• Title/Summary/Keyword: anti-compression

Search Result 80, Processing Time 0.028 seconds

Mechanical Properties and Surface Morphology of Cotton Fabrics Dyed with Persimmon Juice (감즙 염색에 의한 면직물의 역학적 특성과 표면형태)

  • Huh, Man-Woo
    • Textile Coloration and Finishing
    • /
    • v.24 no.4
    • /
    • pp.296-304
    • /
    • 2012
  • For development of dyeability, the cotton fabric was dyed repeatedly with persimmon juice by padding mangle. We evaluated the mechanical properties and hand value by Kawabata Evaluation System, and observed the change of surface morphology. The results obtained from this study were as follows. With the increase of repeating padding times of dyeing, the linearity of load-extension curve and tensile energy per unit length of the cotton fabric were increased, but the tensile resilience of fabric was decreased. The value of shear stiffness and shear hysteresis were increased. Also compression resilience and linearity of compression thickness curve were increased. The cotton fabric dyed with persimmon juice had shown the thickness and weight increase as the number of padding increase. As repeating times of dyeing with persimmon juice were increased, among the 6 hand values, the item of stiffness, anti-drape stiffness, fullness and softness were increased, while flexibility with soft feeling and crispness were greatly decreased. The amount of coated persimmon juice on the surface of the fabric was gradually increased as the padding times of dyeing. And cotton fabrics were dyed evenly with persimmon juice by padding mangle.

Physicomechanical Properties Enhancement of Fast-Growing Wood Impregnated with Wood Vinegar Animal Adhesive

  • Efrida BASRI;SAEFUDIN;Mahdi MUBAROK;Wayan DARMAWAN;Jamal BALFAS;Yelin ADALINA;Yusuf Sudo HADI
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.6
    • /
    • pp.542-554
    • /
    • 2023
  • This study is a continuation of our previous work, which focused on the resistance of jabon wood to termites after impregnation with wood vinegar (WV) and animal-based adhesive (kak). This paper presents the physicomechanical properties of fast-growing jabon wood impregnated with kak at two concentrations (8% and 10%) in wood vinegar or water as a solvent with and without 4% borax. The physical properties of the impregnation solution, that is, viscosity, density, pH, and solid content, were evaluated according to SNI 06-4567-1998. Some physical parameters, such as weight percent gain (WPG), density, water uptake, anti-swelling efficiency (ASE), crystallinity, and mechanical properties, i.e., modulus of elasticity (MOE), modulus of rupture (MOR), and compression strength parallel to the grain (CS), of the impregnated wood were determined. Based on these results, wood impregnated using a mixture of kak in WV presented better physical (increased WPG, density, dimensional stability, and crystallinity) and mechanical (increased MOE/MOR and compression strength) properties than wood impregnated with a water solvent or untreated wood. The wood impregnated using WV and water solvent improved the physical and mechanical properties. The density of the wood increased by 44%-58% and 32%-47%, ASE radial-tangential increased by 38%-45%; 15%-28% after 24 h of water immersion, crystallinity increased by 59%-74%; 36%, MOE increased by 46%-57%; 28%-31%, MOR increased by 29%-34%; 14%-27%, and compression strength increased by 40%-76%; 38%-72% values to untreated wood.

Effects of Tumor Necrosis Factor Alpha Blocker Adalimumab in Experimental Spinal Cord Injury

  • Borcek, Alp Ozgun;Civi, Soner;Ocal, Ozgur;Gulbahar, Ozlem
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.2
    • /
    • pp.73-76
    • /
    • 2015
  • Objective : Tumor necrosis factor alpha (TNF-${\alpha}$) have proven effects in pathogenesis of neuroinflammation after spinal cord injury (SCI). Current study is designed to evaluate the effects of an anti-TNF-${\alpha}$ agent, adalimumab, on spinal cord clip compression injury in rats. Methods : Thirty two male adult Wistar rats were divided into four groups (sham, trauma, infliximab, and adalimumab groups) and SCI was introduced using an aneurysm clip. Animals in treatment groups received 5 mg/kg subcutaneous adalimumab and infliximab right after the trauma. Malondialdehyde (MDA) levels were studied in traumatized spinal cord tissues 72 hours after the injury as a marker of lipid peroxidation. Results : Animals that received anti-TNF-${\alpha}$ agents are found to have significantly decreased MDA levels. MDA levels were significantly different between the trauma and infliximab groups (p<0.01) and trauma and adalimumab groups (p=0.022). There was no significant difference in neurological evaluation of the rats using Tarlov scale. Conclusion : These results suggest that, like infliximab, adalimumab has favorable effects on lipid peroxidation induced by spinal cord trauma in rats.

Two Dimensional Size Effect on the Compressive Strength of T300/924C Carbon/Epoxy Composite Plates Considering Influence of an Anti-buckling Device (T300/924C 탄소섬유/에폭시 복합재 적층판의 이차원 압축 강도의 크기효과 및 좌굴방지장치의 영향)

  • ;;;C. Soutis
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.88-91
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section (length x width) was investigated on the compressive behavior of a T300/924 [45/-45/0/90]3s, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a 30$\times$30, 50$\times$50, 70$\times$70, and 90mm$\times$90mm gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

  • PDF

Anti-Parallel Diode Pair(APDP) Mixer over 3~5 GHz for Ultra Wideband(UWB) Systems (역병렬 다이오드를 이용한 초광대역 시스템용 3~5 GHz 혼합기 설계)

  • Jung Goo-Young;Lee Dong-Hwan;Yun Tae-Yeoul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.7 s.98
    • /
    • pp.681-689
    • /
    • 2005
  • This paper presents an ultra wide band(UWB) mixer using anti-parallel diode pair(APDP) with simulation and measurement results. The proposed mixer adopts the even-harmonic direct conversion mixing, which consists of a couple of filter, in-phase wilkinson power divider, wideband $45^{\circ}$ power divider, and APDP. The m mixer is operating over 3.1 to 4.8 GHz and producing quadrature(I/Q) outputs with a conversion loss of 18 dB and input third order intercept point($IIP_3$) of 15 dBm. I/Q outputs also have difference of about 0.5 dB and phase difference of ${\times}3^{\circ}$ and $P_{1dB}$ of 2 dBm.

Pressure and temperature change in air cylinders in charged or discharged case

  • Takeuchi, Masaaki;Kagawa, Toshiharu;Nomura, Naoki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.298-301
    • /
    • 1993
  • In pneumatic systems the temperature changes during operation owing to air compression or expansion, friction of air movement and friction between solid interface. The temperature change usually ha undesirable influence on process. To attain higher quality of pneumatics, studies in thermo-fluid dynamics is needed. This paper presents experimental results anti theoretical analysis on the temperature change by air charge and discharge to cylinders, which has no piston yet. The temperature increase by charge shows a strong, dependence on axial location along the cylinder, which is proved in theoretical analysis. The temperature decreases by discharge shows rather uniform in the cylinder, which is also proved by theory.

  • PDF

VOSKIN 125+® instrument, a landmark in the history of massage; painkiller

  • Chang, Tae-soun
    • CELLMED
    • /
    • v.6 no.3
    • /
    • pp.18.1-18.4
    • /
    • 2016
  • Patients often suffer from continuous pain negatively affecting their daily life despite a surgical operation. Various studies on complementary therapies against pain have been accumulated as patient with pain desires the improvement in quality of life. Massage therapy as a complementary therapy has been applied widely to decrease the pain and promote relaxation. Thermotherapy with massage is also useful for the treatment of musculoskeletal disorders. Here, the author reports that VOSKIN 125+®, a new massage instrument, was designed directly to be adjusted from 38-50 degrees Celsius depending on the individual symptoms by lifting the skin and muscles with a negative compression in illness area for alleviating all pain. It transfers pressure and heat to area of illness and eases the pain. In addition, it has significant anti-inflammatory effects and promotes metabolism activity. VOSKIN 125+® can be therapeutic for pain of musculoskeletal patients. Therefore, I suggest that VOSKIN 125+® can be useful for a great number of patients suffering from persisting pain.

Tribological Characteristics with Purity Zirconia of Compression Ring Materials in Piston (피스톤 압축 링 재료의 지르코니아 순도에 따른 트라이볼로지 특성)

  • Oh, Seong-Mo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.5
    • /
    • pp.91-96
    • /
    • 2006
  • The friction and wear properties of ceramics are very important in the applications to engineering ceramic parts such as seal rings, pump parts, automobile meter parts, and so on. In this study, the effects of each other purity on the mechanical and tribological properties of purity zirconia ceramics were investigated. Also in order to determine the effects of sliding distance, sliding speed, contact load, friction coefficient, the amount of worn out material at a certain time, and the prepared composites were measured. Crystalline phases and microstructure were examined with XRD and SEM. The results show that we obtained the good properties of friction coefficient and wear resistance at the purity 99.5% of zirconia. than this of the purity 95% were great at the wear amount of worn out material.

Abrasion Resistance Property of the Magnesia Phosphate Ceramics(MPC) Artificial Stone Using the Waste Porcelain (폐자기를 사용한 마그네시아 인산염 세라믹(MPC) 인조석재의 내마모특성)

  • Yoo, Yong-Jin;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.51-52
    • /
    • 2014
  • Recently, it is the global warming phenomenon because of the greenhouse gas exhaustion caused by and the environment problem is serious. And it is the situation where the problem of the exhaustion of resource because of the indiscriminate picking of the that is the raw material of the cement, limestone and natural aggregate are emphasized. In addition, thus the cement reduction amount of use and substitute material research is the urgent actual condition with the gas emission, which here it is generated in conducting compression molding in the building stone manufacturing process performance degradation phenomenon and fire resistance, and problem of the durability. Therefore, in this research, because of being the magnesia phosphate ceramics, the waste porcelain is applied and the anti-wearing character of the artificial stone according to it tries to be investigated.

  • PDF

End-Gas Temperature Measurments in a DOHC Spark-Ignition Engine Using CARS (CARS를 이용한 DOHC 스파크 점화 기관의 말단 가스 온도 측정)

  • 최인용;전광민;박철웅;한재원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.122-128
    • /
    • 1999
  • CARS(Coherent anti-Stokes Raman Spectroscopy) temperature measurement under engine-like condition was validated by measuring unburned gas temperatures of premixed propane-air flame in a constant volume combustion chamber. The measured temperatures were compared with predictions of 2 zone flame propagation model. End-gas temperatures were measured were measured by CARS technique in a conventional 4 cylinder DOHC spark-ignition engine fueled with PRF 80. Cylinder pressure was measured simultaneously with CARS signal and used as a parameter on fitting CARS spectrum to library of theoretical spectra. There was a good agreement between the measured temperature and adiabatic core temperature calculated from measured cylinder pressure. Significant heating by pre-flame reaction in the gas was observed in the late part of compression stroke.

  • PDF