• Title/Summary/Keyword: arc stability

Search Result 220, Processing Time 0.029 seconds

Relation between Spatter Generation and Waveform factor of $CO_2$ Welding in Short-Circuit Condition ($CO_2$ 용접의 단락이행 조건에서 스패터 발생과 파형인자와의 관계)

  • 김희진;강봉용;이강희;유중돈
    • Journal of Welding and Joining
    • /
    • v.16 no.3
    • /
    • pp.95-101
    • /
    • 1998
  • Waveforms of $CO_2$ gas shielded arc welding in short circuit transfer mode was studied with the waveform analysis program, which can calculate various waveform factors such as number of short circuit event, mean and standard deviation of short circuit time and arc time. The calculated values of these factors were correlated independently or in combination with the spatter generation rate to figure out the most reliable index for evaluating spatter generation and further for arc stability. As a result this study, it was confirmed that the spatter generation tends to decrease with the increase of short circuit frequency. Further to this, it was also found that as the short circuit frequency increases the short circuit event becomes more uniform resulting in the decrease of standard deviations ($\sigma$values) of short circuit time and arc time. This result demonstrated that these factors are strongly correlated with each other and thus any one of these factors can be used for the evaluation index. In the discussion, however, short circuit frequency was proposed for the most practical index in evaluating the arc stability of short circuit transfer mode since it is the one which could be monitored in-process condition without any complex caculation process.

  • PDF

Modelling of Secondary Arc Using EMTP-RV (EMTP-RV를 이용한 2차 아크 모델링)

  • Oh, Yun-Sik;Kang, Sung-Bum;Seo, Hun-Chul;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.937-943
    • /
    • 2012
  • Most of faults occurred in transmission lines are single-phase to ground faults and transient faults. Single-phase auto reclosing is an appropriate scheme to maintain the system stability and restore the system effectively when those faults are occurred. In single-phase auto reclosing scheme, the secondary arc is generated after faulted phase is tripped to eliminate the fault and it is sustained by the capacitive and inductive coupling to the healthy phases. It is important to reclose the faulted phase after fully extinction of secondary arc because of the damage applied to system. Therefore, it is necessary to research on the detection of secondary arc extinction to ensure high success rate of reclosing. In this step, firstly, the accurate modelling of secondary arc should be performed. In this paper, the modelling of secondary arc is performed by using EMTP-RV and the simulation results show that the implemented model is correct and effective.

Voltage Stability Analysis of AC/DC Systems (AC/DC 계통의 전압안정도 해석)

  • Nam, Hae-Kon;Kim, Yong-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.89-91
    • /
    • 1995
  • This paper describes an extension or a pair or multiple load flow solutions and nose curve method developed for voltage stability analysis or AC power systems to AC/DC systems. In this approach the converters are regarded as voltage dependent loads. Assuming that the converters at the unstable (-mode) solution consume the same power equal to the power at the stable (+mode) solution, the unstable solutions or the nose curves arc determined. This method is very efficient since estimating voltage collapse point and voltage stability margin arc determined by a few iterations of multiple load flow solutions. Also the method has the advantages that since the structure or Jacobian matrix is same with that of AC load flow, modal analysis or voltage stability is readily applicable if desired.

  • PDF

Stability Analysis of the Magnetic Structures Producing an M6.5 Flare in active region 12371

  • Kang, Jihye;Inoue, Satoshi;Kusano, Kanya;Park, Sung-Hong;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.41.1-41.1
    • /
    • 2019
  • The stability analysis of coronal magnetic structures is important for studying the initiation of solar flares and eruptions. In order to understand the flare onset process, we first reconstructed the 3D coronal magnetic structures of active region 12371 with an M6.5 flare using a nonlinear force-free field (NLFFF) model based on vector magnetic fields. The NLFFFs successfully produce the observed sigmoidal structure which is composed of two branches of sheared arcade loops. The stability analysis were examined for three representative MHD instabilities: the kink, the torus, and the double arc instabilities. Our stability analysis shows that the two branches of sheared arcade loops are quite stable against the kink and torus instabilities, but unstable against the double arc instability before the flare occurrence. Finally, we discuss a probable onset process of the M6.5 flare.

  • PDF

A Study on the Development of Evaluation Method for the Output Characteristics of Welding Machine by 6$\sigma$ (6$\sigma$에 의한 용접기 출력특성의 평가기법 개발에 관한 연구)

  • 조상명;윤훈성
    • Journal of Welding and Joining
    • /
    • v.21 no.6
    • /
    • pp.26-32
    • /
    • 2003
  • Arc welding process has indicated that it suffers from many flaws. It's because requirement of products is diverse and factors which affects the quality is also various. Therefore, in order to stabilize the welding process, it is important to choose a proper welding machine for the each process, and to evaluate the welding process capability of each machine. In this study, rational and simple index to evaluate the welding machine was set the coefficient of resistance variation through the arc stability examination such as spatter generation weight and bead configuration uniformity etc. And the method to evaluate the process capability index was developed by application of 6$\sigma$.

Quick Judgments of Properties of Fine Aggregate to Use the Electric Arc Furnace Oxidizing Slag

  • Lee, Hyung-Min;Lee, Han-Seung;Choi, Jae-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.5
    • /
    • pp.442-451
    • /
    • 2011
  • Blast furnace slag is recycled as a high value-added material, while steel slag is difficult to recycle or is recycled as a low-grade filler material due to its expansive characteristics. Its property is caused by the high content of free lime and instable steel oxides. Recently, an innovative and rapid cooling method for melting steel slag has been developed in Korea, which reduces free lime content to a minimum level and increases the stability of steel oxides. However, researches on the long-term stability are not sufficient so far. Therefore, this study, focusing on the electric arc furnace oxidizing slag in the steel slag, aims to investigate the properties of the steel slag aggregate, its long-term volume stability and the engineering strength of mortar, and using it as a fine aggregate. This study result indicated that it was possible for it to be used as concrete aggregate because the volume change of the steel slag appeared to be stable.

A Study of Estimation of the Arc Stability in Short-circuition Transfer Region of GMA Welding Using Multi-layer Perceptrons (다층 신경회로망을 이용한 GMA 용접 단락이행영역에서의 아크 안정성 평가)

  • 강문진;이세헌;엄기원
    • Journal of Welding and Joining
    • /
    • v.17 no.5
    • /
    • pp.98-106
    • /
    • 1999
  • In GMAW, the spatters are generated according to the variation of the arc. Of the arc is stable, Few spatters are generated. But if unstable, too many spatters are generated. So, this means the spatters are dependent on the arc state. The aim of this study is to accurately estimate the arc state. To do this, the generated spatters were captured under the some welding conditions, and the waveforms of the arc voltage and welding current were collected. From the collected signals, the waveform factors and their standard deviations were extracted. Using these factors as input parameters of multi-layer artificial neural network, the learning for the weight of the generated spatters is performed and the estimation results to the real spatter are assessed. Obtained results are as follow: the linear correlation coefficient between the estimated result and the real spatters was 0.9986. And although the average convergence error was set 0.002, the estimated error to the real spatter was within 0.1 gr/min at each welding condition. In the estimation for the weight generated spatters, the result with multi-layer neural network was far better than with multiple regression analysis. Especially, even though under the welding condition which the arc state is unstable (the spatter is generated much more), very excellent estimation performance was shown.

  • PDF

Analysis of Hydrological Surface Characteristics using ArcView/Spatial Analyst GIS Extension (ArcView/spatial Analyst GIS 확장 프로그램을 이용한 수리지형 특성인자 분석)

  • Lee, Ki-Won
    • Journal of the Korean earth science society
    • /
    • v.22 no.6
    • /
    • pp.491-499
    • /
    • 2001
  • Generally, several hydrological characteristics which can be obtained from geographic processing in GIS S/W would be utilized to actual hydrological applications such as landslide stability or drainage analysis. Furthermore, by using practical GIS extension programs, it can be possible that automatic extraction task of those information, which was time-consuming and complex processing, is performed as systematical and automatic processing. In this study, using ArcView GIS S/W and its extensions concerning hydrological processing, some waterflow and surface factors in the area of Yemi sheet scaled 1:50,000 were extracted. Then, assessment of landslide stability, determined by DEM-based variables were carried out in order to investigate practical applicability of extension programs. It is thought that several hydrological factors extracted by this study were significant information to predict field model or hydrological hazardous events. It also reveals that landslide potential is overall stable with stability index mapping and S-A plot, with theoretical basis. This methodology can be applicable to other areas related to hydrological characteristics with measurements in fields.

  • PDF

The Effect of Nickel and Nitrogen on Cryogenic Properties of Austenitic Stainless Steel (냉간가공한 오스테나이트계 강재의 극저온 특성에 미치는 Ni 및 N의 영향)

  • 최진일;주기남;강영환
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.1
    • /
    • pp.64-70
    • /
    • 2004
  • Cryogenic characteristics of austenitic stainless steel based on 304 steel with nickel and nitrogen were investigated at room temperature and $-196^{\circ}C$. The alloys were fabricated by vacuum arc furnace and cold working after homogenization treatment. The addition of nickel and nitrogen decreased the stability of $\delta$-ferrite and induced the stability against the formation of martensite to result significantly in enhancing ductility at $-196^{\circ}C$. Nitrogen reduced Md temperature, which was beneficial to the tensile strength and elongation at $25^{\circ}C$ and -196$^{\circ}C$.

The Arc Brazing by Variable Polarity AC Pulse MIG Welding Machine (극성가변 AC 펄스 MIG용접기를 이용한 아크 브레이징)

  • 조상명;공현상
    • Journal of Welding and Joining
    • /
    • v.21 no.4
    • /
    • pp.56-62
    • /
    • 2003
  • MIG brazing is used for many parts without melting base metal because of high productivity. Pulsed MIG brazing can be used to further reduce heat input and to improve the process stability. However, a significant amount of zinc in galvanized sheet steel is burned off in the area of brazes. Therefore, the brazing method to reduce the heat input is needed. In the brazing for galvanized sheet steel, variable polarity AC pulse MIG arc brazing can be applied to more decrease the heat input by setting EN-ratio adequately. In this research, we studied for the variable polarity AC pulse MIG arc brazing to decrease the heat input by using ERCuSi-A wire. As the result of increasing EN-ratio, melting ratio of base metal and burning off of zinc were reduced in galvanized sheet steel.