• Title/Summary/Keyword: architectural model

Search Result 1,927, Processing Time 0.031 seconds

Existing Building Energy Simulation Method Using Calibrated Model by Energy Audit Data (성능진단 데이터로 보정된 모델을 이용한 기존건축물의 에너지시뮬레이션 기법)

  • Kong, Dong-Seok;Kim, Du-Hwan;Chang, Yong-Sung;Huh, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.231-239
    • /
    • 2014
  • This paper represents a method of existing building energy simulation using energy audit data. Energy audit must be carried out for reasonable analysis, because characteristics of existing buildings such as efficiency of fan, pump, flow rate, pressure, COP and operating schedule could be changed during the building operation. These building characteristics should be measured to estimate actual energy consumption of the existing building. In this study, we conducted energy audit and calculated energy savings for a 7-stories building as a case-study. The energy audit data were used to calibrate the building model of EnergyPlus simulation. Baseline model validated according to M&V guideline index. As a result, building characteristics are significant parameters making a big impact on energy savings in existing buildings.

Computational Soil-Structure Interaction Design via Inverse Problem Formulation for Cone Models

  • Takewaki, Izuru;Fujimoto, Hiroshi;Uetani, Koji
    • Computational Structural Engineering : An International Journal
    • /
    • v.2 no.1
    • /
    • pp.33-42
    • /
    • 2002
  • A computationally efficient stiffness design method for building structures is proposed in which dynamic soil-structure interaction based on the wave-propagation theory is taken into account. A sway-rocking shear building model with appropriate ground impedances derived from the cone models due to Meek and Wolf (1994) is used as a simplified design model. Two representative models, i.e. a structure on a homogeneous half-space ground and a structure on a soil layer on rigid rock, are considered. Super-structure stiffness satisfying a desired stiffness performance condition are determined via an inverse problem formulation for a prescribed ground-surface response spectrum. It is shown through a simple yet reasonably accurate model that the ground conditions, e.g. homogeneous half-space or soil layer on rigid rock (frequency-dependence of impedance functions), ground properties (shear wave velocity), depth of surface ground, have extensive influence on the super-structure design.

  • PDF

A Deep Learning-Based Model for Predicting Traffic Congestion in Semiconductor Fabrication (딥러닝을 활용한 반도체 제조 물류 시스템 통행량 예측모델 설계)

  • Kim, Jong Myeong;Kim, Ock Hyeon;Hong, Sung Bin;Lim, Dae-Eun
    • Journal of Industrial Technology
    • /
    • v.39 no.1
    • /
    • pp.27-31
    • /
    • 2019
  • Semiconductor logistics systems are facing difficulties in increasing production as production processes become more complicated due to the upgrading of fine processes. Therefore, the purpose of the research is to design predictive models that can predict traffic during the pre-planning stage, identify the risk zones that occur during the production process, and prevent them in advance. As a solution, we build FABs using automode simulation to collect data. Then, the traffic prediction model of the areas of interest is constructed using deep learning techniques (keras - multistory conceptron structure). The design of the predictive model gave an estimate of the traffic in the area of interest with an accuracy of about 87%. The expected effect can be used as an indicator for making decisions by proactively identifying congestion risk areas during the Fab Design or Factory Expansion Planning stage, as the maximum traffic per section is predicted.

Proposal for Compressive Strength Development Model of Lightweight Aggregate Concrete Using Expanded Bottom Ash and Dredged Soil Granules (바텀애시 및 준설토 기반 인공경량골재 콘크리트의 압축강도 발현 모델 제시)

  • Lee, Kyung-Ho;Yang, Keun-Hyeok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.7
    • /
    • pp.19-26
    • /
    • 2018
  • This study tested 25 lightweight aggregate concrete (LWAC) mixtures using the expanded bottom ash and dredged soil granules to examine the compressive strength gain of such concrete with different ages. The test parameters investigated were water-to-cement ratios and the natural sand content for the replacement of lightweight fine aggregate. The compressive strength gain rate in the basic equation specified in fib model code was experimentally determined in each mixture and then empirically formulated as a function of the water-to-cement ratio and oven-dried density of concrete. When compared with 28-day compressive strength, the tested LWAC mixtures exhibited relatively low gain ratios (0.49~0.82) at an age of 3 days whereas the gain ratios (1.16~1.41) at 91 days were higher than that (1.05~1.15) of the conventional normal-weight concrete. Thus, the fib model equations tend to overestimate the early strength gain of LWAC but underestimate the long-term strength gain. The proposed equations are in good agreement with the measured compressive strength development of LWAC at different ages, indicating that the mean and standard deviation of the normalized root mean square errors determined in each mixture are 0.101 and 0.053, respectively.

A Feasibility Case Study on Net-Zero Energy Daycare Center (어린이집의 넷 에너지 제로화 구현에 관한 사례분석)

  • Kim, Ji-Hyeon;Lim, Hee-won;Shin, U-cheul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.4
    • /
    • pp.185-192
    • /
    • 2019
  • In this study, we, through case studies, formulated a method to implement net-zero energy daycare center at the current insulation and technology level, and calculated its energy expense. The reference model was a medium sized daycare center whose number of children was 99. We analyzed the energy consumption status for the reference model and developed TRNSYS simulation analytical model to realize net-zero energy . We assumed the reference model to be "All Electric Building" where all energy including cooking is supplied by electricity. The result is summarized as follows: First, the annual electricity consumption of daycare center was 53,291kWh. Plug load occupied the largest share of 48% followed by lighting, 10%, cooling, 9%, cooking, 9%, heating, 8%, hot water, 5% and ventilation, 2%. Second, the photovoltaic installation capacity to realize net-zero energy was 40.32kWp and its annual generation was 53,402kWh. Third, the annual energy expense(electricity bill) by realizing net-zero energy was 2,620,390won.

Probabilistic LCC evaluation for Surface Repair of carbonated RC structure (탄산화된 RC구조물의 표면보수에 대한 확률론적 LCC 평가)

  • Lee, Hyung-Min;Yang, Hyun-Min;Lee, Han-Seung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.41-48
    • /
    • 2018
  • Carbonation is one of the major detrimental factors to the reinforced concrete structures owing to penetration of atmospheric CO2 through the micro pores, thereby it reduces the durability of the concrete. The maintenance periods and cost for concrete according to the coefficient variation of different finishing materials is documented in literature. However, it is required to carry out the systematic and well planned studies. Therefore, keeping them in mind, surface repair was carried out to the carbonated concrete and the maintenance cost was calculated to measure the durability life after repair with different variable. The deterministic and probabilistic methods were applied for durability and repair cost of the concrete. In the existing deterministic model, the cost of repair materials increases significantly when the concrete structure reaches its service life. In present study using a stochastic model, the maintenance period and cost was evaluated. According to obtained results, there was no significant difference in the number of maintenance of the coefficient variation. The initial durability has a great influence on the maintenance time and cost of the structure. Unlike the deterministic model, the probabilistic cost estimating model reduces the number of maintenance to the target service life expectancy.

Anomaly Detection and Diagnostics (ADD) Based on Support Vector Data Description (SVDD) for Energy Consumption in Commercial Building (SVDD를 활용한 상업용 건물에너지 소비패턴의 이상현상 감지)

  • Chae, Young-Tae
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.579-590
    • /
    • 2018
  • Anomaly detection on building energy consumption has been regarded as an effective tool to reduce energy saving on building operation and maintenance. However, it requires energy model and FDD expert for quantitative model approach or large amount of training data for qualitative/history data approach. Both method needs additional time and labors. This study propose a machine learning and data science approach to define faulty conditions on hourly building energy consumption with reducing data amount and input requirement. It suggests an application of Support Vector Data Description (SVDD) method on training normal condition of hourly building energy consumption incorporated with hourly outdoor air temperature and time integer in a week, 168 data points and identifying hourly abnormal condition in the next day. The result shows the developed model has a better performance when the ${\nu}$ (probability of error in the training set) is 0.05 and ${\gamma}$ (radius of hyper plane) 0.2. The model accuracy to identify anomaly operation ranges from 70% (10% increase anomaly) to 95% (20% decrease anomaly) for daily total (24 hours) and from 80% (10% decrease anomaly) to 10%(15% increase anomaly) for occupied hours, respectively.

Thickness of shear flow path in RC beams at maximum torsional strength

  • Kim, Hyeong-Gook;Lee, Jung-Yoon;Kim, Kil-Hee
    • Computers and Concrete
    • /
    • v.29 no.5
    • /
    • pp.303-321
    • /
    • 2022
  • The current design equations for predicting the torsional capacity of RC members underestimate the torsional strength of under-reinforced members and overestimate the torsional strength of over-reinforced members. This is because the design equations consider only the yield strength of torsional reinforcement and the cross-sectional properties of members in determining the torsional capacity. This paper presents an analytical model to predict the thickness of shear flow path in RC beams subjected to pure torsion. The analytical model assumes that torsional reinforcement resists torsional moment with a sufficient deformation capacity until concrete fails by crushing. The ACI 318 code is modified by applying analytical results from the proposed model such as the average stress of torsional reinforcement and the effective gross area enclosed by the shear flow path. Comparison of the calculated and observed torsional strengths of existing 129 test beams showed good agreement. Two design variables related to the compressive strength of concrete in the proposed model are approximated for design application. The accuracy of the ACI 318 code for the over-reinforced test beams improved somewhat with the use of the approximations for the average stresses of reinforcements and the effective gross area enclosed by the shear flow path.

Experimental Study on the Similitude of Small-Scale Models in Cyclic Lateral Behaviors of RC Shear Wall Subassemblages (RC벽식 부분구조의 반복 횡하중 거동에서의 축소모델 상사성 실험연구)

  • Lee, Han-Seon;Cho, Chang-Seok;Lee, Sang-Ho;Oh, Sang-Hoon;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.805-816
    • /
    • 2010
  • For earthquake simulation test it is essential to make sure the similitude in behaviors between the full scale prototype and the reduced scale model. This paper presents the test results obtained through the cyclic lateral-force test, on two-story RC wall subassemblages. A lower 2-story portion of the prototype structure was selected as subassemblages. The global behavior such as the strength and ductility, and the local behavior such as flexural, shear and uplift deformation were measured. The test results of the 3 : 5 scale specimens representing the prototype were compared with those of 1 : 7 scale models. Two types of subassemblages were used: One with lintel beams and one without lintel beams. The comparison shows that 1 : 7 scale model simulated in general successfully the global and local behaviors of the prototype.

Experimental Study and Evaluation of Tension Stiffening Model in High Strength Concrete Beams (고강도 콘크리트 보에서 Tension Stiffening 모델을 이용한 실험적 연구 및 평가)

  • Shin, Dae Hwan;Jo, Eunsun;Kim, Min Sook;Kim, Heechuel;Lee, Young Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.1
    • /
    • pp.45-53
    • /
    • 2014
  • In strength limit states design, it is assumed that after cracking, reinforcement carries all tension in the tension zone of reinforced concrete members. However, it can be seen the concrete between cracks will contribute to carrying a part of the tension stress in actual concrete members particularly at service load levels, this effect is referred as tension stiffening effect. In this study, tension stiffening models and high strength concrete beam flexural test results were verified through comparison. The relationship between moment-curvature and load-deflection was evaluated by result of tension stiffening model and test result values. The analysis results showed that ACI 318 and Owen & Damjanic generally shows good agreement.