• Title/Summary/Keyword: and turbidity

Search Result 1,695, Processing Time 0.028 seconds

Effects of Gellan, Xanthan, and $\lambda$-Carrageenan on Ellagic Acid Sedimentation, Viscosity, and Turbidity of 'Campbell Early' Grape Juice

  • Ghafoor, Kashif;Jung, Ji-Eun;Choi, Yong-Hee
    • Food Science and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.80-84
    • /
    • 2008
  • The effect of gellan (GE), xanthan (XA), and $\lambda$-carrageenan (LC) on the viscosity, sedimentation, ellagic acid content, and turbidity of grape 'Campbell Early' juice (CEJ) was investigated. CEJ samples with 0.15% each of GE, XA, and LC were tested for the above variables after 0, 5, 10, and 20 days of storage. The samples containing GE (0.15%) showed the least amount of sediment formation, the lowest ellagic acid content and turbidity, and a rise in viscosity. Sedimentation in CEJ decreased with increased viscosity due to the addition of gums which also limited the ellagic acid content and turbidity. GE was the most effective additive for the stabilization of CEJ.

Effects of Main Shaft Velocity on Turbidity and Quality of White Rice in a Rice Processing System

  • Cho, Byeong-Hyo;Kang, Tae-Hwan;Won, Jin-Ho;Kang, Shin-Hyeong;Lee, Hee-Sook;Han, Chung-Su
    • Journal of Biosystems Engineering
    • /
    • v.42 no.1
    • /
    • pp.69-74
    • /
    • 2017
  • Purpose: The purpose of this study is to analyze turbidity and quality characteristics of white rice as a function of main shaft blast velocity and to verify the optimum processing conditions in the cutting type white rice processing system (CTWRPS). Methods: Sindongjin, one of the rice varieties, which used to be produced in Gimje-si, Jeollabuk-do, in 2015, was used as the experimental material. Turbidity and quality characteristics of white rice were measured at three different main shaft blast velocities: 25, 30, and 35 m/s. The amount of test material used for a single experiment was 20 kg, and after processing, whiteness was found to be $42.5{\pm}0.5$, following which, turbidity and quality characteristics were measured. Results: Turbidity decreased with increase in the shaft blast velocity, and as a result, was lowest at 35 m/s of shaft blast velocity among all the other experiment velocities. The trend of cracked rice ratios was similar to the turbidity. Broken rice ratio turned out to be less than 2.0% in all the test conditions. In the first stage of processing, the processing pressure decreased as the main shaft blast velocity increased. Additionally, in the second stage of processing, the processing pressure was at its lowest value at the main shaft blast velocity of 35 m/s. Energy consumption, too, decreased as the main shaft blast velocity was increased. Conclusions: From the above results, it is concluded that the main shaft blast velocity of 35 m/s is best for reducing turbidity and producing high quality rice in a CTWRPS.

Correlation Analysis of Reflectance and Turbidity through Spectral Characteristics of Near-Infrared (근적외선의 분광특성 분석을 통한 반사율과 탁도의 상관관계 분석)

  • Lee, So-Jin;Jeong, Gyo-Cheol;Lee, Chang-Ju;Kim, Jong-Tae
    • The Journal of Engineering Geology
    • /
    • v.32 no.1
    • /
    • pp.101-111
    • /
    • 2022
  • This study analyzed the relationship between water turbidity and its reflectance, as measured using hyperspectral imaging. First, samples of turbid water were generated in boxes. This was followed by drone-based hyperspectral imaging and analysis of the correlation between the samples' measured turbidity and hyperspectral reflectance. The nine boxes for turbidity measurement were made of black acrylic that absorbed all light turbidity was induced using soil collected near Changhacheon, which causes turbidity in Imha Lake. The results indicate that the reflectance of wavelengths in the near-infrared region followed a pattern of increase with increasing soil content for each box. Analysis of this correlation between the turbidity and average reflectance measured in each box yielded a very high R2 value of 0.8702, indicating that reflectance is a suitable proxy for turbidity.

A Study on the Application of a Turbidity Reduction System for the Utilization of Thermal Wastewater in High Turbidity Zones (고탁도 해역의 온배수 활용을 위한 탁도저감시스템 적용에 대한 연구)

  • Ha, Shin-Young;Oh, Cheol;Gug, Seung-Gi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.7
    • /
    • pp.916-922
    • /
    • 2018
  • Recently, power plant effluent condensers received a Renewable Energy Certificate as components of hydrothermal energy (weighted 1.5 times) as one target item of the Renewable Portfolio Standard (RPS) policy. Accordingly, more attention is being paid to the value of thermal wastewater as a heat source. However, for utilization of thermal wastewater from power plants in high-turbidity areas like the West Sea of Korea, a turbidity reducing system is required to reduce system contamination. In this study, an experimental test was performed over a month on thermal wastewater from power plants located in the West Sea of Korea. It was found that water turbidity was reduced by more than 80 % and that the concentration of organic materials and nutrient salts was partially reduced due to the reduction of floating/drifting materials. To conduct a comparative analysis of the level of contamination of the heat exchanger when thermal wastewater flows in through a turbidity reducing system versus when the condenser effluent flows in directly without passing through the turbidity system, we disassembled and analyzed heat exchangers operated for 30 days. As a result, it was found that the heat exchanger without a turbidity reducing system had a higher level of contamination. Main contaminants (scale) that flowed in to the heat exchanger included minerals such as $SiO_2$, $Na(Si_3Al)O_8$, $CaCO_3$ and NaCl. It was estimated that marine sediment soil flowed in to the heat exchanger because of the high level of turbidity in the water-intake areas.

Prediction of Alkaline Copper Quat (ACQ) Wood Preservative Concentration by Turbidity (탁도에 의한 구리·알킬암모늄화합물계 목재방부제(ACQ)의 농도 예측)

  • Lee, Jong Shin;Kim, Kyoung Tae;Choi, Gwang Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.743-749
    • /
    • 2016
  • The concentration control of wood preservatives is necessary to produce a preservative treated wood having a uniform quality. Concentration measurement method of wood preservatives to be easily used in the field has not been developed yet. This study examined the way to estimate the concentration from turbidity of ACQ wood preservative that can be relatively easily measured by using a portable turbidity meter. The addition of phosphoric acid solution in an alkaline ACQ solution having a very low turbidity is created a suspension of the white substance and the turbidity suddenly increased. The optimum amount of addition of the phosphoric acid solution is until the pH of ACQ solution reaches 7, the turbidity of the ACQ solution reaches maximum value. Excessive addition of the phosphoric acid solution results in a turbidity decrease with acidification of the ACQ solution. Also ACQ solution becomes transparent. The high significance was recognized with positive correlation between the concentration and the turbidity of the ACQ solution. From the t-test, The significant difference between the actually measured concentrations and the concentrations predicted by the regression equation for industrial ACQ solutions was not recognized. Thus, it was possible to know that concentration prediction and control of industrial ACQ solution using the turbidity and a regression equation. Therefore, using the regression equation and turbidity is expected to be able to management the concentration of ACQ solution in the industrial field.

Application of Horizontal Flow Fins Inclined Plate for Sedimentation Efficiencies Improvement in River Water with High Turbidity (고탁도 원수의 침전효율 증대를 위한 수평류식 핀 경사판 적용에 관한 연구)

  • Choi, Jung-Su;Jin, Oh-Suk;Joo, Hyun-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.644-650
    • /
    • 2012
  • The purpose of this study is to evaluate the applicability of Horizontal Flow Fins Inclined Plate (HFIP) for the removal of high-turbidity raw water in water treatment plant. As an experimental result, treated water quality and removal efficiency were 0.34 NTU and 90.45% by the application of HFIP for low-turbidity raw water and for the high-turbidity influent resulted 0.75 NTU and 97.27% in removal efficiency. In view of stability for discharge water NTU, the standard deviation were found as 0.12 NTU for low-turbidity and 0.75 NTU for high-turbidity raw water indicating low fluctuations. Result of flow analysis using CFD (Computational Fluid Dynamic) that the addition of HFIP improves the turbidity treatment followed by the stabilization of flow velocity distribution and increases in settling velocity.

Development of On-line Technology for Measuring Stock Consistency Using Optical Sensor (Part 1) - A study on the relationship between the turbidity and transmittance of stocks and their consistency - (광학센서를 이용한 지료의 농도 평가 기술 개발(제1보) - 펄프 슬러리 및 충전물 농도와 탁도 및 투과율의 상관관계 분석 -)

  • Lee Hak-Lae;Lee Ji-Young;Youn Hye-Jung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.1 s.113
    • /
    • pp.9-15
    • /
    • 2006
  • To develop an efficient and cost effective on-line method to determine the stock consistency a study on the relationship between the turbidity and transmittance of stocks and their consistency was carried out using a system consisted of a dynamic drainage jar, pump and turbidometer. Results shooed that the wavelength of 525 nm was most effective for measuring turbidity. As the consistency increases the turbidity increases, and their relationship can be depicted in the second order equations. On the other hand the relationship between consistency and transmittance can be described in exponential equations. From these equations the consistencies of stock samples can be determined using the measured values of turbidity or transmittance.

Development of On-line Technology for Measuring Stock Consistency Using Optical Sensor (Part 2) - Effect of stock properties on the relationship between the turbidity and transmittance of stocks and consistency - (광학센서를 이용한 지료의 농도 평가 기술 개발(제2보) - 펄프의 특성 변화가 농도와 탁도 및 투과율의 상관관계에 미치는 영향 -)

  • Lee Ji-Young;Youn Hye-Jung;Lee Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.1 s.113
    • /
    • pp.16-20
    • /
    • 2006
  • The effect of the freeness of pulp slurries on turbidity and transmittance of papermaking stocks was investigated using beaten bleached hardwood pulp stocks with freeness ranging from 651 mL to 403 mL CSF. Also the influence of fiber length on the turbidity and transmittance was examined with fractionated pulp stocks. Increases in stock consistency increased the turbidity. Transmittance of stock samples decreased, however, with the increase of stock consistency. Second order equations and exponential equations have been obtained as regression equations for the turbidity and transmittance of these stock samples, respectively.

Removal of NOM in a Coagulation Process Enhanced by Modified Clay (개질 Clay를 첨가한 응집공정에서의 자연유기물 제거)

  • Park, Ji-Hye;Lee, Sang-Yoon;Park, Hung-Suck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.37-46
    • /
    • 2007
  • A feasibility test was conducted to evaluate the addition of turbidity substance in a coagulation process to remove natural organic matters (NOM), the precursor of disinfection by-products (DBPs). The experimental water sources were synthetic water containing 5 mg/L of humic acid and 50 mg/L of NaHCO3 and drinking water resource of Ulsan city (S Dam water, D Dam water and Nak-Dong raw water). The examined turbidity substances were kaolin, acid clay, and modified clay (0.38 meq $NH_4{^+}-N/g$ clay). In Jar tests at different concentrations of the turbidity substances (5, 10, 15, 20, 30 mg/L) using the synthetic water, the turbidity substances improved the removal of turbidity, UV-254 absorbance and dissolved organic carbon (DOC) by 23.8-38.1%, 17.0-24.5% and 2.5-44.5%, respectively. The modified clay showed higher removal efficiencies than other substances. In Jar tests using the drinking water, 10 and 20 mg/L of modified clay enhanced the removal efficiencies of turbidity, UV-254 absorbance, DOC, trihalomethane formation potential (THMFP), and haloacetic acid formation potential (HAAFP) by 3.0~4.3%, 19.1~29.0%, 12~34.9%, 4.9~36.7%, and 1.6~30.2%, respectively.

Cause of Filtrate Deterioration and Its Improvement in Rapid Filtration (급속여과공정에서 여과수질 저하원인 및 개선방안)

  • Kim, Jin-Keun;Lee, Song-Hee;Kim, Jae-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.3
    • /
    • pp.333-339
    • /
    • 2010
  • Particle removal is an important step taken at water treatment plants (WTPs) for the safety of tap water due to its proportionality to the pathogen inactivation. Government promulgated a treatment technique for the optimization of filtration including continuous turbidity monitoring using on-line turbidimeters. Based on the turbidity measurements of 460 filters at 31 WTPs operated by K-water, the evaluation of filtration performance and the investigation of major causes related to particle breakthrough were explored. 98.1 % of the filters had an effluent turbidity measurement which was less than 0.1 NTU, but turbidity breakthrough of more than 0.3 NTU was noticed occasionally which is in violation of AWWA 5-Star guidelines. It was shown that the optimization of coagulation, filter-to-waste, the observance of optimal filtration velocity and backwashing process based on filtrate turbidity were crucial for the improvement of filtrate.