• Title/Summary/Keyword: aortic stenosis

Search Result 262, Processing Time 0.031 seconds

Congenital Quadricuspid Aortic Valve Disease (선천성 사엽성 대동맥 판막 질환)

  • Park Chan Beom;Kim Jae Jun;Jo Min Seop;Jin Ung;Cho Deog-Gon;Park Kuhn;Cho Kyu-Do;Kim Chi Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.780-782
    • /
    • 2005
  • The quadricuspid aortic valve is a rare congenital cardiac morphology. In regard to the hemodynamics of the quadricuspid aortic valve, the regurgitation is most common, the regurgitation accompanying the stenosis or pure stenosis are rare. We report hear a case with quadricuspid aortic valve disease which has been known to be extremely rare.

Clinical Results of Different Myocardial Protection Techniques in Aortic Stenosis

  • Lee, Jung Hee;Jeong, Dong Seop;Sung, Kiick;Kim, Wook Sung;Lee, Young Tak;Park, Pyo Won
    • Journal of Chest Surgery
    • /
    • v.48 no.3
    • /
    • pp.164-173
    • /
    • 2015
  • Background: Hypertrophied myocardium is especially vulnerable to ischemic injury. This study aimed to compare the early and late clinical outcomes of three different methods of myocardial protection in patients with aortic stenosis. Methods: This retrospective study included 225 consecutive patients (mean age, 65{\pm}10 years; 123 males) with severe aortic stenosis who underwent aortic valve replacement. Patients were excluded if they had coronary artery disease, an ejection fraction <50%, more than mild aortic regurgitation, or endocarditis. The patients were divided into three groups: group A, which was treated with antegrade and retrograde cold blood cardioplegia; group B, which was treated with antegrade crystalloid cardioplegia using histidine-tryptophan-ketoglutarate (HTK) solution; and group C, treated with retrograde cold blood cardioplegia. Results: Group A contained 70 patients (31.1%), group B contained 74 patients (32.9%), and group C contained 81 patients (36%). The three groups showed significant differences with regard to the proportion of patients with a New York Heart Association functional classification ${\geq}III$ (p=0.035), N-terminal pro-brain natriuretic peptide levels (p=0.042), ejection fraction (p=0.035), left ventricular dimensions (p<0.001), left ventricular mass index (p<0.001), and right ventricular systolic pressure (p <0.001). Differences in cardiopulmonary bypass time (p=0.532) and aortic cross-clamp time (p=0.48) among the three groups were not statistically significant. During postoperative recovery, no significant differences were found regarding the use of inotropes (p=0.328), mechanical support (n=0), arrhythmias (atrial fibrillation, p=0.347; non-sustained ventricular tachycardia, p=0.1), and ventilator support time (p=0.162). No operative mortality occurred. Similarly, no significant differences were found in long-term outcomes. Conclusion: Although the three groups showed some significant differences with regard to patient characteristics, both antegrade crystalloid cardioplegia with HTK solution and retrograde cold blood cardioplegia led to early and late clinical results similar to those achieved with combined antegrade and retrograde cold blood cardioplegia.

A New Method for Aortic Valve Planimetry with High-Resolution 3-Dimensional MRI and Its Comparison with Conventional Cine MRI and Echocardiography for Assessing the Severity of Aortic Valvular Stenosis

  • Hae Jin Kim;Yeon Hyeon Choe;Sung Mok Kim;Eun Kyung Kim;Mirae Lee;Sung-Ji Park;Joonghyun Ahn;Keumhee C. Carriere
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1266-1278
    • /
    • 2021
  • Objective: We aimed to compare the aortic valve area (AVA) calculated using fast high-resolution three-dimensional (3D) magnetic resonance (MR) image acquisition with that of the conventional two-dimensional (2D) cine MR technique. Materials and Methods: We included 139 consecutive patients (mean age ± standard deviation [SD], 68.5 ± 9.4 years) with aortic valvular stenosis (AS) and 21 asymptomatic controls (52.3 ± 14.2 years). High-resolution T2-prepared 3D steady-state free precession (SSFP) images (2.0 mm slice thickness, 10 contiguous slices) for 3D planimetry (3DP) were acquired with a single breath hold during mid-systole. 2D SSFP cine MR images (6.0 mm slice thickness) for 2D planimetry (2DP) were also obtained at three aortic valve levels. The calculations for the effective AVA based on the MR images were compared with the transthoracic echocardiographic (TTE) measurements using the continuity equation. Results: The mean AVA ± SD derived by 3DP, 2DP, and TTE in the AS group were 0.81 ± 0.26 cm2, 0.82 ± 0.34 cm2, and 0.80 ± 0.26 cm2, respectively (p = 0.366). The intra-observer agreement was higher for 3DP than 2DP in one observer: intraclass correlation coefficient (ICC) of 0.95 (95% confidence interval [CI], 0.94-0.97) and 0.87 (95% CI, 0.82-0.91), respectively, for observer 1 and 0.97 (95% CI, 0.96-0.98) and 0.98 (95% CI, 0.97-0.99), respectively, for observer 2. Inter-observer agreement was similar between 3DP and 2DP, with the ICC of 0.92 (95% CI, 0.89-0.94) and 0.91 (95% CI, 0.88-0.93), respectively. 3DP-derived AVA showed a slightly higher agreement with AVA measured by TTE than the 2DP-derived AVA, with the ICC of 0.87 (95% CI, 0.82-0.91) vs. 0.85 (95% CI, 0.79-0.89). Conclusion: High-resolution 3D MR image acquisition, with single-breath-hold SSFP sequences, gave AVA measurement with low observer variability that correlated highly with those obtained by TTE.

Early Aortic Valve Replacement in Symptomatic Normal-Flow, Low-Gradient Severe Aortic Stenosis: A Propensity Score-Matched Retrospective Cohort Study

  • Kyu Kim;Iksung Cho;Kyu-Yong Ko;Seung-Hyun Lee;Sak Lee;Geu-Ru Hong;Jong-Won Ha;Chi Young Shim
    • Korean Circulation Journal
    • /
    • v.53 no.11
    • /
    • pp.744-755
    • /
    • 2023
  • Background and Objectives: Aortic valve replacement (AVR) is considered a class I indication for symptomatic severe aortic stenosis (AS). However, there is little evidence regarding the potential benefits of early AVR in symptomatic patients diagnosed with normal-flow, low-gradient (NFLG) severe AS. Methods: Two-hundred eighty-one patients diagnosed with symptomatic NFLG severe AS (stroke volume index ≥35 mL/m2, mean transaortic pressure gradient <40 mmHg, peak transaortic velocity <4 m/s, and aortic valve area <1.0 cm2) between January 2010 and December 2020 were included in this retrospective study. After performing 1:1 propensity score matching, 121 patients aged 75.1±9.8 years (including 63 women) who underwent early AVR within 3 months after index echocardiography, were compared with 121 patients who received conservative care. The primary outcome was a composite of all-cause death and heart failure (HF) hospitalization. Results: During a median follow-up of 21.9 months, 48 primary outcomes (18 in the early AVR group and 30 in the conservative care group) occurred. The early AVR group demonstrated a significantly lower incidence of primary outcomes (hazard ratio [HR], 0.52; 95% confidence interval [CI], 0.29-0.93; p=0.028); specifically, there was no significant difference in all-cause death (HR, 0.51; 95% CI, 0.23-1.16; p=0.110), although the early AVR group showed a significantly lower incidence of hospitalization for HF (HR, 0.43; 95% CI, 0.19-0.95, p=0.037). Subgroup analyses supported the main findings. Conclusions: An early AVR strategy may be beneficial in reducing the risk of a composite outcome of death or hospitalization for HF in symptomatic patients with NFLG severe AS. Future randomized studies are required to validate and confirm our findings.

Subvalvular Septal Myectomy and Enlargement of the Narrow Aortic Root in Patients with Aortic Valve Replacement

  • Schulte, H.D.;Birchs, W;Horstkotte, D;Kim, Y.H.;Kerstholt, J;Preusse, C.J.;Winter, J
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.220-224
    • /
    • 1989
  • In candidates for aortic valve replacement [AVR]it is our primary intention to implant the largest possible vale prosthesis of at least 23 mm in diameter in patients with severe valvular aortic stenosis. However, in many patients there is an additional subvalvular asymmetric septal hypertrophy which in some cases may cause an postextrasystolic increase of the LV-aortic gradient. Another component of the aortic stenosis syndrome is a narrow valvular ring, or a combination of both. After complete removal of the diseased valve and decalcification the narrow aortic ring [< 23 mm] can be widened firstly by transaortic subvalvular septal myectomy- [TSM] thus unfolding the left ventricular outflow tract[LVOT]and secondly by extending the oblique aortic incision into the aortic valve ring or further down into the anterior leaflet of the mitral valve. The sub-and supra-valvular defect will be closed by patch enlargement of the aortic root [PEAR] using autologous pericardium. These techniques allow a considerable enlargement of the valvular ring of about 4 to 10 mm in circumference. In a retrospective study using a computerized program, 847 patients with AVR [1980-1984]were reviewed to evaluate the intraoperative hemodynamic results mainly concerning relief of the transvalvular gradient. In 626 patients AVR was performed, 151 patients had double valve replacement [AVR+MVR], and 70 patients had AVR plus additional surgical procedures. Concentrating on the AVR-group [n=626] there were 103 patients with TSM, 24 patients with PEAR and 20 patients with TSM+PEAR which demonstrated that in a total, of 147 patients of this groups [23.5%] an additional procedure was necessary. The Statistical evaluation of the intraoperative pressure measurements before and after AVR in relation to the size of the implanted prostheses indicated the lowest preoperative mean gradient in patients with AVR alone, the highest in patients who afforded TSM plus PEAR. However, after AVR the mean gradients in all three groups were very low [mean 5 to 10 mmHg]. These data indicate that in patients with a narrow aortic ring and additional considerable ASH, TSM and PEAR are suitable techniques to enlarge the aortic root to enable the implantation of an adequate aortic valve prosthesis. Long-term controls have shown that autologous pericardium is a qualified graft material for the ascending aorta.

  • PDF

Traumatic Cardiac Perforation (외상성 심장파열의 외과적 고찰)

  • 성시찬
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.365-370
    • /
    • 1979
  • The first Mitral Commissurotomy was performed for tight mitral stenosis on March 1957. The patient was at that time 22-year-old male, student. The longest follow 9p for 22 years and 8 months has been obtained. During the follow up period, late deterioration due to restenosis developed 4 years after initial good result and reoperation was succeeded by transventricular Mitral Valvotomy with Tubb`s ilator on April 1964. The possible cause of restenosis was attributed to recurrent rheumatic activity. After more than 13 years long-good life following 2nd operation, Endocarditis such as episode of high fever & chill intermittently followed by mild fever and night sweat, I t. tibial artery embolization and rupture of aortic cusp. At present, patient complained of no subjective symptom, enjoying ordinary life {NYHA II]. Blood pressure has been 110/50-60 mmHg, trivial diastolic murmur at apex and moderate degree of mechanical murmur on diastole at Erb`s rea. Neither signs of RVH for mitral stenosis nor sign of LVH. ST-T change for aortic regurgitation appeared yet during last 2 yrs. The patient`s are for prevention of Rheumatic activity and development of endocarditis is important for obtaining the better long-term result.

  • PDF

Acute Abdominal Aortic Occlusion after Open Heart Surgery - A case report - (개심술 후에 발생한 급성 복부 대동맥 차단 -1예 보고-)

  • Han, Won-Kyung;Cho, Joon-Yong;Lee, Jong-Tae
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.710-713
    • /
    • 2005
  • Acute abdominal Aortic occlusion is rare but it is a vascular emergency with high mortality and morbidity. There­fore, delay in diagnosis can have severe impact on the prognosis. A 60-year-old women complained of paresthesia, paralysis, and severe pain in bilateral lower extremities on 13th day after open heart surgery for mitral stenosis, atrial fibrillation, coronary arterial stenosis, tricuspid regurgitation, and atrial septal defect. Her skin was mottled and cool from the umbilicus to the feet, and there were no palpable pulses in the lower exteremities. We diagnosed an acute abdominal aortic occlusion using the Multi-Detector Row Spiral Computed Tomography and successfully treated the problem with emergent thrombo-embolectomy and Aortobifemoral bypass.

Blood Flow Characteristics in the Abdominal Aortic Bifurcation with Stenosis (협착이 발생된 복부대동맥 분기부에서의 혈액운동특성)

  • Yoo, S.S.;Suh, S.H.;Roh, H.W.;Jo, M.T.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.109-112
    • /
    • 1995
  • The three dimensional, steady flows of blood and blood analogue fluids in the abdominal aortic bifurcation are simulated using the finite volume method. The objective of this investigation is to understand the generation and progression of site-specific atherosclerosis from a hydrodynamic point of view. Due to complexity of blood in conducting experimental study, aqueous polymer solutions are used as the substitutional fluids. For comparison purpose of the flow characteristics of blood and substitutional fluids, rheologically different fluids such as water soluble polymers of Carbopol-934 and Separan AP-273 are employed for the numerical simulation. In order to understand the role of hydrodynamics in the formation and development of atherosclerosis lesions flow velocities, pressures and shear stresses along the vessel are calculated for steady flows.

  • PDF