• 제목/요약/키워드: and turbidity

검색결과 1,695건 처리시간 0.029초

공정수에 존재하는 형광증백제의 제거 기술에 대한 기초연구 (Fundamental Study on Developing the Technology for the Removal of Fluorescent Whitening Agents from the Process Water)

  • 이지영;윤혜정;이학래
    • 펄프종이기술
    • /
    • 제41권1호
    • /
    • pp.24-29
    • /
    • 2009
  • The use of fluorescent whitening agents (FWAs) increases as the demand for the whiter and brighter printing papers increases. FWAs are used as internal and surface treatment chemicals. FWAs that are not used properly in the papermaking process, however, remain in the process water and may demage the paper quality and processes. In this study, a new idea to eliminate FWAs from the process water, consisted of the floc formation of FWAs with cationic chemicals, such as cationic polyelectrolytes and alum, and the removal of the floc by screening or sedimentation, was proposed. Flocculation of FWAs, that is the first step to remove FWAs from the process water, was investigated using turbidity and particle size measurement. Relationship between turbidity and particle size showed that the turbidity could reflect the particle size change of FWA flocs and was proper for the evaluation of flocculation phenomena. Poly-DADMAC was more efficient than PEI to induce the flocculation of FWAs. Alum was effective chemical for the flocculation and sedimentation of FWAs.

벼의 관수기간 및 수질이 광합성과 생육에 미치는 영향 (Effect of Overhead Flooding Stress on Photosynthesis and Growth in Rice)

  • 이상각;강병화
    • 한국작물학회지
    • /
    • 제46권3호
    • /
    • pp.209-214
    • /
    • 2001
  • 본 실험은 청수, 반탁수, 탁수에 따른 탁도처리와 관수시간에 따른 광합성, 엽록소형광, 증산량 및 회복능을 분석하여 관수스트레스에 대한 벼의 생리반응을 구명하고자 실시한 결과는 다음과 같다. 1. 광합성은 탁도가 높고, 관수 시간이 경과할수록 감소하였다. 특히 관수 36시간 전까지는 약 25%, 42시간이후에는 약 50%가 감소하였다. 증산량은 탁도 및 관수시간이 증가함에 따라 증가하였으며, 청수에서는 약 30%, 반탁수에서는 약 25%, 탁수에서는 약 20%가 증가하였다. Fv/Fm은 탁도 및 관수시간 증가에 따라 감소하였으며, 청수에서는 48시간이후에, 반탁수 및 탁수에서는 36시간이후 약 20%가 감소하였다. 전질소함량은 관수스트레스에 의해 감소하였고, 탁수처리 36시간이후부터 감소량이 켰다. 2. 관수스트레스에 따른 회복력을 나타내는 건물중은 탁도 리별 차이는 작았으나, 관수시간이 경과할수록 크게 감소하였다. 피해정도는 24시간안에는 약 25%, 42시간이후에는 각 처리구 모두에서 약 50%의 생장감소가 일어났다. 관수 48시간의 반탁수 및 탁수는 고사하였다. 광합성은 탁도에 따라서는 청수에서 약 15%, 반탁수, 탁수에서는 10%가 감소하였고, 특히 42시간이후에는 30-50% 감소하였다. 증산량은 탁도 및 관수시간에 처리간의 차이 없이 약 20%증가하였다. 3. 관수 24시간처리에서 관수처리 시 및 퇴수 후 회복기간에도 광합성과 증산량의 일시적인 감소가 일어났다

  • PDF

경주마(競走馬) 혈청(血淸)의 단백질(蛋白質), Bilirubin, Sodium 및 Potassium 농도(濃度)와 Thymol Turbidity (Concentrations of Total Protein, Bilirubin, Sodium and Potassium in Blood Sera and Thymol Turbidity of Race Horses)

  • 신광순;나동진;문희주;조종후
    • 대한수의학회지
    • /
    • 제14권1호
    • /
    • pp.23-27
    • /
    • 1974
  • Concentration of total protein, bilirubin, sodium and potassium in blood sera, and thymol turbidity of race horses, 78 males and 57 females aging from 2 to 5 years, were estimated. The results obtained were as follows: 1. Serum of race horses was low in protein concentrations as mean values of $5.48{\pm}0.77$ g/100ml. 2. Serum bilirubin was in normal range as mean values of total bilirubin, direct bilirubin and indirect bilirubin were $1.05{\pm}0.57$, $0.12{\pm}0.05$ and $0.93{\pm}0.58$ mg/100ml, respectively. 3. Mean value of serum thymol turbidity was $1.41{\pm}0.72$ S-H unit. 4. Mean values of serum sodium and potassium of race horses from Australia were $143{\pm}8.7$ and $3.85{\pm}0.53$ mEq/liter, respectively, and mean values of serum sodium and patassium of race horses from Japan were $142{\pm}9.4$ and $3.58{\pm}0.60$ mEq/liter, respectively.

  • PDF

Development of a Decision Support System for Turbid Water Management through Joint Dam Operation

  • Kim, Jeong-Kon;Ko, Ick-Hwan;Yoo, Yang-Soo
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.31-39
    • /
    • 2007
  • In this study we developed a turbidity management system to support the operation for effective turbid water management. The decision-making system includes various models for prediction of turbid water inflow, effective reservoir operation using the selective withdrawal facility, analysis of turbid water discharge in the downstream. The system is supported by the intensive monitoring devices installed in the upstream rivers, reservoirs, and downstream rivers. SWAT and HSPF models were constructed to predict turbid water flows in the Imha and Andong catchments. CE-QUAL-W2 models were constructed for turbid water behavior prediction, and various analyses were conducted to examine the effects of the selective withdrawal operation for efficient high turbid water discharge, turbid water distribution under differing amount and locations of turbid water discharge. A 1-dimensional dynamic water quality model was built using Ko-Riv1 for simulation of turbidity propagation in the downstream of the reservoirs, and 2-dimensional models were developed to investigate the mixing phenomena of two waters discharged from the Andong and Imha reservoirs with different temperature and turbidity conditions during joint dam operation for reducing the impacts of turbid water.

  • PDF

Characteristic of alumina-based microfiltration ceramic membrane

  • Hyunsoo, Kim;Oyunbileg, Purev;Eunji, Myung;Kanghee, Cho;Nagchoul, Choi
    • Membrane and Water Treatment
    • /
    • 제14권1호
    • /
    • pp.11-18
    • /
    • 2023
  • This work addresses the development of microfiltration ceramic membrane from alumina using extrusion method. The membranes were sintered at different temperatures ranging between 1000 and 1300℃. The alumina was characterized with thermogravimetric analysis, particle size distribution, X-ray diffraction, Fourier transform infrared spectrometer and scanning electron microscope analysis. Subsequently, the effect of sintering temperature on the membrane properties such as porosity, flexural strength, and pure water permeability was investigated and optimized for the sintering temperature. It is observed that with increasing sintering temperature, the porosity of the membranes decreases and the flexural strength, and pure water permeability of the membranes increase. The uncoated and coated membranes were compared at constant flux mode of filtration. Under the turbidity solution recirculation alone at 100 NTU, trans-membrane pressure (TMP) of uncoated membrane remained constant when the filtration flux was below 121 Lm-2 h -1 , while the coated membrane was 111 Lm-2 h -1 . Although suction pressure increased more rapidly at higher turbidity, coated membrane filtration showed better removal efficiency of the turbidity.

Turbidity Profile of Maleylated Glycinin

  • Kim, Kang-Sung;Kim, Myung-Hee;Kim Se-Ran;Kwon, Dae-Young
    • 한국환경보건학회지
    • /
    • 제30권4호
    • /
    • pp.314-319
    • /
    • 2004
  • Glycinin of more than $97\%$ purity was modified using maleic anhydride. Glycinin samples of $0\%,\;65\%,\;and\;95\%$ lysine residue modifications were used to determine the changes in turbidimetric characteristics of the protein due to maleylation. The solubility behavior of the protein as a function of pH was changed with maleylation. The isoelectric point of $65\%\;and\;95\%$ modified glycinin shifted to pH 4.0 and pH 3.5-4.0, respectively, as compared to pH 4.6 for native glycinin. Maleylated glycinins exhibited increased solubility at pH above 4.6. Turbidity of native glycinin decreased substantially by the addition of NaCl, but the stabilizing effect of NaCl decreased when the protein was chemically modified. The effect of NaCl on $65\%$ modified glycinin was intermediate between native glycinin and $95\%$ modified sample. Thermal aggregation of native glycinin was completed within 5 min of heating at $80^{\circ}C$. Maleylation contributed significantly to the thermostability of the protein at pH of 7.0 and 9.0, exhibiting little turbidity. Addition of NaCl suppressed thermal aggregation of native glycinin, but turbidity actually increased for the samples of $65\%\;and\;95\%$ modification.

소리쟁이(Rumex crispus) 뿌리로부터 가용성 고형분의 추출특성 (Extraction Characteristics of Soluble Solid from Rumex crispus(Curled Dock) Roots)

  • 정갑섭
    • 한국환경과학회지
    • /
    • 제20권10호
    • /
    • pp.1265-1272
    • /
    • 2011
  • In this study, the extraction characteristics of soluble solid from Rumex crispus(Curled dock) was studied from the investigation of the effects of experimental conditions on extraction rate; extraction ratio, composition of extractants, extraction time and pH of extractant, etc. The proximate composition of Rumex crispus was 2.58% crude lipid, 5.59% crude protein, 7.39% crude ash, 6.13% moisture and 78.31% carbohydrate, respectively. Turbidity of extract by distilled water was higher and increased with extraction time and extraction temperature, where as the turbidity didn't increase by ethanol and methanol in 20 folds of extraction ratio. Turbidity was inversely proportional to the extraction ratio for the three extractants at 25$^{\circ}C$ and 1 hour extraction. But turbidity of extract was highest by composition of 50% methanol-water extractant than any other compositions of extractants. Eighteen and fifteen free aminoacids were detected in extracts with distilled water, methanol and ethanol extractant, respectively, and it's contents were order of glutamic acid>proline>aminobutyric acid>alanine. The extraction rate of soluble solid from Rumex crispus was order of distilled water>methanol>ethanol within experimental extraction ratio. In extraction with distilled water, the contents of soluble solid was inversely proportional to the pH of extractant.

용수재이용을 위한 하수처리 유출수의 UV 소독 효율 연구 (Feasibility Study of UV-Disinfection for Water Reuse of Effluent from Wastewater Treatment Plant)

  • 윤춘경;정광욱;함종화;전지홍
    • 한국농공학회지
    • /
    • 제45권2호
    • /
    • pp.126-137
    • /
    • 2003
  • The feasibility study of UV-disinfection system was performed for disinfection of effluent from wastewater treatment plant. Three low-pressure UV lamps of 17, 25, and 41 W were examined with various flow rates. Low-pressure UV lamps of 17W were examined with various turbidity, DOM (dissolved organic matter), and SS (suspended solid). The pilot plant was a flow-through type UV-disinfection system, and the range of exposure time varied from 5 to 40 seconds, turbidity from 0 to 40 NTU, DOM from 0 to 30 mg/L, and SS from 10 to 40 mg/L. The 41W lamp demonstrated complete disinfection showing no survival ratio in all the experimental conditions, and generally 17W and 25W lamps also showed high removal ratio over 97%. For the same UV dose (UV intensity times exposure time), high intensity-short exposure conditions showed better disinfection efficiency than low intensity-long exposure conditions. While the effects of turbidity and DOM were not apparent, the effects of SS was significant on the disinfection efficiency which indicates that SS control before UV-disinfection appears to be necessary to increase removal efficiency. Considering characteristics of effluent from existing wastewater treatment plants, cost-effectiveness, stable performance, and minimum maintenance, the flow-through type UV-disinfection system with high intensity and low-pressure lamps was thought to be a competitive disinfection system for wastewater reclamation.

ELCOM-CAEDYM을 이용한 대청댐 유입탁수의 3차원 모델링 (3D Modeling of Turbid Density Flow Induced into Daecheong Reservoir with ELCOM-CAEDYM)

  • 정세웅;이흥수;류재일;류인구;오동근
    • 한국수자원학회논문집
    • /
    • 제41권12호
    • /
    • pp.1187-1198
    • /
    • 2008
  • 국내 많은 저수지들과 그 하류하천은 높은 탁도를 가진 물의 장기적인 방류로 인해 수자원 이용과 수생태계 관리에 많은 어려움을 겪고 있다. 탁도($C_T$)는 물의 탁한 정도를 나타내는 척도로써, 수질과 수환경의 건강을 평가하는 매우 중요한 지표로써 광범위하게 사용되어 왔지만, 모형의 검증에 필요한 실험 자료의 부족으로 인해 탁도 모델링에 대한 연구는 지금까지 매우 부족하였다. 본 연구의 목적은 광범위한 현장 실측자료를 이용하여 성층화된 대청호로 유입한 탁수의 밀도류 거동 모의를 위한 3차원 수리-입자동력학 연동 수치모형인 ELCOM-CAEDYM의 적용성을 검증하는데 있다. 입자크기에 따라 구분된 3개 그룹의 부유물질 (SS) 농도가 모형의 모의변수로 사용되었으며, 모형 변수인 SS와 저수지내 실측값의 $C_T$의 변환을 위해 저수지 지점별로 측정한 SS-$C_T$ 상관관계를 사용하였다. 모의결과는 2004년에 대청호의 회남과 댐앞 지점에서 수심별로 실측한 수온과 탁도 자료와 비교함으로써 검증하였다. 모형은 저수지의 성층구조, 탁수를 포함한 하천 밀도류의 시간에 따른 진행과정을 잘 재현하였으며, 탁도의 수직분포와 크기도 실측값과 부합하였다. 본 연구에서 제시한 3차원 수치모형과 탁도 모델링 방법론은 유사한 탁도 문제를 가지고 있는 다른 저수지에서도 탁수의 최적관리를 위한 지원 도구로써 사용 가능하다고 사료된다.

정수처리용 최적분리막 선정을 위한 수질 비교 (Comparison of Filtrate Quality to Select the Optimum Membrane for the Water Purification Process)

  • 박세호;최상일;김형수;황용우
    • 상하수도학회지
    • /
    • 제12권1호
    • /
    • pp.102-107
    • /
    • 1998
  • This study was conducted to investigate how the pore sizes of MF and UF membranes affected the removal efficiencies. The experimental results were compared with those obtained from the existing sand filter to select the optimum membrane. Turbidity of the raw water was adjusted to 10, 30, 50, 100, and 200NTU. The removal efficiencies of the turbidity and SS were nearly 100% for all membranes applied. Not membrane differences in the removal efficiencies of dissolved organics were also found. Thus, MF membrane with pore size $0.1{\mu}m$ was selected to obtain satisfactory removal efficiencies of turbidity and bacteria. Permeable flux was also considered. The $0.1{\mu}m$ MF membrane system was operated in the treatment plant to compare the results with those obtained from the existing sand filter. Turbidity, SS, $KMnO_4$ consumption, and number of coliform were chosen to be compared. Because there were not much differencies in the quality of the treated water, the existing coagulation-sedimentation-filtration process might be replaced and upgraded by simpler membrane process.

  • PDF