• 제목/요약/키워드: anthracite media

검색결과 20건 처리시간 0.026초

안쓰라사이트 여재 원형도가 여과 효율에 미치는 영향 (The Effects of Anthracite Media Sphericity on Filtration Efficiency)

  • 정원석;최승일
    • 상하수도학회지
    • /
    • 제21권6호
    • /
    • pp.763-770
    • /
    • 2007
  • There are many design parameters affecting filtration efficiency such as filteration rate, media packing depth, size distribution, and so on. The sphericity, the ratio of the surface area of an equal volume sphere to the real surface area of the particles, is one of major physical characters of media. The effect of sphericity on the performance of anthracite filter has been investigated. Media from eight water treatment plants have been collected. The sphericity of each media has been calculated by using well known headloss equations such as Kozeny equation, Dahmarajah equation etc.. Columns packed with anthracite media having different sphericity have been used to compare headloss development, floc accumulation in the bed, particles in bed water, filtrate turbidities after backwash and so on. The repeated experiments have indicated that the sphericity of anthracite media may not have remarkable influence on the filter performance as it has been suspected. It also has been prospected in the experiment that the media of higher sphericity would store more particles in the bed and give better filtrate quality, if provided that the effective size and the size distribution of media would be the same.

여과재(濾過材)의 종류(種類)에 따른 최소유동상(最小流動狀) 속도(速度) 및 팽창(膨脹)에 관한 연구(硏究) (A Study on the Minimum Fluidization Velocity and Expansion of Various Media)

  • 최승일;최준석
    • 상하수도학회지
    • /
    • 제10권2호
    • /
    • pp.55-69
    • /
    • 1996
  • Backwashing is one of the most important processes in water treatment. Several models have been utilized to predict minimum fluidization velocity and expansion of media. However, it is not unusual that the actual bahavior of media dose not agree well with the prediction. This study has investigated the applicability of models in predicting the minimum fluidization velocity of sand media. However even the better model has predicted minimum fluidization velocity 1.1 to 1.8 times higher than actual fluidization velocity. The expansion rate of sand media was inspected. It is found that the actual expansion rate was greater than the predicted. In this study condition, use of $d_{10}$ instead of $d_{60}$ was better to predict the expansion of media. On the contrary to the sand media, the actual expansion of anthracite media was less than that predicted. Sometimes it is reported that the dual media has been overflown during backwashing and mixed severely at the interface. It is because the grain size distribution of anthracite has not been selected properly. The numerical values for media expansion found in this study could be referred as the useful data in operating and/or designing filter media.

  • PDF

여재 종류에 따른 역삼투법 해수담수화 시설 전처리 여과공정의 성능비교 (Comparison of the filtration performance by different media in pretreatment of seawater desalination by reverse osmosis)

  • 김승현;윤종섭;이석헌
    • 상하수도학회지
    • /
    • 제23권2호
    • /
    • pp.215-222
    • /
    • 2009
  • This study compares the performance of the filters with various media in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is used as raw water. The filter performance is evaluated by the filtrate quality and the head loss development. Five media is selected in this study: anthracite, $Filtralite^{(R)}$, sand, Pumice, $AFM^{(R)}$. These media are used in combination for dual media filter and alone for mono media filter. The comparison results show that NC0.8-1.6 is the best $Filtralite^{(R)}$. The dual media filter of NC0.8-1.6 and sand outperformed other filters in particle removal. The dual media filter of anthracite and sand showed good performance in organic removal. The mono media filter of Pumice produced the similar filtrate quality as the mono media filter of sand although the effective size of Pumice is considerably greater than that of sand. Due to big size, head loss development is maintained slow in the filtration of Pumice.

일유량 변동에 따른 여과수질 악화에 대처하기 위한 최적 여재구성에 관한 연구 (The Optimal Composing the Filter-Bed for Coping with Daily Flow-Rate Fluctuation for the Performance of Sand Filtration Process)

  • 박동학;박노석;김성수;배철호;정남정;최승일
    • 상하수도학회지
    • /
    • 제21권4호
    • /
    • pp.485-491
    • /
    • 2007
  • The fluctuation of inlet flow to a water treatment plant makes a serious problem that it can change the filtration rate abruptly, and ultimately occur the breakthrough of the detained particles inside filter media. Also, since it takes very short time (about 10 minutes) for the surface wave occurred from the fluctuation of inlet flow to reach the filtration process, it is impossible to control the filtration rate stably. Therefore, this study was conducted to evaluate the effect of daily flow-rate fluctuation on the performance of sand filtration process, and to suggest the dual media composition for coping with that effect. Comparative column tests have been carried out for various dual media (sand and anthracite) compositions. From the results of column tests, dual media, especially in the case of sand 45cm/anthracite 30cm, is more effective to cope with the effect of flow-rate fluctuation on the performance of filtration than single media (only sand). In addition, irrespective of dual media composition, managing ability to cope with that fluctuation tends to be weak at the end of allowable filtration duration time,

여과재를 활용한 건물옥상유출 초기빗물의 부유물질 저감 (Reduction of Suspended Solids in First Flush from a Building Rooftop using Various Media)

  • 김성범;이원태
    • 대한환경공학회지
    • /
    • 제39권4호
    • /
    • pp.214-219
    • /
    • 2017
  • 건물의 우수관에 연결하여 초기빗물의 부유물질을 처리할 수 있는 장치를 개발하기 위하여 건물옥상 유출 빗물의 수질특성 변화를 파악하고 다양한 여재를 활용해 초기빗물의 부유물질 제거를 연구하였다. 건물옥상 유출빗물의 입자성 물질은 대부분 $10{\sim}30{\mu}m$의 크기로, 부유물질 농도는 강우시 초기 10~20분까지 높았고 점진적으로 감소하였다. 옥상유출빗물의 용존성 유기물과 무기물의 농도도 유출 초기에 높게 나타났다. Anthracite (AC), Polyurethane (PU), Polypropylene (PP) 여재로 여과시 초기에 50%의 부유물질을 제거할 수 있었으나 20분 이상 여과시 제거율이 급격히 낮아졌다. 세척후 반복여과를 고려하면 AC 여재만 9회까지 재사용가능하였다. 여재층의 높이가 높을수록, 통과유량이 적을수록 시간에 따른 SS 제거율 감소폭은 적었고, 여재층 30 cm, 유량 12 L/min 이하로 운전할 경우 초기빗물(SS = 450 mg/L)의 SS 제거율 50%를 달성할 수 있었다.

낙동강 하류원수에 적합한 여과지의 여재구성 (The adaptive filter configuration for down stream of Naktong river)

  • 김상구;류동춘
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.481-488
    • /
    • 1995
  • This study was carried out to evaluate the variations of headloss rate and of specific deposit to depths with effective size of media and configuration of filter layer during algae blooming period. 0.51mm size media was disqualified because most of headloss occurred rapidly below 5cm from surface layer however 0.91mm size media acted deep filtration more than 20cm from top, as result 0.91mm sixte media filter had 2~3 times longer filtration time than 0.51mm sixte media filter, but 0.91mm size media have break-through potentiality. multi-layer filter with 1.02mm anthracite and 0.51mm sand had large deposit volume in upper layer that could longer filtration time, moreover smaller media in lower layer that could protect break-through.

  • PDF

수중의 철 제거 시 생기는 산화철의 결정구조에 관한 연구 (On the Crystalline Structures of Iron Oxides formed During Removal Process of Iron in Water)

  • 조봉연
    • 대한토목학회논문집
    • /
    • 제26권1B호
    • /
    • pp.107-111
    • /
    • 2006
  • 2종류의 제철 반응조에 있어서, 각종의 반응조건 하에 생성한 산화철을 x-ray회절과 M$\ddot{o}$ssbauer spectroscopy실험으로 철산화 물질을 동정한 결과, 여재 표면에 부착한 철 산화물의 결정은 pH 조건에 관계없이 Ferrihydrite($Fe_5HO_8{\cdot}4H_2O$)이었으며, Batch(회분) 실험에서 생긴 철 산화 물질은 가수분해에 의해 생긴 것으로, Microcrystalline Goethite 이었다.

지하저수지(ASR) 유입수 전처리기법 개발: 물리적 폐색 저하 및 수량공급원활을 위한 2 단계 급속여과지 (Development of pre-treatment for the injection water into the aquifer storage and recovery(ASR) in Korea: The two-step rapid filter to reduce physical clogging and secure the volume of the injected water)

  • 박병주;도시현;홍성호
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.337-345
    • /
    • 2015
  • Two step rapid filter system as a pre-treatment for the injected water into aquifer storage and recovery (ASR) in Korea was developed to reduce physical blockage and secure the volume of the injected water. First, single rapid sand filters with three different media sizes (0.4~0.7, 0.7~1.0 and 1.0~1.4 mm) were tested. Only two sizes (0.4~0.7 and 0.7~1.0 mm) satisfied target turbidity, below 1.0 NTU. However, they showed the fast head loss. To prevent the fast head loss and secure the volume of the injected water, a rapid anthracite filter with roughing media size (2.0~3.4 mm) were installed before a single rapid sand filter. As results, both the target turbidity and reduction of head loss were achieved. It was determined that the media size for a rapid sand filter in two step rapid filter system (i.e. a rapid anthracite filter before a rapid sand filter) was 0.7~1.0 mm. In addition, the effects of coagulant doses on the removal of natural organic matter (NOM), which might cause a biological clogging, were preliminarily evaluated, and the values of $UV_{254}$, dissolved organic carbon (DOC) and SUVA were interpreted.

A column study of effect of filter media on the performance of sand filter

  • Kim, Tae-hoon;Oh, Heekyong;Eom, Jungyeol;Park, ChulHwi
    • Membrane and Water Treatment
    • /
    • 제11권4호
    • /
    • pp.247-255
    • /
    • 2020
  • Sand filter is a key unit process for particle removal in water purification treatments. Its long-standing use is due to on-site customized retrofit. Proper selection of filter media is one of the retrofit approaches to improve filter performance. This study described a series of controlled laboratory column tests and examined the effects of media property on filtration and backwash. When sand media of 0.51 mm in effective size was replaced by sand of 0.60 mm, the filter run increased up to 5 times in the given bed depth. The change of media property required an increase of backwash rate by 0.05 m/min to satisfy the requirement of bed expansion, more than 20%. When the anthracite was changed with lower effective size and uniformity coefficient, correlation with sand in the filter bed could be satisfied within the permissible error between media and bulk characteristics. Besides, this selection resulted in a well-stratified configuration of media layers after bed expansion. The column study showed that the correlation of property between the dual media had a significant effect on the filter productivity and backwash interval.

여과지에서 여재 원형도 결정 방법에 대한 연구 (Integrated Method to Determine the Sphericity of Filter Media)

  • 정원석;최승일
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.565-571
    • /
    • 2005
  • The method to decide media sphericity on the filter has been investigated. The sphericity, the ratio of the surface area of an equal volume sphere to the real surface area of the particles, is one of major physical characters of media affecting the bed expansion during backwash. The media in each treatment plant may have different sphericity, and the sphericity of the media in the filter may be changed as backwashing has been conducted regularly for a long time. Media from twelve water treatment plants under KOWACO have been collected and selected to insure various and practical sphericities. The sphericity of each media has been calculated by using well known equations. For example, Kozeny equation, Dahmarajah equation and so on. The experiment results have indicated that the sphericity of each water treatment plant is different. Although the sphericity values measured by different methods were turned out to be diverse values, the order in the magnitude seemed to be the same. The sphericity values of sand media were in the range of 0.71-0.82 and those of anthracite were placed between 0.49 and 0.56 by the Dharmarajah equation.