A Micro Shunt Valve with Anti-siphon Effect

  • Lee, Sang-Wook;Yoon, Hyeun-Joong;Yang, Sang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권1호
    • /
    • pp.31-34
    • /
    • 2004
  • This paper presents the fabrication and testing of a two-way pressure regulation micro shunt valve with an anti-siphon effect that can be implanted in hydrocephalus patients. This micro shunt valve consists of a silicone rubber membrane and a valve seat for the opening pressure control as well as the anti-siphon behavior. The two-way pressure regulation and the anti-siphon effect of the micro shunt valve are verified experimentally for various sizes of membranes and valve seats.

Analysis of Design Parameters For Shunt Valve and Anti-Siphon Device Used to Treat Patients with Hydrocephalus

  • Lee, Chong-Sun;Jang, Jong-Yun;Suh, Chang-Min
    • Journal of Mechanical Science and Technology
    • /
    • 제15권7호
    • /
    • pp.1061-1071
    • /
    • 2001
  • The present study investigated design parameters of shunt valves and anti-siphon device used to treat patients with hydrocephalus. The shunt valve controls drainage of cerebrospinal fluid (CSF) through passive deflection of a thin and small diaphragm. The anti-siphon device(ASD) is optionally connected to the valve to prevent overdrainage when the patients are in the standing position. The major design parameters influencing pressure-flow characteristics of the shunt valve were analyzed using ANSYS structural program. Experiments were performed on the commercially available valves and showed good agreements with the computer simulation. The results of the study indicated that predeflection of the shunt valve diaphragm is an important design parameter to determine the opening pressure of the valve. The predeflection was found to depend on the diaphragm tip height and could be adjusted by the diaphragm thickness and its elastic modulus. The major design parameters of the ASD were found to be the clearance (gap height) between the thin diaphragm and the flow orifice. Besides the gap height, the opening pressure of the ASD could be adjusted by the diaphragm thickness, its elastic modulus, area ratio of the diaphragm to the flow orifice. Based on the numerical simulation which considered the increased subcutaneous pressure introduced by the tissue capsule pressure on the implanted shunt valve system, optimum design parameters were proposed for the ASD.

  • PDF

소아에서 틈새뇌실 증후군 : 임상 양상 및 치료 (Slit Ventricle Syndrome in Children : Clinical Presentation and Treatment)

  • 신범식;양국희;김동석;최중언
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권sup2호
    • /
    • pp.309-315
    • /
    • 2001
  • 틈새뇌실증후군은 수두증으로 션트술을 시행받은 환아에서 CT나 MRI소견상 틈새처럼 좁은 뇌실을 가지고 있으면서 간헐적으로 두통, 구토 또는 의식장애등이 동반되는 질환이다. 1986년부터 1996년까지 총 821명의 환자가 수두증으로 션트술을 시행받았다. 이 환자들의 수두증의 원인은 뇌종양(140명), 출혈(62명), 정상압수두증(64명), 뇌수막염(58명), 외상(54명), 선천성(48명), 뇌낭미충증(31명), 그리고 이유를 알 수 없었던 경우가 364명으로 나타났다. 평균 추적 관찰 기간은 68개월이었으며 총 232명에서 재수술을 시행하였으며 1인당 1.28회의 재수술율을 보였다. 이들중 틈새뇌실 증후군은 6예로 0.7%였다. 틈새뇌실증후군 대부분의 환자는 영아기에 수술을 시행받았다. 처음 수술로부터 틈새뇌실증후군이 발생하기까지의 기간은 4~8년으로 평균 6년후 틈새뇌실증후군이 발생하였다. 동위원소 검사상 6예에서 션트의 기능은 모두 정상이었다. 증상이 경미한 2명의 환자에서는 보존적 치료를 시행하였는데 치료후 증상의 호전을 보였다. 이 환자들은 뇌압측정을 시행하지 않았다. 6명중 1명은 뇌압 측정시 높게 나타나 기존과 같은 압력밸브를 이용하여 재수술을 시행하였다. 3명의 환자는 낮은 뇌압을 보여 안티사이펀밸브나 기존보다 높은 압력의 밸브를 이용하여 재수술을 시행하였다. 틈새뇌실증후군의 치료는 첫째, 증후군의 양상을 정확하게 판단하여, 둘째, 증상을 완화시킬 수 있는 방향으로 치료방침을 설정해야 할 것으로 생각되었다.