• 제목/요약/키워드: arched

검색결과 87건 처리시간 0.029초

아치형 단동하우스의 동간거리가 풍력계수에 미치는 영향 (Effects of the Distance between Houses on the Wind Force Coefficients on the Single-span Arched House)

  • 이현우;이석건
    • 한국농공학회지
    • /
    • 제35권4호
    • /
    • pp.76-85
    • /
    • 1993
  • The purpose of this study was to analyze the wind force distribution on the two single-span arched plastic house depending upon the house spacing and wind direction, which may provide the fundamental criteria for the structural design. In order to specify the wind force distribution, the variation of the wind force coefficients, the mean wind force coefficients and the drag force coefficients were estimated from the wind tunnel test data. The results obtained are as follows : 1. At the wind direction of 90$^{\circ}$, there was a typical span interval at which the maximum negative pressure was occured at the edge of the inside walls. 2. In the consideration of wind loads, the wind force coefficients estimated from independent single-span arched plastic house should not be directly applied to the structural design on the double houses separated. 3. The average maximum negative wind force on the inside walls was occured at the wind direction of 90$^{\circ}$, and the variations depending on the span intervals was not significant. 4. The average maximum drag force was occured at the wind direction of 300, and the magnitude of drag force was more significant at the first house. As the distance between two houses was increased, the drag force was slightly increased for every wind direction.

  • PDF

아치형 연동온실의 최적설계를 위한 풍력계수분포도의 분석 (An Analysis of Wind Force Coefficient Distributions for Optimum Design of Multi-Span Arched Greenhouses)

  • 이현우;이석진
    • 한국농공학회지
    • /
    • 제38권2호
    • /
    • pp.145-151
    • /
    • 1996
  • Wind force coefficients of multi-span arched greenhouses with respect to wind direction of $0^{\circ}$ and $30^{\circ}$ were estimated to give more reasonable coefficient. The conventional and subdivided division types of wind force coefficient distribution diagrams were constructed by using the wind tunnel experimental data. Bending moments on the greenhouses were determined through structural analysis using obtained wind force coefficients, and were analyzed. Because actual wind pressure values on a face of greenhouse varied with locations, the more divisions of wind force coefficient distribution were subdivided, the better distribution type was coincided with actual state. In order to calculate the more accurate section force occurred on the arched greenhouse by the wind loads, it was recommendable that the wind force coefficient distribution should take more subdivision type. The maximum bending moment at the multi-span greenhouse frame at wind direction of $30^{\circ}$ was greater than that at O。, therefore the wind force coefficient at inclined wind direction to the wall was needed to be considered for the multi-span greenhouse structural design.

  • PDF

원예시설의 지붕형식에 따른 단면력의 비교분석 (Comparison of Maximum Section Forces of Greenhouse Structures with respect to Roof Types)

  • 이석건;이현우;손정억;이종원
    • 한국농공학회지
    • /
    • 제36권3호
    • /
    • pp.84-89
    • /
    • 1994
  • Section forces of greenhouse structures were studied to suggest basic information for the structural design of greenhouses with respect to roof types and support conditions. Structural analyses were performed for pitched and arched roof, and fixed and hinged support under snow loads and wind loads. Followings are the results obtained and are expected to be useful in determining the span length and roof type in greenhouse design. 1. Special considerations might he required for roof design at the heavy snow region, and for the support design at the strong wind region, respectively. 2. Single-span structure was found to be stronger than multi-span structure under the snow load, but the former was found to be weaker than the latter under the wind load. 3. Arched roof structure was expected to be safer than pitched roof structure if the dimensions and loads were equal. 4. Greenhouse orientation and roof slope should be considered in optimum structural design of grrenhouses, because these two factors are closely related with the influence of wind load and snow load.

  • PDF

A Study on the Ancient Fibulae

  • Kim Moon-Ja
    • The International Journal of Costume Culture
    • /
    • 제8권2호
    • /
    • pp.71-84
    • /
    • 2005
  • Fibulae have been used as clothing fasteners throughout history. They were especially popular with the Celts, but were also used by the Greeks, Romans, Saxons, and Vikings, to name a few. The earliest examples are found in the Mediterranean and Middle East, and date from 800 B. C. and earlier. Their use continues today, in the form of the modern safety pin. The first fibulae of the Bronze Age were very simple, much like modern safety pins. The form of this small functional object varies from simple to extravagant since it is also seen as a piece of jewelry, and is thus subject to the evolution of style. Its size depends on the thick/Jess of the clothing to be attached. Its fabrication demonstrates a great mastery of metal work. Fibulae would vary with the taste and wealth of the wearer. The Fibulae were divided into 10 styles according to the shape, Fibulae with Safety pin shaped style, Penannular shaped style, Animal shaped style, Diamond shaped style, Radiated head shaped style, Horsefly shaped style, Arched bow shaped style, Fan-shaped style, Trumpet shaped style, Arched-fan shaped style.

  • PDF

패조류용 어초의 안정성에 관한 실험적 연구 (An Experimental Study on the Stability of Artificial Reefs for Shellfish and Seaweed)

  • 손병규
    • 한국해양공학회지
    • /
    • 제21권6호
    • /
    • pp.120-124
    • /
    • 2007
  • The purpose of this study was to investigate the stability of the arched and fan types of artificial reefs, which provide habitats for shellfish and seaweed. According to the Froude similitude, parameters affecting the stability of the artificial reefs were analytically, experimentally studied. First, the design parameters of the artificial reefs in wave and current fields were presented. Then, using dimensionless parameters, such as the surf similarity parameter and water particle speed, the stability of the arched and fan types of artificial reefs was investigated. From the hydraulic experiments, it is shown that the stability heavily depends on the way the artificial reefs are installed. Therefore, the installation of the artificial reefs on the surf zone should be carefully executed.

장대 아치교 행어 파단에 의한 동적 해석 (Dynamic Analysis of Long-span Arch Bridge by Fracturing Hangers)

  • 임성순;공민식;유이슬
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.113-120
    • /
    • 2010
  • 장대 아치교 설계 시 시공단계와 완성단계에서 발생할 수 있는 문제에 대하여 검토하고 있으나 케이블 손상에 대한 구조안전성 평가는 매우 미흡한 실정이다. 따라서 본 연구는 공용 중 충돌사고로 인한 행어 파단 시 교량의 구조안전성을 분석하는 것을 연구 목적으로 한다. 이를 위하여 행어 파단에 따른 하중을 충격함수로 이상화하여 동적 해석을 수행하였다. 행어가 파단 되었을 경우 각 행어의 최대 장력은 파단된 행어와 인접한 행어에서 발생한 것으로 나타났으며 정적 하중보다 동적 하중에서 크게 나타났다. 그러므로 장대 아치교의 구조안전성을 확보하기 위해 행어 파단에 따른 충격하중을 동적 하중으로 고려한 해석이 필요하다. 또한 본 연구의 해석 방법 및 결과는 이후 아치교 설계 시 참고자료로 활용될 수 있다.

Coffin-Lowry 증후군 1례 (A case of Coffin-Lowry syndrome)

  • 신정은;서은숙;이동환
    • Journal of Genetic Medicine
    • /
    • 제4권2호
    • /
    • pp.196-199
    • /
    • 2007
  • 발달 지연과 발열과 동반된 경련으로 내원한 12개월 된 남자 환아로 뚜렷하며, 높은 아치를 이룬 눈썹과 넓은 코, 아래를 향하고 있는 눈꺼풀 틈새, 높은 구개, 치아 발육 부전의 특징을 보이는 얼굴 모습을 가졌으며, 통통한 손과, 과신전되며 점점 가늘어지는 손가락, 관절의 움직임이 증가되어있는 특징을 보였다. 이러한 특징에 근거하여 Coffin-Lowry 증후군으로 진단하였으며, 이에 저자들은 Coffin-Lowry 증후군 1례를 경험하여 보고한다.

  • PDF

변단면 변화곡율 캔틸레버 아치의 자유진동 (Free Vibrations of Tapered Cantilever Arches with Variable Curvature)

  • 이병구;이용수;오상진
    • 소음진동
    • /
    • 제10권2호
    • /
    • pp.353-360
    • /
    • 2000
  • Numerical methods are developed for calculating the natural frequencies and mode shapes of the tapered cantilever arches with variable curvature. The differential equations governing the free vibrations of such arches are derived and solved numerically, in which the effect of rotatory inertia is included. The parabolic shape is chosen as the arch with variable curvature while both the prime and quadratic arched members are considered as the tapered arch with variable curvature while both the prime and quadratic arched members are considered as the tapered arch. Comparisons the natural jfrequencies between this study and finite element method SAP 90 seve to validate the numerical method developed herein. The lowest four natural frequencies are reported as a function of four non-dimensional system parameters. The effects of both the rotatory inertia and cross-sectional shape are reported. Also, the typical mode shapes of stress resultants as well as the displacements are reported.

  • PDF

풍하중이 농업시설물의 구조적 안정성에 미치는 영향 -수치해석에 의한 풍력계수분포 산정- (The Effect of Wind Force on Stability of Agricultural Structures - Numerical Calculation of Wind Pressure Coefficients -)

  • 최홍림;손정익
    • 생물환경조절학회지
    • /
    • 제3권1호
    • /
    • pp.10-19
    • /
    • 1994
  • Wind load is known to be one of major forces to influence the stability of agricultural structures. General flow fields were calculated to determine flow characteristics over the envelop of the following three types of greenhouses with arched roof : single span, twin span greenhouses, and two single span greenhouses apart 3m inbetween. Pressure coefficients along the envelop of greenhouse were numerically calculated by the k-$\varepsilon$ turbulence model, which lead to determine wind forces on it. Curvilinear coordinate for an arched roof and the upwind scheme were adopted for the study. The calculated pressure coefficients were validated with the avaliable data of Japanese Standard and NGAM Standard. The Magnitude of calculated forces over the envelop was not in good accordance with data except the windward wall. Even tile data of Japanese and NGAM Standard for validation deviated a lot from each other in quantity and quality. Such discrepancy may be attributed to different geometric and/or flow configuration conditions for experiments, or the insenstivity of the k-$\varepsilon$ turbulence model to recirculation flow.

  • PDF