• Title/Summary/Keyword: and chemical pre-treatment

Search Result 362, Processing Time 0.023 seconds

Performance of Seedling Grafts of Tomato as Influenced by Root Medium Formulations and Leaching Fractions in Irrigation or Fertigation (혼합상토 조성과 관수 또는 관비시 배액률이 토마토 접목묘 생장에 미치는 영향)

  • Choi, Jong Myung
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.235-243
    • /
    • 2014
  • This research was conducted to investigate the influence of leaching fractions (LF) in each irrigation or fertigation on plant growth and changes in chemical properties of root media during the production of seedling grafts of tomato. Two root media containing Sphagnum peat moss plus vermiculite (5:5, v/v, PV) and coir dust plus vermiculite (5:5, v/v, CV) were formulated and pre-planting fertilizers were incorporated during formulation. Then, each medium was packed into 50 cell (volume 33 cc) and 105 cell (volume 18 cc) trays and the rootstock (cv. J3B Strong) and scion (cv. Sunmyung) were grown, respectively. The seedlings were grafted at 31 days after sowing and then the cut seedling grafts (Sunmyung scion/J3B Strong rootstock) were planted into 50 cell plug trays containing each of the two root media. After induction of the graft union and new adventitious roots for 7 days, the seedling grafts were fed with fertilizer solution once a week containing 4 different N concentrations (0, 50, 100, $200mg{\cdot}L^{-1}$). When determined after 31 days from seed sowing, the highest fresh weights of the root stock seedlings were obtained with 0.75 LF in PV (8.96g/seedling) and CV (7.11g/seedling) mixes. The EC of the both mixes were 0.93 and $1.09dS{\cdot}m^{-1}$, respectively. The fresh weights of the scion seedlings 31 days after seed sowing were 4.29g with 0.50 LF in the PV and 3.13g with 0.50 LF in the CV. The root medium ECs of the two treatments were 0.76 and $1.34dS{\cdot}m^{-1}$, respectively. Fresh weights of the seedling grafts grown for 31 days were greatly influenced by post-planting fertilizer concentrations. The heavier plants were obtained in $100mg{\cdot}L^{-1}$ N treatment than any other treatments in same mixes. The substrate ECs in these two treatments were 0.98 and $1.93dS{\cdot}m^{-1}$, respectively, indicating that the desirable range of soluble salts in soil extracts is higher in the CV mix than the PV mix. Results of this study suggest that optimum EC range is different in each medium and LF need to be adjusted differently for each root medium to produce high quality seedling grafts of tomato.

Evaluation of HbA1c Levels Via the Latex Immunoturbidimetric Method by Using Chemistry Autoanalyzer (자동화학분석기에서의 라텍스 면역비탁법의 Autolab HbA1c 평가)

  • Jo, Yongjun;Lee, So-young;Park, Hae-il;Kim, YeongSic;Lee, Jehoon;Kim, Yonggoo;Han, Kyungja
    • Laboratory Medicine Online
    • /
    • v.2 no.1
    • /
    • pp.10-14
    • /
    • 2012
  • Background: Measurement of HbA1c levels is widely used to diagnose diabetes mellitus and to evaluate and monitor plasma-glucose concentrations over 6-8 weeks. In this study, we evaluated the diagnostic performance of the newly developed latex immunoturbidimetric method by using Autolab HbA1c. Methods: We analyzed and compared the diagnostic performance of Autolab HbA1c with that of Toshiba 200FR between April 2009 and July 2009. According to guidelines (EP5-A2, EP6-P, EP9-A2) of the clinical and laboratory standards institute (CLSI), we compared linearity, precision and correlation of Autolab HbA1c with those of G7 (Tosoh Corp., Kyoto, Japan) by using high-performance liquid chromatography (HPLC) method. Results: Data obtained using Autolab HbA1c showed good linearity in mixtures of samples with low (3.1%) and high (15.1%) levels of HbA1c (r2=0.9997). In the analysis of within-run precision of the samples with HbA1c levels of 5.1% and 12.1%, the SDs were 0.04 and 0.06 and covariances of these samples were 0.8% and 0.5%, respectively. In the Deming regression model, the regression equation was as follows: Autolab HbA1c=1.0859×Tosoh HPLC-0.6957. Conclusions: In this study, Autolab HbA1c method showed better performance characteristics than Tosoh G7 did. In reference review, there was no interference of variant hemoglobin. The data acquisition time of Autolab HbA1c was lower than that of Tosoh G7. The advantages of Autolab HbA1c are that it can be used as an autoanlyzer in routine chemical analysis, it does not require pre-analytical treatment, and the samples are automatically treated with distilled water for hemolysis.