• 제목/요약/키워드: and resonance

Search Result 10,678, Processing Time 0.301 seconds

Comparison of MR Findings between Patients with Septic Arthritis and Acute Gouty Arthritis of the Knee (급성 통풍성 슬관절염과 패혈성 슬관절염의 자기공명영상 소견 비교)

  • Su Young Yun;Hye Jung Choo;Hae Woong Jeong;Sun Joo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1071-1080
    • /
    • 2022
  • Purpose To compare the MR findings of septic and acute gouty arthritis of the knee joint. Materials and Methods This retrospective study included patients who underwent knee MRI for septic or gouty arthritis at our hospital between October 2012 and October 2018. The MR findings were analyzed for the presence of bone marrow edema, soft tissue edema, abscess, pattern of synovial thickening (frondlike, lamellated, diffuse linear), maximum thickness of the synovium, and joint effusion volume. The gouty (n = 5) and septic arthritis (n = 10) groups were compared using the Wilcoxon rank-sum test and Fisher's exact test. Results No statistically significant differences were observed for each item. One patient in the gouty arthritis group and seven in the septic arthritis group had bone marrow edema. Soft tissue abscess formation was only observed in the septic group. The incidence of each synovial thickening pattern was as follows: 100% (diffuse linear) in the gouty arthritis group and 20% (frondlike), 50% (lamellated), and 30% (diffuse linear) in the septic arthritis group. Conclusion Differentiation of gouty arthritis and septic arthritis based on imaging findings is difficult. However, lamellated synovial thickening patterns, bone marrow edema, and soft tissue abscess formation are more commonly observed in patients with septic arthritis than in those with gouty arthritis.

Usefulness of Silent MRA for Evaluation of Aneurysm after Stent-Assisted Coil Embolization

  • You Na Kim;Jin Wook Choi;Yong Cheol Lim;Jihye Song;Ji Hyun Park;Woo Sang Jung
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.246-255
    • /
    • 2022
  • Objective: To determine the usefulness of Silent MR angiography (MRA) for evaluating intracranial aneurysms treated with stent-assisted coil embolization. Materials and Methods: Ninety-nine patients (101 aneurysms) treated with stent-assisted coil embolization (Neuroform atlas, 71 cases; Enterprise, 17; LVIS Jr, 9; and Solitaire AB, 4 cases) underwent time-of-flight (TOF) MRA and Silent MRA in the same session using a 3T MRI system within 24 hours of embolization. Two radiologists independently interpreted both MRA images retrospectively and rated the image quality using a 5-point Likert scale. The image quality and diagnostic accuracy of the two modalities in the detection of aneurysm occlusion were further compared based on the stent design and the site of aneurysm. Results: The average image quality scores of the Silent MRA and TOF MRA were 4.38 ± 0.83 and 2.78 ± 1.04, respectively (p < 0.001), with an almost perfect interobserver agreement. Silent MRA had a significantly higher image quality score than TOF MRA at the distal internal carotid artery (n = 57, 4.25 ± 0.91 vs. 3.05 ± 1.16, p < 0.001), middle cerebral artery (n = 21, 4.57 ± 0.75 vs. 2.19 ± 0.68, p < 0.001), anterior cerebral artery (n = 13, 4.54 ± 0.66 vs. 2.46 ± 0.66, p < 0.001), and posterior circulation artery (n = 10, 4.50 ± 0.71 vs. 2.90 ± 0.74, p = 0.013). Silent MRA had superior image quality score to TOF MRA in the stented arteries when using Neuroform atlas (4.66 ± 0.53 vs. 3.21 ± 0.84, p < 0.001), Enterprise (3.29 ± 1.59 vs. 1.59 ± 0.51, p = 0.003), LVIS Jr (4.33 ± 1.89 vs. 1.89 ± 0.78, p = 0.033), and Solitaire AB stents (4.00 ± 2.25 vs. 2.25 ± 0.96, p = 0.356). The interpretation of the status of aneurysm occlusion exhibited significantly higher sensitivity with Silent MRA than with TOF MRA when using the Neuroform Atlas stent (96.4% vs. 14.3%, respectively, p < 0.001) and LVIS Jr stent (100% vs. 20%, respectively, p = 0.046). Conclusion: Silent MRA can be useful to evaluate aneurysms treated with stent-assisted coil embolization, regardless of the aneurysm location and type of stent used.

Pattern Clustering of Symmetric Regional Cerebral Edema on Brain MRI in Patients with Hepatic Encephalopathy (간성뇌증 환자의 뇌 자기공명영상에서 대칭적인 지역 뇌부종 양상의 군집화)

  • Chun Geun Lim;Hui Joong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.381-393
    • /
    • 2024
  • Purpose Metabolic abnormalities in hepatic encephalopathy (HE) cause brain edema or demyelinating disease, resulting in symmetric regional cerebral edema (SRCE) on MRI. This study aimed to investigate the usefulness of the clustering analysis of SRCE in predicting the development of brain failure. Materials and Methods MR findings and clinical data of 98 consecutive patients with HE were retrospectively analyzed. The correlation between the 12 regions of SRCE was calculated using the phi (φ) coefficient, and the pattern was classified using hierarchical clustering using the φ2 distance measure and Ward's method. The classified patterns of SRCE were correlated with clinical parameters such as the model for end-stage liver disease (MELD) score and HE grade. Results Significant associations were found between 22 pairs of regions of interest, including the red nucleus and corpus callosum (φ = 0.81, p < 0.001), crus cerebri and red nucleus (φ = 0.72, p < 0.001), and red nucleus and dentate nucleus (φ = 0.66, p < 0.001). After hierarchical clustering, 24 cases were classified into Group I, 35 into Group II, and 39 into Group III. Group III had a higher MELD score (p = 0.04) and HE grade (p = 0.002) than Group I. Conclusion Our study demonstrates that the SRCE patterns can be useful in predicting hepatic preservation and the occurrence of cerebral failure in HE.

Imaging for Multiple Myeloma according to the Recent International Myeloma Working Group Guidelines: Analysis of Image Acquisition Techniques and Response Evaluation in Whole-Body MRI according to MY-RADS (International Myeloma Working Group의 최신 가이드 라인에 따른 다발성 골수종의 영상검사법 및 MY-RADS에 따른 전신 MRI에서의 영상 획득과 반응 평가 소개)

  • A Yeon Son;Hye Won Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.150-169
    • /
    • 2023
  • Multiple myeloma (MM) is a malignant hematologic disease caused by the proliferation of clonal plasma cells in the bone marrow, and its incidence is increasing in Korea. With the development of treatments for MM, the need for early diagnosis and treatment has emerged. In recent years, the International Myeloma Working Group (IMWG) has been constantly revising the laboratory and radiological diagnostic criteria for MM. In addition, as whole-body MRI (WBMR) has been increasing used in the diagnosis and treatment response evaluation of patients with MM, the Myeloma Response Assessment and Diagnosis System (MY-RADS) was created to standardize WBMR image acquisition techniques, image interpretation, and response evaluation methods. Radiologists need to have a detailed knowledge of the features of MM for accurate diagnosis. Thus, in this review article, we describe the imaging method for MM according to the latest IMWG guidelines as well as the image acquisition and response evaluation technique for WBMR according to MY-RADS.

Evalution for Joints of Coastal Environments Blocks (Coastal Environments 블록 적용을 위한 연결부 강도평가)

  • Kim, Chun-Ho;Kim, Kwang-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.6 s.58
    • /
    • pp.176-182
    • /
    • 2009
  • Other damage can occur due to the preexisting dull structure and installation of nonenvironmental-friendly concrete structure, lack of function for preventing coastal erosion. Increase of personal income and fast spread of the concept of waterfront casued the initiation of many project to improve aging coastal ports. However, none of environment-friendly structure has been developed and pre-existing solid block, igloo block, tunnel block are used commonly. In piers and lighter's wharf where the ships are mooring, resonance by the generation of a reflected wave caused by penetration wave in the port and port wave increases wave heights in the port and makes difficult to maintain the temperature, causes problems in mooring ships and cargo-working, and eventually increase the occurance of damages of the small ships by the collision. Therefore, development of new types of blcok is necessary. To apply Coastal Environments block developed for this reason, it requires allowable bearing capacity evaluation of shear key. For this study, we made test specimen for connecting part of C.E. Block, and conducted friction test of boundary surface. Data obtained by the experiment was analyzed by finite element analysis and assessed the coefficient of friction between C.E. Block and boundary surface.

A Study on Enacting the Radiologic Technologist Act for the Civil Right to Health in Korea (건강권과 방사선사법 제정에 관한 고찰)

  • Lim, Chang-Seon
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.313-320
    • /
    • 2007
  • There are the Medical Radiation Health and Safety Act(the Patient Radiation Health and Safety Act, the Radiologic Technologist Act), the Medical Laboratory Technologist Act, the Physical Therapy Practice Act, and the Dental Hygienist Act, etc in America. However, Korea has only one Act for a medical radiologic technologist(including radiation therapy technologist, nuclear medicine technologist), medical laboratory technologist, physical therapist, occupational therapy examiner, dental hygienist, and so on. It is the Medical Technologist Act. Therefore, the Medical Radiation Health and Safety Act for a radiologic technologist(including radiation therapy technologist, nuclear medicine technologist) has to be enacted independently in Korea. It is the purpose of this Act to provide for the appropriate certification of persons using radioactive materials, equipment emitting ionizing radiation on humans or performing medical imaging for diagnostic and therapeutic purposes. In Korea, the radiologic technologist is a "fusion technologist" who is a person other than a licensed practitioner as a radiographer, radiation therapist, nuclear medicine technologist, computed tomography technologist, magnetic resonance technologist, mammographer, sonographer, medical dosimetrist, quality management technologist, etc. This Act will have some provisions related to the definitions, reserved title, scope of practice, specialized technologist, application for licensure, radiologic technology council, renewal, continuing education, the radiation control advisory commission, etc. This Act will ensure that quality radiation therapy treatments are delivered and that quality diagnostic information is presented for interpretation, which will lead to accurate diagnosis, treatment and cure. Accurate diagnosis can be provided only when a personnel is properly educated in technique, equipment operation and radiation safety. In the end, this Act will protect the civil right to health. By regulating the personnel responsible for performing those procedures, this Act will mean improved care for patients-higher quality images, improved accuracy, and less exposure to radiation.

  • PDF

Design of a TM31 Higher Order Mode Half Circular-Ring Microstrip Patch Antenna for On-Body Communications (인체 표면 통신을 위한 TM31 고차 모드 반원-링 인체 부착형 마이크로스트립 패치 안테나 설계)

  • Tak, Jinpil;Jeon, Jaesung;Kim, Sunwoo;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.491-503
    • /
    • 2014
  • In this paper, a $TM_{31}$ higher order mode half circular-ring microstrip antenna with monopole-like radiation characteristic for on-body communication is proposed. By using shorting vias, $TM_{31}$ resonance mode was excited, while achieving compact low-profile antenna with monopole-like radiation characteristics. To overcome the narrow bandwidth of a patch antenna, a C-shape half ring patch with shorting vias having $TM_{31}$ mode is closely located around a half circular patch. For size reduction, half mode is adopted. The proposed antenna has the overall dimensions of $0.25{\lambda}_0{\times}0.46{\lambda}_0{\times}0.025{\lambda}_0$ at the industrial, scientific, and medical(ISM) 2.45 GHz band(2.4~2.485 GHz) and the 10-dB return loss is 4.24 % ranging from 2.38 to 2.49 GHz. To verify body effect, two-thirds muscle equivalent semi solid phantom was fabricated and used to measure the antenna performance. A communication link is analysed to investigate the effect of human-body movements and antenna locations.

Study on Mo(V) Species, Location and Adsorbates Interactions in MoH-SAPO-34 by Employing ESR and Electron Spin-Echo Modulation Spectroscopies (ESR, ESEM을 이용한 이온 교환된 MoH-SAPO-34에 대한 Mo의 화학종, 위치 및 흡착상호작용에 관한 연구)

  • Back, Gern-Ho;Jang, Chang-Ki;Ru, Chang-Kuk;Cho, Young-Hwan;So, Hyun-Soo;Kevan, Larry
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.1
    • /
    • pp.26-36
    • /
    • 2002
  • A solid-state reaction of $MoO_3$ with as-synthesized H-SAPO-34 generated paramagnetic Mo(V) species. The dehydration resulted in weak Mo(V) species, and subsequent activation resulted in the formation of Mo(V) species such as $Mo(V)_{5c}$ and $Mo(V)_{6c}$ that are characterized by ESR. The data of ESR and ESEM show the oxomolybdenum species, to be $(MoO_2)^+$ or $(MoO)^{3+}$. The $(MoO_2)^+$ species seems to be more probable. Since H-SAPO-34 has a low framework negative charge, $(MoO)^{3+}$ with a high positive charge can not be easily stabilized. A solution reaction between the solution of silico-molybdic acid and calcined H-SAPO-34 resulted in only $(MoO_2)^+$ species. A rhombic ESR signal is observed on adsorption of $D_2O$, $CD_3OH$, $CH_3Ch_2OD$ and $ND_3$. The Location and coordination structure of Mo(V) species has been determined by three-pulse electron spin-echo modulation data and their simulations. After the adsorption of methanol, ethylene, ammonia, and water for MoH-SAPO-34, three molecules, one molecule, one and one molecule, respectively, are directly coordinated to $(MoO_2)^+)$.

Requirements for Cerebrovascular Surgery in Comprehensive Stroke Centers in South Korea

  • Kim, Tackeun;Oh, Chang Wan;Park, Hyeon Seon;Lee, Kunsei;Lee, Won Kyung;Lee, Heeyoung
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.478-484
    • /
    • 2018
  • Objective : Cerebrovascular disease (CVD) was the third most common cause of death in South Korea in 2014. Evidence from abroad suggests that comprehensive stroke centers play an important role in improving the mortality rate of stroke. However, surgical treatment for CVD is currently slightly neglected by national policy, and there is still regional imbalance in this regard. For this reason, we conducted a survey on the necessity of, and the requirements for, establishing regional comprehensive cerebrovascular surgery centers (CCVSCs). Methods : This investigation was performed using the questionnaire survey method. The questionnaire was consisted with two sections. The first concerned the respondent's opinion regarding the current status of demand and the regional imbalance of cerebrovascular surgery in South Korea. The second section asked about the requirements for establishing regional CCVSCs. We sent the questionnaire to 100 board members of the Korean Society of Cerebrovascular Surgeons. Results : Most experts agreed that cerebrovascular surgery patients were concentrated in large hospitals in the capital area, and 83.6% of respondents agreed that it was necessary to alleviate the regional imbalance of cerebrovascular surgery. With regards to personnel, over 90% of respondents answered that at least two neuro-vascular surgeons and two neuro-interventionists are necessary to establish a CCVSC. Regarding facilities, almost all respondents stated that each CCVSC would require a neuro-intensive care unit and hybrid operating room. The survey asked the respondents about 13 specific neurovascular surgical procedures and whether they were necessary for a regional CCVSC. In the questions about the necessity of cerebrovascular surgical equipment, all seven pieces of equipment were considered essential by all respondents. A further five pieces of equipment were considered necessary on site: computed tomographic angiography, magnetic resonance angiography, conventional angiography, surgical microscope, and surgical navigation. Our results may provide a basis for future policy regarding treatment of cerebrovascular disease, including surgery. Conclusion : Raising the comprehensiveness of treatment at a regional level would lower the national disease burden. Policies should be drafted regarding comprehensive treatment including surgery for cerebrovascular disease, and related support plans should be implemented.

Multi-modality MEdical Image Registration based on Moment Information and Surface Distance (모멘트 정보와 표면거리 기반 다중 모달리티 의료영상 정합)

  • 최유주;김민정;박지영;윤현주;정명진;홍승봉;김명희
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.3_4
    • /
    • pp.224-238
    • /
    • 2004
  • Multi-modality image registration is a widely used image processing technique to obtain composite information from two different kinds of image sources. This study proposes an image registration method based on moment information and surface distance, which improves the previous surface-based registration method. The proposed method ensures stable registration results with low registration error without being subject to the initial position and direction of the object. In the preprocessing step, the surface points of the object are extracted, and then moment information is computed based on the surface points. Moment information is matched prior to fine registration based on the surface distance, in order to ensure stable registration results even when the initial positions and directions of the objects are very different. Moreover, surface comer sampling algorithm has been used in extracting representative surface points of the image to overcome the limits of the existed random sampling or systematic sampling methods. The proposed method has been applied to brain MRI(Magnetic Resonance Imaging) and PET(Positron Emission Tomography), and its accuracy and stability were verified through registration error ratio and visual inspection of the 2D/3D registration result images.