• 제목/요약/키워드: annual energy production

검색결과 212건 처리시간 0.028초

풍력단지 출력 검증을 위한 기상탑의 최적위치 선정 (Optimal Location of Meteorological Mast for Power Curve Verification of Wind Farm)

  • 오기용;이준신;박준영;이재경;김지영
    • 신재생에너지
    • /
    • 제5권2호
    • /
    • pp.31-38
    • /
    • 2009
  • The performance test of a wind turbine in a wind farm is generally carried out by the owner to verify the power curve of the wind turbine given by the turbine manufacturer. The international electro-technical commission provides the IEC 61400-12-1 standard on "Power performance measurements of electricity producing wind turbines". By using this code, one can easily find the suitable met-mast (meteorological mast) location for the wind data whether a wind farm is potential or already built. In this paper, the valid sectors for wind turbines installed in the HanKyoung wind farm, south-west in Jeju island are analyzed on the basis of the code by considering the wind farm layout. Among these sectors, the optimal met-mast location is presented for the power curve verification of the wind farm.

  • PDF

지역냉방 열원의 수요모형에 관한 연구 (A Study on the Demand Modelling for District Cooling Energy Source)

  • 김진형;최병렬
    • 자원ㆍ환경경제연구
    • /
    • 제11권4호
    • /
    • pp.633-657
    • /
    • 2002
  • This study presents a demand modelling for landfill gas, which is used as alternative energy source for district cooling business. By analyzing the cost minimizing behavior of producer facing with three alternative energy sources such as electricity, cooling heat water, and gas, a demand function for landfill gas is derived from the optimal operating time of gas fired production facility, and estimated using unpublished data, which are associated with Seoul city's development plan for Sang-am area. The estimation results repeals that Seoul City could supply the land-fill gas of 13.76 million cubic meters each year at the price of about 16 won per cubic meters. However, if the investment costs associated with installation of gas collecting facilities are treated as sunk costs, annual amount of gas supplied is expected to increase to 14.22 million cubic meters at a lower unit price of 14.76 won.

  • PDF

풍력 터빈의 요 제어에 따른 하중 및 성능 영향성 평가 (Assessment of Wind Turbine Load and Performance Effects by Yaw Control)

  • 김진;김지언;고장욱;권기영
    • 풍력에너지저널
    • /
    • 제4권1호
    • /
    • pp.46-52
    • /
    • 2013
  • The wind generally includes turbulence characteristics in nature. So the yaw errors between wind turbine direction and wind direction occur due to turbulence fluctuation. The yaw errors affect the fatigue load of wind turbine system and power reduction. The components of turbulence intensity are different from those of each site where the wind turbines are installed. We studied that the fatigue load and power efficiency are improved by controlling yaw motions. In this study, we controlled the averaged yaw error time according to site conditions by turbulence intensity.

경기 남부지역 풍력자원의 평가와 농업분야 활용방안 (Assessment and Agricultural Use of Wind Resources in Southern Part of Gyeonygi Province)

  • 홍성구
    • 한국농공학회논문집
    • /
    • 제48권3호
    • /
    • pp.73-82
    • /
    • 2006
  • Wind energy is one of the promising renewable energies that could provide electricity and other mechanical power. Wind energy market is dramatically growing in many European countries, but wind power is only 0.2% of the total renewable energy uses that is only about 2% of the primary energy consumption in Korea. It is widely accepted that wind resources fur power generation are only limited in some areas including coastal regions and mountainous areas in Gangwon province in Korea, particularly in terms of large scale wind power developments. In this study, wind velocity data were analyzed with respect to the potential utilization. The data provided from National Weather Service were used for the analysis. In addition, field wind data were also collected and analyzed for the comparison between the national data. The comparison showed that there were significant differences between the experimental station and the national station that are about 5km away. Annual average wind speed at the experimental station was less than 2 m/s, which is not enough fur wind power generation. It seemed that the topographic condition resulted in a significant difference in wind speed. When 600 W and 2.5 kW wind turbines were used, annual power productions were only 186 kWh and 598 kWh, respectively. When the average wind speed is lower, wind pumping is an alternative use of wind. At the experimental station, the average pumping rate of $3m^3/h$ at the head of 3 m was expected at a 2.5 m rotor under the conditions that efficiencies of the rotor and the pump were 40% and 80%, respectively. It did not seem that the wind pumping was not applicable at the station either. A higher wind speed was required to install the wind machines. Meanwhile, wind pumping would be applicable in conditions with lower pumping heads. Other applications were introduced far further wind energy utilization, including wind powered ventilation and friction heat generation in greenhouses.

Modelling of On-Site Energy Consumption Profile in Construction Sites and a Case Study of Earth Moving

  • Yi, Kyoo-Jin
    • Journal of Construction Engineering and Project Management
    • /
    • 제3권3호
    • /
    • pp.10-16
    • /
    • 2013
  • The annual expenditure on diesel oil and heavy oil in the construction sector is the second largest among all industrial sectors. According to the greenhouse reduction scheme of Korean Government, construction sector targeted 7.1% reduction by 2020. Although this target is not higher than other industrial sectors, it is not easy to achieve the reduction target without radical advance in technology, which cannot be expected to happen soon, considering the conservative characteristics of construction industry. Most researches on environmental issues focus on the issues related to energy saving matters during material production stage or maintenance stage, such as heating and insulation, and few deal with the issues directly related to the energy use in the construction sites. This research regards the operation of equipment for the on-site construction processes as a system and attempts to model the energy use processes related to the activities in construction sites, and provides simulation results of earth excavation and hauling processes. The result of this research is expected to aid construction planners estimating the time-based patterns of energy use and assessing greenhouse gas emission and to help selecting more energy efficient alternatives at the planning stage.

SYSTEM MODELLING OF ON-SITE ENERGY CONSUMPTION PROFILE IN CONSTRUCTION SITES AND A CASE STUDY OF EARTH MOVING

  • Kyoo-Jin Yi
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.287-293
    • /
    • 2013
  • The annual expenditure on diesel oil and heavy oil in the construction sector is the second largest among all industrial sectors. According to the greenhouse reduction scheme of Korean Government, construction sector targeted 7.1% reduction by 2020. Although this target is not higher than other industrial sectors, it is not easy to achieve the reduction target without radical advance in technology, which cannot be expected to happen soon, considering the conservative characteristics of construction industry. Most researches on environmental issues focus on the issues related to energy saving matters during material production stage or maintenance stage, such as heating and insulation, and few deal with the issues directly related to the energy use in the construction sites. This research regards the operation of equipment for the on-site construction processes as a system and attempts to model the energy use processes related to the activities in construction sites, and provides simulation results of earth excavation and hauling processes. The result of this research is expected to aid construction planners estimating the time-based patterns of energy use and assessing greenhouse gas emission and to help selecting more energy efficient alternatives at the planning stage.

  • PDF

캐나다 앨버타주의 수소산업 현황 및 전망 (The Present Condition and Outlook of Hydrogen Industry in Alberta, Canada)

  • 문상호;이원석;이영수
    • 한국가스학회지
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2021
  • 한국의 수소경제 활성화 로드맵에 의하면 2040년 526만톤의 연간 수소공급이 필요하며 이 중 해외 생산부분이 50%를 담당해야 할 것으로 설정하였으나 부생, 추출, 수전해 방식의 수소공급이 원활하지 않을 경우 해외 생산 비중이 당초 계획보다 증가될 수 있다. 따라서 국외 생산분에 대해 다양한 공급원의 확보가 필수적이며, 본 기술보고에서는 주요 공급후보국인 캐나다의 수소생산/수송 정책, 현황, 향후 전망에 대해 살펴보고 가장 현실적인 수소공급 방법으로 여겨지는 블루수소 프로젝트의 사례를 소개하고자 한다.

하수처리수를 이용한 소수력발전소 설계 및 성능예측 (Design and Performance Prediction of Small Hydropower Plant Using Treated Effluent in Wastewater Treatment Plant)

  • 이철형;박완순;김원경;김정연;채규정
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.78-83
    • /
    • 2013
  • A methodology to predict the output performance of small hydro power plant using treated effluent in waste water treatment plant has been studied. Existing waste water treatment plant located in Kyunggi-Do were selected and the output performance characteristics for these plants were analyzed. .Based on the models developed in this study, the hydrologic performance characteristics for SHP sites have been analyzed. The results show that the flow duration characteristics of small hydropower plant for waste water treatment plant have quite differences compared with small hydropower plant for the river. As a result, it was found that the developed model in this study can be used to analyze the output characteristics for small hydro power in waste water treatment plant. Additionally, primary design specifications such as design flowrate, capacity, operational rate and annual electricity production were estimated and discussed. It was found that the models developed in this study can be used to decide the design performance of small hydropower plant for waste water treatment plant effectively.

해양 조류발전단지 타당성 조사시 발전용량 산출방법에 관한 연구 (Study on Extractable power capacity of Tidal current power farm in the Feasibility investigation)

  • 조철희;김도엽;채광수;임진영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.169.1-169.1
    • /
    • 2010
  • Due to global warming, the need to secure an alternative resource has become the international issue. Not like other renewable energy sources, TCP is the high reliable and predictable and continuous energy source as the current pattern and speed can be predicted throughout the year. Having very strong tidal current speeds, there are many suitable site for the application of TCP (Tidal Current Power) on the west and south coastal region in Korea. The maximum current speed in the south is recorded up to 6.5m/s. Due to the high tidal current speed on the west coast of Korea, numerous tidal current projects are being planned. To extract a significant quantity of power, a tidal current farm with number of devices is required in the ocean. However, it is important to estimate the potential quantity of energy in the area. Also the realistic quantity that can be extracted is to be investigated. Based on the estimated energy production considering the number of devices and the interactional effects, system type, the water depth and etc., the cost of the development and the benefit from SMP can be estimated. The feasibility study for the 200MW tidal in Incheon, Korea has been performed recently. Based on the actual feasibility study, the procedure and the key points for the application of tidal current power farm are introduced in the paper.

  • PDF

리기다 소나무 인공조림지의 물질생산량에 관한 연구 (Distribution of Biomass and Production in Man-made Pitch Pine Plantation in Korea)

  • 임경빈;이경재;권태호;박인협
    • 임산에너지
    • /
    • 제2권2호
    • /
    • pp.1-12
    • /
    • 1982
  • To study tile comparison of aboveground biomass of Pinus rigida Mill. of 18-year-old, plantations located in Whaseong, Yuseong and Wanju district were selected. Ten sample trees in each district selected taking account of DBH distribution were felled carefully to minimize loss of branches and stem analysed by 1m lag segment sectioned from base . The tree height and DBH were measured for sample trees in total growing within $200m^2$ experimental plot. The diagram of oven-dry weight distribution of stem, branch and needle for each 1m segment was constructed. The logarithmic regression equations between dry weight of each component and the two variables, $DBH^2$ and tree height, combined term were presented. The standing crops in the sample stand was estimated to be as much as 23.88, 54.09 and 42.68 tons of dry matter, above ground , per ha in Whaseong, Yuseong anf Wanju district respectively. Annual net production was estimated at 253,657 and 3.65 tons per ha per year respectively. The net assimilation rate was 1.65,1.95 and 1.81 kg/kg/yr in Whaseong, Yuseong and Wanju district respectively. The efficency of leaf to produce stem was 0.99, 1.12 and 1.30 kg/kg/yr respectively.

  • PDF