• Title/Summary/Keyword: artificial bone

Search Result 231, Processing Time 0.024 seconds

Evaluation of the clinical efficacy of a TW3-based fully automated bone age assessment system using deep neural networks

  • Shin, Nan-Young;Lee, Byoung-Dai;Kang, Ju-Hee;Kim, Hye-Rin;Oh, Dong Hyo;Lee, Byung Il;Kim, Sung Hyun;Lee, Mu Sook;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.237-243
    • /
    • 2020
  • Purpose: The aim of this study was to evaluate the clinical efficacy of a Tanner-Whitehouse 3 (TW3)-based fully automated bone age assessment system on hand-wrist radiographs of Korean children and adolescents. Materials and Methods: Hand-wrist radiographs of 80 subjects (40 boys and 40 girls, 7-15 years of age) were collected. The clinical efficacy was evaluated by comparing the bone ages that were determined using the system with those from the reference standard produced by 2 oral and maxillofacial radiologists. Comparisons were conducted using the paired t-test and simple regression analysis. Results: The bone ages estimated with this bone age assessment system were not significantly different from those obtained with the reference standard (P>0.05) and satisfied the equivalence criterion of 0.6 years within the 95% confidence interval (-0.07 to 0.22), demonstrating excellent performance of the system. Similarly, in the comparisons of gender subgroups, no significant difference in bone age between the values produced by the system and the reference standard was observed (P>0.05 for both boys and girls). The determination coefficients obtained via regression analysis were 0.962, 0.945, and 0.952 for boys, girls, and overall, respectively (P=0.000); hence, the radiologist-determined bone ages and the system-determined bone ages were strongly correlated. Conclusion: This TW3-based system can be effectively used for bone age assessment based on hand-wrist radiographs of Korean children and adolescents.

A Study on Biomimetic Composite for Design of Artificial Hip Joint (인공 관절 설계를 위한 바이오미메틱 복합재료에 관한 연구)

  • 김명욱;윤재륜
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.234-238
    • /
    • 1999
  • This study suggests the design of the functionally gradient composite, [0/90/0/core]$_s$ cross-ply laminate, to prevent stress concentration induced from the difference of rigidity between the bone and the artificial hip joint and to reinforce the wear property of the surface and the expectation of their mechanical properties. First, the four-point bending test is done about wet bones and dry bones to know the mechanical properties of the cortical bones. In result, the wet bone shows the viscoelastic behavior and the dry bone shows the elastic behavior. Moreover, we expect the properties of the proposed gradient composites as a function of carbon fiber volume fraction in each layer to apply Halpin-Tsai equation, CLPT(classical laminate plate theory), and Bernoulli beam theory etc. and decide the thickness ratio of each lamina in order to match Young's modulus of the anisotropic cortical bone with the proposed gradient composites.

  • PDF

A RADIOGRAPHIC STUDY ON EXPERIMENTAL BONY LESIONS (실험적 골조직 병소부에 관한 방사선학적 연구)

  • Lee Eun Kee;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.233-248
    • /
    • 1987
  • The author studied the effect of periapical bone loss on radiographic interpretation by using a dry adult human mandible. Artificial bony lesions were created at the apices of two mandibular second molars and four mandibular bicuspids. The jaw was stabilized and various artificial lesions were radiographed under ideal circumstances. Radiographic pictures were recorded and compared with the size of the actual lesions. The obtained results were as follows: 1. The size of actual lesions were always larger than their radiographic pictures. 2. The size of actual lesion had a greater discrepancy in the molar area where the cortical plates were havier, but the lesions in the bicuspid areas were only slightely larger than their radiographic pictures, and in these areas the cortical plates were quite thin. 3 Periapical lesions located in cancellous bone did not appear on a radiograph, regardless of the size of the created lesion, but when the junctional bone was involved or the cortical plate was perforated, the definite bone destructive change was observed on the roentenogram. 4. Removal of the entire buccal or lingual plate did not affect the trabecular pattern of bone on the roentgenogram. 5. When the cancellous bone and junctional bone were removed simultaneously, altered trabecular patterns were observed on the roentgenogram.

  • PDF

A QUANTITATIVE STUDY OF BONE DENSITY ON RADIOGRAM BY USING IMAGE ANALYZER (영상 분석장치를 이용한 골 흑화도의 정량적 평가에 관한 연구)

  • Choi Won-Jae;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.521-533
    • /
    • 1995
  • This study was performed to develop and evaluate the method to detect Quantitatively the serial changes in the size of artificial lesion in the spongious bone by automatic color image analyzer. 15 intraoral radiograms taken before and after endodontic treatment of 5 cases were used for contour line analysis. 30 intraoral radiograms taken by geometrically standardized apparatus before and after serially the formation of artificial lesions of 0.80, 1.20, 1.75, 2.00mm in diameter at the periapical area and interdental area of spongious bone were used. The analysis of image according to the variance of lesion size by 0.25, 0.35, 0.55, and 0.85mm serially was performed by the histogram and the color enhancement with subtraction. The images inputted by CCDcamera were digitized and analyzed by NEXUS QUBE program with NEC PC-9801 computer. The obtained results were as follows: 1. There was no reliability in the analysis of lesions by contour line 2 .. The mean difference of the grey scale at each pixel was 1 step between reference image and the corrected images. 3. In the analysis by histogram of the artificial lesion in spongeous bone, the change over 0.55mm in the mesiodistal size was detectable by the change of the numbers of pixel showing the change in grey scale. 4. In the analysis by histogram of the artificial lesion in spongeous bone, the change over 0.25mm in the buccolingual size was detectable by the change in grey scale. 5. By color enbancement with- subtraction, each lesion was able to be isolated and the change in it's mesiodistal size was detectable visually , but not in it's buccolingual size.

  • PDF

The effect of low-speed drilling without irrigation on heat generation: an experimental study

  • Oh, Ji-Hyeon;Fang, Yiqin;Jeong, Seung-Mi;Choi, Byung-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.1
    • /
    • pp.9-12
    • /
    • 2016
  • Objectives: In this study we evaluated heat generation during the low-speed drilling procedure without irrigation. Materials and Methods: Ten artificial bone blocks that were similar to human D1 bone were used in this study. The baseline temperature was $37.0^{\circ}C$. We drilled into 5 artificial bone blocks 60 times at the speed of 50 rpm without irrigation. As a control group, we drilled into an additional 5 artificial bone blocks 60 times at the speed of 1,500 rpm with irrigation. The temperature changes during diameter 2 mm drilling were measured using thermocouples. Results: The mean maximum temperatures during drilling were $40.9^{\circ}C$ in the test group and $39.7^{\circ}C$ in the control group. Even though a statistically significant difference existed between the two groups, the low-speed drilling did not produce overheating. Conclusion: These findings suggest that low-speed drilling without irrigation may not lead to overheating during drilling.

Effectiveness of autogenous tooth bone used as a graft material for regeneration of bone in miniature pig (미니피그에서 자가치아뼈 이식의 골형성 효과에 대한 연구)

  • Jeong, Hye-Rin;Hwang, Ju-Hong;Lee, Jeong-Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.5
    • /
    • pp.375-379
    • /
    • 2011
  • Introduction: This study examined the effect of autogenous tooth bone used as a graft material for bone regeneration in an artificial bony defect of minipigs. Materials and Methods: Four healthy minipigs, weighing approximately 35-40 kg, were used. Four standardized artificial two-walled bony defects, 5 mm in length and depth, were made on the bilateral partial edentulous alveolar ridge on the mandible of minipigs, and autogenous tooth bone was augmented in the right side as the experimental group. On the other hand, only alloplastic bone graft material HA was grafted with the same size and manner in the left side as the control group. All minipigs were sacrificed at 4 weeks after a bone graft and evaluated histologically by Haematoxylin-eosin staining. The specimens were also evaluated semi-quantitatively via a histomorphometric study. The percentage of new bone over the total area was evaluated using digital software for an area calculation. Results: All specimens were available but one in the left side (control group) and two in the right side (experimental group) were missing during specimen preparation. The amount of bone formation and remodeling were higher in all experimental groups than the control. The mean percentage area for new bone in the experimental and control groups was $43.74{\pm}11.96%$ and $30.79{\pm}2.93%$, respectively. Conclusion: Autogenous tooth bone is a good alternative to autogenous bone with the possible clinical feasibility of an autogenous tooth bone graft in the reconstruction of bony defects.

Observation of Mechanical Strength of Materials for Dog Dental Prosthesis Production (중형견(犬) 치과 보철물 제작을 위한 소재의 기계적 강도 관찰)

  • Park, Yujin;Choi, Sungmin
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.93-100
    • /
    • 2019
  • Purpose: This study is making a dog dental prosthesis using digital dental technology. The mechanical strength of the prosthetic material was observed in terms of compressive strength and fracture pattern. Methods: The experiment was performed using dog mandibular molars. The teeth were scanned and modeled. The specimens were made of zirconia, PMMA and Ni-Cr. The specimens were subjected to a vertical compression test with an artificial cancellous bone in UTM tester. Vertical compressive strength and fracture behavior of specimen were observed. Results: The result of observing the compressive load between specimen and artificial bone were $184.8{\pm}5.7N$ in the zirconia specimen, $185.6{\pm}8.9N$ in the PMMA specimen, and $184.4{\pm}4.0N$ in the Ni-Cr alloy specimen. Compression marks of artificial bones were observed. The fracture strength of specimen was observed. The fracture strength of the zirconia specimen was an average of 1,381.4N. The fracture strength of the PMMA specimen was an average of 572.2N. Conclusion: The crown made of three kinds(zirconia, PMMA, Ni-Cr alloy) of materials has the strength to chew about the artificial bone. zirconia and PMMA have vertical compressive strength applicable to medium dog dental prosthetic materials.

Biodegradable Inorganic-Organic Composite Artificial Bone Substitute

  • Suh, Hwal;Lee, Jong-Eun;Ahn, Sue-Jin;Lee, Choon-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.57-60
    • /
    • 1995
  • To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased.

  • PDF

The Usefulness of the Artificial Nail for Treatment of Fingertip Injuries (손가락끝 손상의 치료 시 인조손톱의 유용성)

  • Choi, Hwan-Jun;Kwon, Joon-Sung;Tark, Min-Seong
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.788-794
    • /
    • 2010
  • Purpose: The fingertip is the most commonly injured part of the hand and its injury frequently results in avulsion or crushing of a segment of the nail bed and fracture of the distal phalangeal bone. Restoration of a flat and smooth nail bed is essential for regrowth of a normal nail, which is important not only for cosmetic reasons but also for tactile capability of the fingertip. It is also anatomical reduction of the distal phalanx to promote patient's cosmetics and prevent nail bed deformity. Absence or no replacement of the nail plate results in obliterated proximal skin fold. When the avulsed nail plate cannot be returned to its anatomic position or when it is absent, we use a synthetic material for splinting the nail bed and alternative reductional method for distal phalangeal bone fracture, especially, instead of hardwares. Methods: From January of 2006 to June of 2009, a total of ten patients and fourteen fingers with crushing or avulsion injuries of the fingertip underwent using the artificial nails for finger splint. We shaped artificial nails into the appropriate sizes for use as fingernail plates. We placed them under the proximal skin fold and sutured to the fold proximally and to the lateral and medial edges of the nail bed or to the distal fingertip. Our splints were as hard as K-wire and other fixation methods and more similar to anatomic nail plates. Artificial nails were kept in place for at least 3 weeks. Results: No artificial nail related complication was noted in any of the ten cases. No other nail fold or nail bed complications were observed, except for minor distal nail deformity because of trauma. Conclusion: In conclusion, in order to secure the nail bed after injury and reduce the distal phalangeal bone fracture, preparing a nail bed splint from a artificial commercial nail is a cheap and effective method, especially, for crushed or avulsion injuries of the fingertip.