• Title/Summary/Keyword: applicator

Search Result 161, Processing Time 0.032 seconds

Measurement of Operator Exposure During Treatment of Fungicide Difenoconazole on Grape Orchard (포도 과수원에서 살균제 Difenoconazole의 농작업자 노출량 측정)

  • Cho, ll Kyu;Park, Joon Seong;Park, So Hyun;Kim, Su Jin;Kim, Back Jong;Na, Tae Wong;Nam, Hyo Song;Park, Kyung Hun;Lee, Jiho;Kim, Jeong-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.4
    • /
    • pp.286-293
    • /
    • 2016
  • BACKGROUND: 18% of difenoconazole+iminoctadin triacetate microemulsion (3%+15%) formulation were mixed and sprayed as closely as possible to normal practice on the ten of farms located in the Youngju of South Korea. Patches, cotton gloves, socks, masks and XAD-2 resin were used to measure the potential exposure for applicators wearing standardized whole-body outer and inner dosimeter (WBD). This study has been carried out to determine the dermal and inhalation exposure to difenoconazole during preparation of spray suspension and application with a power sprayer on a grape orchard. METHODS AND RESULTS: A personal air monitor equipped with an air pump IOM sampler and cassette and glass fiber filter were used for inhalation exposure. The field studies were carried out in a grape orchard. The temperature and relative humidity were monitored with a thermometer and a hygrometer. Wind speed was measured using a pocket weather meter. All mean field fortification recoveries were between 97.3% and 119.6% in the level of 100 LOQ (limit of quantification) while the LOQ for difenoconazole was $0.025{\mu}g/mL$ using HPLC-UVD. The arms exposure to difenoconazole for the mixer/loader (0.0794 mg) was higher than other body parts (head, hands, upper body, legs). The exposure to difenoconazole in the legs for applicator (3.78 mg) was highest in the parts of body. The dermal exposure for mixer/loader and applicator were 0.02 and 2.28 mg on a grape orchard, respectively. The inhalation exposure during application was estimated as 0.02 mg. The ratio of inhalation exposure to dermal exposure was equivalent to 0.9% of the dermal exposure. CONCLUSION: The inhalation exposure for applicator indicated $18.8{\times}10^{-3}mg$, which was level of 0.9% of the dermal exposure (2.28 mg). Operator exposure (0.004 mg/kg bw/day) to difenoconazole during treatment for grape is calculated as 2.5% of the established AOEL (0.16 mg/kg bw/day).

Risk Assessment of Operator Exposure During Treatment of Fungicide Dithianon on Apple Orchard (사과 과수원에서 농약살포시 살균제 Dithianon의 농작업자 위해성 평가)

  • Cho, ll Kyu;Kim, Su Jin;Kim, Ji Myung;Oh, Young Goun;Seol, Jae Ung;Lee, Ji Ho;Kim, Jeong Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.302-311
    • /
    • 2018
  • BACKGROUND: Dithianon (75%) formulation were mixed and sprayed as closely as possible by normal practice on the ten farms located in the Mungeong of South Korea. Patches, cotton gloves, socks, masks, and XAD-2 resin were used for measurement of the potential exposure of dithianon on the applicators wearing standardized whole-body outer and inner dosimeter (WBD). This study has been carried out to determine the dermal and inhalation exposure to dithianon during preparation of spray suspension and application with a power sprayer on a apple orchard. METHODS AND RESULTS: A personal air monitor equipped with an air pump, IOM sampler and cassette, and glass fiber filter was used for inhalation exposure. The field studies were carried out in a apple orchard. The temperature and relative humidity were monitored with a thermometer and a hygrometer. Wind speed was measured using a pocket weather meter. All mean field fortification recoveries were between 85.1% and 99.1% in the level of 100 LOQ (limit of quantification), while the LOQ for dithianon was $0.05{\mu}g/mL$ using HPLC-DAD. The exposure to dithianon on arms of the mixer/loader (0.0794 mg) was higher than other body parts (head, hands, upper body, or legs). The exposure to dithianon on the applicator's legs (3.78 mg) was highest in the body parts. The dermal exposures for mixer/loader and applicator were 10 and 8.10 mg, respectively, from a grape orchard. The inhalation exposure during application was estimated as 0.151 mg, and the ratio of inhalation exposure was 11.2% of the dermal exposure (inner clothes). CONCLUSION: The dermal and inhalation exposure on the applicator appeared to be 4.203 mg - 25.064 mg and $0.529{\mu}g-116.241{\mu}g$, respectively. The total exposures on the agricultural applicators were at the level of 2.596 mg - 25.069 mg to dithianon during treatment for apple orchard. The TER showed 3.421 (>1) when AOEL of dithianon was used as a reference dose for the purpose of risk assessment of the mixing/loading and application.

Dose Characteristics by the Co-60 Source Oscillations in High Dose Rate After Loading Irradiations (고선량율 원격강내조사의 코발트-60 이동선원에 의한 선량특성)

  • 최태진;김옥배;노홍균
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.51-60
    • /
    • 1990
  • Dose distributions around Co- 60 moving source in high dose rate remote afterloading unit, Buchler 3K unit, were experimented with X-omat V films and calculations. In our experiments, film dosimetries have achieved to evaluated the axial dose distributions for source oscillations were 0, 3.5, 5.0 and 6.0 cm in periodically, In results, the dose distributions in axial of source movement showed apparently higher than in transverse direction caused by source locations, dwelling time and air gap in the applicator. In the calculations, the dose rate was derived by using the inverse square law, filteration corrections and Meisberger constant for scatter corrections as source movings. In our experiments and calculations, the average dose uncertainties were showed -2.1$\pm$1.9% in fixed sourdce, -2.9$\pm$1.8%, -7.4$\pm$6.1% and -6.7$\pm$4.6% at 3.5 cm, 5.0 cm and 6.0 cm source oscillations, but the calculations have showed very close to experimental dose rate within 4 cm distance from source.

  • PDF

AN EVALUATION OF RADIATION DOSES RESULTING FROM THE MEDICAL USE OF HIGH-ENERGY BETA-RAY SOURCES

  • Park, Jae-Woo;Kim, Hyun-Jo
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.149-154
    • /
    • 2001
  • Calculational models to evaluate radiation doses resulting from the medical use of high energy beta-ray sources are presented. The radioactive sources considered are Sr-90/Y-90 used as ophthalmic applicator, Re-188 used for treating restenosis of coronary artery, and Ho-166 used for treating hepatic tumors. Typical therapeutic situations which might induce relatively high radiation doses the medical person involved were considered to compute by using MCNP-4C Monte Carlo code the radiation doses. The calculation results suggest that for all of the cases considered, the evaluated radiation doses are negligible compared to the dose limits. It is also found that the effect of Bremsstrahlung radiations on the total dose is insignificant, and hence the conventional lead gown is also effective in shielding beta-rays.

  • PDF

Measurement of Bremsstrahlung Radiation with Electron Beam Energy

  • Srivastava, R.P.;Chaurasia, P.P.;Prasiko, G.;Jha, A.K.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.235-236
    • /
    • 2002
  • A Klystron powered dual photon energy electron linear accelerator 2300 C/D from Varian Associates has been installed in our center. From the radiological safety view as well as treatment planning, the output (contamination) of Bremsstrahlung Radiation with electron beam energy determined accurately. It has been found 0.5% to 4.7% with increasing the electron beam energy which is the clinically not much significant in the treatment of the malignant diseases with the treatment of electron beam.

  • PDF

A Study on the Water Sterilizer using the Microwave (마이크로파를 이용한 물 살균장치에 관한 연구)

  • 이창호;이화용
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.113-117
    • /
    • 2004
  • In this paper, we present a new microwave applicator to sterilize a liquid material by using the electromagnetic energy. Also, we conducted an experiment on streamlet water with our proposed sterilizer and investigated the chosen samples according to the inspection agency The result exhibited that the total number of colitis germ and general bacillus in sterilized water has been decreased rapidly as the operating time to illuminate the microwave power risen from 10 to 60 seconds.

NUMERICAL SIMULATION OF THE EFFECTS OF RESIN SUPPLY TEMPERATURE ON OPTICAL FIBER COATING THICKNESS (피복재 공급온도가 광섬유 피복두께에 미치는 영향에 대한 전산유동해석)

  • Choi, J.S.;Kwak, H.S.;Kim, K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.96-99
    • /
    • 2011
  • Fiber coatings are essential in optical fiber manufacturing, since they provide the protective layers from the surface damages and the adequate fiber strength. Flow and temperature fields of coating liquid in a fiber coating applicator are numerically investigated by using a commercial CFD software. The main focus of this computational study is on the thermal effects by viscous dissipation and the effects of coating supply temperature on the final fiber coating thickness. The numerical results reveal that the thermal effects play a major role in the high-speed optical fiber coating process and give substantial influences on the determination of coating thickness. Changing the supply temperature of coating liquid is found to relieve the radial variation of coating liquid viscosity in the coating die and it can be an effective way to control the fiber coating thickness.

  • PDF

Applicator Exposure Assessment During Thiophanate-methyl Treatment in Apple Fields

  • Moon, Joon-Kwan;Kim, Jeong-Han
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.10a
    • /
    • pp.35-35
    • /
    • 2003
  • Korea has different agricultural pattern from western countries and in particular, pesticide application has been performed by individual farmer. Such situations can result in pesticide exposure to worker at significant level. Thiophanate-methyl is a benzimidazole fungicide, which has been used for the wide range of fungal pathogens in field crops and fruits in Korea. It is insoluble In water, and is stable in neutral, aqueous solution at room temperature. It is a carbendazim precursor and systemic fungicide with protective and curative action. Toxicity to mammalian is low as ADI value is 0.08mg/kg b.w. (Tomlin 2000).

  • PDF

Aerodynamic Properties of Granular Agrichemicals (입제 비료 및 농약의 공기역학적 성질)

  • 이성호;이중용;정창주;이채식
    • Journal of Biosystems Engineering
    • /
    • v.23 no.2
    • /
    • pp.105-114
    • /
    • 1998
  • Granule application with a boom has merits of accurate application and high field efficiency. In order to develop a boom granule applicator, aerodynamic properties of agrichemicals should be investigated. This study was accomplished to investigate aerodynamic properties of granules and factors affecting on them. The tested agrichemicals were urea, compound fertilizer (17-21-17), sand and zeolite. Basic physical properties of granules such as true density, sphericity, and arithmetic mean diameter for those materials were analyzed. Regression equations for pickup velocity (v$_{p}$) and saltation velocity (v$_{s}$) were proposed by the data transformation and the multi-regression analysis as follows : (equation omitted) where, 0< s < 1, 0< λ$_{i}$< 3, 35 < D/d$_{p}$ < 350, 1000 $_{p}$/p$_{a}$ < 2500 The range of pickup velocity of fertilizers and other agrichemicals were shown to be 10-16m/s and 9-13m/s, respectively. The saltation velocity of fertilizer and other agrichemicals were 3 m/s and 4 m/s, respectively.y.ively.y.y.

  • PDF

Flow Characteristics of Injected Concentrates in Spray Booms (주입식 붐 방제기의 농약 혼합 유동특성)

  • 구영모;스티븐영;데니스쿨만
    • Journal of Biosystems Engineering
    • /
    • v.21 no.2
    • /
    • pp.146-154
    • /
    • 1996
  • 농약의 직주입 혼합방식은 작업자의 안전에 기여하며 남은 농약은 용기와 함께 수거되어 재사용 되므로 환경보전 및 경제적 이점이 있다. 그러나 주입식 방제기의 분관내 농약혼합액이 노즐에 이르는 시간까지의 유동특성인 지연시간은 농약 살포량에 오차를 유발한다. 본 연구는 이 지연시간이 미치는 실제 살포오차의 정도를 파악하려 시뮬레이션을 행하였다. 시뮬레이션의 결과에 의하면 오차는 상당히 심각한 것으로 판단되었으며 지연시간을 단축하려는 여러 방법을 검토하였다. 분관의 직경을 줄여 유동속도를 빠르게 하거나, 혼입 농약의 양을 일정하게 유지하며 방제속도를 가능한 목표속도에 맞추는 방법 등은 약간의 오차를 줄일 수 있을 뿐이었고, 농약을 각 노즐에 주입함으로써 오차를 최소화할 수 있으나 미소계략의 문제를 내포하였다. 따라서 농도의 변화에 따른 지연시간을 없앤 직주입 총유량 제어방식을 통하여 노즐 배출유량을 방제속도의 변이에 따라 보상하며 비례적으로 농약을 주입하여 농도를 일정하게 유지할 수 있을 것으로 판단된다.

  • PDF