• Title/Summary/Keyword: anti-siphon

Search Result 3, Processing Time 0.018 seconds

A Micro Shunt Valve with Anti-siphon Effect

  • Lee, Sang-Wook;Yoon, Hyeun-Joong;Yang, Sang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.1
    • /
    • pp.31-34
    • /
    • 2004
  • This paper presents the fabrication and testing of a two-way pressure regulation micro shunt valve with an anti-siphon effect that can be implanted in hydrocephalus patients. This micro shunt valve consists of a silicone rubber membrane and a valve seat for the opening pressure control as well as the anti-siphon behavior. The two-way pressure regulation and the anti-siphon effect of the micro shunt valve are verified experimentally for various sizes of membranes and valve seats.

Analysis of Design Parameters For Shunt Valve and Anti-Siphon Device Used to Treat Patients with Hydrocephalus

  • Lee, Chong-Sun;Jang, Jong-Yun;Suh, Chang-Min
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1061-1071
    • /
    • 2001
  • The present study investigated design parameters of shunt valves and anti-siphon device used to treat patients with hydrocephalus. The shunt valve controls drainage of cerebrospinal fluid (CSF) through passive deflection of a thin and small diaphragm. The anti-siphon device(ASD) is optionally connected to the valve to prevent overdrainage when the patients are in the standing position. The major design parameters influencing pressure-flow characteristics of the shunt valve were analyzed using ANSYS structural program. Experiments were performed on the commercially available valves and showed good agreements with the computer simulation. The results of the study indicated that predeflection of the shunt valve diaphragm is an important design parameter to determine the opening pressure of the valve. The predeflection was found to depend on the diaphragm tip height and could be adjusted by the diaphragm thickness and its elastic modulus. The major design parameters of the ASD were found to be the clearance (gap height) between the thin diaphragm and the flow orifice. Besides the gap height, the opening pressure of the ASD could be adjusted by the diaphragm thickness, its elastic modulus, area ratio of the diaphragm to the flow orifice. Based on the numerical simulation which considered the increased subcutaneous pressure introduced by the tissue capsule pressure on the implanted shunt valve system, optimum design parameters were proposed for the ASD.

  • PDF

Slit Ventricle Syndrome in Children : Clinical Presentation and Treatment (소아에서 틈새뇌실 증후군 : 임상 양상 및 치료)

  • Shin, Beom-Sik;Yang, Kook-Hee;Kim, Dong-Seok;Choi, Joong-Uhn
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.309-315
    • /
    • 2001
  • The term slit ventricle syndrome(SVS) refers to an episodic occurrence of headache, vomiting, and possibly some degree of impaired consciousness in shunted hydrocephalic children in whom slit-like ventricles are seen on CT scan or MRI. Authors present 6 cases with SVS who were treated at our institute for last 10 years. From 1986 to 1996, 821 patients underwent shunt surgery for hydrocephalus. The etiology of hydrocephalus included brain tumor(140 patients), post-hemorrhagic(62 patients), idiopathic normotensive hydrocephalus(64 patients), post-meningitic( 58 patients), post-traumatic(54 patients), congenital(48 patients), neurocysticercosis(31 patients), and unknown etiology(364 patients). During the mean follow-up duration of 68 months, 232 shunt revisions were performed by a revision rate of 1.28 per patient. The incidence of SVS was 0.7%(6 patients). Most of them have been operated on in infancy. Time interval from the first operation to the development of slit-ventricle syndrome ranged from 4 to 8 years, the mean was 6 years. Shuntogram showed patent shunt in all patients. Two patients with less severe clinical symptoms improved with conservative treatment. These patients were not measured ICP because of good hospital course. One patient showed high ICP and needed only revision with same pressure valve as previous shunt. Low ICP was noted in 3 patients. Pressure augmentation using an anti-siphon device(ASD) or upgrading valve system were necessary in these patients. The authors stress that determining type of SVS is the first step in treatment planning and that the best treatment is a strategy aimed at resolving the specific type of SVS responsible for the symptoms.