• Title/Summary/Keyword: angular position

Search Result 445, Processing Time 0.024 seconds

Study of Speed Profile for Dynamic Stability of EOTS (EOTS의 동적 안정성을 위한 속도 프로파일에 대한 연구)

  • Gyu-Chan Lee;Dong-Gi Kwag
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.919-925
    • /
    • 2023
  • Modern drones are equipped with miniaturized mission equipment capable of performing various tasks such as surveillance and reconnaissance. Consequently, these mission equipment are exposed to disturbances like wind loads and motor rotations, which can lead to instability in the operation of the Electro-Optical Targeting System (EOTS). Specifically, simple step inputs for changing the line of sight in EOTS can cause abrupt changes in speed, inducing overshoot and potentially creating instability along with other disturbances. To address this, a velocity profile was designed so that the angular velocity moves in a trapezoidal shape when changing the EOTS line of sight. A Double-loop controller was designed to apply this profile as an input to the external loop receiving position feedback. The system's stability was then compared, and the velocity profile was optimized within a stable range by varying maximum speed and acceleration.

Computer Interface for the Disabled Using Gyro-sensors and Artificial Neural Network (자이로 센서와 인공신경망을 이용한 장애인용 컴퓨터)

  • 안용식;엄광문;김철승;허지운;나유진
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.411-419
    • /
    • 2003
  • This paper aims at developing 'gyro-mouse' which provides decent and comfortable human-computer interface that supports the usage of such software as an internet-browser in PC for the people paralyzed in upper limbs. This interface operates on information collected from head movement to get the cursor control. The interface is composed of two modules. One is hardware module in which the head horizontal and vertical angular velocities are detected and transmitted into PC. The other is a PC software that translates the received data into movement and click signals of the mouse. The ANN (artificial neural network) learns the quick nodding pattern of each user as click input so that it can provide user-friendly interface. The performance of the system was evaluated by three indices that are click recognition rate. error in cursor position control. and click rate of the moving target box. The performance result of the gyro-mouse was compared with that of the optical-mouse to assess the efficiency of the gyro-mouse. The average click recognition rate was 93%, average error in cursor position control was 1.4∼5 times of optical mouse. and the click rate with 50 pixels target box was 40%(30 clicks/min) to that of optical mouse. The click rate increased monotonously with the number of trial from 35% to 44%. The suggested system is expected to provide a new possibility to communicate with the society.

CEPHALOMETRIC NORMS OF THE HARD TISSUES OF KOREAN FOR ORTHOGNATHIC SURGERY (악교정 수술을 위한 한국 성인 정상교합자의 경조직 기준치)

  • Kim, Kyung-Ho;Choy, Kwang-Chul;Kim, Hyoung-Gon;Park, Kwang-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.221-230
    • /
    • 2001
  • This study was performed to evaluate hard tissue cephalometric norms for Korean adults which can be implemented in surgical orthodontic treatment planning using selected horizontal reference plane especially for Koreans (Male: $SN-7.5^{\circ}$, Female: $SN-9.0^{\circ}$) and a simplified analytical method. 70 males and 70 females consisting of freshmen of Yonsei University from 1996 to 1997 and students from the Dental College of Yonsei University were chosen according to clinical examination and cephalometric analysis. The samples had normal profiles, normal anteroposterior skeletal relationship(ANB angle of $0^{\circ}$ to $4^{\circ}$ and Wits appraisal of -4.0mm to 0mm), and Class I molar and canine relationship. They had no missing or supernumerary teeth and had no experience of orthodontic or prosthetic treatment. After the selection of 23 landmarks and the construction of horizontal and vertical reference lines, 22 skeletal and 12 dental measurements were taken. These consisted of vertical and horizontal linear measurements and angular measurements. The results were as follows. 1. Mean and standard deviation of the measurements were calculated for males and females. 2. Most of the skeletal vertical measurements, and maxillary and mandibular length were bigger in males than females. Whereas anterior facial height ratio(N-ANS/ANS-Me) as well as maxillary and mandibular antero-posterior position in relation to the vertical reference line(N-perpendicular) showed no signigicant difference between sexes. 3. Maxillary and mandibular dental antero-posterior position in relation to the vertical reference line(N-perpendicular) showed no significant difference between sexes. 4. The upper incisor show(U1-Stms) was $2.1{\pm}1.7mm$ in males and $3.3{\pm}1.7mm$ in females. In this study, hard tissue cephalometric norms of Korean adults for orthognathic surgery were obtained.

  • PDF

ACQUISITION OF THE FLIGHT INFORMATION USING THE KSR-3 MAGNETOMETER (KSR-3 탑재 자력계를 이용한 비행정보 획득 연구)

  • Kim, Sun-Mi;Jang, Min-Hwan;Lee, Dong-Hun;Han, Young-Seok;Kim, Jun;Hwang, Seung-Hyun;Lee, Eun-Seok;Lee, Sun-Min;Kim, Hyo-Jin;Lee, Su-Jin
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.1
    • /
    • pp.29-42
    • /
    • 2003
  • The KSR-3 magnetometers consist of the fluxgate magnetometer (MAG/AIM) for acquiring the rocket flight attitude information, and the search-coil magnetometer (MAG/SIM) for the observation of the Earth's magnetic fluctuations. The position (latitude, longitude, and height) and flight condition (the transformation angle) of the rocket is measured after the data based on these two magnetometers are compared with IGRF The gap in the vector of magnetic field between the position of the launching point and an impact point is taken into account in data reduction. Angular variation of pitch, yaw, and roll can be researched when the data is applied to the coordinate system of the rocket.

A comparative study of pre- and post-treatment cephalometric measurements: Upper premolar extraction only vs. upper/lower premolar extraction groups (상악 편악 소구치발치와 양악 소구치발치에 의한 교정치료 전후의 측모 두부방사선계측법적 비교 연구)

  • Kim, Young-Seok;Kim, Su-Jung;Kang, Seung-Goo;Lee, Young-Jun
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.421-431
    • /
    • 2007
  • The objective of this study was to provide guidelines for the diagnosis and successful treatment of orthodontic treatment with upper premolar extraction only Methods: The sample group consisted of 40 patients (20 with upper premolar extraction only, 20 with both upper and lower premolar extractions) who showed an overjet of more than 7 mm and were finished successfully. Lateral cephalographs were taken before and after orthodontic treatment. Landmarks showing the position of the upper and lower incisors and the position of the upper and lower lip were determined and angular measurement of these values were obtained for statistical analysis (Mann-Whitney test). Results: At pre-treatment, the position of the lower incisor was less labially inclined and the convexity of the lower lip was smaller in the upper premolar extraction only group than in the upper/lower premolar extraction group. At post-treatment, there was no difference in all measurements except for the position of the lower incisor. A comparison of changes between pre- and post-treatment showed that the retraction of upper & lower incisors and the decrease in convexity of the lower lip were greater in the upper/lower premolar extraction group. Conclusions: Treatment by upper premolar extraction can be of benefit for patients whose lower incisor proclination and lower lip protrusion are not excessive.

A Study on the Neutron in Radiation Treatment System and Related Facility (방사선치료 장치 및 관련시설에서의 산란 중성자에 관한 연구)

  • Kim Dae-Sup;Kim Jeong-Man;Lee Hee-Seok;Lim Ra-Seung;Kim You-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.141-145
    • /
    • 2005
  • Purpose : It is known that the neutron is generally generated from the photon, its energy is larger than 10 MV. The neutron is leaked in the container inspection system installed at the customs though its energy is below 9 MV. It is needed that the spacial effect of the neutrons released from radiation treatment machine, linac, installed in the medical canter. Materials and Methods : The medical linear accelerator(Clinac 1800, varian, USA) was used in the experiment. Measuring neutron was used bubble detector(Bubble detector, BDPND type, BTI, Canada) which was created bubble by neutron. The bubble detector is located on the medical linear accelerator outskirt in three different distance, 30, 50, 120 cm and upper, lower four point from the iso-center. In addition, for effect on protect material we have measured eight points which are 50 cm distance from iso-center. The SAD(source-axis-distance), distance from photon source to iso-center, is adjusted to 100 cm and the field size is adjusted to $15{\times}15cm^2$. Irradiate 20 MU and calculate the dose rate in mrem/MU by measuring the number of bubble. Results : The neutron is more detected at 5 position in 30, 50 cm, 7 position in 120 cm and with wedge, and 2 position without mount. Conclusion : Though detection position is laid in the same distance in neutron measurement, the different value is shown in measuring results. Also, neutron dose is affected by the additional structure, the different value is obtained in each measurement positions. So, it is needed to measure and evaluate the neutron dose in the whole space considering the effect of the distance, angular distribution and additional structure.

  • PDF

Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring (파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측)

  • Kim, Young-Su;Park, Jin Hyung;Cho, Hwa Youn;Kim, Jae Hyeon;Kwon, Heungrok;Seo, Hee;Park, Se-Hwan;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Compton cameras overcome several limitations of conventional mechanical collimation based gamma imaging devices, such as pin-hole imaging devices, due to its electronic collimation based on coincidence logic. Especially large-scale Compton camera has wide field of view and high imaging sensitivity. Those merits suggest that a large-scale Compton camera might be applicable to monitoring nuclear materials in large facilities without necessity of portability. To that end, our research group have made an effort to design a large-scale Compton camera for safeguard application. Energy resolution or position resolution of large-area detectors vary with configuration style of the detectors. Those performances directly affect the image quality of the large-scale Compton camera. In the present study, a series of Geant4 Monte Carlo simulations were performed in order to examine the effect of those detector parameters. Performance of the designed large-scale Compton camera was also estimated for various monitoring condition with realistic modeling. The conclusion of the present study indicates that the energy resolution of the component detector is the limiting factor of imaging resolution rather than the position resolution. Also, the designed large-scale Compton camera provides the 16.3 cm image resolution in full width at half maximum (angular resolution: $9.26^{\circ}$) for the depleted uranium source considered in this study located at the 1 m from the system when the component detectors have 10% energy resolution and 7 mm position resolution.

Aesthetics of Samjae and Inequilateral Triangle Found in Ancient Triad of Buddha Carved on Rock - Centering on Formative Characteristics of Triad of Buddha Carved on Rock in Seosan - (고대(古代) 마애삼존불(磨崖三尊佛)에서 찾는 삼재(三才)와 부등변삼각(不等邊三角)의 미학(美學) - 서산마애삼존불의 형식미를 중심으로 -)

  • Rho, Jae-Hyun;Lee, Kyu-Wan;Jang, Il-Young;Goh, Yeo-Bin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.3
    • /
    • pp.72-84
    • /
    • 2010
  • This study was attempted in order to offer basic data for implementing and applying Samjonseokjo(三尊石造), which is one of traditional stone construction method, by confirming how the constructive principle is expressed such as proportional beauty, which is contained in the modeling of Triad of Buddha Carved on Rock that was formed in the period of the Three States, centering on Triad of Buddha Carved on Rock in Susan. The summarized findings are as follows. 1. As a result of analyzing size and proportion of totally 17 of Triad of Buddha Carved on Rock, the average total height in Bonjonbul(本尊佛) was 2.96m. Right Hyeopsi(右挾侍) was 2.19m. Left Hyeopsi(左挾侍) was 2.16m. The height ratio according to this was 100:75:75, thereby having shown the relationship of left-right symmetrical balance. The area ratio in left-right Hyeopsi was 13.4:13.7, thereby the two area having been evenly matched. 2. The Triad of Buddha Carved on Rock in Seosan is carved on Inam(印岩) rock after crossing over Sambulgyo bridge of the Yonghyeon valley. Left direction was measured with $S47^{\circ}E$ in an angle of direction. This is judged to target an image change and an aesthetic sense in a Buddhist statue according to direction of sunlight while blocking worshipers' dazzling. 3. As for iconic characteristics of Buddha Carved on Rock in Seosan, there is even Hyeopsi in Bangasang(半跏像) and Bongjiboju(捧持寶珠) type Bosangipsang. In the face of Samjon composition in left-right asymmetry, the unification is indicated while the same line and shape are repeated. Thus, the stably visual balance is being shown. 4. In case of Triad of Buddha Carved on Rock in Seosan, total height in Bonjonbul, left Hyeopsi, and right Hyeopsi was 2.80m, 1.66m, and 1.70m, respectively. Height ratio in left-right Hyeopsibul was 0.60:0.62, thereby having been almost equal. On the other hand, the area ratio was 28.8:25.2, thereby having shown bigger difference. The area ratio on a plane was grasped to come closer to Samjae aesthetic proportion. 5. The axial angle of centering on Gwangbae was 84:46:50, thereby having been close to right angle. On the other hand, the axial angle ratio of centering on Yeonhwajwa(蓮華坐: lotus position) was measured to be 135:25:20, thereby having shown the form of inequilateral triangle close to obtuse angle. Accordingly, the upper part and the lower part of Triad of Buddha Carved on Rock in Susan are taking the stably proportional sense in the middle of maintaining the corresponding relationship through angular proportion of inequilateral triangle in right angle and obtuse angle. 6. The distance ratio in the upper half was 0.51:0.36:0.38. On the other hand, the distance ratio in the lower half was 0.53 : 0.33 : 0.27. Thus, the up-down and left-right symmetrical balance is being formed while showing the image closer to inequilateral triangle. 7. As a result of examining relationship of Samjae-mi(三才美) targeting Triad of Buddha Carved on Rock in Susan, the angular ratio was shown to be more notable that forms the area ratio or triangular form rather than length ratio. The inequilateral triangle, which is formed centering on Gwangbae(光背) in the upper part and Yeonhwajwa(lotus position) in the lower part, is becoming very importantly internal motive of doubling the constructive beauty among Samjae, no less than the mutually height and area ratio in Samjonbul.

Three-dimensional finite element analysis of the bracket positioning plane in lingual orthodontics (설측 브라켓 부착을 위한 기준평면 설정에 관한 3차원 유한요소법적 연구)

  • Kim, Sun-Hwa;Park, Soo-Byung;Yang, Hoon-Chul
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.30-44
    • /
    • 2006
  • This study was performed to investigate the location of the ideal bracket positioning plane in lingual orthodontics using the three-dimensional finite element method. Displacement of the anterior teeth were evaluated according to the vertical and the angular movements of the bracket positioning plane. To achieve the ideal movement of anterior teeth in the lingual central plane, the location of the force application point and the amount of the moment applied to the four incisors were evaluated. As the bracket positioning plane was moved parallel toward the incisal edge, uncontrolled tipping and extrusion of the maxillary and the mandibular incisors were increased. But lingual tipping of the crown was decreased in the maxillary and the mandibular canines. As the bracket positioning plane was inclined toward the incisal edge, lingual tipping was increased in the 6 anterior teeth and extrusion of incisors and intrusion of the canine was also increased. As the retraction hook of the canine bracket was elongated, lingual tipping and extrusion of the central incisor and mesial movement and extrusion of the lateral incisor were increased. In the canine, mesial and labial movements of the crown were increased. When the moment was applied to the 4 incisors of the maxillary and the mandibular arch in the lingual central plane, 280 gf-mm in the maxillary central incisor, 500 gf-mm in the maxillary lateral incisor, 170 gf-mm in the mandibular central incisor and 370 gf-mm in the mandibular lateral incisor produced bodily movement of the individual tooth.

A Study on the Torque Characteristics Depending on the Elastic Body Materials of a Hexadecagon Shaped Ultrasonic Motor (탄성체 재질 변화에 따른 16각형 초음파모터의 토크 특성 연구)

  • Cheon, Seong-Kyu;Jeong, Seong-Su;Lee, Byung-Ha;Ha, Yong-Woo;Kim, Myong-Ho;Park, Tae-Gone
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.5
    • /
    • pp.286-291
    • /
    • 2014
  • In this study, novel ultrasonic rotary motor of hexadecagon shape stator was proposed. Stator of the hexadecagon ultrasonic motor was composed of an elastic ring and ceramics. The elastic ring had sixteen sides and sixteen angular points. Eight ceramics were attached on the outer surface of the eight sides of the ring. When rotor of cylindrical shaft was inserted inside of the ring stator, central lines of the sixteen sides of the stator hold the shaft by the slight pressures(frictions). This slight pressure was a preload of the motor and it could be controlled by radius and thickness of the ring. When two sinusoidal voltages which have 90 degree phase difference were applied to each four ceramics, elliptical displacements of inner surface of the ring were obtained. These elliptical displacements of the inner surface rotated the shaft rotor through the frictions. The proposed hexadecagon ultrasonic motor was designed and analyzed by using the finite element method (FEM), depending on materials of the elastic ring. Based on the FEM results, one model of motor which showed maximum displacement at contact points was chosen and fabricated. And characteristics of the motor were compared with simulated results. When the motor was fabricated with these results, EL20ET0.5CT0.5CW2 model showed 115[rpm] speed about input voltage of 60[Vrms] at 65.6[kHz]. And the maximum torque of 6[gfcm] was obtained. From these results, the hexadecagon shaped ultrasonic motor can be used to actuator for optical device which needs detailed position control. Also it can be used to medical and portable device by reducing size and weight.