• Title/Summary/Keyword: angle-only data

Search Result 337, Processing Time 0.028 seconds

The Effect of External-rotation Reducing Exercise on the Gait of Patient with Hemiplegia (편마비 환자의 보행에 대한 외회전 감소운동의 효과)

  • Kim, Ah-Ram;Park, Cheol-Ju;Ryu, In-Jeong;Choi, Jeong-Wook;Hyun, Ju-Hyup;Cho, Nam-Jung;Yoo, Byung-Kook;Jeong, Jong-Hee;Lee, Ho-Jun
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.6 no.1
    • /
    • pp.69-79
    • /
    • 2008
  • In this paper, the effects of the external-rotation exercise on the gait of hemiplegia was investigated. 26 patients with hemiplegia due to cerebrovascular accident participated in this study. Subjects were randomly assigned to experimental group(n=12) and control one(n=14). 12 subjects of the experimental group were received the external rotation reducing exercise on the mat with seating and supine posture after the general therapeutic exercise for hemiplegia. 14 subjects of the control group were received only general therapeutic exercise. The effects of external rotation reducing exercise were evaluated by measurements of gait velocity, cadence, stride length, step length and foot angle using ink-foot prints. The collected data were analyzed statistically based on Wilcoxon, Mann-Whitney and correlation analysis. After treatment of three weeks, it turned out that external rotation reducing exercise has the significant effect on foot angle(p<0.01). However the exercise has no statistically significant direct effect on the gait velocity, cadence, stride length and step length.

  • PDF

The Effect of Sesamoid Position on Results of Treatment for Hallux Valgus (무지외반증에서 종자골 전이 정도가 치료결과에 미치는 영향)

  • Yoo, Chong-Il;Lee, Dong-Ho;Kim, Hui-Taek
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.2
    • /
    • pp.131-137
    • /
    • 2004
  • Purpose: We evaluated the results of various surgical treatments for hallux valgus with and without attempting to correct sesamoid subluxation. Materials and Methods: Thirty-one cases in 26 patients were involved in this study: Group I (15 cases) - surgery performed only to correct the hallux valgus angle (HVA) and the first-second intermetatarsal angle (IMA) in AP view; Group II (16 cases) - surgery performed to correct HVA and IMA and also to reduce the subluxation of sesamoid. The degree of sesamoid subluxation was measured from a pre- and intraoperative sesamoid tangential views. For both groups, we analysed the status of the sesamoid in pre- and postoperative radiographs and performed clinical evaluation using the Mayo clinic forefoot scoring system. Results: The average amount of correction during postoperative period and loss of correction at last follow-up in the sesamoid tangential view were as follows: soft tissue procedures (5 cases) - group I: grade $1.0{\pm}0.4/1.5{\pm}0.3$ and group II: grade $2.0{\pm}0.9/0.5{\pm}0.08$; chevron osteotomy (12 cases) - group I: grade $1.0{\pm}0.5/1.2{\pm}0.3$ and group II: grade $2.2{\pm}0.7/0.9{\pm}0.2$; proximal metatarsal osteotomy (14 cases) - group I: grade $4.0{\pm}0.4/1{\pm}0.2$ and group II: grade $4.7{\pm}1.1/0.8{\pm}0.1$. In clinical evaluation, more than 93% of the feet had a good result in both groups. The analysis of these data for each treatment type did not show any statistically significant differences between groups I and II. Conclusion: The radiologic and clinical results did not validate our attempts to reduce the sesamoid during surgery.

  • PDF

A Study on the Relation between Occlusal Wear Area and Occlusal Contact Patterns (교모면적과 교합접촉양태 간의 관계에 대한 연구)

  • Se-Sook Kang;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.153-168
    • /
    • 1994
  • The aim of the present study was to investigate a relation between occlusal wear area and occlusal contact patterns. For the purpose, occlusal wear area were measured in 58 dental students and in 129 patients with temporomandibular disorders(TMDs) from dental casts. Teeth used in this study were from canine to second molar on both sides in upper arch, totally ten. Occlusal wear area on casts was marked by pencil and photocopies, and then, the area was measured with planimeter. Occlusal relation was clinically examined with regard to Angle's classification, chewing side preference, lateral guidance pattern and bruxing and/or clenching habit. T-Scan, electronic occlusal contact analyzer, was used to record occlusal contact number, contact force, contact time and occlusal balance that is TLR(total left-right statistics) during tooth contact. All measurement were repeated 3 times and the average value was used for data processing. The obtained results were as follows : 1. Mean value of occlusal wear area did not differ significantly between dental students and patients. 2. There ws not significant difference in wear area between chewing side and non-chewing side in both groups. 3. Occlusal wear area was significantly increased with age in both groups. 4. Three subgroups divided by Angle's classification did not show any difference in occlusal wear area among them, but three subgroups divided by lateral guidance pattern showed slightly significant difference between canine guide subgroup and group function subgroup in patients. Occlusal wear ares\a in group function subgroup wear larger than canine guide subgroup. 5. Mean value of wear area in patients with bruxing and/or clenching habit did not differ from those in patients without such habit. 6. Correlationship among items related to occlusal contact pattern were highly consistent and significant in dental students and only one item significantly correlated with occlusal wear area was tooth contact time.

  • PDF

Analysis of Sloping Ground When Lifting with Force Platform (힘판을 이용한 들기 작업시의 경사면 분석)

  • 서승록;김종석
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.5 no.1
    • /
    • pp.77-86
    • /
    • 2000
  • Even manual materials handling tasks(MMHT) is decreasing by adopt of automatic manufacturing system & transportation supporting machine because of increase of productivity, wage lack of labor, safety, in fact working at inclined & complicated slope such as farm, orchard, harbor loading & unloading, logging place and mining place can't be substituted by machine perfectly. So, workers should do MMHT at this place by themselves, lifting on slope can cause much of hazard, include falling. Keeping balance net to slip can be a reason of low back pain(LBP) by overloaded musculoskeletal system but, there's no enough study about lift on slope. Therefore, In this study, we assessed and analyzed change of center of pressure(COP) when lifting on slope by force platform. The result showed that the length lengthen as increasing angle of slope. Especially, the length extremely increased over 15°. Through These basic result, present proper angle boundary, prevent industrial accidents and give proper data not only lifting but also pushing and pulling on slope someday.

  • PDF

Characterization of In-plane Shear Behaviors of Woven Fabrics by Bias-extension and Trellis-frame Tests (편향 인장 및 트렐리스 시험에 의한 직물 복합재료의 면내 전단 물성 평가)

  • Lee, Won-Oh;Um, Moon-Kwang;Byun, Joon-Hyung;Cao, Jian
    • Composites Research
    • /
    • v.23 no.5
    • /
    • pp.8-14
    • /
    • 2010
  • Three types of glass woven fabrics (plain, balanced twill, and unbalanced twill) having various sample sizes and aspect ratios were tested using the bias-extension tests. Real-time deformation images, force, and displacement data were collected. For the bias-extension test, the shear angle of the fabrics from the equation based on the crosshead displacement and fabric size was compared with direct manual measurements of the warp and weft angles as well as the optical measurement software. To determine the shear force, an analytical equation was introduced considering the kinematics of the bias-extension test. The obtained shear behaviors were further compared with the results by the trellis-frame test. The optical measurement methods showed that the mathematical method was reasonable before the shear angle of the fabrics reaches $30^{\circ}$ in the bias-extension tests. Also, the bias-extension test gave consistent behaviors with the trellis-frame test only for isotropic and homogeneous fabrics such as balanced plain and twill weaves.

Analysis of the Foot Indices Using Dynamic and Static Check of Postgraduate School Students in Yangsan (양산지역 대학원 일개 학년 학생을 대상으로 동적검사 및 정적검사를 통한 족부지표 분석)

  • Tcheun, Kyoung-Jae;Park, Dal-A;Shin, Byung-Cheul;Hwang, Eui-Hyoung;Heo, In;Kim, Byung-Jun;Lim, Kyeong-Tae;Heo, Kwang-Ho
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.11 no.1
    • /
    • pp.33-40
    • /
    • 2016
  • Objectives : To evaluate the foot indices using dynamic and static checking on healthy adult people. Methods : Foot indices analysis was performed for 46 students. Static checking practiced for Foot Pressure(FP) and Toe Pressure Difference(TPD) and dynamic checking was used for Vertical Axis Angle(VAA). Results : On gender, there was generally no statical significant difference, except RFP(Right Foot Pressure). The RFP of male was bigger than that of female. On age, in addition, there was similar tendency, only RFP had a positive correlation (r=0.35, p<0.05). Comparing foot indices on right and left, we found TPD and VAA had a tendency of pronation on left, but FP had a opposite tendency. On consistency of each foot index, discrepancy between TPD and VAA (39.47%) was lesser than combination of the others. Conclusions : According to foot indices among 46 healthy student, we found out that there is partially correlation between dynamic and static checking. We hope that the data we found will contribute to standardization of podiatry indices which provide medical guidance for cure of foot disease, supporting further podiatry research.

  • PDF

Correlation Between Joint Angular Displacement and Moment in the Human Foot (인체 족부관절의 각변위와 모멘트의 상관관계)

  • 김시열;신성휴;황지혜;최현기
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.209-215
    • /
    • 2003
  • The goal of this study was to investigate the relationship between kinematic and kinetic characteristics of foot joints resisting ground reaction force. Passive elastic joint moment and angular displacement were obtained from the experiment using 3 cameras and force plate. The relationship between joint angle and moment was mathematically modeled by using least square method. The ranges of motion of joints ranged from 5$^{\circ}$ to 7$^{\circ}$ except metatarsophalangeal joint. In the study, we presented simple mathematical models that could relate joint angle and plantar pressure. From this model, we can got the kinematic data of joints which is not available from conventional motion analysis. Furthermore, the model can be used not only for biomechanical model which simulates gait but also for clinical evaluation.

Suppression of performance degradation due to cold-head orientation in GM-type pulse tube refrigerator

  • Ko, Junseok;Kim, Hyobong;Park, Seong-Je;Hong, Yong-Ju;Koh, Deuk-Yong;Yeom, Hankil
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.4
    • /
    • pp.50-53
    • /
    • 2012
  • This paper describes experimental study on GM-type pulse tube refrigerator (PTR). In a PTR, the pulse tube is only filled with working gas and there exists secondary flow due to a large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus, the cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube refrigerator is fabricated and tested. The cooing performance of the fabricated PTR is measured as varying cold-head orientation angle and the results are used as reference data. Then, we divided interior space of pulse tube into three segments, and fixed the various size of screen mesh at interface of each segment to suppress the performance degradation due to secondary flow. For various configuration of pulse tube, no-load test and heat load test are carried out with the fixed experimental condition of charging pressure, operating frequency and orifice valve turns. From experimental results, the fine screen mesh shows the effective suppression of performance degradation for the large orientation angle, but the use of screen mesh cause the loss of cooling capacity rather than the case of no insertion into pulse tube. It should be compromised whether the use of screen mesh in consideration of the installation limitation of a GM-type pulse tube refrigerator.

A Study of the Thrust Vectoring Control Using Secondary Co- and Counter-Streams (2차 순유동과 역유동을 이용한 추력벡터 제어법에 관한 연구)

  • Lim Chae-Min;Kim Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.109-112
    • /
    • 2004
  • Of late, the thrust vectoring control, using fluidic co-flow and counter-flow concepts, has been received much attention since it not only improves the maneuverability of propulsive engine but also reduces an additional material load due to the trailing control wings, which in turn reduce the aerodynamic drag. However, the control effects are not understood well since the flow field involves very complicated non: physics such as shock wave/boundary layer interaction, separation and significant unsteadiness. Existing data are not enough to achieve the effectiveness and usefulness of the thrust vectoring control, and systematic work is required for the purpose of practical applications In the present study, computational study has been performed to investigate the effects of the thrust vector control using the fluidic co-and counter-flow concepts. The results obtained show that, for a given pressure ratio, the thrust deflection angle has a maximum value at a certain suction flow rate, which is at less than $5\%$ of the mass flow rate of the primary jet. With a longer collar, the same vector angle is achievable with smaller mass flow rate.

  • PDF

Development of a Simple Drape Measurement Method for 3D Virtualization (3D 가상화를 위한 드레이프성 간이 측정법 개발)

  • Shin, Bona;Yu, Dongjoo;Lee, Somin;Youn, Seonyoung;Shim, Myounghee;Yun, Changsang
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.5
    • /
    • pp.881-891
    • /
    • 2021
  • This study proposes a simple drape measurement method for the 3D virtualization of garments. The proposed method uses angles or disks of different diameters to evaluate the drape properties easily. We divided 710 fabrics into ten groups based on the drape coefficient, of which 49.6% had drape coefficients of 30 or less. The drape properties were measured to classify the groups into smaller clusters using the angle formed when the center of the fabric was fixed. Accordingly, three clusters were formed for 60° and 100° angles. A method was devised using ten disks of different diameters to classify the remaining two clusters, except the cluster containing only the D10 group (D1-D5 and D5-D9). Three criteria-grade match, a sum of deviation, and standardization of deviation-were used for the classifications. The discriminative ability between groups was high for D1-D5 with disks with 24.0 and 25.5 cm diameters. Furthermore, a disk with a diameter of 16.5 cm was effective for D5-D9. The three-dimensional drape shapes were unique for the ten groups, which can be utilized as fundamental data for 3D virtualization.