanting (before-fertilized treatment, BF) and fertilized with composted sludge after transplanting (after-fertilized treatment, AF). The percent of establishment of seedlings for AF (80.7%) was lower than that for BF (92.7%). Nitrate reductase activity and photosynthetic pigment content were higher in AF than in BF, but malondialdehyde (MDA) content and superoxide dismutase (SOD) activity were lower in AF than in BF These results represent that after-fertilized seedlings increase resistance against physiological stress at field condition using nitrogen source of composted sludge. On the contrary, before-fertilized seedlings were susceptible to environmental stress on abandoned coal-mine soil by exhausting of nitrogen source from composted sludge.

Radioactive iodine analysis in environmental samples around nuclear facilities and sewage treatment plants

  • Lee, UkJae;Kim, Min Ji;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1355-1363
    • /
    • 2018
  • Many radionuclides exist in normal environment and artificial radionuclides also can be detected. The radionuclides ($^{131}I$) are widely used for labeling compounds and radiation therapy. In Korea, the radionuclide ($^{131}I$) is produced at the Radioisotope Production Facility (RIPF) at the Korea Atomic Energy Research Institute in Daejeon. The residents around the RIPF assume that $^{131}I$ detected in environmental samples is produced from RIPF. To ensure the safety of the residents, the radioactive concentration of $^{131}I$ near the RIPF was investigated by monitoring environmental samples along the Gap River. The selected geographical places are near the nuclear installation, another possible location for $^{131}I$ detection, and downstream of the Gap River. The first selected places are the "front gate of KAERI", and the "Donghwa bridge". The second selected place is the sewage treatment plant. Therefore, the Wonchon bridge is selected for the upstream of the plant and the sewage treatment plant is selected for the downstream of the plant. The last selected places are the downstream where the two paths converged, which is Yongshin bridge (in front of the cogeneration plant). In these places, environmental samples, including sediment, fish, surface water, and aquatic plants, were collected. In this study, the radioactive iodine ($^{131}I$) detection along the Gap River will be investigated.

A Study on Operation Control Technology Required for Introduction of Intelligent Sewage Treatment Plant (스마트 하수처리장 도입에 필요한 운전제어기술에 관한 연구)

  • Lee, Jiwon;Kim, Yuhyeon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.38-43
    • /
    • 2022
  • Smart sewage treatment plant means creating a safe and clean water environment by establishing an ICT-based real-time monitoring, remote control management and intelligent system for the entire sewage treatment process. The core technology of such a smart sewage treatment plant can be operation control technology using measuring instruments. This research team analyzed and suggested the operation control technologies necessary for the establishment of the intelligent business by referring to the intelligent research projects of the sewage treatment plant in progress in Korea. As a result of the analysis, a total of six removal technologies were presented, including control by scale, reflow water control, linked treated water control, chemical quantity control, winter operation control, and total organic carbon control. By size, standards that can be classified into small and medium-sized large-scale are presented, and in the case of reflow water control, the location of water quality and flow sensors capable of managing reflow water is suggested. In the case of the linked treated water control, the influence and control points of the linked treated water on the sewage treatment plant were presented, and in the case of the chemical injection volume control, a system capable of optimizing the amount of chemical injection according to the introduction of an intelligent sewage treatment plant was presented. In the case of winter operation, the sensors and pumps to be controlled are suggested when considering the decrease in nitrification due to the decrease in water temperature. In the case of total organic carbon control, an interlocking system considering the total amount of pollution in the future was proposed. These operation control scenarios are expected to be used as basic data to be used in intelligent sewage treatment algorithms and scenarios in the future.

Odor Reduction Technology in Sewage Treatment Facility Using Biofilter with Reed Grass(Phragmites australls) (갈대(Phragmites australls)수초를 적용한 바이오필터에서의 하수처리시설 악취저감기술)

  • Chung, Jin-Do;Kim, Kyu-Yeol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.373-382
    • /
    • 2013
  • In this study, a biological odor treatment system was proposed to remove odor(foul smell) materials causing several problems in the closed sewage treatment plant. This odor treatment system was composed of a two-step biofilter system in one reactor. The two-step biofilter reactor was constructed with natural purification layer in upper part and artificial purification layer in lower part. The reed grasses of water purification plants were planted in the surface area and mixed porous ceramic media were filled with the lower part of biofilter reactor. By using the above experimental apparatus, the ammonia gas removal efficiency was attained to 98.3 % and the hydrogen sulfide gas removal efficiency was appeared more than 97.7 % which shows more effective than the conventional odor removal process.