• Title/Summary/Keyword: apartment energy consumption

Search Result 175, Processing Time 0.028 seconds

Analysis the case study of tower type apartment by opening types of building surface (탑상형 아파트의 외피개방유형에 따른 전기에너지 사용량 사례 분석)

  • Kim, Yu-Won;Lee, Hyun-Soo;Kim, Eun-Hye
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.111-115
    • /
    • 2011
  • The purpose of this study was the analysis of electric energy consumption with the case study of tower type apartment's opening of building surface. We analyze the relationship between tower type apartment's opening of building surface and using electric energy consumption. The results of this study are: 1) The highest energy consumption of electric energy was on August without any influence of opening types of building surface. 2) Also, the south-west sides consumption of August was 848 kWh on Type B(one side opening) and it was the highest usage. 3) A house if facing west used more electricity than facing east when its opening of building surface's datum level is facing south. However, the house of facing east used more power than west when its opening of building surface's datum level is facing north. 4) When opening of building surface is facing on north-west or north-east, the opening of building surface's side of west and east used more electric power than north-west or north-east sides.

  • PDF

Correlation Analysis between Energy Exclusive Dwelling Area and City Gas in Apartment Building - Focused on Cases in Ulsan, Korea-

  • Lee, Young-A;Park, Hung Suk;Son, Kiyoung
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.45-52
    • /
    • 2015
  • Purpose: Currently, since the energy consumption of apartment buildings is on the rise, it is necessary to reduce the total amount of the energy through the survey and analysis of energy consumption data. Although various studies for energy efficiency have been conducted, studies are more focused on the measurement of energy by using analysis tools. In addition, the studies are sufficient to analyze real data of the city gas in apartment buildings. Therefore, the objective of this study is to identify the property of annual and $1m^2$ city gas amount according to the exclusive dwelling area. Method: To achieve the objective, this study used the statistics such as descriptive, correlation, and analysis of variance (ANOVA) analysis. Result: As a result, there is positive relationship between the annual average of city gas and the exclusive dwelling area. However, in the case of $1m^2$ city gas amount, a negative relationship is mored. In the future, the findings of this study can be applied to develop the prediction model of the city gas consumption and implement it as basic data for energy efficiency of apartment buildings of future.

Energy Consumption Characteristics and Policy Directions According to Apartment Complex Type in Incheon Metropolitan City (초고층과 일반 아파트 단지의 에너지 소비 특성과 정책방향 연구 - 인천지역 아파트 단지의 전기 및 가스 사용량을 중심으로)

  • Rhee, Bum-Hun;Chang, Dong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.285-290
    • /
    • 2019
  • This study aims to compare the energy consumption characteristics of high-rise and general apartments and propose policy implications in Incheon City where high-rise apartments are planned. The method of analysis is to select the cases, to conduct field survey, drawing review, analysis of Electric Architectural administration Information System. The study derived the current status of energy consumption in high-rise and general apartment complexes located in the same region, Yeonsu-gu Incheon City, and performed comparative analysis on their characteristics. First, electrical energy in the high-rise apartment complexes was consumed excessively, by 1.63 to 2.5 times more than that of the general apartment complexes. Second, the gas energy usage in the high-rise apartment complexes was higher than that of the general complexes, by 1.09 to 1.2 times. Third, the energy consumption per unit area in the high-rises was also higher, by 1.042 to 1.3 times. As individual elements such as incomes, living standards, and life patterns of the residents affect energy consumption, the high-rise apartment complex consumed more energy per unit area than the general apartment complex did. However, this study did not consider the elements of energy expenditure and satisfaction level, which are the limitations of this research.

An investigation on the heating energy consumption and operating condition in apartment houses (공동주택의 에너지소비량 및 난방운전 실태에 관한 조사연구)

  • 신용태
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1994.05a
    • /
    • pp.45-50
    • /
    • 1994
  • The energy consumption in apartment houses is investigated according to the heating systems, that is, district, central, and individual heating systems. And, operating conditions of intermittent heating are surveryed and analysed in the central heating systems. As a result, each annual energy consumption of district, central and individual heating system is 143.56 Mcal/m2year, 216.78 Mcal/m2year and 150.68 Mcal/m2year, Also, the heating is generlly started at 04:00 and 17:00 of each day, and the heating system is operated for 2~3 hours per each time.

  • PDF

A Study on the Calculation of Thermal Consumption Unit of Apartment (공동주택의 열사용량원단위 산정에 관한 연구)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.388-393
    • /
    • 2014
  • Energy consumption unit in a building is classified according to uses of electricity, gas, and oil, and it has been studied steadily as a material for establishing policy standards for energy saving in buildings. Meanwhile, consumption unit in apartment house can be calculated differently according to its survey method and area standard. Therefore, with the necessity of reestablishing energy consumption unit, this study has researched thermal energy consumption, Supply dwelling area Exclusive dwelling area, completion year and housing type of 23,791 households of 31 complex in Daejeon. As a result, (1) there was about 20% difference between supply and exclusive dwelling areas. (2) On the basis of exclusive dwelling area, thermal energy consumption unit was calculated as $104.9kWh/m^2{\cdot}a$ in 2010, $104.6kWh/m^2{\cdot}a$ in 2011, and $107.7kWh/m^2{\cdot}a$ in 2012.

A study on the Estimation of Standard Heating City Gas Consumption of Apartment Housing (공동주택의 난방용 도시가스 표준사용량 산정에 관한 연구)

  • Shim, Yun-Hee;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.89-97
    • /
    • 2006
  • Our Housing culture continuously changes for the correspondence to social development and changes of economy, and be developing. A massive apartment complex continuously increased, and According to this in our country heating energy consumption of a residential building is continuously increasing at country me whom was limited in order to raise efficient residential land use and diffusion ratio of house. If confirm an element to be able to reduce use of a heating energy, and there is saving possibility to parts of energy saving, this study will present the standard amount used with bases to the gas amount used for heating and Field Test data about room temperature. Execute simulation with building balance (public area, a plain), the gas amount useds such as incense of a building, indoor setting temperature ($^{\circ}C$), a position of an apartment house etc. to affect the energy amount used of a valuation object building of a variable through Field Test and research on the actual condition. Calculate the standard amount used of city gas for winter season heating of a comparative analysis apartment house to data value getting the above results through Field Test and simulations with bases.

A Study on the Estimation of Heating Energy and CO2 Reduction depending on a Indoor Set Temperature and Clo value (착의량과 실내설정온도 관계에 따른 난방에너지 및 온실가스저감량 평가 연구)

  • Lee, Chul-Sung;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.49-54
    • /
    • 2010
  • Most energy using in building part is mainly consumed for heating and cooling to meet occupancy's comfort temperature. Generally, heating energy consumption show high value than cooling energy in Korea because of high temperature difference in winter season as compared with summer in apartment building. The efforts to develope mechanical performance have been studied to reduce energy consumption in building energy field until now. However, the energy consumption in building is impacted by not only system performance but also PMV particularly at temperature and Clo value. This means that energy consumption can be changed by occupancy's comfort setting temperature in apartment building. This study investigated the passibility of overheating in apartment building by occupant' slow Clo and its setting temperature from preceding research and then the heating energy consumption by setting temperature was calculated with ESP-r. The effects of heating energy and $CO_2$ reduction are also evaluated quantitatively with Clo value. The results showed that keeping ISO-7730 standards can reduce heating energy up to 21% in compared with option 2; also, wearing underclothes with ISO-7730 standard can considerably reduce heating energy consumption up to 50%. As compared with option 2, the reduction of $CO_2$ emission for option 3 showed 0.63TCO2 of kerosene, 0.49TCO2 of LNG and 1.09TCO2 of electricity. The option 4 can be reduced by 1.48TCO2 of kerosene, 1.16TCO2 of LNG and 2.57TCO2 of electricity respectively.

Comparative Evaluation of Electric Power and LNG Load according to Floor level of Tower-Type Apartments (탑상형 아파트의 층별 전기와 가스 부하량 비교평가)

  • Kim, Jun Hyun;Choi, Jin Ho;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.4
    • /
    • pp.465-475
    • /
    • 2011
  • It is known that energy consumption in bottom floor of typical Korean-style apartment is the highest. Previous studies for energy consumption in accordance with floor level appear to be very limited due to the dependence on single energy variable such as electric power or LNG separately, based on past flat type of apartment. Acknowledging these constraints, an empirical study for a tower type emerged recently as new style of apartment in South Korea was conducted to demonstrate how a comprehensive evaluation for both electric power and LNG consumption can be used to assist in monitoring the total energy consumption in terms of floor specific settings. It was possible to identify that energy consumption in bottom floor is lesser than that of top floor, to the contrary, fact known from previous study. Also electric power consumption in top floor was identified as 15% higher than that of floor in the least. It is anticipated that this integrated utilization of electric power and LNG data would present more scientific and objective evidence for the energy load among floor level of tower type apartment by overcoming serious constraints suffered from the past single variable investigation. Ultimately, the result in this paper could be used as a valuable reference to providing priority for energy saving activities in top floor such as cool roof or green roof.

Economic Feasibility Study for Providing Co-generation System in various Type of Apartment Complexes (아파트단지의 특성에 따른 열병합발전도입의 경제성 비교연구)

  • Gi, Woo-Bong;Kim, Gwang-Ho;Lim, Hee-Jin;Yoon, Kyung-Shick;Jang, Hyuk-Bong;Kim, Dong-Hwan
    • New & Renewable Energy
    • /
    • v.3 no.1 s.9
    • /
    • pp.27-37
    • /
    • 2007
  • This study is to analyse the feasibility for providing Co-generation plant in Apartment Complex for 4 typical Apartment Complexes located Seoul metropolitan area, The selected complexes are three midium-large size Apartment[nearby 35pyoug of floor area] and one complex of small size Apartment[below 25 pyoung of floor area] for comparison. The necessary data for the study were collected with visitation of each site. The study showed very positive result for the three medium-large size Apartment Complexes of which the average floor area is more than 25 pyoungs, while negative result for the Complex of which average floor area is less than 25 pyoungs. Other than floor size it was found that the electric consumption density also influence the economic feasibility. In study the unit fixed cost of the energy produced from Co-generation plant is one third of the unit variable cost[fuel cost] and it seems better to select high thermal efficiency machine for Co-generation plant even with some higher cost of the plant.

  • PDF

The Influence of Unit Plan Shapes to the Energy Efficiency of Collective Housing Simulated by ECO2 Software (ECO2 프로그램을 이용한 공동주택의 단위세대 평면 형태에 따른 에너지 효율 평가)

  • Kim, Chang-Sung
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.89-94
    • /
    • 2015
  • Purpose: Various policies to reduce the energy consumption have been carried out to save Earth environment against global warming and environmental pollution in many countries. Energy consumption of buildings in Korea has reached 24% of total energy consumption, and energy consumption of apartment has been continuously increasing. Therefore, Korea government has executed building energy efficiency rating certification system to control energy consumption of buildings. Method: This study was conducted to evaluate the energy performance of apartment unit plans according to the increasement of front width of unit plans, and tried to present the basic data to design more energy conscious unit plans for apartments. For the study, three shapes of unit plans -the 2Bay, 3Bay and 4bay unit- were selected for imput models. They were simulated using ECO2 software to assess building energy efficiency rating certification in Korea. Result: According to the results, in cases that balcony windows were not installed, the primary energy consumption of the 3Bay and 4Bay units were less than 2Bay unit, respectively, 0.1% and 2,5%. The primary energy consumption of the 3Bay and 4Bay units, in cases that balcony windows were installed, was less than 2Bay unit, respectively, 1.7% and 3.2%.