• Title/Summary/Keyword: and materials

Search Result 97,632, Processing Time 0.121 seconds

Effects of primers on the microtensile bond strength of resin cements to cobalt-chromium alloy (레진 시멘트와 코발트 크롬 합금의 미세인장결합강도에 다양한 프라이머들이 미치는 영향)

  • Jung, Hong-Taek;Campana, Shiela A.;Park, Jin-Hong;Shin, Joo-Hee;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.95-101
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate the effects of various primers on the microtensile bond strength (${\mu}TBS$) of resin cements to cobalt-chromium (Co-Cr) dental casting alloy. Materials and methods: Four adhesive primers (Universal primer, Metal primer II, Alloy primer, and Metal/Zirconia primer) and two resin cements (Panavia F2.0, G-CEM LinkAce) were tested. One hundred fifty Co-Cr beams were prepared from Co-Cr ingots via casting ($6mm\;ength{\times}1mm\;width{\times}1mm\;thick$). The metal beams were randomly divided into ten groups according to the adhesive primers and resin cements used; the no-primer groups served as the control (n = 15). After sandblasting with aluminum oxide ($125{\mu}m$ grain), the metal and resin cements were bonded together using a silicone mold. Prior to testing, all metal-resin beams were examined under stereomicroscope, and subjected to the ${\mu}TBS$ test. The mean value of each group was analyzed via one-way ANOVA with Tukey's test as post hoc (${\alpha}=.05$) using SPSS software. Results: The mean ${\mu}TBS$ of all groups was ranged from 20 to 28 MPa. There is no statistically significant difference between groups (P > .05). Mixed failure, which is the combination of adhesive and cohesive failures, is the most prevalent failure mode in both the Panavia F2.0 and G-Cem LinkAce groups. Conclusion: The ${\mu}TBS$ of all tested groups are relatively high; however, the primers used in this study result in no favorable effect in the ${\mu}TBS$ of Panavia F2.0 and G-Cem LinkAce resin cement to Co-Cr alloy.

Analysis of the Experiences and Perceptions of Teachers Participating in the Development of Content-Based Online Science Class Videos, and the Characteristics of the Developed Class Content (콘텐츠 활용형 온라인 과학 수업 동영상 개발에 참여한 교사들의 경험과 인식, 개발된 수업 콘텐츠의 특징 분석)

  • Shin, Jung Yun;Park, Sang Hee
    • Journal of The Korean Association For Science Education
    • /
    • v.40 no.6
    • /
    • pp.595-609
    • /
    • 2020
  • The purpose of this study is to analyze the experiences of teachers who participated in the development of online science class videos in the context of covid-19, their perception of online science class, and the characteristics of the online science class content developed by teachers. A survey and interviews were conducted with ten elementary school teachers who made online science class videos themselves. Also the characteristics of the online science class were investigated by analyzing the online science class video produced by the participants. As a result, participants in the study recognized the lack of production time, difficulty in filming and editing, concerns over misconceptions, the problem of solving copyrights for existing materials, and the burden of external disclosure. Although it was a teacher who had experience producing online science class video contents, no research participants actively answered the merits of online science class. On the other hand, the study participants cited that the shortcomings of online science classes were that students had fewer opportunities for inquiry and lack of communication or interaction. In particular, these shortcomings were thought to have a great influence on the quality of online science classes, especially in making inquiry classes difficult. Some teachers took a negative view that online science classes could not completely replace face-to-face classes. However, if multiple teachers are presented with supplementary teaching activities that complement the content-based online teaching method, the method of combining online science classes and face-to-face classes is not. Through the analysis of the contents of the online science class, the introduction and arrangement steps of the online science class were similar to the process of the face-to-face science class, but the inquiry step and the conceptual explanation step showed a big difference from the face-to-face science class.

Electrochemical Performance of CB/SiOx/C Anode Materials by SiOx Contents for Lithium Ion Battery (SiOx 함량에 따른 CB/SiOx/C 음극재의 전기화학적 특성)

  • Kim, Kyung Soo;Kang, Seok Chang;Lee, Jong Dae;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.117-123
    • /
    • 2021
  • In this study, the composite was prepared by mixing SiOx, soft carbon, and carbon black and the electrochemical properties of lithium ion battery were investigated. The content of SiOx added to improve the capacity of the soft carbon anode material was varied to 0, 6, 8, 10, 20 wt%, and carbon black was added as a structural stabilizer for reducing the volume expansion of SiOx. The physical properties of prepared CB/SiOx/C composite were investigated through XRD, SEM, EDS and powder resistance analysis. In addition, the electrochemical properties of prepared composite were observed through the charge/discharge capacity, rate and impedance analysis of the lithium ion battery. The prepared CB/SiOx/C composite had an inner cavity capable of mitigating the volume expansion of SiOx by adding carbon black. The formed internal cavity showed a low initial efficiency when the SiOx content was less than 8 wt%, and low cycle stability when the content of SiOx was less than 20 wt%. The CB/SiOx/C composite containing 10 wt% of SiOx showed an initial discharge capacity of 537 mAh/g, a capacity retention rate of 88%, and a rate of 79 at 2C/0.1C. SiOx was added to improve the capacity of the soft carbon anode material, and carbon black was added as a structural stabilizer to buffer the volume change of SiOx. In order to use the CB/SiOx/C composite as a high-efficiency anode material, the mechanism of the optimal SiOx and the use of carbon black as a structural stabilizer was discussed.

Antimicrobial Synergistic Effects of Gallnut Extract and Natural Product Mixture against Human Skin Pathogens (피부 병원성균에 대한 오배자 천연 복합물의 시너지 항균 효과)

  • Kim, Ju Hee;Choi, Yun Sun;Kim, Wang Bae;Park, Jin Oh;Im, Dong Joong
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.2
    • /
    • pp.155-161
    • /
    • 2021
  • This study was attempted to investigate natural materials with antimicrobial activity and to apply as natural preservatives in cosmetics. The disc diffusion method was used to search for nine species of natural antibacterial material for three species of skin pathogenic bacteria (Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa) and Candida albicans. As a result of measuring the size of inhibition zone, Rhus Semialata gall (Gallnut) extract, Oak vinegar, and ε-polylysine were showed strongest antibacterial activities (> 10 mm). The Minimum Bactericidal Concentration (MBC) of gallnut and oak vinegar ranged from 10 to 20 mg/mL and from 20 to 40 mg/mL against five human skin pathogens. The MBC of ε-polylysine ranged from 0.5 to 2 mg/mL in fungus. The synergic effect of gallnut extract/oak vinegar mixture and gallnut extract/ε-polylysine mixture were evaluated by checkerboard test. Compared to when used alone, the MBC of gallnut extract/oak vinegar mixture were at 4 times lower concentration against E. coli, C. albicans, and A. brasiliensis. Also Furthermore, the MBC of gallnut extract/ε-polylysine mixture were at 4 times lower concentration against C. albicans and A. brasiliensis. It was confirmed that the combination of gallnut extract with oak vinegar or ε-polylysine resulted in synergistic antibacterial effect against three human skin pathogens. Thus, it is expected that gallnut extract and natural product mixture can not only demonstrate antibacterial synergies, but also be applied in cosmetics as a natural preservative system with a wide antibacterial spectrum.

Report on the improvement of the in vitro and specimen reception environment system (핵의학과 검체 접수 환경시스템의 개선사례 보고)

  • Kim, Jung In;Kang, Mi Ji;Kim, Na Kyung;Park, Ji Sol;Kwon, Won Hyun;Lee, Kyung Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.29-34
    • /
    • 2021
  • Purpose Sample reception environment system in nuclear medicine has not changed much compared to 20 years ago. When preparing sample for in vitro test, there was no significant change because the test was carried out by generating an own specimen from the parent specimen. In this study, We would like to introduce a method that automatically removes the sample cap using the automated decapper equipment and enables automatic reception at the same time. In addition, including a provisional reception system. Materials and Methods In 2019, it was intended to get a device that automatically removes the cap of a patient's blood sample. This equipment is the same as the equipment used in the Department of Laboratory Medicine (Vacuette Ⓡ Unicap Belt Decapper, Greiner bio-one, Austria). However, the purchase was delayed due to differences in tube size, budget, and space. In January 2020, we borrowed domestic automatic decapper equipment and modified it to suit our laboratory environment. After 9 months, we were able to introduce a system that automatically removes the lid of a patient's blood sample and at the same time automatically accepts the test. And, through the provisional reception system, it was possible to know the arrival of the specimen in a short time. Results With the use of an automatic decapper device, the sample cap was automatically removed, and the reception proceeded at the same time. So, it was very efficient at work because it shortened the sample preparation time by about 20 minutes. In addition, it was possible to prevent the examiner's musculoskeletal disorders caused by repeated wrist use. After using the provisional reception system, patients were able to be discharged quickly, and the number of phone calls to confirm the arrival of samples was reduced. Conclusion Most hospitals have about four employees in the nuclear medicine in vitro laboratory. It is effective to use automatic decapper equipment and a provisional reception system for organizations that perform work with the minimum number of personnel.

A Study on Establishment of Reference Value of CA 72-4 (CA 72-4 참고치 설정에 관한 연구)

  • An, Jae-Seok;Kim, Ji-Na;Joe, Ye-Ji;Yoon, Sang-Hyuk;Kim, Yoon-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.25-28
    • /
    • 2021
  • Purpose CA 72-4 is a tumor marker that uses two monoclonal antibodies, CC49 and B72.3, to measure tumor-related glycoprotein(TAG72) in the serum. CA 72-4 is used to diagnose stomach, ovarian, and pancreatic cancers, and is known to perform high specificity for stomach cancer. The purpose of this study is to re-evaluate the reference value provided by the manufacturer through revalidation of the reference value in CA 72-4. Furthermore this study was conducted to provide useful help when making a clinical diagnosis at gastric cancer center. Materials and Methods We selected 271 patients who had been to health care center in national cancer center for the month of November 2020. The gender of the subjects was 140 males and 131 females, and the age group was from 30s to 60s. The reagent used in the study was a CA 72-4 IRMA KIT (ISOTOPES, Hungary) and the results were measured using a Dream Gamma-10 gamma counter (Shinjin medics, Korea). Results Statistical analysis of the results of this study used Hoffmann's method and Bayesian's method, which are primarily used in setting reference value. As a result of measuring CA 72-4 of 271 patients, the mean value was 4.54 U/mL and the median value was 3.30 U/mL. 24 people who deviated from 3SD were excluded from the measured value, the mean calculated after that was 3.53 U/mL, median was 3.00 U/mL and SD was 1.89. The reference value calculated based on this results was set to 7.31 U/mL. Conclusion The reference value provided by the manufacturer is less than 4 U/mL. It is slightly different from the value calculated in this study, 7.31 U/mL, so it seems necessary to reset the reference value according to the laboratory environment. Currently, we are receiving inquiries about the reference value from the center for gastric cancer at National Cancer Center. If additional research is carried out along with this study, it will be possible to set more accurate reference value.

Evaluation of the usefulness of IGRT(Image Guided Radiation Therapy) for markerless patients using SGPS(Surface-Guided Patient Setup) (표면유도환자셋업(Surface-Guided Patient Setup, SGPS)을 활용한 Markerless환자의 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)시 유용성 평가)

  • Lee, Kyeong-jae;Lee, Eung-man;Lee, Jeong-su;Kim, Da-yeon;Ko, Hyeon-jun;Choi, Shin-cheol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.109-116
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the usefulness of Surface-Guided Patient Setup by comparing the patient positioning accuracy when image-guided radiation therapy was used for Markerless patients(unmarked on the skin) using Surface-Guided Patient Setup and Marker patients(marked on the skin) using Laser-Based Patient Setup. Materials And Methods: The position error during IGRT was compared between a Markerless patient initially set up with SGPS using an optical surface scanning system using three cameras and a Marker patient initially set up with LBPS that aligns the laser with the marker drawn on the patient's skin. Both SGPS and LBPS were performed on 20 prostate cancer patients and 10 Stereotactic Radiation Surgery patients, respectively, and SGPS was performed on an additional 60 breast cancer patients. All were performed IGRT using CBCT or OBI. Position error of 6 degrees of freedom was obtained using Auto-Matching System, and comparison and analysis were performed using Offline-Review in the treatment planning system. Result: The difference between the root mean square (RMS) of SGPS and LBPS in prostate cancer patients was Vrt -0.02cm, Log -0.02cm, Lat 0.01cm, Pit -0.01°, Rol -0.01°, Rtn -0.01°, SRS patients was Vrt 0.02cm, Log -0.05cm, Lat 0.00cm, Pit -0.30°, Rol -0.15°, Rtn -0.33°. there was no significant difference between the two regions. According to the IGRT standard of breast cancer patients, RMS was Vrt 0.26, Log 0.21, Lat 0.15, Pit 0.81, Rol 0.49, Rtn 0.59. Conclusion:. As a result of this study, the position error value of SGPS compared to LBPS did not show a significant difference between prostate cancer patients and SRS patients. In the case of additionally performed SGPS breast cancer patients, the position error value was not large based on IGRT. Therefore, it is considered that it will be useful to replace LBPS with SGPS, which has the great advantage of not requiring patient skin marking..

Long-Term Survival Outcomes of Elderly Patients Treated With S-1 or Capecitabine Plus Oxaliplatin for Stage II or III Gastric Cancer: A Multicenter Cohort Study

  • Choi, Seohee;Min, Jae-Seok;Jeong, Sang-Ho;Yoo, Moon-Won;Son, Young-Gil;Oh, Sung Jin;Kim, Jong-Han;Park, Joong-Min;Hur, Hoon;Jee, Ye Seob;Hwang, Sun-Hwi;Jin, Sung-Ho;Lee, Sang Eok;Lee, Young-Joon;Seo, Kyung Won;Park, Sungsoo;Lee, Chang Min;Kim, Chang Hyun;Jeong, In Ho;Lee, Han Hong;Choi, Sung Il;Lee, Sang-Il;Kim, Chan-Young;Chae, Hyundong;Son, Myoung-Won;Pak, Kyung Ho;Kim, Sungsoo;Lee, Moon-Soo;Kim, Hyoung-Il
    • Journal of Gastric Cancer
    • /
    • v.22 no.1
    • /
    • pp.67-77
    • /
    • 2022
  • Purpose: Tegafur/gimeracil/oteracil (S-1) and capecitabine plus oxaliplatin (CAPOX) are standard adjuvant chemotherapies (ACs) administered after gastrectomy to patients with stage II or III gastric cancer. However, the efficacy of AC in elderly patients remains unclear. The objective of this retrospective multicenter cohort study was to compare the efficacies of S-1 and CAPOX AC in patients aged ≥70 years. Materials and Methods: Nine hundred eighty-three patients who were treated with AC using S-1 (768 patients) or CAPOX (215 patients) were enrolled in this study. Each patient underwent AC after curative gastrectomy for stage II or III gastric cancer at one of 27 hospitals in the Republic of Korea between January 2012 and December 2013. Relapse-free survival (RFS) and overall survival (OS) were analyzed according to AC regimen and age group. Results: Of the 983 patients, 254 (25.8%) were elderly. This group had a similar RFS (P=0.099) but significantly poorer OS (p=0.003) compared with the non-elderly group. Subgroup analysis of the non-elderly group revealed no AC-associated differences in survival. Subgroup analysis of the elderly group revealed significantly better survival in the S-1 group than in the CAPOX group (RFS, P<0.001; OS, P<0.001). Multivariate analysis revealed that the CAPOX regimen was an independent poor prognostic factor for RFS (hazard ratio [HR], 1.891; 95% confidence interval [CI], 1.072-3.333; P=0.028) and OS (HR, 2.970; 95% CI, 1.550-5.692; P=0.001). Conclusions: This multicenter observational cohort study found significant differences in RFS and OS between S-1 and CAPOX AC among patients with gastric cancer aged ≥70 years.

Selection of Excellent Genetic Resources Based on Comparison of Caffeic and Rosmarinic Acid Contents and Antioxidant Activity in Perilla Accessions (들깻잎의 caffeic acid와 rosmarinic acid 함량과 항산화 활성 비교를 통한 우수 유전자원 선발)

  • Kim, Yeong-Jee;Lee, Jae-Eun;Yoo, Eunae;Lee, Sookyeong;Wang, Xiaohan;Assefa, Awraris Derbie;Noh, Hyungjun
    • Korean Journal of Plant Resources
    • /
    • v.35 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Perilla is an annual plant in the family Lamiaceae and are widely cultivated in Asian countries. Perilla leaves are important sources of bioactive compounds and are reported to exhibit anti-inflammatory, antibacterial, anti-cancer and antioxidant effects, drawing attention as functional food materials. We examined caffeic acid, rosmarinic acid, total phenol content, and antioxidant activity in the leaves of 18 perilla accessions obtained from the gene bank of the National Agrobiodiversity Center, Jeonju, Korea. The caffeic acid content ranged between 9.86-27.52 mg/g with an average content of 17.75 mg/g while the level of. rosmarinic acid was in the range between 49.14 and 90.30 mg/g with an average content of 61.88 mg/g. The total polyphenol content ranged between 138.39 ㎍ GAE/mg dried extract (DE) and 378.19 ㎍ GAE/mg DE with an average content of 225.93 ㎍ GAE/mg DE. Cluster analysis based on the content of caffeic acid, rosmarinic acid. and antioxidant activity showed that the accessions collections were grouped in two distinct classes. The first group contained six genetic resources with high content of rosmarinic acid, and antioxidant activities respectively. The second group contained 12 genetic resources with high content of caffeic acid. These results could help develop new varieties of nutrient dense perilla resources.

Dual Plate Fixation for Periprosthetic Femur Fracture after Total Knee Arthroplasty (슬관절 전치환술 후 발생한 대퇴골 삽입물 주위 골절의 이중 금속판 고정술)

  • Kim, Dong Hwi;Cha, Dong Hyuk;Ko, Kang Yeol
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.26-33
    • /
    • 2021
  • Purpose: This study evaluated the results of dual plate fixation for periprosthetic femur fracture after total knee arthroplasty (TKA). Materials and Methods: From October 2007 to February 2013, 23 cases of periprosthetic femur fracture after TKA were treated at the author's hospital. There were 13 cases of fixation using a medial and lateral dual plate when the stability of the fracture site could not be achieved by one side fixation with a follow-up of more than one year. The cases included no loosening of the femoral component in fractures that were categorized as Lewis-Rorabeck classification II and supracondylar comminuted fractures and elongation of the fracture line to the lateral epicondyle of the femur or stem in the medullary canal. The mean age was 72 years (65-82 years), and 11 cases were female. Three cases had a stem due to revision. The mean bone marrow density was -3.2 (-1.7 to -4.4), and the mean period from primary TKA to periprosthetic fractures was 28 months (1-108 months). The mean follow-up period was 23 months (12-65 months). The medial fracture site was first exposed via the subvastus approach. Second, the supplementary plate was fixed on the lateral side of the fracture using a minimally invasive plate osteosynthesis technique. The average union time, complications, and Hospital for Special Surgery Knee Score (HSS) at the last follow-up were evaluated. Results: The mean union time was 17.4 weeks (7-40 weeks). Two cases showed delayed bone union and nonunion occurred in one case, in whom bone union was achieved three months later after re-fixation using a dual plate with an autogenous bone graft. The mean varusvalgus angulation was 1.67 degrees (-1.2-4.9 degrees), and the mean anterior-posterior angulation was 2.86 degrees (0-4.9 degrees) at the last follow-up. The mean knee range of motion was 90 degrees, and the HSS score was 85 points (70-95 points) at the last follow-up. Conclusion: Dual plate fixation for periprosthetic femur fractures that had not achieved stability by one side plate fixation after TKA showed a good clinical result that allowed early rehabilitation.