• Title/Summary/Keyword: angle

Search Result 24,777, Processing Time 0.059 seconds

Correction of positional change of frontal cephalometric landmarks caused by vertical head rotation (두부의 수직회전 시 정모두부방사선사진상의 계측점 변화와 이의 보정)

  • Kim, Mi-Young;Lee, Kyung-Min;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.98-111
    • /
    • 2011
  • Objective: Superimposition of frontal cephalograms cannot be performed when the cephalograms are taken with different vertical head rotations. The purpose of the present study was to evaluate the validity of correcting the positional change of frontal cephalometric landmarks caused by vertical head rotation. Methods: In 30 adult individuals, frontal and lateral cephalograms were taken at a $90^{\circ}$ angle. Geometric principles of radiography were used to calculate the possible vertical and horizontal landmark changes if the head should be rotated down $5^{\circ}$ about an ear rod axis. The calculated changes were then compared with cephalometric changes measured on frontal cephalogram actually taken with the head rotated down $5^{\circ}$. Results: When the frontal cephalograms were taken with the head rotated down $5^{\circ}$ about an ear rod axis, significant changes in the vertical position of the landmarks occurred, particularly in the landmarks located farther anteriorly from the ear rod axis. The comparison of calculated changes and real cephalometric changes showed that the differences were less than 0.4 mm in the vertical direction and less than 0.2 mm in the horizontal direction. The differences between calculated and real changes were smaller in the landmarks less affected by vertical head rotation. Conclusions: Even when frontal cephalograms are taken at different vertical head rotations, the concomitant changes in the position of the landmarks can be corrected through calculation using the geometric principle of radiography as long as frontal and lateral cephalograms are taken perpendicular to each other.

A Comparison of Outcomes after Early and Delayed Reconstruction in the Acute Posterior Cruciate Ligament Injuries (급성 후방십자인대 손상 환자에서 조기 재건군과 지연 재건군의 결과 비교)

  • Lee, Yong Sik;Lee, Soo Won;Seo, Byung Ho;Kim, Yoon Gi
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.31-37
    • /
    • 2013
  • Purpose: This study performed to compare degree of joint stiffness and clinical results between early and delayed reconstruction of acute posterior cruciate ligament (PCL) injuries. Materials and Methods: Thirty-two Patients who underwent PCL reconstruction between March 2008 and October 2011 enrolled this study. We performed transtibial single bundle reconstruction using the allo-achilles tendon in all cases. We divided the patient into two groups, early reconstruction group underwent surgery before a week, delayed reconstruction group underwent surgery after 3 weeks, before 6 weeks. All the patients underwent aggressive joint motion exercise till surgery and enrolled post operative rehabilitation program. We checked posterior drawer stress radiography, range of motion, the Lysholm score, the International Knee Documentation Committee (IKDC) score and the Tegner score to evaluate the results. Results: At the final follow up the Lysholm score was 92.1 in the early group and 93.8 in the delayed group. All the cases were rated above B (near normal) on IKDC score (p=0.808, p=0.722). The Tegner score was 6.6 in the early reconstruction group and 6.2 in the delayed group (p=0.480), The average of maximum flexion and extension angle was $133.9^{\circ}$, $1.4^{\circ}$ in the early group and $133.6^{\circ}$, $1.1^{\circ}$ in the delayed group (p=0.560, p=0.581), no complication such as deep vein thrombosis or infection, no difference in posterior drawer stress radiography (p=0.750). Conclusion: We could obtain satisfactory clinical results in both the early and delayed reconstruction groups of acute PCL injuries. Therefore, the early reconstruction of PCL performed before a week could be one of the treatment options for acute PCL injury.

  • PDF

Matching Points Filtering Applied Panorama Image Processing Using SURF and RANSAC Algorithm (SURF와 RANSAC 알고리즘을 이용한 대응점 필터링 적용 파노라마 이미지 처리)

  • Kim, Jeongho;Kim, Daewon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.144-159
    • /
    • 2014
  • Techniques for making a single panoramic image using multiple pictures are widely studied in many areas such as computer vision, computer graphics, etc. The panorama image can be applied to various fields like virtual reality, robot vision areas which require wide-angled shots as an useful way to overcome the limitations such as picture-angle, resolutions, and internal informations of an image taken from a single camera. It is so much meaningful in a point that a panoramic image usually provides better immersion feeling than a plain image. Although there are many ways to build a panoramic image, most of them are using the way of extracting feature points and matching points of each images for making a single panoramic image. In addition, those methods use the RANSAC(RANdom SAmple Consensus) algorithm with matching points and the Homography matrix to transform the image. The SURF(Speeded Up Robust Features) algorithm which is used in this paper to extract featuring points uses an image's black and white informations and local spatial informations. The SURF is widely being used since it is very much robust at detecting image's size, view-point changes, and additionally, faster than the SIFT(Scale Invariant Features Transform) algorithm. The SURF has a shortcoming of making an error which results in decreasing the RANSAC algorithm's performance speed when extracting image's feature points. As a result, this may increase the CPU usage occupation rate. The error of detecting matching points may role as a critical reason for disqualifying panoramic image's accuracy and lucidity. In this paper, in order to minimize errors of extracting matching points, we used $3{\times}3$ region's RGB pixel values around the matching points' coordinates to perform intermediate filtering process for removing wrong matching points. We have also presented analysis and evaluation results relating to enhanced working speed for producing a panorama image, CPU usage rate, extracted matching points' decreasing rate and accuracy.

A Development of Tapered Metallic Microneedle Array for Bio-medical Application (생체의학에 적용 가능한 테이퍼형태의 금속성 마이코로니들 어레이의 개발)

  • Che Woo Seong;Lee Jeong-Bong;Kim Kabseog;Kim Kyunghwan;Jin Byung-Uk
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.2 s.31
    • /
    • pp.59-66
    • /
    • 2004
  • This paper presents a novel fabrication process for a tapered hollow metallic microneedle array using backside exposure of SU-8, and analytic solutions of critical buckling of a tapered hollow microneedle. An SU-8 meta was formed on a Pyrex glass substrate and another SU-8 layer, which was spun on top of the SU-8 mesa, was exposed through the backside of the glass substrate. An array of SU-8 tapered pillar structures. with angles in the range of $3.1^{\circ}{\sim}5^{\circ}$ was formed on top of the SU-8 mesa. Conformal electrodeposition of metal was carried out followed by a mechanical polishing using a pianarizing polymeric layer. All organic layers were then removed to create a metallic hollow microneedle array with a fluidic reservoir on the backside. Both $200{\mu}m\;and\;400{\mu}m$ tall, 10 by 10 arrays of metallic microneedles with inner diameters of the tip in the range of $33.6{\sim}101\;{\mu}m$ and wall thickness of $10{\mu}m\;-\;20{\mu}m$ were fabricated. Analytic solutions of the critical buckling of arbitrary-angled truncated cone-shaped columns are also presented. It was found that a single $400{\mu}m$ tall hollow cylindrical microneedle made of electroplated nickel with a wall thickness of $20{\mu}m$, a tapered angle of $3.08^{\circ}$ and a tip inner diameter of $33.6{\mu}m$ has a critical buckling force of 1.8 N. This analytic solution can be used for square or rectangular cross-sectioned column structures with proper modifications.

  • PDF

Evaluation of Setup Errors for Tomotherapy Using Differently Applied Vacuum Compression with the Bodyfix Immobilization System (토모테라피 치료 시 Bodyfix System에서 진공압박에 따른 환자 위치잡이오차(Setup errors)의 평가)

  • Jung, Jae-Hong;Cho, Kwang-Hwan;Lee, Jeong-Woo;Kim, Min-Joo;Lim, Kwang-Chae;Moon, Seong-Kwon;Kim, Yong-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.72-78
    • /
    • 2011
  • The aim of this study is to evaluate the patient's setup errors in TomoTherapy (Hi-Art II, TomoTherapy, USA) Bodyfix system (Medical Intelligence, Ele-kta, Schwabmuchen, Germany) pressure in the vacuum compression, depending on and were evaluated. Bodyfix immobilization system and vacuum pressure was compression applied to the patients who received Tomotherapy thoracic and abdominal area, 21 patients were selected and TomoTehpay treatment total 477 of MVCT images were obtained. The translational (medial-lateral: ML, anterior-posterior: AP, superior-inferior: SI directions) and rolling were recorded and analyzed statistically. Using Pearson's product-moment coefficient and One-way ANOVA, the degree of correlation depending on the different vacuum pressure levels were statistically analyzed for setup errors from five groups (p<0.05). The largest average and standard deviation of systematic errors were 6.00, 5.95 mm in the AP and SI directions, respectively. The largest average of random errors were 4.72 mm in the SI directions. The correlation coefficients were 0.485, 0.244, and 0.637 for the ML-Roll, AP-Vector, and SI-Vector, respectively. SI-Vector direction showed the best relationship. In the results of the different degree of vacuum pressure in five groups (Pressure range: 30~70 mbar), the setup errors between the ML, SI in both directions and Roll p=0.00 (p<0.05) were shown significant differences. The average errors of SI direction in the vacuum pressure of 40 mbar and 70 mbar group were 4.78 mm and -0.74 mm, respectively. In this study, the correlation between the vacuum pressure and the setup-errors were statistically analyzed. The fact that setup-errors in SI direction is dependent in vacuum pressure considerly setup-errors and movement of interal organs was identified. Finally, setup-errors, and it, based on the movement of internal organs in Bodyfix system we should apply more than 50 mbar vacuum pressure. Based on the results of this study, it is suggested that accuracy of the vacuum pressure and the quantitative analysis of movement of internal organs and the tumor should be studied.

A Methodology of Ship Detection Using High-Resolution Satellite Optical Image (고해상도 광학 인공위성 영상을 활용한 선박탐지 방법)

  • Park, Jae-Jin;Oh, Sangwoo;Park, Kyung-Ae;Lee, Min-Sun;Jang, Jae-Cheol;Lee, Moonjin
    • Journal of the Korean earth science society
    • /
    • v.39 no.3
    • /
    • pp.241-249
    • /
    • 2018
  • As the international trade increases, vessel traffics around the Korean Peninsula are also increasing. Maritime accidents hence take place more frequently in the southern coast of Korea where many big and small ports are located. Accidents involving ship collision and sinking result in a substantial human and material damage as well as the marine environmental pollution. Therefore, it is necessary to locate the ships quickly when such accidents occur. In this study, we suggest a new ship detection index by comparing and analyzing the reflectivity of each channel of the Korea MultiPurpose SATellite-2 (KOMPSAT-2) images of the area around the Gwangyang Bay. A threshold value of 0.1 is set based on a histogram analysis, and all vessels are detected when compared with RGB composite images. After selecting a relatively large ship as a representative sample, the distribution of spatial reflectivity around the ship is studied. Uniform shadows are detected on the northwest side of the vessel. This indicates that the sun is in the southeast, the azimuth of the actual satellite image is $144.80^{\circ}$, and the azimuth angle of the sun can be estimated using the shadow position. The reflectivity of the shadows is 0.005 lower than the surrounding sea and ship. The shadow height varies with the position of the bow and the stern, perhaps due to the relative heights of the ship deck and the structure. The results of this study can help search technology for missing vessels using optical satellite images in the event of a marine accident around the Korean Peninsula.

Influence of bearing surface angle of abutment screw on mechanical stability of joint in the conical seal design implant system (내부 원추형 연결형태 임플란트에서 지대주 나사머리의 좌면각도가 연결부 기계적 안정성에 미치는 영향)

  • Kim, Joo-Hyeun;Huh, Jung-Bo;Yun, Mi-Jung;Kang, Eun-Sook;Heo, Jae-Chan;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.206-214
    • /
    • 2014
  • This study is to evaluate how different bearing surface angles of abutment screw affect the mechanical stability of the joint in the conical seal design implant system. Materials and Methods: Internal connection type regular implants, two-piece cemented type abutments and tungsten carbide/carbon-coated titanium alloy abutment screws were selected. Titanium alloy screws with conical ($45^{\circ}$) and flat ($90^{\circ}$) head designs which fit on to abutment were fabricated. The abutments were tightened to implants with 30 Ncm by digital torque gauge. The loading was applied once to the central axis of abutment. The mean axial displacement was measured using micrometer before and after the tightening and loading (n = 5). The abutment was tightened to implants with 30 Ncm and T-shape stainless steel crown was cemented. Then the change in the amount of reverse-torque was measured after the repeated loading to the central axis, and the place 5 mm away from the central axis. Compressive bending and fatigue strength were measured at the place 5 mm away from the central axis (n = 5). Results: Both groups showed the largest axial displacement when abutment screw tightening and total displacement was greater in the flat head group compared to conical head group (P < 0.05). However, there were no significant differences in reverse torque value, compressive bending and fatigue strength (P > 0.05). Conclusion: Within the limitations of this study, the abutment screw head design had no effect on two groups regarding the joint stability, however the conical head design affected the settlement of abutment resulting in the reduced total displacement.

The Clinical Usefulness of Cephalometric Analysis in the Obstructive Sleep Apnea Syndrome (폐쇄성 수면 무호흡 증후군에서 두개골계측분석의 임상적 유용성)

  • Choi, Young-Mee;Lee, Sang-Haak;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.2
    • /
    • pp.218-230
    • /
    • 1999
  • Background: Craniofacial anatomic abnormalities related to structural narrowing of the upper airway have been reported in patients with obstructive sleep apnea syndrome. In this study, we evaluated the craniofacial anatomic characteristics of Korean patients with obstructive sleep apnea syndrome, and the role of cephalometric analysis in the prediction of abnormal breathing during sleep. Methods: Thirty-nine patients with obstructive sleep apnea syndrome(OSAS), 39 simple snorers(simple snorers) and 20 controls(control) had cephalometric analysis using the technique of Riley et al, and underwent standardized polysomnographic recordings. Different variables, including sex, body mass index, cephalometric and polysomnographic data, were statistically analyzed. Results: Pm-UPW and V-LPW distances were significantly shorter in OSAS when compared with simple snorers or control. PAS in simple snorers was shorter than in control. ANS-Gn distance in OSAS was significantly longer than in control. PNS-P distance in OSAS or simple snorers was significantly longer than in control. MP-H distance in OSAS was significantly longer than in simple snorers or control and MP-H distance in simple snorers was also longer than in control. NL/Pm-P angle in OSAS was lesser than in control. MP-H distance in OSAS or in the combined groups of OSAS and simple snorers was significantly correlated with apneahypopnea index(AHI). PNS-P distance in the combined groups of OSAS and simple snorers was correlated with AHI. In male of all subjects, body mass index was significantly correlated with PNS-P or MP-H distance. Conclusion: Cephalometric analysis can be useful tool in determining the craniofacial anatomic abnormalities in patients with obstructive sleep apnea syndrome. Cephalometric parameters, especially MP-H distance, can be useful for predicting frequency of narrowing or obstruction of upper airway during sleep.

  • PDF

The moment generated by the torque of the orthodontic rectangular wire : Three-dimensional finite element analysis (교정용 각형선재에 부여된 torque가 브라켓에 발생시키는 모멘트에 관한 유한요소법적 분석)

  • Ha, Do-Won;Kim, Young-Suk;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.335-346
    • /
    • 2001
  • The purpose of this study was to investigate the ideal clinical torque(In the SWA rectangular wire, the torque by the angle between the plane part and twisted part to move the tooth) of the orthodontic rectangular wire which produce the proper labiolingual movement of the single tooth during finishing stage of the orthodontic treatment. The clinical torque is the sum of the play and the active torque which generates the moment at the bracket. The play is calculated by the formula and the active torque is calculated by the computer aided three-dimensional finite element method. The finite element model was consist of the three brackets which formed a row and 3 kinds of orthodontic rectangular wire(stainless steel, TMA, NiTi) which inserted in brackets. Both sides of the model were twisted and the moment generated in the center bracket was calculated. The sizes of seven wires which were used commonly were .016'X.022', .017'X.022', .017'X.025', .018'X.025', .019'X.025', .020'X.025', .021'X.025'. In 018' bracket, 016'X.022', .017'X.022', .017'X.025' wires were inserted and in 022' bracket, all the sizes of wires except .016'X.022' were inserted and tested. The following conclusions could be drawn from this study. 1. The moments generated on the same size of the wires by the same active torque were equal regardless of the bracket slot size. 2. The moments were increased with the size of the wires. The moment generated on the .021'X.025' wire was about 1.75 times as large as that on the .016'X.022' wire regardless of the material. 3. The moments were increased in the order of the NiTi, TMA stainless steel. The moment of the TMA wire was 0.35 times as small as that of the stainless steel wire and the moment of the NiTi was0.16 times as small as that of the stainless steel wire. 4. The moment was decreased as the interbracket distance was increased. 5. To get a desired moment with the specific size and material of the wire on the specific bracket slot, the formula and the results were displayed.

  • PDF

A STUDY OF THE SECOND MOLAR WHICH WAS MALPOSITIONED AFTER ORTHODONTIC TREATMENT (교정치료후 부정위치된 제2대구치의 양상에 관한 연구)

  • Yun, Young-Sun;Lee, Dong-Joo
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.299-310
    • /
    • 1995
  • The purpose of this study is to know about the positional change of second molar when orthodontic treatment is performed. To know about it, we andlysed cephalogram pre. and post treatment for 54 adult patients who werefinished orthodontic treatment by banding to the first molar and classify them into 4 groups Class I extraction group 15, Class I nonextraction group 12, Class II group 13, class Class III group 14. The following conclusions were obtained : 1. In the extraction group of Class I , mandibular second molar showed less extrusion and mon distal inclination than first moarl. But maxillary second molar showed more or less extrusive and mesial inclination to much the same degree of first molar. 2. Inthe non-extractio group of Class I, mandibular second molar in intrusive to first molar, it showed smilar distal inclination to first molar. But maxillary second molar is extrusive similarly to first molar. 3. In the group of Class II , mandibular second molar is less extrusive than first molar and maxillary second molar is more extrusive than first molar. 4. In the group of Class III, mandibular second molar showed similar extrusion to first molar and more distal inclination than first molar. But maxillary second molar showed less extrusion than first molar. 5. A comparision of the positional change of second molar among groups : The change of distance from FH plane to funcation point of maxillary second molar is the difference between Class I extraction group and Class II group, Class I extraction group and Class III group. The change of maxillary second molar to palatal plane and occlusal plane is the difference between Class I extraction group and Class III group. And the change of distance from mandibular plan to furcation point of mandibular second molar is difference between Class I extraction group and non-extraction group, Class I non-extraction group and Class II group, Class I non-extraction group and Class III group. But the change of angle of mandibular second molar to mandibular plane and occlusal plane is make no difference in among groups.

  • PDF