• Title/Summary/Keyword: applicator

Search Result 161, Processing Time 0.026 seconds

Utrecht Interstitial Applicator Shifts and DVH Parameter Changes in 3D CT-based HDR Brachytherapy of Cervical Cancer

  • Shi, Dan;He, Ming-Yuan;Zhao, Zhi-Peng;Wu, Ning;Zhao, Hong-Fu;Xu, Zhi-Jian;Cheng, Guang-Hui
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3945-3949
    • /
    • 2015
  • Background: For brachytherapy of cervical cancer, applicator shifts can not be avoided. The present investigation concerned Utrecht interstitial applicator shifts and their effects on organ movement and DVH parameters during 3D CT-based HDR brachytherapy of cervical cancer. Materials and Methods: After the applicator being implanted, CT imaging was achieved for oncologist contouring CTVhr, CTVir, and OAR, including bladder, rectum, sigmoid colon and small intestines. After the treatment, CT imaging was repeated to determine applicator shifts and OARs movements. Two CT images were matched by pelvic structures. In both imaging results, we defined the tandem by the tip and the base as the marker point, and evaluated applicator shift, including X, Y and Z. Based on the repeated CT imaging, oncologist contoured the target volume and OARs again. We combined the treatment plan with the repeated CT imaging and evaluated the change range for the doses of CTVhr D90, D2cc of OARs. Results: The average applicator shift was -0.16 mm to 0.10 mm for X, 1.49 mm to 2.14 mm for Y, and 1.9 mm to 2.3 mm for Z. The change of average physical doses and EQD2 values in Gy${\alpha}/{\beta}$ range for CTVhr D90 decreased by 2.55 % and 3.5 %, bladder D2cc decreased by 5.94 % and 8.77 %, rectum D2cc decreased by 2.94 % and 4 %, sigmoid colon D2cc decreased by 3.38 % and 3.72 %, and small intestines D2cc increased by 3.72 % and 10.94 %. Conclusions: Applicator shifts and DVH parameter changes induced the total dose inaccurately and could not be ignored. The doses of target volume and OARs varied inevitably.

Waveguide Applicator System for Head and Neck Hyperthermia Treatment

  • Fiser, Ondrej;Merunka, Ilja;Vrba, Jan
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1744-1753
    • /
    • 2016
  • The main purpose of this article is a complex hyperthermia applicator system design for treatment of head and neck region. The applicator system is composed of four waveguides with a stripline horn aperture and circular water bolus. The specific absorption rate (SAR) and temperature distribution from this applicator in various numerical phantom models was investigated. For used targets, the treatment planning based on the optimization process made through the SEMCAD X software is added to show the steering possibilities of SAR and thereby temperature distribution. Using treatment planning software, we proved that the SAR and temperature distribution can be effectively controlled (by amplitude and phase changing) improving the SAR and temperature target coverage approximately by 20 %. For the proposed applicator system analysis and quantitative evaluation of two parameters 25 % iso-SAR and $41^{\circ}C$ iso-temperature contours in the treatment area with the respect to sensitive structures in treatment area were defined. To verify our simulation results, the real measurement of reflectivity coefficient as well as the temperature distribution in a homogenous phantom were performed.

Intracavitary Ultrasound Hyperthermia Applicators for Gynecological Cancer

  • Lee, Rena J. .;Suh, Hyun-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.53-53
    • /
    • 2003
  • For evaluating the feasibility of treating recurrent lesions in the vaginal cuff and cervix by hyperthermia, ultrasound applicators were designed, constructed, and characterized. For the treatment A half-cylindrical transducer Cd=1cm, length=lcm) and cylindrical transducer (d=2.5cm, length= 1.5cm) were used to construct ovoid type and cylindrical applicators. For the ovoid type applicator, each element was operated at 1.5MHz and characterized by measuring transducer efficiency and acoustic power distribution. Thermocouple probes were used to measure the temperature rise in phantom. The element sizes used in this study were selected to be comparable for high dose rate brachytherapy colpostat applicator. Each element was powered separately to achieve a desired temperature pattern in a target. The acoustic output power as a function of applied electric power of the element 1 and 2 was linear over this 1 to 40 W range and efficiencies were 32.2${\pm}$3.4% and 46.2${\pm}$0.8%, respectively. The temperature measurements in phantom showed that 6$^{\circ}C$ temperature rise was achieved at 2 cm from the applicator surface. As a conclusion, the ability of the ultrasound colpostat applicator to be used for hyperthermia was demonstrated by measuring acoustic output power, ultrasound field distribution, and temperature rise in phantom. Based on the characteristics of this applicator, it has the potential to be useful for inducing hyperthermnia to the vaginal cuff in clinic.

  • PDF

Development of a Variable Rate Granule Applicator for Environment-Friendly Precision Agriculture (III) - Analysis of Pneumatic Conveying System and Improvement of Fertilizer Application Uniformity - (친환경 정밀농업을 위한 입제 변량살포기 개발 (III) -공기이송 시스템 분석과 입제 살포균등도 향상-)

  • Kim, Y.J.;Kim, H.J.;Jang, T.S.;Rhee, J.Y.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.6 s.119
    • /
    • pp.482-488
    • /
    • 2006
  • Application of precision farming technology to rice cultivation could be an effective measure for rice quality improvement and environment-friendly agriculture. This study was conducted to develope a variable rate pneumatic granule applicator. Previous study reported that application uniformity of the prototype machine (C.V. = 23.3%) was not satisfactory. To improve the uniformity, increase of blow-head number from 12 to 16 was suggested. Analysis of the pneumatic conveying system showed that increase of number of blow-head was possible. Three-way variance analysis of the modified applicator showed that inserting length should be changed according to granule metering rate. The range of metering rate from 27.3 to 417.9 g/s were divided into 4 levels and 4 sets of inserting lengths were determined to ensure CV values less than 15%. The revised applicator showed satisfactory C.V. values of 9.4 to 14.6% in the metering rate. Granule conveying pattern was observed using a high speed camera and judged as the homogeneous flow pattern.

Design and Thermal Distribution of Microwave Spiral Antenna (마이크로파 나선형 안테나의 제작과 온열분포)

  • Lee, Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.8 no.2
    • /
    • pp.155-162
    • /
    • 1990
  • Spiral microwave antennas have been developed and measured the thermal distribution in agar phantom. The design has been configured in three types, 3 cm $\phi$ applicator with 24.5 cm length (A type),4 cm $\phi$ with 12.2 cm (B type) and 6 cm $\phi$ with 24.5 cm length (C type). The relative specific absorption rate (SAR) measured in phantom have been used to estimate the depth and profile of effective heating. The applicator of copper antenna with 4 cm $\phi$ diameter and 12.2 cm length (B type) has the most homogeneous (FWHM=3.5 cm) and heating into deep site ($D_{eff}=4\;cm$).

  • PDF

Design of A Pneumatic Granular Applicator For Paddy Field

  • Chung, Chang-Joo;Chung, Sun-Ok;Cho, Seong-In;Chang, Young-Chang;Park, Yeong-Soo
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.519-527
    • /
    • 1996
  • Most operation related to the application granular agrochemicals in korea are manual and labour consuming. As a multipurpose granular applicator, a pneumatic granular applicator that can be attached to conventional ride -on machines for paddy field was designed in this study. Experiments and simulations were carried out for determine in the design factors with one fertilizer (DongBu 21-17-17) and one pesticide (SamKong Ivi). The maximum terminal velocity of granular chemicals was estimated as 14.2m/s. A better distribution pattern was obtained at the diffuser having only deflectors without dividing guides. The diffuser spacing 1.0m for the fertilizer and the diffuser spacing 0.8m for the pesticide at the boom height over 0.80m were acceptable for the uniform distribution. In the case that the forward speed of ride-on machines was 0.7m/s, the groove opening and the roller speed of the selected metering device were13mm -15mm at 2 rps for the fertilizer, and 9 mm-11mm at 0.25rps or the pesticide. This study suggested a method of developing a pneumatic applicator for granular agrochemicals.

  • PDF

Circularly Rotated Array for Dual Polarized Applicator in Superficial Hyperthermia System

  • Kim, Ki Joon;Choi, Woo Cheol;Yoon, Young Joong
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.1
    • /
    • pp.20-25
    • /
    • 2015
  • A circularly rotated array for a dual polarized applicator in a superficial hyperthermia system is proposed. The applicator has a wider effective treatment area due to the $180^{\circ}$ phase shift. The dual polarized circularly rotated array (DPCRA) suppresses overheating at the center of the array and helps evenly distribute the heat. This array provides a more effective treatment area than a lattice array when a $2{\times}2$ dual polarized array is fitted to the treatment area. The treatment area is 71.5% of the aperture, whereas the effective treatment areas of the $2{\times}2$ dual polarized lattice array (DPLA) and the single polarized array (SPA) are 57.2% and 38.6% of the same aperture, respectively. The measurement matches the simulation results without blood circulation effects. In a $2{\times}2$ array applicator, the proposed DPCRA has more heat uniformity than the DLA and the SPA.

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy (재발한 Vulvar 종양의 근접치료 시 Modified Mupit Applicator의 적용)

  • Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • Purpose: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Materials and Methods: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator, an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was peformed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS(192-lr HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3,000 cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Results: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1 cGy, 57.1 cGy, 103.8 cGy, 162.7 cGy, 165.7 cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1 cGy, 57.1 cGy. Conclusion: Patients with locally recurrent tumor in uterine cervix cancel treated with modified MUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry provided by the template and cylinders. and improved dose distributions in irregular tumor volume without rectal complication.

  • PDF

An Analysis of Flows of Coating Materials in an Optical Fiber Coating Applicator (광섬유 피복 장치 내의 피복재 유동 해석)

  • Park Tae Sang;Suh Jung-Soo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.11a
    • /
    • pp.102-107
    • /
    • 1998
  • Axisymmetric flows in an optical fiber coating applicator were computed by using structured finite volume solver FLUENT. The numerical computations were performed for various draw speeds from 900m/min to 1,200m/min. The physical phenomena in the coating applicator is the main topic of this paper. The results of the simulations covering streamline, pressure, temperature, and fluid-fluid interface are shown in this paper.

  • PDF

A Theoretical Analysis of Thermic Endfire Interstitial Applicator

  • Park, Jong-Kweon;Eom, Hyo-Joon
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.1
    • /
    • pp.60-62
    • /
    • 2001
  • A novel approach for modeling the thermic endfire interstitial applicator is presented. A hypothetical semi-infinite circular cylinder is added in the endfire direction in order to facilitate the theoretical modeling approach. The Fourier transform and mode-matching technique is utilized to obtain a solution in fast-convergent series Numerical computations for the input impedance are performed to check the Validity of the theoretical model.

  • PDF