• Title/Summary/Keyword: apparatus development

Search Result 701, Processing Time 0.02 seconds

Development of the Program Road lighting Road Surface Property Measuring Apparatus (도로조명용 프로그램과 노면특성 장치의 개발)

  • ;金紀勳
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.133-133
    • /
    • 1999
  • Average illuminance and luminance can be calculated by graphical methods to a certain extent but to calculate for a wide place a suitable software is needed. Softwares suitable for this purpose have been already developed in foreign nations, but the appropriate softwares for domestic use have not been developed. Therefore a program is developed which is executable in Hangul Windows. The softwares LAPRoad, is developed to calculate luminance and illuminance distribution of road surface, as well as average luminance and illuminance, overall uniformity, longitudinal uniformity, threshold increment veilling luminance and glare. And an apparatus that measures road surface reflection properties is developed. Because the road surface reflection properties is very important in luminance calculation, then concrete road surface reflection properties were measured.

ON Salinity of Comduit Discharge from Selective Withdrawal Apparatus (선정된 배수관의 유출수 감분농도에 관한 연구)

  • 서영재;김진규
    • Water for future
    • /
    • v.25 no.2
    • /
    • pp.99-110
    • /
    • 1992
  • A problem of outlet salinity from a stratified fluid with a well developed interface thickness consisting of an upper and lower layer differing slightly in density is considered. Three kinds of apparatus were used for the experimental test and salinity differences between inlet layer and outlet discharge were estimated by the functional relationship using the dimensionless values. For the critical incipient condition of withdrawal of upper layer, Densimetric Froude number is correlated by the inlet diameter and depth ratio in the tank.

  • PDF

A study on simplified Textile testing apparatus for teaching high school students (중고등학교 피복재료 학습효과를 높이기 위한 시험장치 개발에 관한 연구)

  • 장경연
    • Journal of the Korean Home Economics Association
    • /
    • v.26 no.2
    • /
    • pp.69-79
    • /
    • 1988
  • This study was to increase the experimental learning effect of textile materials in middle and high school. To this study, three kinds of simply devised apparatus were used for warmth retaining test, air permeability test and static electricity test. Two classes were chosen in a girls' high school comparing learning effect and classified the theoretical learning group and the experimental learning group. In the experimental group, a teaching plan to teach the properties of textile materials was made to use these apparatuses. The results were. 1. In the interest on the unit either the theoretical learning group or the experimental learning group were not different significantly. 2. In the items facilitation of motivation, unsatisfied desires and prevention of failure, effect of transfer and development of inquiry power, both groups were significant. 3. For the purpose of comparing the learning effect, two groups were examined for determining the level of understanding after teaching properties of textile materials. The mean value of the experimental learning group was higher than that of the theoretical learning group. The experimental learning group had more higher markers(over the point of 90) than the theoretical learning group.

  • PDF

A Study on the Characteristics of the Combined Generation System by Solar and Wind Energy with Power Storage Apparatus for the Geographical Features

  • Lim, Jung-Yeol;Kang, Byeong-bok;Cha, In-Su
    • Journal of Power Electronics
    • /
    • v.2 no.1
    • /
    • pp.11-18
    • /
    • 2002
  • The development of the solar and the wind energy is necessary since the future alternative energies that have no pollution and no limitation are restricted. Currently MW Class power generation system has been developed, but it still has a few faults with the weather condition. In order to solve these existing problems, combined generation system of photovoltaic and wind power was suggested. It combines wind power energy and solar energy to have the supporting effect from each other. However, since even combined generation system cannot always generate stable output with everchanging weather condition, power storage apparatus that uses elastic energy of spiral spring to combined generation system was also added for the present study.

Development of combined generation systems that power storage apparatus is applied (동력저장장치가 적용된 복합발전시스템의 개발)

  • Lee, Jeong-Il;Seo, Jang-Soo;Kang, Byung-Bog;Cha, In-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.4
    • /
    • pp.169-174
    • /
    • 2002
  • The developments of the solar and the wind power energy are neccessary since the future alternative energies that have no pollution and no limitation are restricted. Currently power generation system of existing problems, combined generation system of photovoltaic(400W) and wind power generation system(400W) was suggested. It combines wind power and solar energy to have the supporting effect from each other. However, weather condition, power compensation device that uses elastic energy of spiral spring to combined generation system was also added for the present study. In an experiment, when output of system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator.

A Study on the step response characteristics in shielded resistor divider for full lightning impulse voltage (전파 뇌충격전압 측정용 쉴드저항분압기의 직각파 특성에 관한 연구)

  • 김익수;이형호;조정수;박정후
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.283-288
    • /
    • 1996
  • This paper presents the development technology of standard shielded resistor divider for full lightning impulse voltage. The ability of large-capacity power apparatus to withstand lighting stroke is usually evaluated by means of full lightning impulse voltage. Lightning impulse voltage test has been essential to evaluate the insulation performance of electrical power apparatus. Recently international standard (IEC 60) on high voltage measurement techniques is being revised and requests a formal traceability of high voltage measurements. Therefore, general interest for this area has grown considerably during last years, and several international intercomparisons have already completed worldwide, i.e. Europe, Japan, America etc., In this viewpoint, we have also investigated the step response of the standard shielded resistor divider, which satisfies the IEC recommendation.

  • PDF

DATA LOGGER APPARATUS FOR MEASUREMENT STRAY CURRENT OF SUBWAY AND POWER LINE (지하철과 전력선의 누설전류 측정을 위한 저장형 데이터 계측장치)

  • Bae, Jeong-Hyo;Ha, Yun-Cheol;Ha, Tae-Hyeon;Lee, Hyeon-Gu;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.731-734
    • /
    • 2003
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so. In this paper, results of development about data logger apparatus for measurement stray current of subway and power line are presented.

  • PDF

A study on the dry development of Electron beam negative resist (전자빔 네가티브 레지스트의 건식현상에 관한 연구)

  • Park, J.K.;Park, S.G.;Cho, S.U.;Woo, H.W.;Kim, Y.B.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.278-280
    • /
    • 1994
  • The purpose of this paper is to describe an application of plasma polymerized thin film as an electron beam resist. Plasma polymerized thin film was prepared using an interelectrod inductively coupled gas-flow-type reactor. Styrene was chosen as the monomer to be used. This thin films were also delineated by the electron-beam apparatus and the pattern in the resist was developed with RIE and plasma polymerized apparatus. The effect of charge of pressure on growth rate and etching rate of the thin films were studied. The molecular structure of thin film was investigated by FT-IR and then was discussed in relation to its quality as a resist.

  • PDF

Development of Type 4 Composite Pressure Vessel by using PET Liner for Self-contained Breathing Apparatus (PET 라이너를 적용한 공기호흡기용 타입 복합재료 4 압력용기 개발)

  • Cho, Sung-Min;Lee, Seung-kuk;Cho, Min-sik;Lyu, Sung-ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.164-169
    • /
    • 2018
  • In this study, we solved the human hazard problem of aluminum liner by applying plastic PET liner which is widely used as a material for food and beverage containers in the market. In order to reinforce dome area by using low strength / high elongation plastic liner, The aluminum boss was covered on the plastic liner surface. In order to predict the performance of the developed product, the structural analysis was carried out by applying the three - dimensional laminated solid element, and the soundness of the product was verified through the prototype performance test.

Manufacture of Apparatus for Coolant Mix Performance Test (냉각제 혼합성능 시험용 장치의 제작)

  • Ku, Hyoun-Kon;Bae, Young-Gwan;Kim, Jin-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.2
    • /
    • pp.73-78
    • /
    • 2022
  • The test apparatus that can be protected from the high-temperature combustion flame and coolant injection was successfully manufactured. In this study, the coolant-injection module had a controllable consistent pressure, and the entire combustion module was protected using a nonflammable composite liner. Every flange was designed in accordance with the DIN standard, and the entire body of the module was designed in accordance with the EN 13445 code. Additionally, the hydraulic pressure test was performed in accordance with the 2014/68/EU directive and EN 13445 standard. Finally, after manufacturing, performance tests (such as pressure tests) were conducted to verify the reliability and safety.