• 제목/요약/키워드: angle of incidence

검색결과 585건 처리시간 0.028초

이중판의 차음손실 I (Sound Transmission Loss of Double Panels(I) : A Double Wall with Air Cavity)

  • 강현주;김현실;김재승;김상렬
    • 소음진동
    • /
    • 제7권6호
    • /
    • pp.945-952
    • /
    • 1997
  • This paper shows the feasibility of the suggestion that the angle distribution of incident sound to panels might be gaussian, instead of the conventional uniform distribution in the analysis of transmission loss of panels. To prove the suggestion, the problems with the diffuse sound field in a reverberation room are examined by case studies and the comparision of the prediction with the measurement of sound transmission loss of walls are performed. The results of the comparision show good agreement between the two values.

  • PDF

경사입사 증착법 (나선형 구조)을 이용한 원편광 분리소자의 설계 및 제작 (Design and fabrication of circular-polarization separator using a glancing angle deposition (Helical structure))

  • 박용준;황보창권
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2007년도 동계학술발표회 논문집
    • /
    • pp.151-152
    • /
    • 2007
  • In this study, the optical porosity of $TiO_2$ films with helical structure deposited by glancing angle deposition (GLAD) were investigated. Helical films are of interest due to their ability to differentiate states of circularly polarized light. We designed and fabricated normal-incidence circular-polarization separator deposited by GLAD (Helical structure). The optical porosity of $TiO_2$ film deposited by helical method can be applied many optical coatings.

  • PDF

하악제3대구치의 존재양상과 하악우각부 골절과의 관계 (RELATIONSHIPS BETWEEN MANDIBULAR ANGLE FRACTURE AND STATE OF THE LOWER THIRD MOLAR)

  • 김희광
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권6호
    • /
    • pp.530-535
    • /
    • 2004
  • Objectives. The purpose of this study was to evaluate mandibular third molars as risk factors for angle fracture in a patient sample with fractured mandible. Materials and methods. The medical records and panoramic radiographs of 107 patients with mandibular fractures were examined. The presence and absence and degree of impaction of the lower third molar were assessed for each patient and related to the occurrence of fracture of the mandibular angle. Data were also collected for age, sex and mechanism of injury. Data were analyzed by a chisquare statistics and Student t test. Result. The incidence of mandibular angle fracture was found to be significantly greater when a lower third molar was present(p <0.05) especially at class III state.(p < 0.05)(by Pell & Gregory system) Of the 78 patients with a lower third molar, 46(58.97%) had angle fractures. Of the 29 without a lower third molar, 24(82.76%) had not angle fractures. Conclusion. The result of this study showed that the mandibular angle that have a lower third molar is more susceptible to fracture when exposed to an impact than an angle without an lower third molar.

실습선 가야호의 해상상태와 선내 위치에 따른 뱃멀미 지수에 관한 연구 (A Study on the Motion Sickness Incidence due to Sea State and Location of the Training Ship Kaya)

  • 한승재;하영록;김종화;이종근;김인철
    • 수산해양교육연구
    • /
    • 제26권1호
    • /
    • pp.126-133
    • /
    • 2014
  • For boarding comfort and pleasant boarding sensitivity of passenger in passenger ship, there are a few methods such as motion sickness rate or MSI(Motion Sickness Incidence) to assess safety of passenger ship. To find out MSI or motion sickness rate of the training vessel Kaya of Pukyong National University, we use lots of various factors: sea condition, incident angle in main sail way, economic speed, calculation position of motion sickness, sea state, work place and reduce zone of ship. In this paper, we adopted Maxsurf Seakeeper program based on Strip Theory and carefully compared theoretical results with experimental results.

The effect of Ion Beam modification of Polyimide surface on alignment properties of liquid crystals

  • Cho, Seong-Jin;Kim, Chan-Soo;Roh, Jin-A;Gwag, Jin-Seog;Kim, Jae-Chang
    • 한국진공학회지
    • /
    • 제12권S1호
    • /
    • pp.107-112
    • /
    • 2003
  • The alignment effect of liquid crystals on Polyimide surfaces bombarded by a low energy argon ion beam and the effect of pretilt angle on viewing characteristics of an LCD cell are discussed. The unidirectional out-of-plane liquid crystal tilt angle is varied with various ion beam irradiation conditions, such as the energy of the incident ions, the angle of incidence and exposure time. As low pretilt angle is profitable for wider viewing property, LCD cell with ion beam modified Polyimide layer show wider viewing characteristics.

고분자막에 직선편광된 UV광의 경사진 조사법을 이용한 액정배향 및 프리틸트각의 조사각도 의존성 (Incident angle dependence of pretilt and LC alignment with oblique polarized UV light irradiation on polymer surface)

  • 서대식;유문상;황정연;박태규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1395-1397
    • /
    • 1998
  • In this paper, we studied the liquid crystal(LC) alignment and generation of pretilt angle in nematic (N) LC with oblique p-wave polarized ultraviolet (UV) light irradiation on the two kinds of the polyimide (PI) surface. The monodomain alignment of NLC is obtained with oblique p-wave polarized UV light irradiated on PI surface at 5$\sim$60min. We obtained that the pretilt angles of the NLC is generated about $2.1^{\circ}$ with angle of incidence of $30^{\circ}$ at 20min. Also, the pretilt angle of NLC decreases with increasing the imidization temperature on PI surface.

  • PDF

IVRO를 이용한 하악골 전돌증 환자의 수술전후 악관절 증상 변화에 대한 임상적 평가 (A CLINICAL STUDY ON THE CHANGE OF TMJ SYMPTOMS FOLLOWING IVRO IN THE MANDIBULAR PROGNATHISM)

  • 김진권;박광호;김형곤;김상수;김기영;허종기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제19권1호
    • /
    • pp.1-13
    • /
    • 1997
  • Preoperative and postoperative TMJ symptoms were observed in mandibular prognathism of 30 patients operated on by Le Fort I osteotomy and intraoral vertical ramus osteotomy. The alterations of TMJ symptoms were investigated and the relationship between changes of TMJ symptoms and some cephalometric values including occlusal plane angle, mandibular plane angle, posteior ramal height and a degree of deviation of mandibular incisor midline to facial midline were observed. The results are as follows. The incidence of patient with TMJ symptoms before orthognathic surgery was 40% and after orthognathic surgery was 20%. The most frequetly encountered symptoms in orthognathic TMJ dysfunction patients were TMJ pain and/or clicking. After surgery 66% of the preoperative symptomatic patients reported improvement TMJ symptoms. On the orther hand 2 patient (6%) of the preoperative asymptomatic patients developed TMJ symptoms after surgery. Preoperatively, 60% of the facial asymmetric patients with mandibular prognathism had TMJ symptomas. The more severe facial asymmetry was, the higher incidence of TMJ symptoms was. The alteration of occlusal plane angle and mandibular plane angle seems to be one of the contributing factors which make to change TMJ symptoms in orthognathic patients. But its amount seems to be low significance. Increase or decrease of posterior ramal height have influence on the change of TMJ symptoms.

  • PDF

LC Aligning Capabilities of a Nematic Liquid Crystal on Homeotropic Polyimide Surface by New Ion-beam Irradiation

  • Ok, Chul-Ho;Kang, Dong-Hun;Lee, Kang-Min;Han, Jin-Woo;Kim, Byoung-Yong;Oh, Byeong-Yun;Kim, Young-Hwan;Hwang, Jeong-Yeon;Lee, Sang-Keuk;Han, Jeong-Min;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권6호
    • /
    • pp.265-267
    • /
    • 2007
  • The liquid crystal(LC) aligning capabilities of a nematic liquid crystal(NLC) on a homeotropic polyimide(PI) surface using a new ion-beam method were studied. Exposure ion-beam of $45^{\circ}$ incidence angle shows a good LC alignment of the NLC on the homeotropic PI surface. Also, on the homeotropic PI surface, the tilt angle of the NLC by exposure ion-beam of $45^{\circ}$ incidence angle had a tendency to decrease as increased ion-beam energy density. And, on the homeotropic PI surface, the alignment character of the NLC with respect to ion-beam energy was good at 1500 eV. And we achieved satisfactory result for EO character.

Propagation of plane waves in an orthotropic magneto-thermodiffusive rotating half-space

  • Sheokand, Suresh Kumar;Kumar, Rajeshm;Kalkal, Kapil Kumar;Deswal, Sunita
    • Structural Engineering and Mechanics
    • /
    • 제72권4호
    • /
    • pp.455-468
    • /
    • 2019
  • The present article is aimed at studying the reflection phenomena of plane waves in a homogeneous, orthotropic, initially stressed magneto-thermoelastic rotating medium with diffusion. The enuciation is applied to generalized thermoelasticity based on Lord-Shulman theory. There exist four coupled waves, namely, quasi-longitudinal P-wave (qP), quasi-longitudinal thermal wave (qT), quasi-longitudinal mass diffusive wave (qMD) and quasi-transverse wave (qSV) in the medium. The amplitude and energy ratios for these reflected waves are derived and the numerical computations have been carried out with the help of MATLAB programming. The effects of rotation, initial stress, magnetic and diffusion parameters on the amplitude ratios are depicted graphically. The expressions of energy ratios have also been obtained in explicit form and are shown graphically as functions of angle of incidence. It has been verified that during reflection phenomena, the sum of energy ratios is equal to unity at each angle of incidence. Effect of anisotropy is also depicted on velocities of various reflected waves.

The transient sputtering yield change of an amorphous Si layer by low energy $O_2^{+}$ and $Ar^{+}$ ion bombardment

  • Shin, Hye-Chung;Kang, Hee-Jae;Lee, Hyung-Ik;Moon, Dae-Won
    • 한국진공학회지
    • /
    • 제12권S1호
    • /
    • pp.92-94
    • /
    • 2003
  • The sputtering yield change of an amorphous Si layer on Si(100) was measured quantitatively for 0.5 keV $O_2^{+}$ and $Ar^{+}$ ion bombardment with in suit MEIS. In the case of 0.5 keV $O_2^{+}$ ion bombardment, at the initial stage of sputtering before surface oxidation, the sputtering yield of Si was 1.4 (Si atoms/$O_2^{+}$) and then decreased down to 0.06 at the ion dose of $3\times10^{16}O_2\;^{+}\textrm{/cm}^2$. In the case of 0.5 keV $Ar^{+}$ ion bombardment, the sputtering yield of Si for the surface normal incidence was 0.56 at the ion dose of 2.5 ${\times}$ 10$^{15}$ $Ar^{+}\textrm{cm}^2$, and rapidly saturated to 1.2 at dose of $7.5\times10^{15}Ar^+\textrm{cm}^2$. For the incidence angle of 80 from surface normal, the sputtering yield of Si was saturated to about 1.4 at the initial stage of sputtering. The surface transient effects, caused by change in sputtering yield at the initial stage of sputtering can be negligible when 0.5 keV $Ar^{+}$ ion at extremely grazing angle was used for sputter depth profiling.g.