• 제목/요약/키워드: artificial joint

검색결과 274건 처리시간 0.032초

유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구 (Contact Stress Analysis of Artificial Hip Joints Using Finite Element Method)

  • 김청균;윤종덕
    • Tribology and Lubricants
    • /
    • 제13권1호
    • /
    • pp.82-87
    • /
    • 1997
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires a re-replacement of hip joints because it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focussed on the development of new materials. The research of new materials, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find new combinations of bio-materials in the total hip replacement which has the excellent contact characteristics. A non-linear FEM program MARC with 5-node axisymmetric element was used for analyzing the contact stresses between the hip joints. The computed results show that in case of acetabulum UHMWP has good characteristics, in femoral head, $Al_2O_3$, and in stem, Ti6Al4V.

인공 관절 설계를 위한 바이오미메틱 복합재료에 관한 연구 (A Study on Biomimetic Composite for Design of Artificial Hip Joint)

  • 김명욱;윤재륜
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.234-238
    • /
    • 1999
  • This study suggests the design of the functionally gradient composite, [0/90/0/core]$_s$ cross-ply laminate, to prevent stress concentration induced from the difference of rigidity between the bone and the artificial hip joint and to reinforce the wear property of the surface and the expectation of their mechanical properties. First, the four-point bending test is done about wet bones and dry bones to know the mechanical properties of the cortical bones. In result, the wet bone shows the viscoelastic behavior and the dry bone shows the elastic behavior. Moreover, we expect the properties of the proposed gradient composites as a function of carbon fiber volume fraction in each layer to apply Halpin-Tsai equation, CLPT(classical laminate plate theory), and Bernoulli beam theory etc. and decide the thickness ratio of each lamina in order to match Young's modulus of the anisotropic cortical bone with the proposed gradient composites.

  • PDF

A Distributed Implementation Algorithm for Physical Layer Security Based on Untrusted Relay Cooperation and Artificial Noise

  • Li, Xiangyu;Wang, Xueming;Xu, Xiangyang;Jin, Liang
    • ETRI Journal
    • /
    • 제36권1호
    • /
    • pp.183-186
    • /
    • 2014
  • In this letter, we consider a cooperation system with multiple untrusted relays (URs). To keep the transmitted information confidential, we obtain joint channel characteristics (JCCs) through combining the channels from the source to the destination. Then, in the null space of the JCCs, jammers construct artificial noise to confuse URs when the source node broadcasts its data. Through a distributed implementation algorithm, the weight of each node can be obtained from its own channel state information. Simulation results show that high-level security of the system can be achieved when internal and external eavesdroppers coexist.

Wiretapping Strategies for Artificial Noise Assisted Communication in MU-MIMO wiretap channel

  • Wang, Shu;Da, Xinyu;Chu, Zhenyong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권5호
    • /
    • pp.2166-2180
    • /
    • 2016
  • We investigate the opposite of artificial noise (AN)-assisted communication in multiple-input-multiple-output (MIMO) wiretap channels for the multiuser case by taking the side of the eavesdropper. We first define a framework for an AN-assisted multiuser multiple-input-multiple-output (MU-MIMO) system, for which eavesdropping methods are proposed with and without knowledge of legitimate users' channel state information (CSI). The proposed method without CSI is based on a modified joint approximate diagonalization of eigen-matrices algorithm, which eliminates permutation indetermination and phase ambiguity, as well as the minimum description length algorithm, which blindly estimates the number of secret data sources. Simulation results show that both proposed methods can intercept information effectively. In addition, the proposed method without legitimate users' CSI performs well in terms of robustness and computational complexity.

Artificial Intelligence and Nursing: Looking Back at Florence Nightingale

  • Jeong, Suyong
    • 근관절건강학회지
    • /
    • 제28권3호
    • /
    • pp.217-222
    • /
    • 2021
  • Background: The reaction of nurses to the advent of artificial intelligence (AI) during the fourth industrial revolution era remains questionable. Understanding Florence Nightingale's achievements may provide valuable lessons that will be helpful to contemporary nurses. Aims: To understand Nightingale's nursing philosophy and methods and provide suggestions for future nursing practice, education, research, and health policy. Source of evidence: Literature. Discussion/Conclusion: Just as Nightingale captured the situation of her time and introduced latest scientific methods, modern nurses need to learn from Nightingale's drastic actions to meet social needs. Nursing can regain a solid humanistic foundation by returning to core values of nursing and humanities, while simultaneously adopting state-of-the-art technologies. Implications for Nursing Policy: AI-driven technologies will advance nursing services and provide greater human-centered and personalized care by eliminating iterative and labor-intensive tasks. Nursing educational policy should support the advancement of nursing curricula to develop AI competencies and specialists within the nursing field.

건강한 성인에서 인위적 다리길이 차이가 보행 중 3차원 엉덩관절 모멘트에 미치는 효과 (Effect of Artificial Leg Length Discrepancy on 3D Hip Joint Moments during Gait in Healthy Individuals)

  • 조민지;김동현;한동욱;최은진;김예슬;김용욱
    • PNF and Movement
    • /
    • 제17권3호
    • /
    • pp.391-399
    • /
    • 2019
  • Purpose: This study investigated the three-dimensional moment values of the hip joint for subjects with artificial leg length alterations and subjects with unaltered leg lengths. Methods: Forty-two healthy adults (8 men, 34 women) participated in this study. The selected subjects were able to walk normally, had less than a 1 cm leg length discrepancy, and were instructed to wear shoes that fit their feet. The study participants performed 8 dynamic gait trails to measure the hip joint moment using a three-dimensional motion analysis system. Kinetic and dynamic three-dimensional gait analysis data were collected from infrared cameras, and a force plate was used to standardize the weight of each subject. Results: There were significant correlations between the differences in the leg length discrepancy during right extension, right flexion, right internal rotation, and left extension in hip joint moments (p<0.05). There were significant correlations between the differences in shoe conditions during left extension, right flexion, right extension, and right internal rotation in the hip moments (p<0.05). Conclusion: This study suggests that a leg length discrepancy can affect hip joint moment, which may further exacerbate musculoskeletal disorders, such as osteoarthritis in lower extremity joints. Therefore, further studies should be conducted to verify the impact of clinical interventions on differences in hip joint moment values to correct leg length discrepancies and prevent osteoarthritis in lower extremity joints.

보 이론을 이용한 대퇴골 재생성의 해석 (Book Remodeling Analysis of Femur Using Hybrid Beam Theory)

  • 김승종;정재연;하성규
    • 대한기계학회논문집A
    • /
    • 제24권2호
    • /
    • pp.329-337
    • /
    • 2000
  • An investigation has been performed to develop an analysis tool based on a nonlinear beam theory, which can be used to predict the long-term behavior of an artificial hip joint. The nonlinear behav ior of the femur arise from the coupled dependence of the bone density and the mechanical properties on each other. The beam theory together with its numerical algorithm is developed to take into account the nonlinear bone remodeling process of the femur that is long enough to be assumed as a beam. A piecewise linear curve for the bone remodeling rate is used in the bone remodeling theory and the surface area density of bone is modeled as the third order polynomial function of bone density. At each section of the beam, a constant curvature is assumed and the longitudinal strains are also assumed to vary linearly across the section. The Newton-Rhapson iteration method is used to solve the nonlinear equations for each cross section of the bone and a backward method is used to march along the time. The density and the remodeling signal ar, calculated along with time for the various time steps, and the developed beam theory has been verified by comparing with the results of finite element analysis of a remodeling bone with an artificial hip joint of titanium prosthesis subjected to uni-axial loads and pure bending moment. It is concluded that the developed beam theory can be used to predict the long-term behavior of the femur and thus to design the artificial hip prosthesis.

Artificial rearing of the olive fruit fly Bactrocera oleae (Rossi) (Diptera: Tephritidae) for use in the Sterile Insect Technique: improvements of the egg collection system

  • Ahmad, Sohel;Haq, Ihsan ul;Rempoulakis, Polychronis;Orozco, Dina;Jessup, Andrew;Caceres, Carlos;Paulus, Hannes;Vreysen, Marc J.B.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제33권1호
    • /
    • pp.15-23
    • /
    • 2016
  • One major constraint in the development and implementation of a successful and cost-effective area-wide integrated pest management (AW-IPM) programme with a SIT component for Bactrocera oleae (Diptera: Tephritidae) is the ability to produce a large number of high quality mass-reared individuals. The aim of this study was to develop a more efficient and practical egg collection system in an attempt to improve the mass-rearing of this species. The following basic parameters were examined: egg production per female, egg hatch, pupal recovery, pupal weight, adult emergence and percentage of fliers. Three different strains (Israel wild-type, France wild-type, and Greece laboratory) were tested and each strain was evaluated for six generations. Female flies of the Israel strain produced significantly more eggs per female than the other two strains, but egg hatch was significantly lower. Egg hatch of the France wild type and the Greece laboratory strain was similar. For all other parameters, there was no significant difference between strains; however, there was a significant generational effect for all parameters observed. As a result of this study, a protocol was developed for the mass-rearing of this species that included the use of large adult holding cages that could house up to 96,000 flies per cage. The newly developed method of egg collection using a flat wax panel as one of the sides of an adult holding cage proved to be cost-effective, efficient, making colony growth easier for industrial mass-rearing.