• Title/Summary/Keyword: angle-only data

Search Result 337, Processing Time 0.029 seconds

Rapid Prototyping of Head-of-Bed Angle Measurement System using Open-Source Hardware (오픈소스하드웨어를 이용한 침상머리각도 측정 시스템의 래피드 프로토타이핑)

  • Jo, Bong-Un;Park, Yeong-Sang;Seo, Sugkil;Kim, Jin-Geol;Lee, Young-Sam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.11
    • /
    • pp.1038-1043
    • /
    • 2015
  • When the study on the relationship between the Head-of-Bed (HOB) angle and ventilator-associated pneumonia is performed, the fact that the HOB angle can only be measured intermittently imposes a significant limitation on the study. Therefore, there has been demand for the development of a device that can measure the HOB angle continuously. In this paper, we propose the rapid prototyping of an HOB measurement system using open-source hardware and software. The proposed system helps to maintain the HOB angle at a particular angle by displaying the angle and helps the medical study of pneumonia patients by enabling continuous data acquisition. Firstly, we eliminate the process of making an MCU board by utilizing an open-source hardware mbed LPC1768. Secondly, we reduce the software development time by using libraries and hence enabling the easy use of peripherals. Thirdly, for rapid prototyping, we build the enclosure of the proposed system using a 3D printer. The proposed system can be attached and detached to and from a bed. Therefore, we can attach it to the bed of a patient for whom measurement of the HOB angle is necessary. Finally, we check the measurement performance and the validity of the proposed system through an experiment utilizing an incremental encoder.

Evaluation of Masseter Muscle Volume after Contouring of Prominent Mandible Angle by Measurement of CT Scan Image

  • Kim, Yong Oock;Choi, Jong Woo
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.2
    • /
    • pp.71-74
    • /
    • 2014
  • Purpose The prominent mandible angle, otherwise known as "square face", has been recognized as an aesthetic problem that needs correction by many in the Asian community. Many surgeons considered that mandible angle ostectomy alone, brings about hypotrophy of the masseter muscle. However, it was only proven indirectly (by clinical experience and histological animal experiments) and not objectively. In this study, we evaluated the volume of masseter muscle to prove the effect, objectively. Materials and method Computed tomography (CT) images were used to measure the masseter muscle volume of normal female group (n=6), and of female patient group n=8, preoperative and early & late postoperative volumes) presenting the symptom of prominent mandible angle. The data was analyzed statistically by two-sample t-test and paired t-test using SAS (version 8.2). Results In normal female group, volume average was $16,142{\pm}2,829.8mm^3$. In patient group, preoperative volume averaged $24,447{\pm}4,544.5mm^3$ (p<0.0001), early postoperative volume measured average of $31,966{\pm}50,421mm^3$ which is a 30% increase from the preoperative volume (p<0.0001). Late postoperative measurement was $20,202{\pm}4,092.3mm^3$, which is a 20% decrease from the preoperative volume (p<0.0006). Conclusion The bone reduction of prominent mandible angle induce the hypotrophic effect of masseter muscle after long term follow up (5 more months). This result mean that the result of mandible angle contouring surgery can be considered as combined effect of bony angle reduction and subsequent masseter muscle hypotrophy.

Experimental study on the influence of heating surface inclination angle on heat transfer and CHF performance for pool boiling

  • Wang, Chenglong;Li, Panxiao;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.;Deng, Jian
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.61-71
    • /
    • 2022
  • Pool boiling heat transfer is widely applied in nuclear engineering fields. The influence of heating surface orientation on the pool boiling heat transfer has received extensive attention. In this study, the heating surface with different roughness was adopted to conduct pool boiling experiments at different inclination angles. Based on the boiling curves and bubble images, the effects of inclination angle on the pool boiling heat transfer and critical heat flux were analyzed. When the inclination angle was bigger than 90°, the bubble size increased with the increase of inclination angle. Both the bubble departure frequency and critical heat flux decreased as the inclination angle increased. The existing theoretical models about pool boiling heat transfer and critical heat flux were compared. From the perspective of bubble agitation model and Hot/Dry spot model, the experimental phenomena could be explained reasonably. The enlargement of bubble not only could enhance the agitation of nearby liquid but also would cause the bubble to stay longer on the heating surface. Consequently, the effect of inclination angle on the pool boiling heat transfer was not conspicuous. With the increase of inclination angle, the rewetting of heating surface became much more difficult. It has negative effect on the critical heat flux. This work provides experimental data basis for heat transfer and CHF performance of pool boiling.

Effects of the Pelvic Control Method on Abdominal Muscle Activity and Lumbopelvic Rotation Angle during Active Straight Leg Raising in Patients with Chronic Low Back Pain (만성요통환자의 능동 하지직거상 동작 시 골반조절 방법에 따른 복부 근활성도와 요골반부 회전각도에 미치는 영향)

  • Kim, Dae-Hyun;Park, Jin
    • PNF and Movement
    • /
    • v.18 no.2
    • /
    • pp.223-231
    • /
    • 2020
  • Purpose: The purpose of the study was to compare the effects of different methods of pelvic control on abdominal muscle activity and lumbopelvic rotation angle during active straight leg raising (ASLR) in patients with chronic back pain. Methods: The study participants were patients with low back pain (n = 30). They were instructed to perform ASLR with pelvic control, ASLR with pelvic belt, and ASLR only. Surface electromyography data were collected from the ipsilateral rectus femoris (IRF), ipsilateral internal oblique (IIO), contralateral external oblique (CEO), and ipsilateral rectus abdominal (IRA) muscles, and lumbopelvic rotation angle was measured using a motion analysis device. Results: Activation of all abdominal muscles was greater in the ASLR with pelvic control group than in the ASLR with pelvic belt and ASLR groups. The lumbopelvic rotation angle was lower in the ASLR with pelvic control group than in the other two groups (p < 0.05). Conclusion: These results suggest that ALSR with pelvic control is an effective means of increasing abdominal muscle activity and reducing unwanted lumbopelvic rotation in patients with chronic low back pain. Controlling the pelvis using the opposite leg is an effective form of ASLR exercise for patients with chronic low back pain.

Assessment of Lumbar Spine Kinematics by Posterior-to-Anterior Mobilization

  • Oh, Kang O;Lee, Sang-Yeol
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.4
    • /
    • pp.450-456
    • /
    • 2021
  • Objective: Studies confirming the lumber spine kinematics of direct or indirect segmental mobility under the application of joint mobilization, which induces passive force on the spine, are insufficient.Therefore, this study aims to obtain the underlying clinical data by identifying direct or indirect segmental mobility produced by Maitland's PA mobilization technique. Design: Randomized controlled trial design. Methods: Thirty subjects with no back pain participated in this study. X-ray testing equipment (SIG-40-525, Ecoray Inc., Korea) was used to verify the segmented movement of their lumbar. Joint mobilization was performed by physiotherapists with more than 10 years of experience in prescription therapy, and radiography was performed once without PA joint mobilization and once without the mobilization for comparing the lumbar vertebrae before and after the mobilization. The radiographs taken were analyzed using the picture archiving and communication system (PACS) program to measure the spinal displacement, intervertebral height, intervertebral angle, and lumbar lordosis angle. Results: Significant differences were observed in the lumbar displacement, intervertebral angle, and lumbar lordosis angle in all lumbar vertebrae before and after the mobilization. The intervertebral height indicated significant differences in all ventral vertebrae and only in L3-L4 and L4-L5 in dorsal vertebrae. Conclusions: This study suggests that the segmental mobility produced through indirect approaches plays an important role in inducing therapeutic effects in patients with back pain.

Kinematic Analysis of Lower Extremities during Staris and Ramp Walking with Hemiplegic Patients (편마비 환자의 계단과 경사로 보행 동안 하지의 운동학적 분석)

  • Cheon, Dong-Whan
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.5
    • /
    • pp.297-302
    • /
    • 2013
  • Purpose: This study was conducted in order to investigate the kinematic gait parameter of lower extremities with different gait conditions (level walking, stair, ramp) in hemiplegic patients. Methods: Ten hemiplegic patients participated in this study and kinematic data were measured using a 3D motion analysis system (LUKOtronic AS202, Lutz-kovacs-Electronics, Innsbruk, Austria). Statistical analysis was performed using one-way repeated measure of ANOVA in order to determine the difference of lower extremity angle at each gait phase with different gait conditions. Results: Affected degree of ankle joint in the heel strike phase showed significant difference between level walking and climbing stairs, and toe off phase showed significant difference between level walking and climbing stairs, ramps, and climbing stairs. Affected degree of knee joint showed no significant difference in all attempts. Affected degree of hip joint in the toe off phase showed significant difference between level walking, ramps and stairs, and climbing ramps. Swing phase showed significant difference between sides for level walking and stairs, climbing ramps. Affected ankle joint of heel strike and toe off, and affected hip joint of toe off and the maximum angle of swing phase in the angle was increased. Unaffected side of the ankle joint, knee joint, and hip joint showed a significant increase in walking phase. Conclusion: These findings indicate that compared with level walking, different results were obtained for joint angle of lower extremity when climbing stairs and ramps. In hemiplegia patient's climbing ramps, stairs, more movement was observed not only for the non-affected side but also the ankle joint of the affected side and hip joint. According to these findings of hemiplegic patients when climbing stairs or ramps, more joint motion was observed not only on the unaffected side but also on the affected side compared with flat walking.

A Study on Characterizing a Healthy Driving Posture (건강한 운전 자세 특성 연구)

  • Kim, Darae;Choi, Hyungyun;Lee, Joungho;Ahn, Sungmin;Lee, Shiuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.5
    • /
    • pp.121-129
    • /
    • 2013
  • To find a healthy driving posture, in this study, survey and empirical analysis given onto measurement of car-seat angle has been performed. Among 153 male respondents, those drivers who has minimum 5 year experience and 2 hours daily driving has been selected by a multiple screening process. They were further confirmed to have no discomfort history in any body region caused by the driving task. Final 44 people verified that their actual driving posture is not significantly different (p = 0.692) from healthy one they think. And their data, accordingly, the healthy driving postures are clustered based on the same seat-cushion angle, seat-back angle and trunk-thigh angle. Consequently, three seat-angles of the 44 subjects showed a significant difference only with their height information which is the most effecting factor on driving posture among the physical characteristics. That is a first result categorized healthy driving posture classified physical, if it were departmentalized into additional study, could be able to reflected a factor of "healthy" on car seat design.

GPS Accuracy Revision Using RSSI and AoA in Wireless Sensor Network (무선 센서 네트워크에서 RSSI와 AoA를 활용한 GPS 정밀도 향상 방안)

  • Cho, Hae-Min;Kwon, Tae-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.889-896
    • /
    • 2022
  • Data required in a wireless sensor network environment requires more accurate figures as technology advances and its complexity increases. However, in the case of operating a large number of sensor nodes in a large area, the balance between the power consumed and the data quality that can be acquired accordingly should be considered for that purpose. In particular, in complex, densely populated urban areas or military operations with specific goals, location data requires increasingly detailed and high accuracy over a wide range. In this paper, we propose a method of mounting a Global Positioning System(: GPS) only on some of the sensor nodes deployed in the wireless sensor network and improving the error of GPS location data measured on that sensor node through Angle of Arrival(: AoA) and Received Signal Strength Indicator(: RSSI).

Performance comparison of MIMO-VLC systems according to the change of an emission angle (발광 각도 변화에 따른 MIMO-VLC 시스템의 성능 비교)

  • Lee, Byung-Jin;Kim, Yong-Won;Kim, Young-Keun;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.73-79
    • /
    • 2014
  • Visible light communication is a communication method using an LED having a high-speed ON / OFF rate data to be transmitted, it is used as a wireless high speed data transmission. VLC system evolves, the problem of basic research is intended to improve performance and ensure reliability of the communication. The nature of the visible light communication, communication is performed only in the reach of the light, which indicates a big difference by the emission angle of the light. Therefore, in this paper, in the case of indoor environments generally, with the attributes of the multiple LED is equipped, was applied to a MIMO (Multiple Input Multiple Output) communication system. and analyzed SNR performance and total power can be obtained on the reception side by changing the emission angle of the transmitter. As a result of the simulation was run against this, it was confirmed that there is a significant impact on the performance of BER and SNR performance by the emission angle of the transmitter.

Simplified Noise Modeling of GPS Measurements for a Fast and Reliable Cycle Ambiguity Resolution

  • Park, Byung-Woon;Kee, Chang-Don
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.535-540
    • /
    • 2006
  • The relationship between the observable noise model and the satellite elevation angle can be modeled quite well by an exponential function.[Jin, 1996] Noise size and dependence on the elevation angle are, however, different for each observation and receiver type. Therefore, the coefficient determination of this model is an issue, and various methods including PR-CP, single difference, and time difference have been suggested. The limitations of them are difficulty to model the carrier phase noise and to eliminate bias. To overcome these disadvantages for using Jin's model, we suggest zero baseline double difference (DD) and noise sorting algorithm. Data DD technique in zero baseline is useful to eliminate all the troublesome GPS biases, and the remaining error is the sum of GPS measurement noises from two satellites. These DD residuals for hours should be sorted by the combination of satellite elevation angles, and then variance value of the residual for each combination can be estimated. Using these values, we construct an over-determined linear equation whose solution is a set of noise variance for each satellite elevation angle. With 24hr Trimble 4000ssi data, we easily worked out the coefficients of the noise model not only for pseudorange but also for carrier phase. We estimated the standard deviation of the measurement DD using our model, and plotted 1 and 3 sigma lines for every epoch to verify the representation of the residual error. 63.3% of pseudorange residual and 65.9% of phase error did not exceed the 1 sigma lines. Additionally, 99.2% and 99.5% of them lied within 3sigma line. These figures prove that the Gaussian property of measurement noise, and that the suggested model by our algorithm corresponds to the observable noise information.

  • PDF