• Title/Summary/Keyword: animal gait analysis

Search Result 11, Processing Time 0.025 seconds

Compensatory Change of a Dog with Glenoid Dysplasia in Kinetic Gait Analysis before and after Reconstruction of Medial Patellar Luxation (Case report) (관절오목 이형성이 있는 개의 내측 슬개골 탈구 수술 전, 후의 운동역학적 보상적 보행 변화 (증례보고))

  • Shinho Lee;Jeonghyun Seo;Yuri Cha
    • Journal of Korean Physical Therapy Science
    • /
    • v.31 no.1
    • /
    • pp.46-52
    • /
    • 2024
  • Background: This study aims to investigate compensatory strategy in a dog with glenoid dysplasia using kinetic gait analysis before and after reconstruction of medial patellar luxation. Design: Case report Method: On the platform, gait analysis was evaluated for a dog with congenital luxation and bilateral medial patellar luxation (MPL). A dog was evaluated for maximal vertical force (MVF), body load distribution (BLD), and symmetry index (SI), including the left forelimb with congenital luxation before MPL surgery, 15 days of surgery, and 40 days of surgery. Result:: In the comparison between the preoperative and the 15 days of surgery, the MVF of the bilateral forelimbs, especially in the non-affected forelimbs, increased, and the SI also increased. For BLD, the maximum load distribution increased, but the total load distribution decreased. In the comparison of 15 days and 40 days of surgery, MVF and BLD increased, and SI decreased on 40days of surgery. Conclusions: In a dog, the shift in weight load to the non-affected side occurs all the limbs, affecting the peak vertical force, weight load distribution, and symmetry index.

Effects of therapeutic horse-riding program on the walking ability of students with intellectual disabilities

  • Kang, Ok-Deuk
    • Journal of Animal Science and Technology
    • /
    • v.63 no.2
    • /
    • pp.440-452
    • /
    • 2021
  • The purpose of this study was to determine if an 8-week therapeutic riding (TR) program was effective in improving the walking ability of students with intellectual disabilities. Thirteen students diagnosed with intellectual disabilities participated in the TR program. TR sessions were conducted twice a week (30 min per session), with a total of 16 rides taking place over an 8-week period. A gait measurement analyzer was used to measure progress based on a turn test (6-m walking and turning test), walk test (10-m walking), and timed up and go (TUG) test. Measurements were made three times: before horse-riding (P0), after 4 weeks (8 rides) of horse-riding (P1), and after 8 weeks (16 rides) of horse-riding (P2). Data analysis was conducted using SPSS software (ver. 22.0). Descriptive statistics were generated on the general characteristics of the subjects, and the Kolmogorov-Smirnov test was used to verify the normality of the data. Because of the lack of normality, the data were analyzed using a nonparametric method and the significance level was set to 0.05. Measurements of the duration of the forward gait cycle (s) in the turn test and the forward gait speed (m/s) in the walk test indicated improved walking ability after the TR program (p < 0.001); the stride length (% height) also increased significantly (p < 0.05). The walk test revealed a significant effect of the program on the duration of the forward gait cycle (p < 0.05), while there were significant improvements on the left and right of the elaborated strides (p < 0.001). No significant improvement in TUG test performance was observed after the TR program. In this study, an 8-week TR program had positive results on gait. Therefore, further research is merited, where TR programs are likely to improve the walking ability of individuals with intellectual disabilities.

Kinetic gait analysis in a small sized dog with congenital shoulder luxation (소형견의 선천성 어깨관절 탈구에 관한 운동역학적 보행 분석)

  • ShinHo Lee;Chung Hui Kim;Jae-Hyeon Cho
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.2
    • /
    • pp.175-179
    • /
    • 2023
  • This study was conducted to find out the compensation strategy through kinetic gait analysis by comparing dog with congenital luxation of the shoulder joint and normal dog. Ground reaction forces were recorded for all limbs while normal poodle dog and poodle dog with shoulder joint luxation was allowed to walk on an instrumented platform. The dogs were evaluated for maximal vertical force (MVF), body load distribution (BLD), and symmetry index (SI). The MVF was increased in the contralateral forelimb of luxated shoulder joint. The SI was also increased in a dog with dislocated shoulder joints in the forelimbs. For BLD, the maximum load distribution increased centrally, but the total load distribution decreased in the ipsilateral forelimb paw. In contrast, total load distribution was increased in the contralateral forelimb paw. During forelimb lameness, changes in weight-bearing load showed compensatory load redistribution. These biomechanical changes may lead to changes in the musculoskeletal system in a dog with luxated shoulder.

Clinical animal test for development of osseointegration implant;application for beagle tibia (골융합 임플란트 개발을 위한 동물임상실험;비글견 경골 적용)

  • Choi, Kyong-Joo;Kim, Shin-Ki;Mun, Mu-Seong;An, Jae-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1373-1377
    • /
    • 2003
  • Current prostheses for amputees are generally extrinsic wearing socket type that the coupling between body stump and appliance wraps the soft tissue and this structure causes several problems :applying direct weight to soft tissue such as skin and muscle, skin trouble of contacting area and pain. In this study, osseointegration implant is a method to directly connect prosthesis to the residual stump skeletal tissue of arm, finger and leg through surgical operation. Technology presented in this paper essentially solves the problems of pain and abnormal weight transfer system indicated above and recovers the functions of the amputated arm and leg. In this paper, implant shape was designed for the first step for the development of osseointegration implant and then we studied the possibility to apply this osseointegration implant to human body by performing implant insertion operation to beagle tibia for the clinical animal test and normal beagle's gait analysis was executed in order to quantitatively verify the beagle's skeletal functions after the implant insertion.

  • PDF

Imaging Diagnosis of Sacrocaudal Dysgenesis in a Shih-tzu Dog

  • Choi, Soo-Young;Lee, In;Cho, Na-Young;Shin, Bong-Hun;Lee, Ki-Ja;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.33 no.6
    • /
    • pp.389-391
    • /
    • 2016
  • A 10-month-old, intact female Shih-tzu dog with a pelvic limb ataxic gait, and urinary and fecal incontinence since birth, was examined by computed tomography and magnetic resonance imaging. The butterfly hemivertebra of the fourth lumbar vertebra, agenesis of the third sacral and coccygeal vertebrae, and spina bifida of the remaining sacral vertebra were observed on the computed tomography images. Magnetic resonance imaging revealed traction of the conus medullaris. The dog was diagnosed with sacrocaudal dysgenesis with presumptive tethered cord syndrome, and concurrent infectious cystitis was found by ultrasonography and urinary analysis. The Shih-tzu recovered from the cystitis, but still has the ataxic gait and urinary and fecal incontinence. This report summarizes the case of a dog with sacrocaudal dysgenesis that was identified by imaging diagnosis.

Efficacy of carprofen administration and rehabilitative intervention in a dog with unilateral forelimb lameness (편측 앞다리 파행이 있는 개에서 카프로펜 투여와 재활 중재의 효과)

  • Shin-Ho Lee;Sujin Kim;Jae-Hyeon Cho
    • Korean Journal of Veterinary Service
    • /
    • v.47 no.3
    • /
    • pp.185-191
    • /
    • 2024
  • This case report examines the efficacy of carprofen and rehabilitation therapy in a 7-year-old, 4.5 kg, spayed Poodle with unilateral forelimb lameness. Gait analysis assessed kinetic parameters such as peak vertical force (PVF), vertical impulse (VI), symmetry index (SI), and body load distribution (BLD) before and after treatment. The differences between the left and right forelimbs were recorded. Before intervention, the PVF differences between the forelimbs were -4.00% during walking and 40.00% during trotting. Two weeks post-intervention, these improved to 8.33% and 27.67%, further reducing to 6.33% and 18.00% after four weeks. VI differences also improved, with initial values of -0.67 N∙s during walking and -1.3 N∙s during trotting decreasing to -0.03 N∙s and -0.87 N∙s, respectively. SI increased from 6.23% to 11.87% during walking, while it decreased from 33.63% to 14.73% during trotting. BLD differences reduced from -1.17 cm2 and -7.13 cm2 to 0.23 cm2 and -2.17 cm2, respectively, after four weeks. These results suggest that a combination of carprofen administration and rehabilitative intervention can effectively reduce lameness and improve symmetry in dogs with unilateral forelimb lameness, as evidenced by improvements in key gait parameters over the treatment period.

Relationships among bedding materials, bedding bacterial composition and lameness in dairy cows

  • Li, Han;Wang, Xiangming;Wu, Yan;Zhang, Dingran;Xu, Hongyang;Xu, Hongrun;Xing, Xiaoguang;Qi, Zhili
    • Animal Bioscience
    • /
    • v.34 no.9
    • /
    • pp.1559-1568
    • /
    • 2021
  • Objective: Bedding materials directly contact hooves of dairy cows and they may serve as environmental sources of lameness-associated pathogen. However, the specific composition of bacteria hidden in bedding materials is still not clear. The aim of this study was to determine the effect bedding material and its bacterial composition has on lameness of Holstein heifers. Methods: Forty-eight Holstein heifers with similar body weights were randomly assigned into three groups including sand bedding (SB), concrete floor (CF), and compost bedding (CB). Hock injuries severity and gait performance of dairy cows were scored individually once a week. Blood samples were collected at the end of the experiment and bedding material samples were collected once a week for Illumina sequencing. Results: The CF increased visible hock injuries severity and serum biomarkers of joint damage in comparison to SB and CB groups. Besides, Illumina sequencing and analysis showed that the bacterial community of CB samples had higher similarity to that of SB samples than CF samples. Bacteria in three bedding materials were dominated by gastrointestinal bacteria and organic matter-degrading bacteria, such as Actinobacteria, Firmicutes, and norank JG30-KF-cM45. Lameness-associated Spirochaetaceae and Treponeme were only detected in SB and CB samples with a very low relative abundance (0% to 0.08%). Conclusion: The bacterial communities differed among bedding materials. However, the treponemes pathogens involved in the pathogenesis of lameness may not be a part of microbiota in bedding materials of dairy cows.

Parameters for Min. Time and Optimal Control of Four-Legged Mobile Robot (4-족 이동로보트의 최소시간 최적제어를 위한 파라메터 연구)

  • 박성호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.490-496
    • /
    • 1995
  • A four-legged mobile robot can move on the plain terrain with mobility and stability, but if there exist any obstacles on the terrain of the motion direction, it takes extra times for a mobile robot to cross those obstacles and the stability should be considered during motion. The main objevtive is the study of a quadruped which can cross obstacles with better mobility, stability and fuel economy than any other wheeled or tracked vehicles. Vertical step, isolated wall and ditch are the basic obstacles and by understanding those three cases perfectly, a quadruped can move on any mixed rough terrain as 4-legged animal moves. Each leg of a determine the crossing capability in a static analysis. A quadruped can be simplified with links and joints. By applying the research method, a quadruped can determine the control procedures as soon as it receives the terrain informations from scanner and finally can be moved as animals move with mobility and stability.

  • PDF

Development of the Osseo-integrated Implant system for Laboratory Animals (동물실험용 골융합 임플란트 시스템 개발)

  • Bae, Tae-Soo;Heo, Hyun;Kim, Shin-Ki;Mun, Mu-Seong;Ahn, Jae-Yong;Hong, Sung-Ran
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.10
    • /
    • pp.117-122
    • /
    • 2007
  • The novel implant system was developed using osseo-integration technology which enable amputee to overcome skin troubles in use of previous socket system and was evaluated in view of biomechanics, radiology, histology, and pathology. The osseo-integrated implants were designed and manufactured using CT image of canine's tibia and were applied to laboratory animals (canines). The follow-up studies were performed for 24 months with 10 canines. In radiology examination, we found that the relative low strain distribution caused medial and posterior bone resorption and then we verified them by biomechanical testing. In histological approach, the complete osseo-integration was observed through the activity of osteoblast cells around bone-implant interface and the radial outer region of bone due to peristeum reaction. Lastly in pathological aspect, the evidence of superficial infection was detected but that of deep infection was not. Therefore it is thought that infection problem will be overcome by immunity of body and good hygiene.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF