• Title/Summary/Keyword: arc index

Search Result 213, Processing Time 0.02 seconds

Insights on the rotation measure of the M87 jet on arc-second scales

  • Algaba, Juan-Carlos;Asada, Keiichi;Nakamura, Masanori
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.73.2-73.2
    • /
    • 2014
  • We investigate the rotation measure (RM) of the nearby low luminosity AGN M87 by using archival polarimetric VLA data at 8, 15, 22 and 43 GHz. For the first time, the RM properties of its jet are resolved at at arc-second scales. The distribution of the RM appears to be a gaussian with a mean value of ~200rad/m2 and the power spectrum follows a power law with index -2.5. A simple Kolmogorov model assuming a random turbulent magnetic fields extrinsic to the jet appears not to be adequate to explain the observed RM power spectra. On the other hand, underlying RM gradients possibly connected with the jet could be a possible interpretation.

  • PDF

색인사 연구

  • 박준식
    • Journal of Korean Library and Information Science Society
    • /
    • v.2
    • /
    • pp.23-59
    • /
    • 1975
  • Indexes has not devcloped as an independent branch in library science from the beginning, but it has gradually evolved in a clo~eas sociation with catalog and under the direct influence of the development of publishing pro cesses and of the rapid social changes. Historically, index in the West can be traced back to eariler concordance. On the other hand, index in the Bast does not show a continuous development. It started with book catnlog, but other types of indexing were later 'adopted from the West. Indexing in the West and in the East can be summarized as follows: 1) In the West, Taylor considers Gesner's Pandectae was the first index but the Concordance of the Bible in 1247 was the first true index. Indexing method was first established later in 1545 in Gesner's Partitiones which appeared in three volumes. Classified index appeared after Partitions, but alphabetically ordered index was not developed until th eseventeenth century. The pxiodical index of La France S~auante in 1683 proved -its value, and Poole's An Alphabetical Index in the nineteenth century became the turning point in the development of indexing. After Poole's Index appeared periodical index and book catalog gradually began to be treated separately, and subject index and cross reference were incorporated into indexing. Also dictionary arrangement of the indexed items was adopted in the second half of the nincteenth, century after Charles A. Cutter developed his theory of rules for dictionary catalog and systematic studies of indexing were carried out by many scholars. In the twentieth century, index was mainly developed in the United States of America, especially by Wilson publishing Company. The general trend is to move away from the gcncral index to subject index. Also the ncwspapcr indcx such as The Times I~zdcx is 21 landmark in the history cf indcxing. 2) In China, thcs arc somc cvidcnccs that $Bizgluh(&), $ was the first indcx, but unforlunatcly the book itsclf has not been found as yet.

  • PDF

Dosimetric comparison of coplanar and non-coplanar volumetric-modulated arc therapy in head and neck cancer treated with radiotherapy

  • Gayen, Sanjib;Kombathula, Sri Harsha;Manna, Sumanta;Varshney, Sonal;Pareek, Puneet
    • Radiation Oncology Journal
    • /
    • v.38 no.2
    • /
    • pp.138-147
    • /
    • 2020
  • Purpose: To evaluate the dosimetric variations in patients of head and neck cancer treated with definitive or adjuvant radiotherapy using optimized non-coplanar (ncVMAT) beams with coplanar (cVMAT) beams using volumetric arc therapy. Materials and Methods: Twenty-two patients of head and neck cancer that had received radiotherapy using VMAT in our department were retrospectively analyzed. Each of the patients was planned using coplanar and non-coplanar orientations using an optimized couch angle and fluences. We analyzed the Conformity Index (CIRTOG), Dose Homogeneity Index (DHI), Heterogeneity Index (HIRTOG), low dose volume, target and organs-at-risk coverage in both the plans without changing planning optimization parameters. Results: The prescription dose ranged from 60 Gy to 70 Gy. Using ncVMAT, CIRTOG, DHI and HIRTOG, and tumor coverage (ID95%) had improved, low dose spillage volume in the body V5Gy was increased and V10Gy was reduced. Integral dose and intensity-modulated radiation therapy factor had increased in ncVMAT. In the case of non-coplanar beam arrangements, maximum dose (Dmax) of right and left humeral head were reduced significantly whereas apex of the right and left lung mean dose were increased. Conclusion: The use of ncVMAT produced better target coverage and sparing of the shoulder and soft tissue of the neck as well as the critical organ compared with the cVMAT in patients of head and neck malignancy.

Dosimetric Comparison of Three-Dimensional Conformal, Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Dynamic Conformal Arc Therapy Techniques in Prophylactic Cranial Irradiation

  • Ismail Faruk Durmus;Dursun Esitmez;Guner Ipek Arslan;Ayse Okumus
    • Progress in Medical Physics
    • /
    • v.34 no.4
    • /
    • pp.41-47
    • /
    • 2023
  • Purpose: This study aimed to dosimetrically compare the technique of three-dimensional conformal radiotherapy (3D CRT), which is a traditional prophylactic cranial irradiation method, and the intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques used in the last few decades with the dynamic conformal arc therapy (DCAT) technique. Methods: The 3D CRT, VMAT, IMRT, and DCAT plans were prepared with 25 Gy in 10 fractions in a Monaco planning system. The target volume and the critical organ doses were compared. A comparison of the body V2, V5, and V10 doses, monitor unit (MU), and beam on-time values was also performed. Results: In planned target volume of the brain (PTVBrain), the highest D99 dose value (P<0.001) and the most homogeneous (P=0.049) dose distribution according to the heterogeneity index were obtained using the VMAT technique. In contrast, the lowest values were obtained using the 3D CRT technique in the body V2, V5, and V10 doses. The MU values were the lowest when DCAT (P=0.001) was used. These values were 0.34% (P=0.256) lower with the 3D CRT technique, 66% (P=0.001) lower with IMRT, and 72% (P=0.001) lower with VMAT. The beam on-time values were the lowest with the 3D CRT planning (P<0.001), 3.8% (P=0.008) lower than DCAT, 65% (P=0.001) lower than VMAT planning, and 76% (P=0.001) lower than IMRT planning. Conclusions: Without sacrificing the homogeneous dose distribution and the critical organ doses in IMRTs, three to four times less treatment time, less low-dose volume, less leakage radiation, and less radiation scattering could be achieved when the DCAT technique is used similar to conventional methods. In short, DCAT, which is applicable in small target volumes, can also be successfully planned in large target volumes, such as the whole-brain.

Properties of AlTiN Films Deposited by Cathodic Arc Deposition (음극 아크 증착으로 제조된 AlTiN 박막의 특성)

  • Yang, Ji-Hoon;Kim, Sung-Hwan;Song, Min-A;Jung, Jae-Hun;Jeong, Jae-In
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.3
    • /
    • pp.307-315
    • /
    • 2016
  • The properties of AlTiN films by a cathodic arc deposition process have been studied. Oblique angle deposition has been applied to deposit AlTiN films. AlTiN films have been deposited on stainless steel (SUS304) and cemented carbide (WC) at a substrate temperature of $500^{\circ}C$. AlTiN films were analyzed by scanning electron microscopy, glow-discharge light spectroscopy, micro-vickers hardness, and nanoindenter. When applying a current of 50 A to the cathodic arc source, it showed that the density of macroparticle of AlTiN films was 5 lower than other deposition conditions. With the increase of the bias voltage applied to the substrate up to -150 V, the density of macroparticle was decreased. The change of the $N_2$ flow rate during coating process made no influence on the film properties. For the multi-layered films, the film prepared at oblique angle of $60^{\circ}$ showed the highest hardness of 28 GPa and $H^3/E^2$ index of 0.18. AlTiN films have been shown a good oxidation resistance up to $800^{\circ}C$.

Extraction of Gravity-typed Accessibility Index using Remotely Sensed Imagery and Its Application (위성영상정보의 중력모델기반 접근성지수 추출연계 및 적용)

  • Lee, Kiwon;Oh, Se Gyong;Lee, Bong Gyu
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.6 no.3
    • /
    • pp.61-72
    • /
    • 2003
  • Recently, demands with practical applications using high resolution imagery are increasing, according to addressing new sensor data. Since late 1990s, attempts for application to transportation problems of satellite imagery data have been intensively carried out in US, and these kinds of studies are being categorized into the name of RS-T(remote sensing in transportation). Further, this study is also linked with GIS-T(GIS for transportation), being in the matured stage, and then it contributes to wide uses of remotely sensed imagery. In this study, RS-T is briefly summarized. Later, in order to apply urban transportation analysis with satellite imagery as ancillary data, implementation, as prototyped extension program, for extraction of gravity-typed accessibility indices of transportation geography is performed in the ArcView-GIS environment. It is thought that applied results by two models among implemented models in this study can be utilized to characterize transportation accessibility in a region and to apply as useful statistics related to urban transportation status for regional transportation planning, if time series data are used.

  • PDF

Comparison of Dosimetrical and Radiobiological Parameters on Three VMAT Techniques for Left-Sided Breast Cancer

  • Kang, Seong-Hee;Chung, Jin-Beom;Kim, Kyung-Hyeon;Kang, Sang-Won;Eom, Keun-Yong;Song, Changhoon;Kim, In-Ah;Kim, Jae-Sung
    • Progress in Medical Physics
    • /
    • v.30 no.1
    • /
    • pp.7-13
    • /
    • 2019
  • Purpose: To compare the dosimetrical and radiobiological parameters among various volumetric modulated arc therapy (VMAT) techniques using restricted and continuous arc beams for left-sided breast cancer. Materials and Methods: Ten patients with left-sided breast cancer without regional nodes were retrospectively selected and prescribed the dose of 42.6 Gy in 16 fractions on the planning target volume (PTV). For each patient, three plans were generated using the $Eclipse^{TM}$ system (Varian Medical System, Palo Alto, CA) with one partial arc 1pVMAT, two partial arcs 2pVMAT, and two tangential arcs 2tVMAT. All plans were calculated through anisotropic analytic algorithm and photon optimizer with 6 MV photon beam of $VitalBEAM^{TM}$. The same dose objectives for each plan were used to achieve a fair comparison during optimization. Results: For PTV, dosimetrical parameters such as Homogeneity index, conformity index, and conformal number were superior in 2pVMAT than those in both techniques. $V_{95%}$, which indicates PTV coverage, was 91.86%, 96.60%, and 96.65% for 1pVMAT, 2pVMAT, and 2tVMAT, respectively. In most organs at risk (OARs), 2pVMAT significantly reduced the delivered doses compared with the other techniques, excluding the doses to contralateral lung. For the analysis of radiobiological parameters, a significant difference in normal tissue complication probability was observed in ipsilateral lung while no difference was observed in the other OARs. Conclusions: Our study showed that 2pVMAT had better plan quality and normal tissue sparing than 1pVMAT and 2tVMAT but not for all parameters. Therefore, 2pVMAT could be considered the priority choice for the treatment planning for left breast cancer.

Dosimetric Evaluation of Low-Dose Spillage Volumes for Head and Neck Cancer Using Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Treatment Techniques

  • Kumar, Gourav;Bhushan, Manindra;Kumar, Lalit;Kishore, Vimal;Raman, Kothanda;Kumar, Pawan;Barik, Soumitra;Purohit, Sandeep
    • Progress in Medical Physics
    • /
    • v.32 no.3
    • /
    • pp.70-81
    • /
    • 2021
  • Purpose: This study was designed to investigate the dosimetric difference between intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) in head and neck cancer (HNC). The study primarily focuses on low-dose spillage evaluation between these two techniques. Methods: This retrospective study involved 45 patients with HNC. The treatment plans were generated using the IMRT and VMAT techniques for all patients. Dosimetric comparisons were performed in terms of target coverage, organ-at-risk (OAR) sparing, and various parameters, including conformity index, uniformity index, homogeneity index, conformation number, low-dose volumes, and normal tissue integral dose (NTID). Results: No significant (P>0.05) difference in planning target volume coverage (D95%) was observed between IMRT and VMAT plans for supraglottic larynx, hard palate, and tongue cancers. A decrease in dose volumes ranging from 1 Gy to 30 Gy was observed for VMAT plans compared with those for IMRT plans, except for V1Gy and V30Gy for supraglottic larynx cancer and V1Gy for tongue cancer. Moreover, decreases (P<0.05) in NTID were observed for VMAT plans compared with that for IMRT plans in supraglottic larynx (4.50%), hard palate (12.80%), and tongue (7.76%) cancers. In contrast, a slight increase in monitor units for VMAT compared with those for IMRT in supraglottic larynx (0.46%), hard palate (2.54%), and tongue (7.56%) cancers. Conclusions: For advanced-stage HNC, both IMRT and VMAT offer satisfactory clinical plans. VMAT offers a conformal and homogeneous dose distribution with comparable OAR sparing and higher dose falloff outside the target volume than IMRT, which provides an edge to reduce the risk of secondary malignancies for HNC over IMRT.

Mapping of Cone Index for Precision Tillage (정밀 경운을 위한 원추지수 지도 작성)

  • Chong B. H.;Park Y. J.;Park H. K.;Park S. B.;Kim K. U.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.2 s.109
    • /
    • pp.127-133
    • /
    • 2005
  • Precision tillage is designed to till lands variably according to their firmness. Therefore, it is necessary to measure soil firmness in fields and present it in a form with which the variable tillage on be performed. Such forms may be classified into two categories: sensor-based and map-based forms. The map-based approach appears to be inevitable until the technology develops high enough to secure the sensor-based approaches. The first step for map-based precision tillage may be to develop a tillage recommendation map. In this study, a tractor-mountable automatic soil firmness measurement system was developed to construct a cone index map. The system is comprised of three ASAE Standard cone penetrometers and a hydraulic unit for controlling operation of the penetrometers. The system is designed to conduct stop-and-go measurements in fields. The measurements from the three penetrometers are transferred to a microcomputer and the average cone index was calculated. This average cone index was taken as soil firmness of the location where the measurement was made. The cone indices thus determined were used to construct a cone index map using the ArcView software. The system also displays the soil penetration resistance, cone index and soil depth as the cone penetrates into the soil. The field performance of the system was evaluated and the cone index maps at different depths were also presented.

A Study on the Longevity Index and the Criteria of Longevity in Rural Area for Aged Society (노령화사회에 대비한 농촌지역 장수도의 정의 및 장수지역 기준마련에 관한 연구)

  • Jung, Nam-Su;Lee, Jeong-Jae;Kim, Han-Joong;Lee, Gi-Min;Seo, Kyo;Lee, Ho-Jae
    • Journal of Korean Society of Rural Planning
    • /
    • v.9 no.3 s.20
    • /
    • pp.35-39
    • /
    • 2003
  • In this study, the longevity index was suggested for researches about social and environmental effects to human immorality and criteria for defining longevity area were developed using statistical analysis. Candidates indexes based on researches about the tend of human death ratio were investigated. As a result statistical analysis, ratio of population over 85 yearn old and over 65 years was selected as a longevity index. Statistical analysis on the longevity distribution at each district showed that 'eup' and 'myun' are appropriate spatial unit to study social and geographical characteristics of longevity. The spatial analysis using the $ArcView^{TM}$ with the suggested index shows the time dependent variances of degree of immorality and spatial relationship between degree of immorality and human migration.