• Title/Summary/Keyword: applicator

Search Result 161, Processing Time 0.029 seconds

Spray and Depositional Characteristics of Electrostatic Nozzles for Orchard Sprayers (과수 방제기용 정전대전 노즐의 분무 및 부착특성)

  • 강태경;이동현;이채식;이공인;최완규;노수영
    • Journal of Biosystems Engineering
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2004
  • Spraying is one of the most efficient methods for pesticide and insecticide control. Generally, orchard sprayers(aircarrier sprayer) are used for such applications. However, when an orchard sprayer is used, only 20% of total amount of spray deposits on the target. The rest of spray are not only wasted but are also potential sources of environmental pollution. The research far the development of electrostatic spraying system for orchard sprayer was conducted to develop the new pesticide application technology for the reduction of environmental pollution and f3r the production of safe agricultural products. The spray characteristics for nozzles with the different charging methods were tested and the effect of electrostatic charge was analyzed, in the laboratory experiments. The results of this study indicate that the capacitive type of electrostatic spraying nozzle exhibits a large current deposition of water sprays on the sample target. The covering area ratio by conventional spraying system was 10.2%, while that of electrostatic sprays with pulse induction charging method gave the increased covering area ratio by 4.3 times.

Quality Assurance for High Dose Rate Brachytherapy (고선량율 근접치료의 정도관리)

  • Bang, Dong-Wan;Cho, Chung-Hee;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.30-44
    • /
    • 1998
  • Accurate delivery of doses using a high dose rate(HDR) brachytherapy, remote afterloading system(RALS) depends on knowing the strength of the radioactive source at the time of treatment, the precision and consistency of the timer, and the ability of the unit to position the source at the proper dwell location along the applicator. Periodic Quality Assurance(QA) on HDR machines is a part of the standard protocol of any user. The safety of the patient & staff, positional accuracy, temporal accuracy, and dose delivery accuracy are periodically(weekly, quarterly, monthly) estimated using HDR source(Ir-192), treatment planning devices, measurement devices, and overall treatment devices with regard to treatment delivery. The overall measurement results are estimated successfully and assessed its clinical significance. As a result, our HDR brachytherapy units has been very accurate until now. The QA program protocol permits routine clinical use and provides a high confidence level in the accurate operation of HDR units. Therefore, regular QA of HDR brachytherapy is essential for successful treatment.

  • PDF

CLINICAL STUDY OF DESENSITIZER FOR TREATMENT OF DENTINAL HYPERSENSITIVITY (상아질 지각과민 처치제의 임상적 효과에 대한 연구)

  • Cho, Kyung-Mo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.219-224
    • /
    • 2000
  • The purpose of this study is for evaluating the effect of MS Coat desensitizing agent in clinical situation. In this study total 60 teeth of 30 patients who is feeling hypersensitivity after periodontal surgery were treated with MS Coat desensitizing agent, and 20 teeth with saline solution for placebo effects and evaluated. All teeth were cleaned with rubber cup and pumice, after then the antibacterial agent was applied for 20 seconds and simply isolated using cotton roll Desensitizing agent was applied with a specific instrument in the manufacturers package by abrading motion for 10 seconds and re-done 8 times. Tactile stimulus with sharp explorer, air stimulus with syringe of dental unit, $7^{\circ}C$ cold water stimulus using micropipette applicator was done to evaluate hypersensitivity before apply test agent, immediate after application, 1 week after, and 3 month after application. The degree of hypersensitivity was recorded using 100mm Visual Analogue Scale and compared between group and evaluation times. From this clinical study sensitivity to the stimulus was significantly induced in both groups and MS Coat made a significant reduction in VAS score than placebo group did(p<.01). The results of this study could demonstrate that MS Coat desensitizing agent can use effectively to heat dentinal hypersensitivity.

  • PDF

Root-zone Placement of Carbofuran for Control of Rice Insect Pests (Carbofuran 수도근계처리의 해충방제효과)

  • Ryu J. K.;Choi S. Y.;Lee H. R.;Song Y. H.
    • Korean journal of applied entomology
    • /
    • v.16 no.4 s.33
    • /
    • pp.217-220
    • /
    • 1977
  • During 1976 the effects of carbofuran placement in the root zone of the rice plants, the varieties Palkweng and Yushin, were evaluated for control of common rice pests in the paddy field at the Honam Crops Experiment Station. The methods of insecticide placement included the use of capsule formulation and liquid injection by the root-zone liquid insecticide injector designed at the International Rice Research Institute. The single ro~t-zone application of carbofuran at 2 days after transplanting was compared with two and fcur broadcast applications of carbofuran and diazinon. Capsules were the most. effective in controlling the striped rice borer (Chilo suppressalis), small brown plant-hopper (Laodelphax striatellus), green rice leafhopper (Nephotettix cincticeps) and stripe virus disease which is transmitted by the small brown planthopper. However, one injector application of carbofuran was equal or better the broadcast applications. Their control effectiveness were more significant on Palkweng susceptible to common rice pests than on Yushin resistant to the stripe virus disease.

  • PDF

Development of a Rapeseed Seeder Attached to Tractors (트랙터 부착용 유채파종기 개발)

  • Lee, C.K.;Choi, Y.;Jun, H.J.;Choi, D.K.;Kim, Y.J.;Lee, S.K.;Moon, S.D.;Han, B.H.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.3
    • /
    • pp.147-154
    • /
    • 2009
  • Suitable rapeseed cultivation techniques of domestic agriculture are essential for stable security, supply and demand of rapeseed. This research developed a rapeseed seeder for bio-diesel and analyzed the seeding performance improving an existent granule fertilizer applicator. The relational expression of metering groove size and discharge rate per time displayed high correlation with a coefficient of determination of 0.988. Also, the scattering types were analyzed by forwarding speed and discharge rate. Validity application width was decided as 7.0 m by analyzing application uniformity at application widths of 7.6 m, 6.6 m, 5.6 m. All average coefficients of variation values were less than 20%. The best application uniformity was obtained in the condition of a work speed of 1.3 m/s and a sowing rate of 19.0 g/s. It was better average coefficient of variation values under 10% at superposition application of rapeseed seeder. Also, scattering amount rates of right and left were within 0.89${\sim}$1.0.

Development of Paste Fertilizer for Rice -II. Effect of Paste Fertilizer on Rice (측조시비기용(側條施肥機用) 호상비료개발(糊狀肥料開發)에 관(關)한 연구(硏究) -II. 수도(水稻)에 대한 비효시험)

  • Seong, Ki-Seog;Shin, Jae-Sung;Kwak, Yong-Ho;Kim, Bok-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.20 no.1
    • /
    • pp.7-10
    • /
    • 1987
  • This study was conducted to evaluate the effect of a newly developed paste fertilizer on rice growth. It was applied to two vars. of Taeback and Cheonma byeos as a basal treatment. It needs a unique applicator attached to transplant machine for rice plant and was injected about 3cm depth of paddy soils. The polished rice yields were obtained competitively with a 20 percent reduction of N applied with top dressing. Plant development treated paste fertilizer was good compared to control at the early growing stage, however, not different at the late growing stage. Nitrogen uptake in plant was high at the early growing stage in paste fertilizer treatment but there were no significant difference at the late growing stage.

  • PDF

Prospective of Sustainable Agriculture in Korea (친환경 농업기술의 발전방향)

  • 류순호
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1999.06a
    • /
    • pp.137-159
    • /
    • 1999
  • Over the last three decades, Korean farming system has been directed to maximum agricultural production and to increase farmer's income through adoption of high-yielding crop varieties and high input of agrochemicals . These farming practices have resulted in problems of water-quality deterioration, soil degradation , and food safety. At present, over 40 million tones of animal waste are bing produced annually, which amounts to disposing the waste at the annual rate of 20 tones per ha in the total area of farming land in Korea. Nearly a half of total available water resources is used as irrigation water predominantly for rice paddy field. Thus, non-point source contamination of the water resources has been linked to agriculture across the nation. However, the extent to which agriculture contributes to the water quality is not fully known. Recently, Korean government provided various institutional measures to reduce the negative impacts of agricultural practices on the environ ental quality, and the Agricultural Environment Act was also passed by the legislature in 1998 and became effective January 1999. This Act does not cover the broad spectrum of the sustainable agriculture ; thus, the limited incentives within this Act are arguably ineffective to control the non-point source pollution. Recently new bulk blending of fertilizers(BB fertilizer) are bing produced (100, 000 tones in 1998) with Government subsidies. The BB fertilizers are to balance N-P-K ratio in the soils . Although the use of the BB fertilizers are encouraged with Government subsidies, non-point source pollution is still serious and will become worse. Precision farming is regarded as a new means for sustainable agriculture. It is a new technology that modifies the existing techniques and incorporates new one such as GIS, GPS , differential applicator to produce a new set of tools for the farmer to use. Precision farming, however, has constraints for individual farming practices. For exam le , farm size or parcel unit of each farmer is too small to adopt the precision agriculture on farmhouse-hold bases and farmer's ability to adopt the new technology is limited. However, it would be appropriate to establish local or regional cooperatives to operate such a precision farming system. It is recommended that Government provide sufficient incentives to help establish local and/or regional cooperatives.

  • PDF

Assessment of Dose Distribution using the MIRD Phantom at Uterine Cervix and Surrounding Organs in High Doserate Brachytheraphy (자궁주위 방사선 근접치료시 MIRD 팬텀을 이용한 주변장기의 피폭환경평가)

  • Lee, Yun-Jong;Nho, Young-Chang;Lee, Jai-Ki
    • Korean Journal of Environmental Biology
    • /
    • v.24 no.4
    • /
    • pp.387-391
    • /
    • 2006
  • Computational and experimental dosimetry of Henschke applicator with respect to high dose rate brachytherapy using the MIRD phantom and a remote control afterloader were performed. A comparison of computational dosimetry was made between the simulated Monte Carlo dosimetry and GAMMADOT brachytherapy Planning system's dosimetry. Dose measurements was performed using ion chamber in a water phantom. Dose rates are calculated using Monte Carlo code MCNP4B and the GAMMADOT. Thecomputational models include the detailed geometry of Ir-192 source, tandem tube, and shielded ovoids for accurate estimation. And transit dose delivered during source extension to and retraction from a given dwell position was estimated by Monte Carlo simulations. Point doses at ICRU bladder/rectal pointswhich have been recommened by ICRU 38 was assessed. Calculated and measured dose distribution data agreed within 4% each other. The shielding effect of ovoids leads to 19% and 20% dose reduction at bladder surface and rectal points.

A Study on clinical Considerations caused by inevitably Extended SSD for Electron beam therapy (확장된 SSD에 기인한 Electron beam의 Output 및 특성 변화에 관한 연구)

  • Lee, Jeong-U;Kim, Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.29-35
    • /
    • 1996
  • We are often faced with the clinical situations that is inevitably extended SSD for electron beam therapy due to anatomical restriction or applicator structure. But there are some difficulties in accurately predicting output and properties. In electron beam treatment , unlike photon beam the decrease in output for extended SSD does not follow inverse-square law accurately because of a loss of side scatter equilibrium, which is particularly significant for small cone size and low energies. The purpose of our study is to analyze the output in changing with the energy, cone size, air gap beyond the standard SSD and to compare inverse-square law factor derived from calculated effective SSD, mominal SSD with measured output factor. In addition, we have analyzed the change of PDD for several cones with different SSDs which range from 100cm to 120cm with 5cm step and with different energies(6MeV, 9MeV, 12MeV, 16MeV, 20MeV). In accordance with our study, an extended SSD produces a significant change in beam output, negligible change in depth dose which range from 100cm to 120cm SSDs. In order to deliver the more accurate dose to the neoplastic tissue, first of all we recommend inverse-square law using the table of effective SSDs with cone sizes and energies respectively or simply to create a table of extended SSD air gap correction factor. The second we need to have an insight into some change of dose distribution including PPD, penumbra caused by extended SSD for electron beam therapy.

  • PDF

Increased Sister Chromatid Exchange in Peripheral Blood Lymphocytes from Humans Exposed to Pesticide: Evidence Based on a Meta-analysis

  • Yang, Hai-Yan;Liu, Jing;Yang, Si-Yu;Wang, Hai-Yu;Wang, Ya-Dong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9725-9730
    • /
    • 2014
  • Background: Sister chromatid exchange (SCE) in human peripheral blood lymphocytes is one of the most extensively studied biomarkers employed to evaluate genetic damage subsequent to pesticide exposure. Objective: To estimate the pooled levels of SCE in human peripheral blood lymphocytes among population exposed to pesticide. Materials and Methods: Meta-analysis on the association between SCE frequency and pesticide exposure was performed with STATA 10.0 software package and Review Manager 5.0.24 in this study. Results: The overall means of SCE were 7.88 [95% confidence intervals (95%CI): 6.71-9.04] for exposure group and 6.05 (95%CI: 5.13-6.95) for controls, respectively. There was statistically significant difference in the SCE frequency in human peripheral blood lymphocytes between pesticide-exposed groups and control groups, and the summary estimate of weighted mean difference was 1.69 (95%CI: 1.01-2.38). We also observed that pesticide-exposed population had significantly higher SCE frequency than control groups among smokers, nonsmokers, pesticide applicator, pesticide producer, other exposure population and Asian population in stratified analyses. Conclusions: Data indicate that the SCE frequency in human peripheral blood lymphocytes might be an indicator of early genetic esffects for pesticide-exposed populations.