• Title/Summary/Keyword: aperture ratio

Search Result 213, Processing Time 0.029 seconds

Transflective Liquid Crystal Display with High Aperture Ratio using Electrophoresis Particles

  • Cheong, Seung-Hwan;Bae, Kwang-Soo;Yu, Chang-Jae;Kim, Jae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.166-168
    • /
    • 2009
  • We proposed a transflective liquid crystal display (LCD) with high aperture ratio using an electrophoretic particle layer (EPL). The transflective LCD consisted of the stacked LC layer and EPL which was acted as a switchable mirror under in-plane electrode structure. Without separation of reflective part and transmissive part in one pixel, a modeselectable display device can be obtained.

  • PDF

Analysis of the Radiation Pattern of a Microstrip Array Antenna on a Non-Planar Surface by using FOURIER TRANSFORM (FOURIER TRANSFORM을 이용한 비평면형 마이크로스트립 어레이 안테나의 복사패턴 해석)

  • 고광태;구연건
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.9
    • /
    • pp.785-795
    • /
    • 1990
  • For the far field radiation pattern of a microstrip array antenna which is conformed to a cylindrical surface and forms an arc array, an approximate analysis method using FOURIER TRANSFORM is presented. In this method, the conformal array antenna is projected on the effective aperture plane and assumed to be an aperiodic array with nonlinear phase tilt. The effective aperture plane includes four end-points of each arc on the cylindrical surface. When the effective aperture ratio which is normalized to the planar type is from 1.0 to 0.9, it is confirmed that this approximate method is valid. To the array on the effective aperture plane, it is assumed that the phase tilt is due to the distance between aperture plne and curvature surface. Specially, when the radius of arc is more than 5 times to its length, the FOURIER TRANSFORM METHOD could be used with only varying scale factors. The results of calculating by approximate method are good agreement with the results of COORDINATE TRANSFORM METHOD and experimentally measured value in the range of -40dB. And, the difference of half power angle is less than 5 degrees when the effective aperture ratio moer than 0.9.

  • PDF

A Study on Design Parameters for Ready-made Ear Shell of Hearing Aids (보청기용 범용 이어쉘을 위한 설계 파라미터에 관한 연구)

  • Urtnasan, Erdenebayar;Jeon, Yu-Yong;Park, Gyu-Seok;Song, Young-Rok;Lee, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1055-1061
    • /
    • 2011
  • In this study, main parameters: aperture, first bend and second bend which express a structure of ear canal are extracted in order to modeling and manufacture the ready-made ear shells of hearing aids. The proposed parameter extraction method consists of 2 important algorithms, aperture detection and feature detection. In the aperture detection algorithm, aperture of 3-D scanned virtual ear impression and parameters relating to ear shell of hearing aid are determined. The feature detection algorithm detects first bend, second bend, and related parameters. Through these two algorithms, parameters for aperture, first bend, and second bend are extracted to model the ready-made ear shell of hearing aid. The values of these extracted parameters from 36 people's right ear impression are analyzed and measured statistically. As a result of the analysis, it has been found that it is possible to classify ready-made ear shell parameters by age and size. The ready-made ear shell parameters are classified 3-size for 20 years old and 2-size for 60 years olde. Using 3D rhino program, virtual ready-made ear shell is reconstructed by parameters of every type, and simulated to model it. A final product was produced by transferring simulation result with rapid prototyping system. The modeled ready-made ear shell is evaluated with the objective and subjective method. Objective method is the comparison volume ratio and overlapped volume ratio of ear impression from randomly chosen 18 people and ready-made ear shell. And subjective method is that the final product of ready-made ear shell is used by users and the satisfaction number drawn from well fitting and comfortable testing was evaluated. In the result of the evaluation, it has been found that volume ration is 70%, big and middle size ready-made ear shell products are possible, and the satisfaction number is high.

2.22-inch qVGA a-Si TFT-LCD Using a 2.5 um Fine-Patterning Technology by Wet Etch Process

  • Lee, Jae-Bok;Park, Sun;Heo, Seong-Kweon;You, Chun-Ki;Min, Hoon-Kee;Kim, Chi-Woo
    • Journal of Information Display
    • /
    • v.7 no.3
    • /
    • pp.1-4
    • /
    • 2006
  • 2.22-inch qVGA $(240{\times}320)$ amorphous silicon thin film transistor liquid active matrix crystal display (a-Si TFT-AMLCD) panel has been successfully demonstrated employing a 2.5 um fine-patterning technology by a wet etch process. Higher resolution 2.22-inch qVGA LCD panel with an aperture ratio of 58% can be fabricated as the 2.5 um fine pattern formation technique is integrated with high thermal photo-resist (PR) development. In addition, a novel concept of unique a-Si TFT process architecture, which is advantageous in terms of reliability, was proposed in the fabrication of 2.22-inch qVGA LCD panel. Overall results show that the 2.5 um fine-patterning is a considerably significant technology to obtain higher aperture ratio for higher resolution a-Si TFT-LCD panel realization.

Coded Aperture Gamma Camera for Thyroid Imaging: Monte Carlo Simulation (갑상선 영상 획득을 위한 부호화 구경 감마카메라: 몬테칼로 시뮬레이션 연구)

  • Beak, Cheol-Ha;Lee, Seung-Jae;Chung, Yong-Hyun
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.247-255
    • /
    • 2008
  • A coded aperture camera has been developed to improve the signal-to-noise ratio (SNR) while keeping the spatial resolution of a pinhole gamma camera. The purpose of this study was to optimize a coded aperture camera and to evaluate its possibility for thyroid imaging by Monte Carlo simulation. A clinical gamma camera, a pinhole collimator with 1.0 mm hole diameter, and a $79{\times}79$ modified uniformly redundant array (MURA) mask were designed using GATE (Geant4 Application for Tomographic Emission). The penetration ratio, spatial resolution, integral uniformity and signal-to-noise ratio (SNR) were simulated and evaluated as a function of the mask thickness. The spatial resolution of the coded aperture camera was consistent with the various mask thickness, SNR showed a maximum value at 1.2 mm mask thickness and integral uniformity was improved by increasing mask thickness. Compare to the pinhole gamma camera, the coded aperture camera showed improved SNR by a factor of 30 while keeping almost the same spatial resolution. In this simulation study, the results indicated that high spatial resolution and ultra-high SNR of the thyroid imaging are feasible using a coded aperture camera.

  • PDF

Design and Development of a Single-photon Laser and Infrared Common Aperture Optical System

  • Wu, Hongbo;Zhang, Xin;Tan, Shuanglong;Liu, Mingxin;Wang, Lingjie;Yan, Lei;Liu, Yang;Shi, Guangwei
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.171-182
    • /
    • 2022
  • A single-photon laser and mid-wave infrared (MWIR) common aperture optical system was designed and developed to detect and range a long-distance civil aviation aircraft. The secondary mirror of the Ritchey-Chretien (R-C) optical system was chosen as a dichroic lens to realize the design of a common aperture system for the laser and MWIR. Point spread function (PSF) ellipticity was introduced to evaluate the coupling efficiency of the laser receiving system. A small aperture stop and narrow filter were set in the secondary image plane and an afocal light path of the laser system, respectively, and the stray light suppression ability of the small aperture stop was verified by modeling and simulation. With high-precision manufacturing technology by single point diamond turning (SPDT) and a high-efficiency dichroic coating, the laser/MWIR common aperture optical system with a 𝜑300 mm aluminum alloy mirror obtained images of buildings at a distance of 5 km with great quality. A civil aviation aircraft detection experiment was conducted. The results show that the common aperture system could detect and track long-distance civil aviation aircraft effectively, and the coverage was more than 450 km (signal-to-noise ratio = 6.3). It satisfied the application requirements for earlier warning and ranging of long-range targets in the area of aviation, aerospace and ground detection systems.

A study on the image formation system variable and performance analysis for optimum design of high resolution SAR (고해상도 SAR 최적 설계를 위한 영상형성 시스템 변수 및 성능분석에 관한 연구)

  • Kwak, Jun-Young;Jeong, Dae-Gwon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.1
    • /
    • pp.49-60
    • /
    • 2012
  • Synthetic aperture radar (SAR) has been employed in various fields due to its capability to generate high resolution images regardless of weather and visibility. This paper presents a performance analysis on the image formation of high resolution SAR according to various slant range distance and synthetic aperture lengths using a range migration algorithm simulator. Although the visual performance on the SAR image is more accurate, a numeric analysis resulted in a comparable measurement. More specifically, raw data were generated for an ideal point target upon imaging geometries and design parameters such as slant range distance and synthetic aperture lengths. Finally, spatial resolution, peak to sidelobe ratio and integrated sidelobe ratio are drawn to provide SAR capabilities in the initial concept design, final in-flight calibration and validation stages.

Development of a Coded-aperture Gamma Camera for Monitoring of Radioactive Materials (방사성 물질 감시를 위한 부호화 구경 감마카메라 개발)

  • Cho, Gye-Seong;Shin, Hyung-Joo;Chi, Yong-Ki;Yoon, Jeong-Hyoun
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.257-261
    • /
    • 2004
  • A coded-aperture gamma camera was developed to increase the sensitivity of a pin hole camera made with a pixellated CsI(Tl) scintillator and a position-sensitive photomultiplier tube. The modified round-hole uniformly redundant array of pixel size $13{\times}11$ was chosen as a coded mask considering the detector spatial resolution. The performance of the coded-aperture camera was compared with the pin hole camera using various forms of Tc-99m source to see the improvement of signal-to-noise ratio or the improvement of the sensitivity. The image quality is much improved despite of a slight degradation of the spatial resolution. Though the camera and the test were made for low energy case, but the concept of the coded-aperture gamma camera could be effectively used for the radioactive environmental monitoring and other applications.

Electromagnetic Scattering by a Two-Dimensional Periodic Array of Small Resonant Apertures (소형 공진 개구의 2차원 주기적 배열에 의한 전자파 산란)

  • Ko, Ji-Hwan;Lee, Jong-Ig;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.320-326
    • /
    • 2011
  • Comparative study on the total transmission(zero reflection) has been done between two FSS structures which are coqmposed of the resonant aperture and the nonresonant aperture. It has been found that, the FSS of the resonant aperture has much larger ratio ${\lambda}$/T of wavelength ${\lambda}$ to array periodicity T than that of the FSS of the nonresonant aperture for the total transmission(or zero reflection). Also the operating frequency can be made to be significantly reduced by using such a resonant structure. This physical situation is thought to be similar to that of EOT(Extraordinary Optical Transmission) phenomenon, in optics area.

Advanced Pixel Structure for Higher Aperture Ratio in TFT-LCD

  • Kim, Jong-Hoon;Noh, Sang-Yong;Kang, Shin-Tack;Lee, Jong-Hwan;Choi, Kwang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.17-19
    • /
    • 2008
  • An advanced TFT-LCD structure was proposed to increase aperture ratio (AR). In this structure, metal layers formed below the data lines are used as light-blocking layers, achieving higher AR ratio than that of a conventional structure. Since average misalignment between the metal light-blocking layers and pixel electrodes is smaller than that of black matrixes on color filter glass, substantially less light-blocking areas are needed to achieve misalignment margin. The AR of the LCD panel fabricated by using proposed structure was enhanced by 18.7 % over that of the conventionally structured panel.

  • PDF