• Title/Summary/Keyword: aortic valvular deformity

Search Result 3, Processing Time 0.016 seconds

Congenital Aortic Valvular Insufficiency Caused by Abnormal Valvular Structures in a Labrador Retriever Dog (래브라도 리트리버종 개의 비정상 판막 구조에 의한 선천성 대동맥 판막 부전)

  • Moon, Hyeong-Sun;Lee, Seung-Gon;Lee, Sang-Eun;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.233-237
    • /
    • 2007
  • A 10-month-old intact male Labrador Retriever dog was referred with the primary complaint of exercise intolerance, especially after vigorous exercise. Physical examination revealed split S1 and grade III/VI diastolic regurgitant murmur at the left apex and base, respectively. ECG finding was normal sinus rhythm at rest, but supraventricular tachycardia with bundle branch blocks after exercise. Thoracic radiography revealed dilated ascending aorta with normal range of cardiac silhouette (VHS 10.2). Echocardiography revealed abnormal valvular structures just above the aortic valvular cusps causing aortic regurgitation with a reduction of left ventricular ejection fraction (LVEF). Based on those findings, the case was diagnosed as congenital aortic regurgitation caused by abnormal valvular structures. The dog was managed with diltiazem and exercise restriction. This is a rare case of aortic deformity in dogs.

A Study on the Manufacture of the Artificial Cardiac Tissue Valve (생체판의 제작 및 실험)

  • Kim, Hyoung-Mook;Song, Yo-Jun;Sohn, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.383-394
    • /
    • 1979
  • Treatment of valvular heart disease with valve replacement has been one of the most popular procedures in cardiac surgery recently. Although, first effort was directed toward the prosthetic valve, it soon became popular that bioprosthesis, the valvular xenograft, was prefered in the majority cases. Valvular xenograft has some superiority to the artificial prosthetic valve in some points of thromboembolism and hemolytic anemia, and it also has some inferiority of durability, immunologic reaction and resistance to Infection. Tremendous efforts were made to cover the inferiority with several methods of collection, preservation, and valve mounting of the porcine valve or pericardium of the calf, and also with surgical technique of the valvular xenograft replacement. Auther has collected 320 porcine aortic valves immediately after slaughter, and aortic cusps were coapted with cotton balls in the Valsalva sinuses to protect valve deformity after immersion in the Hanks' solution, and oxidation, cross-linking and reduction procedures were completed after the proposal of Carpentier in 1972. Well preserved aortic valves were suture mounted in the hand-made tissue valve frame of 19, 21, and 23 mm J.d., and also in the prosthetic vascular segment of 19 mm Ld. with 4-0 nylon sutures after careful trimming of the aortic valves. Completed valves were evaluated with bacteriologic culture, pressure tolerance test with tolerane gauge, valve durability test in the saline glycerine mixed solution with tolerance test machine in the speed of 300 rpm, and again with pathologic changes to obtain following results: 1. Bacteriologic culture of the valve tissue in five different preservation method for two weeks revealed excellent and satisfactory result in view of sterilization including 0.65% glutaraldehyde preservation group for one week bacteriologic culture except one tissue with Citobacter freundii in 75% ethanol preserved group. 2. Pressure tolerance test was done with an apparatus composed of V-connected manometer and pressure applicator. Tolerable limit of pressure was recorded when central leaking jet of saline was observed. Average pressure tolerated in each group was 168 mmHg in glutaraldehyde, 128 mmHg in formaldehyde, 92 mmHg in Dakin's solution, 48 mmHg in ethylene oxide gas, and 26 mmHg in ethanol preserved group in relation to the control group of Ringer's 90 mmHg respectively. 3. Prolonged durability test was performed in the group of frame mounted xenograft tissue valve with 300 up-and-down motion tolerance test machine/min. There were no specific valve deformity or wearing in both 19, 21, and 23 mm valves at the end of 3 months (actually 15 months), and another 3 months durability test revealed minimal valve leakage during pressure tolerance test due to contraction deformity of the non-coronary cusp at the end of 6 months (actually 30 months) in the largest 23 mm group. 4. Histopathologic observation was focussed in three view points, endothelial cell lining, collagen and elastic fiber destructions in each preservation methods and long durable valvular tolerance test group. Endothel ial cell lining and collagen fiber were well preserved in the glutaraldehyde and formaldehyde treated group with minimal destruction of elastic fiber. In long durable tolerance test group revealed complete destruction of the endothelial cell lining with minimal destruction of the collagen and elastic fiber in 3 month and 6 month group in relation to the time and severity. In conclusion, porcine xenograft treated after the proposal of Carpentier in 1972 and preserved in the glutaraldehyde solution was the best method of collection, preservation and valve mounting. Pressure tolerance and valve motion tolerance test, also, revealed most satisfactory results in the glutaraldehyde preserved group.

  • PDF

승모판막질환에 병발한 동맥색전증의 치험 1례

  • Hur, Y.;Kim, B.Y.;Lee, H.S.;Kim, J.E.;Lee, J.H.;Yu, H.S.
    • Journal of Chest Surgery
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 1980
  • We present one case of 26-year-old male having saddle block combined with mitral valvular disease [NYHA Class IV] with auricular fibrillation. The most common cause of emboli is atrial fibrillation. The clinical manifestations of saddle emboli are relatively slow due to development of collateral circulation and large size of lumen of the aorta. The 5month duration of saddle emboli in this case led to severe atrophic changes, coldness, peripheral cyanosis on the both lower extremities, and flexion deformity on the knee and ankle joint of the left lower extremity. We planned staged operation for the saddle block and for mitral stenoinsufficiency and tricuspid insufficiency, because of poor general condition of the patient. The thromboembolectomy of aortic bifurcation was performed through the transabdominal approach without trial of Fogarthy catheter embolectomy, because of expectation of the secondary inflammatory changes of the vessel wall and thrombi which was 3 cm X 1 cm X 0.5 cm in size with irregular surfaced solid in consistency. 1 month later, after thromboembolectomy, mitral valve replacement and tricuspid annuloplasty were performed, with successful early operative result. During operation organized thrombi [1 cm X 0.5 cm] in the left auricle was removed. We wonder if simple management using Fogarthy catheter might be possible to remove the thromboemboli instead of thromboembolectomy by aortotomy in this case.

  • PDF