• Title/Summary/Keyword: angle reference

Search Result 742, Processing Time 0.022 seconds

Chinese relationship between animation and best pole - Focused on the aesthetic principles of the Cultural Revolution period (중국 애니메이션과 모범극의 상관관계 연구 - 문화대혁명 시기의 미학 원칙을 중심으로)

  • Kong, De Wei
    • Cartoon and Animation Studies
    • /
    • s.39
    • /
    • pp.215-231
    • /
    • 2015
  • The Cultural Revolution in the history of Chinese animation hinder the development of the initial animation, and after a negative assessment instrument provided the cause is to become sluggish growth of the Chinese animation. So this time animation are things that are the subject of academic research studies or analysis has been depreciating almost uniformly without evaluation. However, of all the cultural and artistic creation it is developing in its own specific historical conditions and has the aesthetic results. This paper puts the primary purpose is to hold in consideration the aesthetic principles that led to cultural and artistic creativity and objective perspective the achievements the Chinese animation of the time period of the Cultural Revolution. Cultural Revolution is avoided to the previous period in accordance with the socialist ideology of Mao Ze-dong(毛澤東) sikindaneun highlight the culture of the proletariat and placed our goal to create a new class culture. Therefore, cultural and artistic creation of this period is often inconsistent with this part of our aesthetic principles generally accepted character has a non- elitist and anti properties. Best drama is a creative one hand as a model to implement the principles of aesthetics, art and culture Cultural Revolution period kkophimyeo reference for understanding the aesthetic principles that animated the Chinese Cultural Revolution period of orientation. This paper has San Tu Chu(三突出), Hong Guang Liang(紅光亮), and Gao Da Quan(高大全) at the time of the Cultural Revolution aesthetic principles are reflected in how the concrete work, the Cultural Revolution when the animation is how to accommodate these aesthetic principles and placed emphasis on comparative studies on best pole and correlation of the Cultural Revolution when the Chinese animation to ensure that adaptation in own way. First, after analyzing whether the aesthetic principles of focusing on the similarities of the best pole time of the Cultural Revolution and China, and how to implement animation in the works, these aesthetic principles according to the analysis of positive and negative influence on the creation of Chinese animation It was described as neutral. The detailed analysis and comparative study courses were trying to access in two significant aspects of the characters and scenes directing. In terms of character animation of the Cultural Revolution in China when a young boy or girl, emphasis should emphasize the health tinged with red lips and cheek blush to highlight the desired Gong Nong Bing(工農兵) shape as the main character and smooth texture and sophisticated highlights the glittering feeling to the touch, it was confirmed focused hayeoteum to implement the principle of 'Hong Guang Liang', highlighting the brilliant colors with a clean, bright colors. Highlighting a number of protagoniste compared to the antagonist in the animated scene of the Cultural Revolution a few times in terms of production and, among a number of protagoniste also emphasizes the outstanding hero figure, "yet three outstanding heroes heroic figures also emphasize the leading figures among the the director of the extrusion step-by-step approach "('San Tu Chu')was used. In addition, the hero figure is generally high and low angle by directing a large and perfect aesthetic appearance was to faithfully implement the principle of 'high-charged'('Gao Da Quan').

Effect of Carbon Couch Side Rail and Vac-lok In case of Lung RPO irradiation (Lung RPO 선량전달시, Carbon Couch Side Rail과 Vac-lok이 미치는 영향)

  • Kim, Seok Min;Gwak, Geun Tak;Lee, Seung Hun;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.27-34
    • /
    • 2018
  • Purpose : To evaluate the effect of carbon couch side rail and vacuum immobilization device in case of lung RPO irradiation. Materials and Methods : The 10, 20, 30 mm thickness of vac-lok's right side were obtained. To measure of doses, glass dosimeters were used and measured reference point is left lung center at the phantom. A, B, C, and D points are left, right, down, and up directions based on the center point. In the state of Side-Rail-Out, place the without vac-lok, with the thickness of 10, 20, and 30 mm vac-lok. After the glass dosimeters was inserted in center, A, B, C, and D points, 100 MU of 6 MV X-ray were irradiated to the referenced center point in the condition of $10{\times}10cm^2$ field size, SAD 100 cm, gantry angle 225, 300 MU/min dose rate. Five measurements were made for each point. In the state of Side-Rail-In, five measurement were made for each point under the same conditions. The average is measured on each of the five Side-Rail-Out and Side-Rail-In measurements. Results : In the presence of side rail, the dose reduction ratio was -11.8 %, -12.3 %, -4.1 %, -12.3 %, -7.3 % for each A, B, C, and D points. In the state of Side-Rail-Out, the dose reduction ratio for the using 10 mm thickness of vac-lok was -0.9 % than without vac-lok. The dose reduction ratio for the using 20 mm thickness of vac-lok was -2.0 %, for the using 30 mm thickness of the vac-lok was -3.0 % than without vac-lok. In the state of Side-Rail-In, the dose reduction ratio for the using 10 mm thickness of vac-lok was -1.0 % than without vac-lok. The dose reduction ratio for the using 20 mm vac-lok was -2.1 %, for the using 30 mm vac-lok was -3.0 % than without vac-lok. Based on the value of no vac-lok dose in the Side-Rail-In state, The dose reduction ratios for the using 10 mm, 20 mm and 30 mm thickness of vac-loks In the Side-Rail-Out that the center point were -12.7 %, -13.7 %, -14.2 % and -12.8 %, -13.8 %, -14.5 % respectively at point A. The dose reduction ratios for the same conditions to the B point were -4.9 %, -6.1 %, -7.1 % and -13.4 %, -14.4 %, -15.5 % respectively at point C. The dose reduction ratios for the same conditions to the D point were -8.4 %, -9.0 %, -10.4 % respectively. Conclusion : The attenuation was caused by presence of side rails and thickness of vac-lok. Pay attention to these attenuation factors, making it a more effective radiation therapy.

  • PDF