• 제목/요약/키워드: anion-exchange resin

검색결과 144건 처리시간 0.032초

HPLC 형광검출법에 의한 Glyphosate의 혈중농도 측정 (Determination of Glyphosate in Whole Blood by HPLC-fluorescence Detection)

  • 이상기;김기욱;양자열;인상환;이수연
    • 약학회지
    • /
    • 제45권4호
    • /
    • pp.347-351
    • /
    • 2001
  • A rapid and sensitive method for the determination of glyphosate, a phosphated amino acid herbicide, in whole blood is presented. After removal of protein, the whale blood was purified by using the anion exchange resin (Dowex 1), and derivatized with 9-fluorenylmethyl chloroformate (FMCL). Derivatized glyphosate from blood sample was injected onto a Whatman partisil 10SAX column and separated with 0.1M phosphate buffer (pH 2.5) and acetonitrile (ratio=3:1). The high performance liquid chromatography-fluorescence detection gave the detection limit of 86pg and linearity of 0.9999 in the range of 0.25 $\mu$g/ml and 25 $\mu$g/ml. The recoveries of glyphosate added to the blood samples were ranged from 75.3% to 100.4% compared to the samples prepared in water. The derivatized glyphosate was stable at various acidity and temperature. This method has been successfully applied to the blood samples of lethal intoxication with the herbicide glyphosate.

  • PDF

목질계 바이오매스 가수분해물 중 발효저해 물질에 대한 생물학적 및 물리화학적 무독화 방법의 평가 (Evaluation of Biological and Physico-chemical Detoxification Methods for the Removal of Inhibitors in Lignocellulose Hydrolysate)

  • 조대행;김용환
    • KSBB Journal
    • /
    • 제24권5호
    • /
    • pp.415-419
    • /
    • 2009
  • 본 연구에서는 리그노셀룰로스 가수분해물과 유사한 조성을 갖는 합성 용액을 이용하여 무독화 실험을 진행하였다. 생물학적 무독화 방법으로는 peroxidase와 laccase와 같은 효소를 이용하였고, 이온교환과 흡착과 같은 물리화학적 방법으로는 이온교환수지와 활성탄을 이용하였다. 효소 중 peroxidase는 페놀계 화합물의 제거에 탁월한 효율을 보였으며, 5-HMF와 furfural은 활성탄에 의해 거의 모두 제거되었고, 아세트산은 음이온교환수지를 사용하는 것이 가장 효율적이었다. 활성탄과 이온교환수지는 다소간의 당손실을 일으켰다. 무독화 방법은 당화액에 포함되어 있는 저해물질의 조성을 고려하여 결정되어야 한다.

음(陰)이온교환수지(交換樹脂)를 이용한 Ammonium Metavanadate로부터 바나듐 흡탈착(吸脫着) 특성(特性) (Adsorption/Desorption Characteristics of Vanadium from Ammonium Metavanadate using Anion Exchange Resin)

  • 전종혁;김영훈;황인성;이진영;김준수;한춘
    • 자원리싸이클링
    • /
    • 제22권1호
    • /
    • pp.55-63
    • /
    • 2013
  • SCR 탈질 폐촉매 내에는 바나듐, 텅스텐 등 고가의 희유금속이 포함되어 있어 분리 및 회수가 필요하다. 본 연구에서는 바나듐 및 텅스텐 등의 희유금속을 함유하고 있는 SCR 탈질 폐촉매에서 바나듐을 회수하기 위하여 ammonium metavanadate를 사용하여 상용 음이온교환수지인 MP600에 의한 흡탈착실험을 실시하였다. 실험결과 초기 pH의 영향에 대해 pH 2 ~ 6에서 음이온화가 활발하여 높은 흡착율을 보였으며, 반응온도가 높아짐에 따라 흡착속도가 향상되는 경향을 보였으나 최대흡착량은 온도의 영향을 받지 않았다. 탈착에 대한 pH의 영향은 pH 1.0 이하의 강산성 및 pH 13.0 이상의 강염기성에서 높은 탈착율을 보였으나 pH 3.0 ~ 11.0 에서는 탈착율이 낮거나 거의 이루어지지 않았다. 흡착평형실험에 따른 흡착등온식은 Freundlich 흡착등온식에 적합하였으며, 반응 시간에 따른 흡착반응속도는 pseudo-second-order로 잘 모사되었다. 또한 Dubinin-Radushkevich, Temkin 흡착등온식을 통하여 흡착 에너지를 평가하였다.

이온교환수지를 이용한 농 ${\cdot}$ 어촌 지하수중의 질산이온 제거 (Nitrate Removal in Rural Groundwater Using Ion Exchange Resin)

  • 권순국;유명진;정태명;김민석
    • 한국환경농학회지
    • /
    • 제16권2호
    • /
    • pp.193-198
    • /
    • 1997
  • 본 연구에서 얻을 수 있었던 결과를 요약하면 다음과 같다. 1. 황산이온 농도를 포함해 원수의 음이온 농도가 낮은 경우 질산이온을 효율적으로 제거하기 위해 사용가능한 수지는 일반적으로 사용되는 Type 1수지보다도 공극형태가 gel 형태인 Type 2수지를 사용하는 것이 적절할 것으로 판단된다. 그러나 음이온 농도가 높은 지하수나 빠른 유속으로 처리할 경우 공극형태가 macroporous인 것이 유리할 것으로 판단된다. 또한 원수의 항산이온 농도가 낮은 경우에는 같은 macroporous 형태의 수지라도 IRA-900 같은 일반 형태의 수지가 질산이온 선택성 수지보다도 효율이 좋은 것으로 나타났다. 2. Type 2 수지를 사용하여 얻은 자료로 동력학적 접근 방정식에 적용하여 얻은 결과를 다중희귀분석한 결과 다음과 같은 식을 도출할 수 있었다. $logq_0$=-0.14logV-0.148logH-1.04(r=0.99) logM=0.135logV+0.151logH+1.814(r=0.99) 3. 황산이온 농도가 다소 높은 지하수를 처리할 때는 일반형태인 IRA-900보다도 질산이온 선택성 수지인 IMAC HP-555 수지가 효율이 좋은 것으로 나타나 원수의 황산이온 농도가 50mg/l 이상일 경우에는 질산이온 선택성 수지를 사용하는 것이 바람직할 것으로 판단된다.

  • PDF

$\textrm{N}_{G}$-Mon $o^{14}\textrm{C}$-methyl]-L-arginine의 합성 (Synthesis of $\textrm{N}_{G}$-Mon $o^{14}\textrm{C}$-methyl]-L-arginine)

  • 조영봉
    • Environmental Analysis Health and Toxicology
    • /
    • 제1권1호
    • /
    • pp.77-80
    • /
    • 1986
  • $N^{G}$ -Mono[$^{14}$ C-Methyl]-L-arginine을 방사선화학적 방법으로 mono [$^{14}$ C]-Methylamine 으로부터 합성한후 양이온 교환수지에 흡착시킨 다음 암모니아수로 용출시켜 정제하였으며 flavianic acid를 사용하여 결정상태로 얻었다. 한편 flavianate와 음이온 교환수지 를 함께 실온 이하의 온도에서 교반혼합함으로서 유리 상태의 amino acid를 쉽게 만들수 있으며 박층크로마토그라피, 박층전기영동 및 섬광분광분석법으로 순도를 조사하였다.

  • PDF

A Study on the Extraction and Purification of Glutathione from Yeast

  • Kim, Seong-Ung;Yang, Choong-Ik;Min, Shin-Hong;Rhee, Sang-Hi;Kim, Yong-Bae
    • Journal of Pharmaceutical Investigation
    • /
    • 제8권2호
    • /
    • pp.1-10
    • /
    • 1978
  • During the course of studies on the production of glutathione from yeast, process development and optimization was carried out. The optimal pH for the extraction of glutathione was found to be 2.5 to 4.0 and the maximum yield for glutathione was obtained when the extraction temperature was 25 to $45^{\circ}C$. The cuprous salt of glutathione was recovered maximally at the range of 2 to 4g of cuprous oxide per 10 Kg of compressed yeast. Further purification was needed for the removal of impurities from glutathione. Cation exchange resin, anion exchange resin and Sephadex G-25 were employed for this purpose. 13 to 15 g of glutathione was obtained from 10 Kg of compressed yeast and the purity was above 99.3%.

  • PDF

산림토양내(山林土壤內) 질소(窒素)의 양료화(養料化)와 질산화(窒酸化)에 관(關)한 연구(硏究) : ion 교환수지(交換樹指)의 처리(處理) 방법(方法)에 따른 질소(窒素)의 흡수율(吸收率) 변화(變化) (N Mineralization and Nitrification in Forest Soils : Effect of Chemical Treatment on N Adsorption by Ion Exchange Resin)

  • 이천용
    • 한국산림과학회지
    • /
    • 제79권3호
    • /
    • pp.285-289
    • /
    • 1990
  • 산림토양내(山林土壤內) N 양료화(養料化)와 질산화(窒酸化)를 구명(究明)하기 위하여 최근(最近) 많이 사용하고 있는 ion 교환 (交換) 수지(樹脂) (Ion Exchange Resin : IER)의 방법(方法)을 구명(究明)하고 실험실(實驗室)과 토양(土壤)에 묻었던 IER의 재사용(再使用) 여부를 판단(判斷)하기 위하여 흡수율(吸收率)을 분석(分析)하였다. IER 20g을 나이론 스타킹에 넣고 무처리구, 2M NaCl에 진탕한 후 물에 씻은 처리구(處理區)(2M NaCl구(區), 4M NaCl에 진탕한 처리구(處理區)로서 N 흡수율(吸收率)을 분석(分析)한 결과(結果) 2M NaCl구(區)의 IER은 $NH_4$$NO_3$를 각각(各各) 70, 60% 흡수(吸收)하여 가장 높은 결과를 보였고 4M NaCl구(區)는 40%정도의 흡수율(吸收率)을 나타냈다. 무처리(無處理) IER은 $NO_3$ 흡수율에서 2M NaCl구(區)와 비슷하였으나 $NH_4$는 낮은 N 농도에서 과대치를 나타냈다. 재사용(再使用)한 IER의 흡수율은 60~80%로서 일정한 흡수율을 나타내지 않았지만 전처리(前處理)로서, 흡수율(吸收率)을 구명(究明)하여 N 농도별로 각각(各各) 흡수율(吸收率)을 적용하면 재사용이 가능할 것으로 판단(判斷)된다.

  • PDF

킬레이트 시약으로 처리한 음이온 교환수지에 의한 금속이온의 선택적 흡착에 관한 연구 (A Study of Selective Absorption of Metal Ions by Chelating Agent-Loaded Anion Exchange Resins)

  • 이대운;이원;유의경
    • 대한화학회지
    • /
    • 제23권3호
    • /
    • pp.141-151
    • /
    • 1979
  • 전형적인 음이온 교환수지인 Dowex 1-X8 (50∼100메쉬)에 술폰기를 갖는 킬레이트 시약인 8-hydroxyquinoline-5-sulfonic acid (HQS)와 7-nitroso-8-hydroxyquinoline-5-sulfonic acid (NHQS)를 흡착시킨 킬레이트 수지를 사용하여 수용액에 용해되어 있는 Fe(Ⅲ), Cu(Ⅱ), Pb(Ⅱ) 및 Zn(Ⅱ)을 흡착시켜 다른 이온들로부터 분리시키는 연구를 시도한다. 킬레이트 수지의 안정성은 수용액에 공존하는 음이온의 종류, 그 농도 및 액성에 따라 영향을 받으므로 수지사용의 최적조건을 결정하였으며, 수지에 대한 두 킬레이트 시약의 흡착성도 정성적으로 해석하였다. 금속이온의 흡착은 킬레이트 수지에 있는 HWS 및 NHQS와 각 금속이온과의 킬레이트 형성에 의한 것으로 그 흡착력은 각 킬레이트의 안정도상수값과 비례한다. 액성이 PH3∼4 범위에서 HQS-수지의 금속이온의 흡착능은 Fe(Ⅲ):0.63, Cu(Ⅱ):0.82 및 Pb(Ⅱ):0.79 mmol/g이며, NHQS-수지의 경우는 Cu(Ⅱ):1.07 및 Pb(Ⅱ):0.96mmol/g이다. 몇가지 금속이온의 혼합액을 시료로 하여 분리를 시도했다.

  • PDF

모의 사용후분산핵연료($U_3Si/Al$) 용해용액으로부터 네오디뮴 분리에 관한 연구 (A Study on the Separation of Neodymium from the Simulated Solution of $U_3Si/Al$ Spent Nuclear Fuel)

  • 최광순;김정석;한선호;박순달;박영재;조기수;김원호
    • 분석과학
    • /
    • 제13권5호
    • /
    • pp.584-591
    • /
    • 2000
  • 2단계 음이온교환분리를 이용하여 모의 사용후분산핵연료($U_3Si/Al$)용해용액으로부터 Nd을 분리하기 위한 연구를 수행하였다. 사용후분산핵연료를 모사하기 위하여 사용전핵연료($U_3Si/Al$)를 4 M HCl과 10 M $HNO_3$의 혼산으로 녹인 다음, 8 또는 15종의 핵분열생성원소를 첨가하였다. 용액 중 미량의 실리카는 플루오르화수소산을 넣고 가열하여 제거하였으며, U은 1차 음이온교환수지에 흡착시켜 제거하였다. Nd은 2차 음이온교환수지상에서 여러 핵분열생성원소들로부터 질산-메틸알콜 매질의 용리액으로 분리하였다. 과량의 Al은 Nd의 용리속도에 크게 영향을 미치지 않았으나, Nd을 포함한 Al, Eu, Gd, Sm 및 Sr의 절대 용리양을 감소시켰다. Nd을 용리액[0.04 M $HNO_3$-99.8% MeOH(1:9)]으로 용리하기 전에 과량의 Al은 부하(loading) 용액(0.8 M $HNO_3$/99.8% MeOH) 3 mL로 사전 용출시켜 제거하였다. 용리된 Nd의 회수을은 Al의 양에 관계없이 94% 이상이었다. 순수한 Nd을 분리하기 위해서는 9-13 mL 부분의 용리액을 취하는 것이 효과적이었다.

  • PDF

음이온교환수지에 의한 모나자이트 중 희토류원소의 분리 (제2보) (Separation of Rare Earth Elements in Monazite Sand by Anion Exchange Resin (Ⅱ))

  • 차기원;이종해;윤석호;하영구
    • 대한화학회지
    • /
    • 제24권6호
    • /
    • pp.452-456
    • /
    • 1980
  • 용리액의 pH와 EDTA 농도변화에 따른 모나자이트 중의 희토류원소의 분리에 이어 수지통의 크기, 유츌속도 수지종류에 따른 분리를 약 10g 의 희토류를 흡착시킨 후 연구하였다. 같은 무게의 수지에서는 수지통의 높이가 높은 것이 낮은 것보다 분리도가 좋았고, 전 희토류를 용리하는데 필요한 용리액의 부피는 비슷하였다. 용리액의 유출속도를 1ml/min에서 2ml/min으로 증가시킨 결과 전 희토류를 완전히 용리시키는데 필요한 용리액의 부피가 10l 더 필요했고 분리도는 1ml/min일때 보다 나빴다. 그러나 용리시키는데 걸리는 시간은 약 6일 단축되었다. 수지의 입자가 25∼50 mesh의 Ambellite IR A-400의 수지를 이용하여 분리한 결과는 Dowex 1(50∼100 mesh)의 수지를 사용하여 분리한 결과보다 못하였다.

  • PDF