• Title/Summary/Keyword: aperture opening size

Search Result 7, Processing Time 0.024 seconds

A Subjective Study on the Reverberation Characteristics of Coupled Spaces (음향적으로 결합된 공간의 주관적 잔향감에 관한 연구)

  • Jeong, Dae-Up;Choi, Young-Ji
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.3
    • /
    • pp.65-73
    • /
    • 2008
  • The present work deals with subjective assessments to propose the objective parameter related to the subjective attribute of reverberation in the coupled room varied the aperture opening size. A 1/10 scale model was built and used for the measurements and subjective assessments. For the subjective tests, binaural impulse responses(BIRs) were measured using a dummy head and the measured BIRs were convolved with anechoic recorded music for the presentation over the headphones. The results showed that the perceived reverberation was the largest in the aperture opening size 12.5%(1.97% of mail) room surface area)and decreased with increasing the aperture opening size over 25% (3.94% of main room surface area) in the main room coupled with the secondary reverberant room. In the main room coupled with the secondary absorptive room, there was no changes in the perceived reverberation up to the aperture opening size 6.25%(0.99% of main room surface area) and it gradually decreased with increasing the aperture opening site over 12.5%. The objective parameter, T30/T15, showed a very low correlation with the perceived reverberation in the coupled room varied the aperture opening size but showed a high correlation with a new objective parameter, T30/Tbp, proposed by the authors. Because the late part decay energy more rapidly increases with increasing the aperture opening site than the early and middle part decay energy, the LDT/EDT or T3/T1 is a better quantifier to measure double slopes in the coupled room than the T30/T15.

  • PDF

A Study on the Reverberation Characteristics of Coupled Spaces (음향적으로 결합된 공간의 잔향특성변화에 관한 연구)

  • Jeong, Dae-Up;Kim, Ji-Young;Choi, Young-Ji
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.3
    • /
    • pp.53-63
    • /
    • 2008
  • In this study, the reverberation characteristics of coupled spaces were investigated using a scale model. Two rooms were connected through an acoustically transparent opening known as an aperture. The acoustic characteristics of the coupled room by varying three parameters, the aperture opening size, the absorption ratio between the two rooms and the locations of the secondary room, were measured and analysed. The results indicated that a reverberant secondary room, produced large variations of the acoustics in the main room and an absorptive secondary room was effective to provide systematic control of the acoustics in the main room. The reverberant secondary room should be located at the rear of the stage and the aperture opening ratio over 6.25% produced large variations of the acoustics in the main room. However, the aperture opening ratio over 25% had no effect on variations of the acoustics in the main room. The absorptive secondary room should be located at the rear of the audience areas and the aperture opening ratio over 3.13% produced large variations of the acoustics in the main room.

  • PDF

Accurate quantitative assessment of grouting efficiency in fractured rocks by evaluating the aperture sizes of fractures (절리암반내 그라우팅 성과에 대한 정량적인 판단기법 개발)

  • 김중열;김유성;김형수;백건하;김기석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.695-702
    • /
    • 2002
  • Groundwater flow is primarily influenced by the presence of fractures, functioning as conduits. To block the flow, grouting operation is commonly used. Thereby the fractures are then expected to be sealed, which will add to enhance the shear strength in rock. This far, regarding the assessment of grouting efficiency, however, there's been a considerable uncertainty That is, several geophysical methods of high resolution such as tomography, S-wave logging have produced a significant amount of measurable response caused by grouting, but they can inevitably be used only for the qualitative assessment. Thus, this paper deals with an accurate quantitative assessment about the grouting result. In this, a new strategy is introduced, based mainly on evaluating the opening of fractures. For fracture-opening investigation purposes, borehole Televiewer has already proven to be an excellent logging technique that produces both amplitude image and traveltime image. As well known, the traveltime image can be converted to a high precision 3D caliper log with max. 288 arms, which allows to observe the opening of fractures. To evaluate the fracture opening from the traveltime image, an algorithm of practical use was developed, in which image correction due to the borehole deviation, feature discrimination of wall roughness from fractures, automatic evaluation procedure etc. were considered. Field examples are shown to confirm the efficiency of the suggested method.

  • PDF

Temperature Control of Greenhouse Using Ventilation Window Adjustments by a Fuzzy Algorithm (퍼지제어에 의한 자연환기온실의 온도제어)

  • 정태상;민영봉;문경규
    • Journal of Bio-Environment Control
    • /
    • v.10 no.1
    • /
    • pp.42-49
    • /
    • 2001
  • This study was carried out to develop a fuzzy control technique of ventilation window for controlling a temperature in a greenhouse. To reduce the fuzzy variables, the inside air temperature shop was taken as one of fuzzy variables, because the inside air temperature variation of a greenhouse by ventilation at the same window aperture is affected by difference between inside and outside air temperature, outside wind speed and the wind direction. Therefore, the antecedent variables for fuzzy algorithm were used the control error and its slop, which was same value as the inside air temperature slop during the control period, and the conclusion variable was used the window aperture opening rate. Through the basic and applicative control experiment with the control period of 3 minutes the optimum ranges of fuzzy variables were decided. The control error and its slop were taken as 3 and 1.5 times compared with target error in steady state, and the window opening rate were taken as 30% of full size of the window aperture. To evaluate the developed fuzzy algorithm in which the optimized 19 rules of fuzzy production were used, the performances of fuzzy control and PID control were compared. The temperature control errors by the fuzzy control and PID control were lower than 1.3$^{\circ}C$ and 2.2$^{\circ}C$ respectively. The accumulated operating size of the window, the number of operating and the number of inverse operating for the fuzzy control were 0.4 times, 0.5 times and 0.3 times of those compared with the PID control. Therefore, the fuzzy control can operating the window more smooth and reduce the operating energy by 1/2 times of PID control.

  • PDF

The Relation of Fracture Properties to Hydraulic Conductivity in Volcanic Rocks of the Northern Yosu Area (여수 북부지역 화산암의 단열특성과 수리전도도와의 관계)

  • 조성일;송무영;김경수;이은용
    • The Journal of Engineering Geology
    • /
    • v.9 no.3
    • /
    • pp.227-241
    • /
    • 1999
  • Groundwater flow in a fractured rock mass is related to the geometric characteristics of the fracture system. The objective of this study aims to analyze the probabilistic density function of fracture properties md their relations to the hydraulic conductivity in volcanic rocks of the northern Yosu area. Fracture characteristics were investigated by core logging and acoustic televiewer logging in four boreholes and the hydraulic conductivity was obtained from the constant pressure injection and fall-off tests. The 303 fractures were grouped into three sets by their orientation and three fracture types by the degree of opening in aperture. As a result of the study, the hydraulic conductivity in the test section intersected by open and semi-open fractures, conductive fractures, and set 1 fractures was very high, while closed fractures did rarely affect the hydraulic conductivity. It was recognized that the hydraulic conductivity in a fractured rock mass was preferentially affected by the aperture size of conductive fractures and fracture intersection frequency and size, secondly.

  • PDF

CORRECTION OF MICROSTOMIA BY BILATERAL COMMISSUROPLASTY USING "OVER AND OUT" BUCCAL MUCOSA FLAPS: REPORT OF A CASE (협점막 외전 피판을 이용한 양측성 구각성형술에 의한 소구증의 교정 1예)

  • Ryu, Sun-Youl;Kim, Hyun-Syeob;Park, Hong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.4
    • /
    • pp.380-385
    • /
    • 2008
  • Microstomia can be occurred as a result of direct injury to tissues such as chemical, thermal and electrical burns, and animal bites. It also may be secondary to contracture of burned perioral skin, or may result from scarring after reconstructive lip surgery. Narrowing of the oral aperture is not only disfiguring, but also limiting the oral access needed for introduction of food, insertion of dentures, oral hygiene, and dental treatment. Limited mouth opening may also interfere with mastication and speech. Few reports exist regarding correction of microstomia and reconstruction of the corners of the mouth. A 16-year-old girl with a bilateral cleft lip and palate presented with the limited mouth opening (approximately 20 mm), the esthetic problem due to the small lip, and the cleft lip-nasal deformity. The microstomia was corrected by bilateral commissuroplasty using "over and out" buccal mucosa flaps proposed by Converse. The intercommissure distance was increased from the preoperative 40 mm to the postoperative 60 mm. The one-year postoperative intercommissure distance was 54 mm, because the 6 mm relapse was occurred. The bilateral commissuroplasty using "over and out" buccal mucosa flap could increase the width and general size of the oral aperture and improve the lip appearance.

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF