• Title/Summary/Keyword: angle

Search Result 24,686, Processing Time 0.046 seconds

ISOMETRIC BITE FORCE AND ITS RELATION TO CRANIOFACIAL MORPHOLOGY (교합력과 두개안면 형태의 상관관계에 대한 연구)

  • Lee, Taek-Woo;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.21 no.1 s.33
    • /
    • pp.185-195
    • /
    • 1991
  • This study was undertaken to grope the correlation of the maximal bite force and tooth-craniofacial structure. The maximal bite force of 76 adult male, aged 18-28 (mean aged: $23.4{\pm}2.2$) years, was estimated and cephalometric headplates were measured, tabulated and statistically analyzed. The results were as follows. 1. 59.61kg of bite force in first molar, 45.38kg in premolar and 17.10kg in central incisor were arranged. 2. The bite force was negatively correlated to genial angle, mandibular plane angle, the angle between occlusal plane and mandibular plane, the angle between palatal plane and mandibular plane, and positively correlated to posterior height of face, length of mandibular body, length of ramus, facial depth in craniofacial structure. 3. The group with strong bite force showed small genial angle, mandibular plane angle, the angle between occlusal plane and mandibular plane, the angle between palatal plane and mandibular plane, and long posterior height of face, length of mandibular body, length of ramus, facial depth. So they manifested the tendency to brachycephalic pattern, on the other hand, the group with weak bite force manifested the tendency to dolichocephalic pattern. 4. There is no correlationships between bite force and mesial inclination of premolar axis in this subject. 5. It is considered bite force have an effect upon craniofacial pattern, especially upon the lower face.

  • PDF

AN ANALYSIS OF SOFT TISSUE PROFILE (연조직 측모에 관한 분석)

  • Chang, Young-Il;Choi, Hee-Young;Shin, Soo-Jung
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.627-634
    • /
    • 1995
  • The purpose of this study to analyze characteristics of soft tissue profile in Korean young adults. The sample consisted of 50 young adults (25 males and B females) who had pleasing and normal occlusion. Soft tissue analysis (facial convexity angle, nasolabial angle, H-angle, Z-angle, E-line to upper lip, lower lip, Sn-pog' to upper lip, lower lip) was performed on lateral cephlograms. Mem and standard deviation was obtained. When compared by other studies, mean profile of this sample was relatively straighter and both the upper and lower lips was more protrusive.

  • PDF

An Experimental Study on Spray Characteristics of Multi-Hole GDI Injector (다공형 GDI 인젝터의 분무특성에 대한 실험적 연구)

  • Lee, Sung-Won;Park, Sung-Young
    • Journal of ILASS-Korea
    • /
    • v.16 no.4
    • /
    • pp.201-209
    • /
    • 2011
  • Optimum engine performance is obtained when the spray characteristics is well matched to the geometry of a combustion chamber. Among many parameters governing the combustion performance in internal combustion engine, fuel supply characteristics and atomization are important performance factors. Therefore, spray characteristics of high pressure multi-hole injector has been studied experimentally. An experimental test system has been made to operate high pressure injection system and to visualize spray behavior. Spray visualization has been performed to analyze spray formation, spray cone angle, bent angle and penetration length. Spray interaction with piston has been analyzed with various injector installation angle, injection pressure and ambient pressure. Test results show that penetration length is greatly influenced by the injection pressure. Penetration length is decreased as ambient pressure increased. Spray cone angle is increased as injection pressure and ambient pressure increased. However, bent angle is not influenced by the change of injection pressure and ambient pressure. Spray cone angle distribution map is plotted using the experimental data. Fuel movement around the spark-plug has been enforced as increasing injector installation angle.

The effect of pretilt angle on viewing angle in In-Plane switching mode LCD

  • Kang, Dong-Jin;Gwag, Jin-Seog;Park, Kyoung-Ho;Yoon, Tae-Hoon;Kim, Jae-Chang;Lee, Gi-Dong;Kim, Hee;Cho, Seong-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.559-562
    • /
    • 2003
  • The effect of pretilt angle on viewing characteristics of an IPS cell is discussed. We calculated optical viewing angle in the IPS cell as function of pretilt angle from $0.5^{\circ}$ to $4^{\circ}$, so that we could confirm that low pretilt angle was profitable for wider viewing property. In order to verify the calculation, we made an IPS cell with very low pretilt angle by the alignment method using ion beam exposure. In the experiment, we confirmed that wider viewing characteristics can be achieved if lower pretilt angle was applied in IPS mode. And Ion beam alignment method was useful for low pretilt creation.

  • PDF

A novel ECB mode using control of tilt angle for nematic liquid crystal on polyimide surface (폴리이미드 표면에서의 네마틱 액정의 틸트 제어를 이용한 새로운 ECB 모드)

  • Hwang, Jeoung-Yeon;Kim, Kang-Woo;Jeong, Youn-Hak;Kim, Young-Hwan;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.116-119
    • /
    • 2004
  • In this paper, we have improved a novel (ECB) mode using tilt angle in the unique condition by hot-plate equipment. The new control of tilt angle for nematic liquid crystal (NLC) with negative and positive dielectric anisotropy on the rubbed homeotropic polyimide (PI) using baking method by Hot-plate equipment was investigated. LC tilt angle decreased with increasing baking temperature and time. Especially, the low LC tilt angle of positive type NLC $({\Delta}n>0)$ on the rubbed homeotropic PI surface by increasing temperature and time was measured. The EO characteristics of the novel ECB mode using control of tilt angle on the homeotropic surface than that of conventional OCB cell can be improved. We suggest that the developed the Novel ECB cell using control of tilt angle on the homeotropic surface is a promising technique for the achievement of a fast response time and a high contrast ratio.

  • PDF

Correlations Between Quadriceps Angle, Functional Leg Length Discrepancy and Lower Extremity Muscle Strength of Women University Students in Their Twenties (일부 20대 여대생의 넙다리네갈래근 각이 기능적 다리길이 차이 및 하지근력과의 상관관계)

  • Jung, Yeon-Woo;Kim, Yeo-Jin;Lee, Jae-Geun;Doo, Young-Taek
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.20 no.2
    • /
    • pp.9-14
    • /
    • 2014
  • Background: This study aims to examine correlations between quadriceps angle, lower extremity muscle strength and leg length discrepancy. Methods: This study selected 96 healthy women university students as the subjects of research. Quadriceps angle, lower extremity muscle strength and leg length discrepancy were measured. The statistical analysis of the data SPSS/window (version 12.0) were analyzed using the pearson correlation analysis. Results: There were negative correlations between the muscle strength of the right hamstring muscles and the right quadriceps angle in supine and standing positions. Functional leg length discrepancy of left and right quadriceps angle in supine and standing position showed positive correlations. Conclusions: The quadriceps angle affect the knee. An abnormal angle caused weakening of balance. Muscle strength, leg length discrepancy, and affected lower extremity alignment and knee function. These conclusions may prevent exercise limitation or disorders in the subjects and treating the patients with knee injury or patellofemoral pain syndrome with basic therapy intervention.

Effect of Fiber Orientation Angle and Property of Metal Laminate on Impact Behaviors of Fiber Metal Laminates (섬유의 적층각과 금속판의 특성에 따른 섬유 금속 적층판의 충격 손상 거동)

  • Nam, Hyun-Wook;Jung, Sung-Wook;Han, Kyung-Seop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.3
    • /
    • pp.372-380
    • /
    • 2003
  • Impact tests were conducted to study the effect of angle ply and metal laminate on impact damage characteristics of Fiber Metal laminates (FML). Impact tests were conducted using drop weight impact machine and damage behavior were analyzed by comparing with load-displacement curve and surface observation and microscopic observation of cross sections. The effect of angle ply on impact characteristics of FML are influenced by property of metal laminate. i.e., when the metal laminate is not enough to strong to prevent fiber debonding, Angle ply FML is superior to singly oriented ply (SOP) FML because angle ply enhance the stiffness by fiber supports and prevent (rack propagation. However, when the metal laminate is enough to strong to prevent fiber debonding, SOP FML is superior to Angle ply FML because the fiber of lower ply in Angle ply FML are more stressed than that of SOP FML.

Effects of EMG-Biofeedback Training on Functional Ability and Q-angle in Patellofemoral Pain Syndrome (근전도-생체되먹임 훈련이 무릎넙다리통증의 기능적 능력과 Q-각에 미치는 영향)

  • Park, Seung-Kyu;Kang, Jae-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.2
    • /
    • pp.68-73
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the effect of closed kinetic chain exercise using EMG-biofeedback for selective training of the vastus medialis oblique on functional ability and Q-angle in subjects with patellofemoral pain syndrome. Methods: Thirty participants who met the criteria were included in this study. Participants were randomly allocated to the control group (Group I, n=10), closed kinetic chain exercise group (Group II, n=10), and closed kinetic chain exercise using EMG-biofeedback group (Group III, n=10). Intervention was performed in three groups, three times per week, for a period of six weeks. Kujala patellofemoral score and Q-angle were measured before and after the experiment. Results: Some significant differences in kujala patellofemoral score were observed in group II and group III, compared with group I (p<0.01). There was no significant difference on in Q-angle at knee flexion angle $0^{\circ}$. However, some significant differences in Q-angle at knee flexion $60^{\circ}$ were observed in group III, compared with group I (p<0.01). Conclusion: Closed kinetic chain exercise using EMG-biofeedback that provides real-time biometric information on selected muscles in order to increase the efficiency of treatment may be helpful in improvement of functional ability and Q-angle in patellofemoral pain syndrome.

Design Parameter Analysis on the Performance and Noise of Axial Fan (축류형 홴 성능 및 소음에 영향을 미치는 설계변수 분석)

  • 김기황;이승배;주재만
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.275-281
    • /
    • 2001
  • While basic input parameters for the performance and noise of axial fan are flow rate, pressure rise, rotating speed, and fan diameter, the geometric parameters of blade are sweep angle, solidity, and camber angle. The sweep angle does not affect fan performance much, but on fan noise significantly. Solidity and camber angle are very critical design parameters acting on the fan performance directly. The solidity and camber angle are closely related, therefore they have to be carefully determined for the low-noise and high-performance fan. In This paper, different design points are selceted and also geometric parameters are deliberately changed for the comparison of fan noise. As a result, at the same performance, the input rotational speed affects radiated noise more significantly than others. When solidity and camber angle are increased more than those by iDesignFan/sup TM/ program, more noise is experienced. The blade sweep method and blade numbers at same solidity are observed to results in different levels of performance and noise.

  • PDF

The Effects of Evjenth-Hamberg Stretching on Active Range of Motion of the Hip Joint and the Pennation Angle (에비안스-함베르크 스트레칭 방법이 고관절의 능동 가동범위와 우모각에 미치는 영향)

  • Chon, Seung-Chul;Chang, Ki-Yeon
    • Physical Therapy Korea
    • /
    • v.17 no.2
    • /
    • pp.43-50
    • /
    • 2010
  • The purpose of this study was to investigate the effects of Evjenth-Hamberg stretching on the active range of motion (ROM) of the hip joint and the pennation angle of the semitendinosus muscle. Eighty healthy adults participated in this study. The active ROM of the hip joint was measured by a goniometer and the pennation angle of the semitendinosus muscle was measured by ultrasonographic imaging (USI). Both ROM and pennation angle were recorded before and after the static stretching and the Evjenth-Hamberg stretching, respectively. Data were analyzed using paired t-lest and independent t-test at p<.05. The results were as follows: 1) The active ROM of the hip joint increased significantly after both stretching interventions compared with the baseline (p<.001). However, the active ROM of the hip joint increased significantly in Evjenth-Hamberg stretching compared with static stretching. 2) The pennation angle decreased significantly after both stretching interventions compared with the baseline (p<.001). However, the pennation angle decreased significantly in Evjenth-Hamberg stretching compared with static stretching. 3) Reliability data showed that there was a high consistency in USl measurements (ICC=.978). Our findings suggest that the Evjenth-Hamberg stretching was more effective than static stretching in increasing the active ROM of the hip joint and decreasing the pennation angle of the semitendinosus muscle.