• Title/Summary/Keyword: architectural component

Search Result 213, Processing Time 0.027 seconds

- A Case Study on OOP Component Build-up for Reliability of MRP System - (MRP 시스템의 신뢰성을 위한 객체재향 컴포넌트 개발 사례)

  • Seo Jang Hoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.3
    • /
    • pp.211-235
    • /
    • 2004
  • Component based design is perceived as a key technology for developing advanced real-time systems in a both cost- and time effective manner. Already today, component based design is seen to increase software productivity, by reducing the amount of effort needed to update and maintain systems, by packaging solutions for re-use, and easing distribution. Nowdays, a thousand and one companies in If(Information Technology) industry such as Sl(System Integration) and software development companies, regardless of scale of their projects, has spent their time and endeavor on developing reusable business logic. The component software is the outcome of software developers effort on overcoming this problem; the component software is the way propositioned for quick and easy implementation of software. In addition, there has been lots of investment on researching and developing the software development methodology and leading If companies has released new standard technologies to help with component development. For instance, COM(Component Object Model) and DCOM(Distribute COM) technology of Microsoft and EJB(Enterprise Java Beans) technology of Sun Microsystems has turned up. Component-Based Development (CBD) has not redeemed its promises of reuse and flexibility. Reuse is inhibited due to problems such as component retrieval, architectural mismatch, and application specificness. Component-based systems are flexible in the sense that components can be replaced and fine-tuned, but only under the assumption that the software architecture remains stable during the system's lifetime. In this paper, It suggest that systems composed of components should be generated from functional and nonfunctional requirements rather than being composed out of existing or newly developed components. about implements and accomplishes the modeling for the Product Control component development by applying CCD(Contract-Collaboration Diagram), one of component development methodology, to MRP(Material Requirement Planning) System

Development of analytical modeling for an energy-dissipating cladding panel

  • Maneetes, H.;Memari, A.M.
    • Structural Engineering and Mechanics
    • /
    • v.32 no.5
    • /
    • pp.587-608
    • /
    • 2009
  • Modern earthquake-resistant design aims to isolate architectural precast concrete panels from the structural system so as to reduce the interaction with the supporting structure and hence minimize damage. The present study seeks to maximize the cladding-structure interaction by developing an energy-dissipating cladding system (EDCS) that is capable of functioning both as a structural brace, as well as a source of energy dissipation. The EDCS is designed to provide added stiffness and damping to buildings with steel moment resisting frames with the goal of favorably modifying the building response to earthquake-induced forces without demanding any inelastic action and ductility from the basic lateral force resisting system. Because many modern building facades typically have continuous and large openings on top of the precast cladding panels at each floor level for window system, the present study focuses on spandrel type precast concrete cladding panel. The preliminary design of the EDCS was based on existing guidelines and research data on architectural precast concrete cladding and supplemental energy dissipation devices. For the component-level study, the preliminary design was validated and further refined based on the results of nonlinear finite element analyses. The stiffness and strength characteristics of the EDCS were established from a series of nonlinear finite element analyses and are discussed in detail in this paper.

OpenBIM-based Mapping System Development for Geometry Information Exchange of Architectural Components (건축부재 형상정보 교환을 위한 개방형BIM 기반의 매핑 시스템 개발)

  • Park, Seunghwa;Kim, Inhan;Lee, Jiah
    • Korean Journal of Computational Design and Engineering
    • /
    • v.19 no.2
    • /
    • pp.182-190
    • /
    • 2014
  • Parametric modeling is one of BIM's characteristics and BIM have being utilized for constructability analysis, energy efficiency analysis, and so on in diverse construction field. However, parametric information's interoperation is not solved until now because different BIM tools have specific algorithm and methods to generate geometric information. To solve the problem, previous research suggested IFC-XML methodology. In this paper, authors studied connections between IFC-XML structure and script-based modeling commends to make libraries in commercial BIM tools such as ArchiCAD$^{TM}$ and Digital Project$^{TM}$. In addition, they made commends mapping tables to exchange geometry information of architectural components. Moreover, mapping system was developed to certify the mapping tables which is classified modeling commends. Finally, translated architectural component model was confirmed using exchanged geometry information in browser.

Analysis of the Effects of Walking Environment Components on Pedestrian Satisfaction and Dissatisfaction

  • Lee, Meesung;Lee, Heejung;Kim, Taeeun;Hwang, Sungjoo
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.863-870
    • /
    • 2022
  • Unsatisfactory urban walking environment stresses urban residents, and may cause mental illness and chronic diseases by reducing walking activities. Therefore, establishing a high-quality walking environment that can promote walking activities in urban residents has emerged as an important issue. The walking environment consists of various components, such as trees, stairs, streetlights, benches, signs, fences, and facilities, and it is essential to understand which components and their settings act as satisfiers or dissatisfiers for pedestrians, to create a better quality walking environment. Therefore, this study investigated pedestrian satisfaction and dissatisfaction as a function of various environmental components through a survey using walking environment images. The results revealed that most of the walking environment components except the braille block and treezone exhibited significant correlations with pedestrian satisfaction. Particularly, safety-related component (e.g., adjacent roads, parked cars, traffic cushions, and car separation), and landscape-related components (e.g., trees and green), as well as the material settings of landscape facilities (e.g., wooden fences, benches, stairs, and walkway surfaces) correlated with pedestrian satisfaction. The results of this study can contribute to the extraction of useful features to evaluate pedestrian satisfaction as a function of the walking environment. The research outcome is expected to assist in the effective arrangement of walking environment components and their settings, which will ultimately contribute to significantly satisfactory walking environment and encourage walking activities.

  • PDF

Comparison of the Performance of Clustering Analysis using Data Reduction Techniques to Identify Energy Use Patterns

  • Song, Kwonsik;Park, Moonseo;Lee, Hyun-Soo;Ahn, Joseph
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.559-563
    • /
    • 2015
  • Identification of energy use patterns in buildings has a great opportunity for energy saving. To find what energy use patterns exist, clustering analysis has been commonly used such as K-means and hierarchical clustering method. In case of high dimensional data such as energy use time-series, data reduction should be considered to avoid the curse of dimensionality. Principle Component Analysis, Autocorrelation Function, Discrete Fourier Transform and Discrete Wavelet Transform have been widely used to map the original data into the lower dimensional spaces. However, there still remains an ongoing issue since the performance of clustering analysis is dependent on data type, purpose and application. Therefore, we need to understand which data reduction techniques are suitable for energy use management. This research aims find the best clustering method using energy use data obtained from Seoul National University campus. The results of this research show that most experiments with data reduction techniques have a better performance. Also, the results obtained helps facility managers optimally control energy systems such as HVAC to reduce energy use in buildings.

  • PDF

Intelligent Architectural Design Module for Process Automation of Hanok Constructions (한옥 건축공정 자동화를 위한 지능형 설계모듈의 구현)

  • Ahn, Eun-Young
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.9
    • /
    • pp.1156-1164
    • /
    • 2012
  • Hanok is a cultural heritage containing our ancestor's life style intact and breathing alive with us until now. As Hanok has been concerned as a echo-friendly architecture, a new methodology for efficient construction without damaging the traditional construction process comes into request. The goal of this research is development of a architectural design tool based on the BIM(Building Information Modeling) for satisfying these demands. It will be usable to support whole process of the traditional building from digital design to production and construction. Firstly, we take a consideration of the traditional architecture reflecting the spirit of the age and suggest efficient design method for architectural components. Each components is pre-fabricated as a template representing similar components. All pre-fabricated components are designed by object-oriented concepts so, many variations for a component can be derived from the pre-fabricated component. Our method is helpful for reducing design errors because that it considers combining rule between connecting components in the template design. Moreover it is plugged in the commercial architectural CAD, so it can supports digital design not only traditional architecture but also fusion style mixed with modern architecture.

Characteristics of Strength and Durability of Hwangto-Concrete according to its Mixing Condition (황토 콘크리트의 배합조건에 따른 강도성상 및 내구성)

  • Hwang, Hey Zoo;Roh, Tae Hak;Kim, Jin Il
    • KIEAE Journal
    • /
    • v.8 no.5
    • /
    • pp.55-60
    • /
    • 2008
  • The purpose of this study is to increase the use of Hwangto and examine the strength according to what it is compounded with. Hwangto-concrete containing Hwanto without cement nor organic chemical products were compared to the traditional cement concrete through some durability experiments. We expect to gain more knowledge on the potentials of Hwangto-concrete as an architectural source. 1) As Hwangto binder amount rises, the value of slump increases too. The reason is that the increase of the quantity of cement causes the increase of the amount of material and the decrease of the amount of aggregate. 2) When the mixed component into Hwangto-concrete remains at 2%, the compress strength is generally dispersed high along the per unit fission, in case the amount of which is at $400(g/m^3)$. The highest compress strength is 39MPa. It means that it can be applied to common structures and we need to conduct a basic property test to ensure the strength and fluidness. 3) Hwangto-concrete is expected to be highly used in the ocean structure and chemical industry because it has better resistance to sulfuric acid and to hydrochloric acid than the cement-concrete has. The result of this study is as follows. It is expected that Hwangto-concrete will be widely applied and further research on its durability and tests for its basic substantial characteristics based on future component added to it.

Performance Assessment of Building Envelopes II: LightShlef, RetroLux (외피 친환경 성능평가 II: 광선반, RetroLux)

  • Kim, Deuk-Woo;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.83-90
    • /
    • 2009
  • As a series of 'Performance Assessment of Building Envelopes I: Double Skin Facade', three types (interior, exterior, mixed (int.&ext.)) of lightshelves and RetroLux were examined in terms of $CO_2$ emissions. It is shown that the exterior lightshelf could achieve the most energy savings (9.6-38.7%) in general office buildings due to blocking solar radiation before entering the indoor space. However, the interior lightshelf is the worst (1.4-5.2%) among three of them. The RetroLux has two components: (1) sun-reflector (first louver component), (2) light shelf for improving daylight induction (second louver component). Due to these two components, solar radiation from windows is filtered depending on seasonal variation (solar altitude). Therefore, the RetroLux can reduce 18.0-27.9% of annual energy consumption (both cooling and heating), and $552-3,290Won/m^2{\cdot}yr$ of operation cost is saved.

  • PDF

Energy Performance of Air-side Economizer System for Data Center Considering Supply Temperature and Design Airflow Rate of CRAH(Computer Room Air Handler) (외기냉방시스템이 적용된 데이터센터 CRAH의 급기온도와 설계 풍량에 따른 에너지성능 분석)

  • Kim, Ji-Hye;Aum, Tae-Yun;Jeong, Cha-Su
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.11
    • /
    • pp.181-188
    • /
    • 2019
  • The purpose of this study is to evaluate the cooling energy saving effects of CRAH supply air temperature(SAT) and design flow rate changes when applying air-side economizer in the data center. MLC(Mechanical Load Component), which is cooling performance indicator of data center, was used to assess the effectiveness of cooling energy savings. It was computed with energy simulation (DesignBuilder) to evaluate the cooling energy performance of 8 different alternatives in a data center. The MLC was 0.31~0.32 regardless of CRAH supply temperature without air-side economizer, and 0.15 to 0.19 value with air-side economizer. That is, cooling energy can be reduced by approximately 40~55% when applying economizer. As the CRAH SAT and design flow rate changed, the MLC values were 0.16 to 0.18 and 0.15 to 0.19, respectively.

Seismic Design Force for Rectangular Water Tank with Flexible Walls (유연한 벽면을 가진 사각형 물탱크의 설계지진력 산정)

  • Kim, Min Woo;Yu, Eunjong;Park, Ji-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.303-310
    • /
    • 2023
  • The equivalent static load for non-structural elements has a limitation in that the sloshing effect and the interaction between the fluid and the water tank cannot be considered. In this study, the equations to evaluate the impulse and convective components in the design codes and previous research were compared with the shaking table test results of a rectangular water tank with flexible wall panels. The conclusions of this study can be summarized as follows: (1) It was observed that the natural periods of the impulsive component according to ACI 350.3 were longer than system identification results. Thus, ACI 350.3 may underestimate the earthquake load in the case of water tanks with flexible walls. (2) In the case of water tanks with flexible walls, the side walls deform due to bending of the front and back walls. When such three-dimensional fluid-structure interaction was included, the natural period of the impulsive component became similar to the experimental results. (3) When a detailed finite element (FE) model of the water tank was unavailable, the assumption Sai = SDS could be used, resulting in a reasonably conservative design earthquake load.