• 제목/요약/키워드: angle

검색결과 24,697건 처리시간 0.058초

요추 전만 각도와 요통 경향성의 상관관계에 대한 연구 (The study of relationship between lumbar lordotic angle and low back pain patterns)

  • 김세준;김신웅;정재현;김민영;최영일;조태영
    • 척추신경추나의학회지
    • /
    • 제8권1호
    • /
    • pp.15-26
    • /
    • 2013
  • Objectives: The purpose of this study is to find out the relationship between lumbar lordotic angle and low back pain patterns. Methods: We randomly selected the 1191 patients (595 males, 596 females) who have visited Bu-Chun Jaseng Hospital of Korean Medicine with low back pain. We have taken lumbar x-ray films and measured their lumbar lordotic angle, the angle formed between L1 superior margin and S1 superior margin. We investigated 1191 patients' low back pain patterns(date of occurence, existence of radiating pain, trend of increasing pain with lumbar extention and flexion, trend of increasing pain with standing and sitting positions) and analysed the relationship between lumbar lordotic angle and low back pain patterns. Results: 1. The lumbar lordotic angle of the acute phase patient is more straight than the chronic one. 2. The lumbar lordotic angle of the patients with radiating pain is more straight than the patients without radiating pain. 3. At acute phase, the lumbar lordotic angle of the patients with increasing pain from lumbar extention is more straight than those with increasing pain from lumbar flexion. 4. At chronic phase, the lumbar lordotic angle of the patients with increasing pain from lumbar flexion is more straight than those with increasing pain from lumbar extention. Conclusions: There was a significant correlation between lumbar lordotic angle and low back pain.

  • PDF

청소년 특발성 척추 측만증 환자를 위한 보정웨어가 측만각도와 보행 시 몸통과 골반의 중심이동에 미치는 영향 (Effects of the Functional Garment Wear on Cobb's Angle and COM of Trunk and Pelvic during Gait for Adolescent Idiopathic Scoliosis Patients)

  • 박양선;임영태
    • 한국운동역학회지
    • /
    • 제24권3호
    • /
    • pp.269-275
    • /
    • 2014
  • The purpose of this study is to develop functional garment wear for patients with adolescent idiopathic scoliosis (AIS) and to analyze changes in Cobb's angle and the COM of the body and the pelvis during gaits in order to identify the effects of the functional garment wear. The subjects of the study were 9 patients with adolescent idiopathic scoliosis, who wore the functional garment wear for 12 weeks 12 hours a day. As for the research methods, the scoliotic angle was measured using Cobb's angle, and the shoulder angle and the COM of the body and the pelvis during gaits for the AIS patients were calculated using five high speed infrared cameras. As a result of the study, it was found that the scoliotic angle (Cobb's angle) was reduced significantly and that the smaller the original scoliotic angle, the greater the effects. As for the shoulder motion angle, a significantly larger angle was found 12 weeks after wearing the functional garment wear, and particularly, larger shoulder motion (activity) was observed at the phase of right heel contact. As for the motion of the body and the pelvis, the moving ranges were significantly reduced after wearing the functional garment wear for 12 weeks, which stabilized gait in the patients with adolescent idiopathic scoliosis.

하악전돌증 환자에서 악교정수술 후 하악각 및 하악폭경의 변화 (CHANGES IN GONIAL ANGLE AND MANDIBULAR WIDTH AFTER ORTHOGNATHIC SURGERY IN MANDIBULAR PROGNATHIC PATIENTS)

  • 김인호;한창훈;유선열
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권2호
    • /
    • pp.129-137
    • /
    • 2006
  • The treatment plan for orthognathic surgery must be based on accurate predictions, and this can be produced the most esthetic, functional and stable results. The purpose of this study was aimed to evaluate the amount and interrelationship of the gonial angle and the mandibular width change after the mandibular setback surgery in the mandibular prognathic patients. Twenty patients were selected who received orthognathic surgery after presurgical orthodontic treatment. The patients with skeletal and dental Class III malocclusion were operated upon with bilateral sagittal split ramus osteotomy and mandibular setback. The lateral and posteroanterior cephalometric radiographs were taken preoperatively, postoperative 1 day and 12 months later after the orthognathic surgery, and then the gonial angle and mandibular width were measured. The computerized statistical analysis was carried out with SPSS/PC program. The gonial angle at postoperative 1 day was decreased about $5.3^{\circ}$ than preoperative value and the gonial angle at postoperative 12 months was increased about $1.4^{\circ}$ than postoperative 1 day. So the gonial angle at postoperative 12 months was decreased about $3.9^{\circ}$ than preoperative value. The mean preoperative gonial angle was $125.35^{\circ}{\pm}7.36$, showing significantly high value than normal and mean gonial angle at postoperative 12 months was $121.45^{\circ}{\pm}6.81$, showing value near to normal. The mandibular width at postoperative 1 day was decreased about 1.1 mm than preoperative value and the mandibular width at postoperative 12 months was more decreased about 1.7 mm than postoperative 1 day. So the mandibular width at postoperative 12 months was decreased about 2.8 mm than preoperative value. These results indicate that sagittal split ramus osteotomy in mandibular prognathic patients with high gonial angle is effective to improvement of gonial angle. It is considered to be helpful for maintenance of postoperative stable gonial angle area that detailed postoperative care and follow-up.

측정방법에 따른 흡기포트 분사식 다공 가솔린인젝터의 분무각 비교 (Comparison of Spray Angles of Multihole Port Fuel Gasoline Injector with Different Measuring Methods)

  • 김재호;임정현;노수영;문병수
    • 한국분무공학회지
    • /
    • 제5권3호
    • /
    • pp.17-26
    • /
    • 2000
  • The main parameter commonly used to evaluate spray distribution is spray angle. Spray angle is important because it influences the axial and radial distribution of the fuel. Spray angles were measured and compared for the two non-air assisted injectors such as 2hole-2stream 4hole-1stream injectors used for port fuel injection gasoline engines with n-heptane as a fuel by three different measuring techniques, i.e., digital image processing, shadowgraphy, and spray patternator, respectively. Fuel was injected with the injection pressures of 0.2-0.35 MPa into the room temperature and atmospheric pressure environment. In digital image processing approach, the selection of the transmittance level is critical to obtain the edge of spray and hence to measure the spray angle. From the measurement results by the shadowgraphy technique, it is dear that the spray angle is varied during the spray injection period. The measurement results from spray patternator show that the different spray angles exist in different region. Spray angle increases with the increase in the injection pressure. it is suggested that the spray angle and stream separated angle should be specified when spray is characterized for 2hole-2stream injector, because spray angle is much different though stream separated angle is same. It was also considerably affected by the measurement techniques introduced in this experimental work. However, the optimal axial distance for measuring the spray angle seems to be at least 60-80 mm from the injector tip for two non-air assisted injectors.

  • PDF

정상인의 팔굽, 무릎관절의 형태와 내.외반의 각도 및 무릅관절 간의 길이에 대한 조사 (A Study about the Type of Cubits.Genu Angle and the Distance of both Knee Joint in General)

  • 김근조;이규리;전제균
    • 대한물리치료과학회지
    • /
    • 제1권2호
    • /
    • pp.289-299
    • /
    • 1994
  • This study was researched the general characteristics, the elbow-knee joint form, the varus and valgus angle and the both knee joint distance of the 215 persons form July 1, 1994 to July 15, 1994. The results were as follows : 1. The form of elbow joint was significant statistically in the sex group(p<0.05). 2. The angle of elbow joint was very significant statistically in the age group and sex. B.M.I. group(p<0.001, p<0.01, p<0.01), and the average angle was $9^{\circ}.51{\pm}4^{\circ}.79$(n=215). 3. The angle of Cubitus valgus was very significant statistically in the age group(p<0.001), and the average angle of Cubitus valgus was $10^{\circ}.85{\pm}3^{\circ}.76$(n=187). 4. The angle of Knee joint was significant statistically in the age group(p<0.05), and the its average angle was $7^{\circ}.63{\pm}4^{\circ}.52$(n=215). 5. The angle of Genu varus was significant statistically in the age and sex group(p<0.05, p<0.05), and the its average was $6^{\circ}.92{\pm}2^{\circ}.36$(n=27). 6. The angle of Genu valgus was very significant statistically in the age group(p<0.001), and the its average angle was $9^{\circ}.75{\pm}2^{\circ}.94$(n=149). 7. The distance of both Knee joint was significant statistically in the age group and B. M. I. group (p<0.001, p<0.05), and the its average distance was $2.55{\pm}1.45cm$(n=135).

  • PDF

직경 및 문합각도가 단측 문합의 컴플라이언스 및 응력분포에 미치는 영향 (The Effect of the Diameter and Anastomotic Angle on the Compliance and the Stress Distribution of the End-to-side Anastomosis.)

  • 한근조;김영호
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.183-188
    • /
    • 1998
  • 동맥과 PTFE 재료로 된 대체혈관이 혈관폐색이 생긴 부위를 우회하기 위하여 단측문합이 되었을 때 문합각의 변화에 의한 영향을 살펴보기 위하여 두 혈관의 직경비를 0.5로 고정하고 문합각을 30$^{\circ}$에서 90$^{\circ}$까지 $10^{\circ}$간격으로 변화시켜 컴플라이언스와 응력의 분포형태를 살펴보고 또한 직경비의 영향도 살펴보기 위하여 문합각을 45$^{\circ}$로 고정하고 직경비를 0.1에서 1까지 0.1간격으로 변화시켜 컴플라이언스와 응력의 변화를 살펴보았다. 단측문합비에 사용된 모델은 20-24mm, 내경 4mm, 두께 0.5mm의 동맥과 길이 10mm, 내경 2mm, 두께 0.2mm의 PTFE 대체혈관이 사용되었으며 문합각이 작아지거나 직경비가 커질수록 예각 문합부의 컴플라이언스가 점점 더 커진다는 것을 알았다.

  • PDF

Evaluation of skeletal maturity in the cervical vertebrae and hand-wrist in relation to vertical facial types

  • Lee, Ye-Seul;Choi, Sung-Hwan;Kim, Kyung-Ho;Hwang, Chung-Ju
    • 대한치과교정학회지
    • /
    • 제49권5호
    • /
    • pp.319-325
    • /
    • 2019
  • Objective: To evaluate differences in skeletal maturity in relation to vertical facial types and to compare differences in the skeletal maturity of the cervical vertebrae and hand-wrist in females. Methods: This study included 59 females aged 7 to 9 years with skeletal Class I malocclusion. The participants were categorized into three groups (low, normal, and high) according to the mandibular plane angle. Skeletal maturity was measured using skeletal maturity indicators (SMIs) and the Tanner-Whitehouse III (TW3) method on hand-wrist radiographs and by using cervical vertebrae maturation indicators (CVMIs) on lateral cephalometric radiographs. Results: The SMI was higher in the high-angle group than in the low-angle group (p = 0.014). The median TW3 bone age was 11.4 months higher in the high-angle group than in the low-angle group (p = 0.032). There was no significant difference in CVMI among the three groups. Skeletal maturity showed a weakly positive correlation with the mandibular plane angle (SMI, r = 0.391; TW3, r = 0.333; CVMI, r = 0.259). Conclusions: The skeletal maturity of the hand-wrist in females with a high mandibular plane angle was higher than that in females with a low mandibular plane angle. Obtaining additional hand-wrist radiographs may facilitate evaluation of skeletal maturity of females. In females with a high mandibular angle, the time to commence orthodontic treatment may be earlier than that in females with a low mandibular angle.

The Vortical Flow Field of Delta Wing with Leading Edge Extension

  • Lee, Ki-Young;Sohn, Myong-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제17권6호
    • /
    • pp.914-924
    • /
    • 2003
  • The interaction and breakdown of vortices over the Leading Edge Extension (LEX) - Delta wing configuration has been investigated through wing-surface pressure measurements, the off-surface flow visualization, and 5-hole probe measurements of the wing wake section. The description focused on analyzing the interaction and the breakdown of vortices depending on the angle of attack and the sideslip angle. The Effect of angle of attack and sideslip angle on the aerodynamic load characteristics of the model is also presented. The sideslip angle was found to be a very influential parameter of the vortex flow over the LEX-delta wing configuration. The introduction of LEX vortex stabilized the vortex flow, and delayed the vortex breakdown up to a higher angle of attack. The vortex interaction and breakdown was promoted on the windward side, whereas it was suppressed on the leeward side.

The Immediate Effects of Five-Toed Shoes on Foot Structure

  • Yi, Kyung-Ock
    • 한국운동역학회지
    • /
    • 제21권4호
    • /
    • pp.397-403
    • /
    • 2011
  • The purpose of this study is to analyze the immediate effects of five toed shoes on foot structure. Subjects consisted of 26 college-aged women with pes planus. X-ray analysis of student feet were performed both barefooted and with five toed shoes. Dependent variables were hallux valgus angle, calcaneal inclination angle, 1st metatarsal declination angle, and intermetartarsal angle. Independent t-test was used for statistical analysis along with SAS. Overall, there were statistically significant changes of test subject's dependent variables when wearing five toed shoes. Specifically, the hallux valgus angle decreased, the calcaneal inclination angle and 1st metatarsal inclination angle increased, and intermetatasal angles both increased and decreased, shifting towards normal range. In every case the dependent variables shifted towards a more normal range while subjects wore five toed shoes. This study only examined the immediate corrective effects of five toed shoes on foot structure, but long-term studies are needed to understand the prolonged effects of five toed shoes on foot structure.

Initial Firing Angle Control of Parallel Multi-Pulse Thyristor Dual Converter for Urban Railway Power Substations

  • Kim, Sung-An;Han, Sung-Wo;Cho, Yun-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.674-682
    • /
    • 2017
  • This paper presents an optimal initial firing angle control based on the energy consumption and regenerative energy of a parallel multi-pulse thyristor dual converter for urban railway power substations. To prevent short circuiting the thyristor dual converter, a hysteresis band for maintaining a zero-current discontinuous section (ZCDS) is essential during mode changes. During conversion from the ZCDS to forward or reverse mode, the DC trolley voltage can be stabilized by selecting the optimal initial firing angle without an overshoot and slow response. However, the optimal initial firing angle is different depending on the line impedance of each converter. Therefore, the control algorithm for tracking the optimal initial firing angle is proposed to eliminate the overshoot and slow response of DC trolley voltage. Simulations and experiments show that the proposed algorithm yields the fastest DC voltage control performance in the transient state by tracking the optimal firing angle.