Single Coronary Artery Associated with Bicupid Aortic Valvular Stenosis -1 Case Report- (이첨 대동맥판막협착을 동반한 단일 관상동맥증 -1례 보고-)

  • 김우찬
    • Journal of Chest Surgery
    • /
    • v.27 no.6
    • /
    • pp.472-476
    • /
    • 1994
  • The incidence of single coronary artery is extremely rare in a review of congenital anomalies of the coronary arteries. This 27-year-old male patient was referred for the evaluation of cardiac condition showing exertional dyspnea[NYHA class II-III] and chest discomfort for about 1 year. A complete catheterization study including angiogram disclosed large single coronary artery arising from left aortic sinus [Ogden classification L-4] associated with bicuspid aortic valvular stenosis and low grade supravalvular aortic stenosis. Calcified stenotic aortic valve was fully removed with caution and the 19mm St. Jude Medical valve was then implanted in the small nortic annulus. The patient had an uneventful recovery and was discharged on 13th postoperative day.

  • PDF

Detection of Segmental Branch Renal Artery Stenosis by Doppler US: A Case Report

  • Chang Kyu Seong;Seung Hyup Kim;Jung Suk Sim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.57-60
    • /
    • 2001
  • In stenosis of a segmental branch or among multiple renal arteries, Doppler sampling of intrarenal arteries in the upper, mid and lower poles demonstrates strikingly different waveform patterns that might otherwise be overlooked. We report a case of segmental branch renal artery stenosis in which a pulsus parvus et tardus waveform was observed in a segmental branch of a renal artery. In this case, systematic analysis of Doppler waveforms of intrarenal arteries at more than three different locations facilitated a rapid and confident diagnosis of segmental branch renal artery stenosis.

  • PDF

New Carotid Artery Stenosis Measurement Method Using MRA Images (경동맥 MRA 영상을 이용한 새로운 내경 측정 방법)

  • 김도연;박종원
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.12
    • /
    • pp.1247-1254
    • /
    • 2003
  • Currently. the north american symptomatic carotid endarterectomy trial, european carotid surgery trial, and common carotid method are used to measure the carotid stenosis for determining candidate for carotid endarterectomy using the projection angiography from different modalities such as digital subtraction angiography. rotational angiography, computed tomography angiography and magnetic resonance angiography. A new computerized carotid stenosis measuring system was developed using MR angiography axial image to overcome the drawbacks of conventional carotid stenosis measuring methods, to reduce the variability of inter-observer and intra-observer. The gray-level thresholding is one of the most popular and efficient method for image segmentation. We segmented the carotid artery and lumen from three-dimensional time-of-flight MRA axial image using gray-level thresholding technique. Using the measured intima-media thickness value of common carotid artery for each cases, we separated carotid artery wall from the segmented carotid artery region. After that, the regions of segmented carotid without artery wall were divided into region of blood flow and plaque. The calculation of carotid stenosis degree was performed as the following; carotid stenosis grading is(area measure of plaque/area measure of blood flow region and plaque) * 100%.

Hemodynamic Analysis of Coronary Artery Microcirculation Using a Pig's Morphometric Data

  • Shin Sehyun;Park Jungsu
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.1313-1320
    • /
    • 2005
  • Stenosed coronary artery may play an important role in various coronary heart diseases. However, it has not been known how much stenosed coronary artery affects coronary circulation system, quantitatively. The present study developed a mathematical model for microcirculation in the left common coronary artery (LCCA) with adopting a previously measured morphological data and mechanical properties of the coronary vessels. We examine the effect of percent diameter stenosis on blood flow rate and shear stress for two cases. Case I comprised of one-stenosed element at $10^{th}$ order ($\%$ diameter stenosis are 10, 30, and 50, respectively). Case II consisted of completely occluded element at $10^{th}$ order (number of occluded elements are 0, 1, and 2 out of 8, respectively). As the level of stenosis becomes severe, the shear stress increases significantly but the flow rate reduction was relatively small. However, for the occluded case, there was linearly proportional reduction of flow rate according to number of occluded elements. Either such high shear stress associated with coronary artery stenosis or reduced flow rate due to occlusion may cause atherosclerosis and myocardial ischemia.

One Sage Operation for Bilateral Carotid Arterial Obstruction and Right Coronary Artery Ostial Stenosis in Takayasu's Arteritis -Report of One Case- (Takayasu씨 대동맥염에 의한 양경동맥협착과 우관상동맥개구협착의 동시수술치험 -1례 보고-)

  • 정일영
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.320-323
    • /
    • 1995
  • We report a case of recurred Takayasu,s arteritis.The patient was 28-year-old female underwent aorto-left common carotid and aorto-left subclavian bypass graft replacement 1 year ago.Unfortunately, she was readmitted because of newly developing angina and both eye claudication severe headache. Aorto-coronary angiogram showed complete obstruction of left common carotid artery ,stenosis of right carotid artery bifurcation and ostial stenosis of right coronary artery.Bilateral carotid arteries bypass graft with great saphenous vein and right coronary artery bypass graft with right internal mammary artery were done at same the time and she discharged after 21 days without any problem.

  • PDF

Flow comparison between Stenosed Coronary and Abdominal Arteries (협착된 관상동맥과 복부 대동맥의 유동 특성 비교)

  • Kim, M.C.;Lee, C.S.;Kim, C.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.585-590
    • /
    • 2001
  • The hemodynamic characteristics were compared using commercial CFD code for the stenosed coronary and abdominal arteries. Numerical calculations were carried out in the axisymmetric arteries over the stenotic diameter ratios ranging from 0.25 to 0.875 (6 cases) employing the typical physiological flow conditions. In case of the coronary artery, there was only one recirculation zone observed distal to the stenosis throat during the major portion of the period. However, in case of the abdominal aorta, there were complex recirculation regions found proximal and distal to stenosis throat. For both models, the wall shear stresses(WSS) increased sharply in the converging stenosis, reaching a peak just upstream of the throat, and became negative or low values in the post-stenotic recirculation region. As the results, the oscillatory shear index(OSI) was abruptly increased at the stenosis throat. For the coronary stenosis model, the second peak in the OSI was observed distal to the stenosis. The distance between the first peak and the second peak was increased as the degree of the stenosis was raised. On the orther hand, the abdominal stenosis model showed a complex oscillatory behavior in the OSI index and did not showed such a strong second peak. As the degree of stenosis was increased, recirculation regions of the both arteries were extended much longer and flow pattern became more complex.

  • PDF

The Evaluation of Carotid Artery Stenosis Using Spiral CT. (Spiral CT를 이용한 경동맥 질환의 평가)

  • Yoon, Hee-Suk;Hwang, Yun-Chean;Shin, Hyun-Kil;Beak, Cheon-Ki;Yoon, Suck-Min
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.45-49
    • /
    • 1996
  • To determine the utility of spiral computed tomography(CT) in the evaluation of carotid artery stenosis, spiral CT images of 10 patients were compared with both ones of conventional angiography and magnetic resonance(MR) angiography. The severeness of stenosis was determined for each Internal carotid artery on the basis of arterial narrowness : mild stenosis : 40 % or less, moderate stenosis = $40{\sim}70%$, severe stenosis = greater than 70 % of arterial narrowness. The short examination and clear depiction of the arterial lumen In areas of complex or low flow make CT angiography attractive alternative to MR angiography. Spiral CT angiography shows normal and abnormal carotid anatomy well when compared with conventional anglography.

  • PDF

Early Manifestation of Supravalvular Aortic and Pulmonary Artery Stenosis in a Patient with Williams Syndrome

  • Lee, Jong Uk;Jang, Woo Sung;Lee, Young Ok;Cho, Joon Yong
    • Journal of Chest Surgery
    • /
    • v.49 no.2
    • /
    • pp.115-118
    • /
    • 2016
  • Williams syndrome (WS) is a developmental disorder characterized by vascular abnormalities such as thickening of the vascular media layer in medium- and large-sized arteries. Supravalvular aortic stenosis (SVAS) and peripheral pulmonary artery stenosis (PPAS) are common vascular abnormalities in WS. The natural course of SVAS and PPAS is variable, and the timing of surgery or intervention is determined according to the progression of vascular stenosis. In our patient, SVAS and PPAS showed rapid concurrent progression within two weeks after birth. We report the early manifestation of SVAS and PPAS in the neonatal period and describe the surgical treatment for stenosis relief.

Bilateral Superior Cerebellar Artery Infarction after Stent-Angioplasty for Internal Carotid Artery Stenosis

  • Kim, Jung-Hwan;Lee, Jong-Hyeog;Jo, Kwang-Deog;You, Seung-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.239-242
    • /
    • 2013
  • Spontaneous bilateral cerebellar infarction in the territory of the superior cerebellar arteries is extremely rare. Occasionally there have been reports of bilateral cerebellar infarction due to vertebrobasilar atherosclerotic occlusion or stenosis, whereas no report of bilateral cerebellar infarction due to complicated hemodynamic changes. In this report, we present a patient with bilateral cerebral infarctions related to stenoses of bilateral internal carotid arteries, in whom vertebrobasilar system was supplied by multiple collaterals from both posterior communicating arteries and right external carotid artery. We performed stent-angioplasty of bilateral internal cerebral arterial stenosis, and then acute infarction developed on bilateral superior cerebellar artery territories. The authors assumed that the infarction occurred due to hemodynamic change between internal carotid artery and external carotid artery after stent-angioplasty for stenosis of right internal carotid artery.

The Clinical Outcomes of 75 Consecutive Patients with Cervical Carotid Artery Stenosis Treated by Carotid Artery Stenting

  • Chung, Joon-Ho;Shin, Yong-Sam;Lim, Yong-Cheol;Park, Sang-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.6
    • /
    • pp.350-354
    • /
    • 2009
  • Objective : The purpose of this study was to analyze the clinical outcome of 75 consecutive patients with cervical carotid artery stenosis and who were treated by carotid artery stenting (CAS) only. Methods : From February 2003 to June 2008, there were 78 stents placed in 75 symptomatic patients (mean age : 67.3 years); 69 patients had carotid stenosis ${\geq}70%$, and 6 patients had asymptomatic stenosis ${\geq}80%$. No carotid endarterectomy (CEA) was performed during the same period. The patients were clinically followed-up for a mean of 20.1 months. Results : The procedures were technically successful in all cases. Three (3.8%) patients had procedure-related complications. During the 30-day postprocedural period, there were no restenosis or major stroke. Minor stroke was noticed in 3 (3.8%) patients and 1 (1.3%) of the 75 patients suddenly expired 2 days after discharge. There were no new neurological symptoms that developed during the clinical follow-up period. The results of our series were not inferior to those the previously published in CAS studies, and in fact they were better. Conclusion : Our results suggest that CAS may be safe and useful for the treatment of cervical carotid artery stenosis when it is used as the first line treatment in those institutions that lack enough experience with CEA.