• 제목/요약/키워드: and Transformer

검색결과 3,973건 처리시간 0.025초

변압기 효율 적정화를 위한 변압기 부하율 조사 및 추정 (Investigation and Estimation of Transformer Load Factor for Rationalization of Transformer's Efficiency)

  • 김종민;김영석;길형준;송길목
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.96-101
    • /
    • 2016
  • In this paper, We investigate the number of 795 transformer in the private electrical facilities and analyze the annual load factor. The results show that the annual load factor of transformer is 20.16% in manufacturing industry, education services(school) is 9.59%, retail and wholesale services is 19.68%, resort and leisure industry is 10.93%, office building is 13.10%, and apartment houses is 14.69%. Education services, resort and leisure industry are being operated with a very low annual load factor. The relatively small capacity of less than 500kVA transformer also been analyzed that is being operated with a low load factor. Therefore, In order to minimize the power loss of the transformer, it is advisable to complement the Transformer Efficiency Management system to be designed the efficiency is good transformer when the load is low. Analysis results will be used as the basis for the provision of transformer efficiency management system and be used High-efficiency transformers promotion system.

소형 변압기 안전성 실태 분석 및 고찰 (The Safety Survey Analysis and Consideration of Small Transformer)

  • 김성삼
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, safety certification products and safety condition of small transformer is analyzed in industries field and educational facilities. In transformer of 50places, absolute majority is step down transformer to measure of instrument. Most transformers were below 5kVA and 1~3kVA capacity was the mainstream. In industries field, 5 transformers were found without safety certification according to the Electrical Appliances Safety Control Act as cheap product prefer and lack of safety consciousness. Mark & number, voltage, date of manufacture of safety certification must show item of certification. However date of manufacture showed in product of 18%, 9places. As result of thermal imaging camera, running temperature of transformer was showed in below of target temperature. However as a narrow space of transformer and wall, power cable was touched on a ventilating flue in transformer. It was simple carelessness case that surface fouling and temperature ageing of transformer accelerate. Power poor connection, neglect of transformer in production equipment, fall damage by setup incongruity and ground omission were found in case of illogicality item of transformer.

몰드변압기의 공기덕트의 구조 변화에 따른 온도특성 해석 (Analysis of Temperature Characteristic According to Variation of Air Duct of the Cast Resin Transformer)

  • 김지호;이향범;손진근
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.256-260
    • /
    • 2015
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 24 MVA distribution cast resin transformer using CFD(Computational Fluid Dynamics). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage(HV) winding and low-voltage(LV) winding of cast resin transformer and Joule's loss of core for improvement these life, forecasted heat source, and HV winding and LV winding of cast transformer rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the results. Also, calculated temperature rise limit of cast resin transformer and permission maximum temperature using analysis by electromagnetic heat source. Calculated and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

몰드변압기 소음저감을 위한 진동특성 파악 (The vibration characteristics for noise reduction of mold transformer)

  • 김기원;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.49-53
    • /
    • 2008
  • This study deals a way to reduce the transformer noises. The first step is to identify the source of the transformer noises. The second step is obtaining the vibration characteristics of transformer; its natural frequencies and mode shapes. Based on these information, an method to reduce the vibration of transformer can be found. The cause of transformer noises is mainly due to the magnetostrictive vibration of a core which is made of ferromagnetic substances. It is well known that the magnetostrictive vibration of a core is unavoidable, and a way to reduce the transformer noise by structural design is needed. It requires understanding the vibration characteristics. The natural frequencies and the mode shapes of transformer are analyzed by performing the modal testing.

  • PDF

단상 NPC Module- 3직렬 Cascade 구성 방식의 75KVA급 단상 지능형 변압기 개발 (Single Phase NPC Module - Development of 75KVA Single Phase Smart Transformer with 3 Serial Cascade Configuration)

  • 박주영;니이테게카;조경식;김명룡;박가우
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.118-125
    • /
    • 2017
  • In this paper, we propose a smart transformer for a smart transformer miniature model, which can replace a 60 [Hz] single-phase transformer installed in an electric vehicle. The proposed smart transformer is lighter than a conventional transformer, can control instantaneous voltage, and can be expected to improve power quality through harmonic compensation. The proposed intelligent transformer consists of an incoming part, an AC/DC converter, and a dual active bridge. Only the incoming part and the AC/DC converter are described in this paper. The proposed intelligent transformer has 75 kVA 3.3 kV input and 750 V DC output, which are verified by simulation and experiment.

High-Speed Transformer for Panoptic Segmentation

  • Baek, Jong-Hyeon;Kim, Dae-Hyun;Lee, Hee-Kyung;Choo, Hyon-Gon;Koh, Yeong Jun
    • 방송공학회논문지
    • /
    • 제27권7호
    • /
    • pp.1011-1020
    • /
    • 2022
  • Recent high-performance panoptic segmentation models are based on transformer architectures. However, transformer-based panoptic segmentation methods are basically slower than convolution-based methods, since the attention mechanism in the transformer requires quadratic complexity w.r.t. image resolution. Also, sine and cosine computation for positional embedding in the transformer also yields a bottleneck for computation time. To address these problems, we adopt three modules to speed up the inference runtime of the transformer-based panoptic segmentation. First, we perform channel-level reduction using depth-wise separable convolution for inputs of the transformer decoder. Second, we replace sine and cosine-based positional encoding with convolution operations, called conv-embedding. We also apply a separable self-attention to the transformer encoder to lower quadratic complexity to linear one for numbers of image pixels. As result, the proposed model achieves 44% faster frame per second than baseline on ADE20K panoptic validation dataset, when we use all three modules.

변류기 2차측 개방 보호장치 개발 및 특성 (Development and Characteristics of Detector for Open of Current Transformer Secondary Terminal)

  • 최상원;송기찬
    • 한국안전학회지
    • /
    • 제22권4호
    • /
    • pp.20-25
    • /
    • 2007
  • Instrument transformers are a safe measurement device designed to measure high voltage and large current. A current transformer(CT) is a type of instrument transformer designed to provide a current in its secondary winding proportional to the current flowing in its primary. It is commonly used in metering and protective relaying in the electrical power industry where it facilitates the safe measurement of large current. But, care must be taken that the secondary of a current transformer is not disconnected from its load while current is flowing in the primary, as this will produce a dangerously high voltage across the open secondary, and may permanently affect the accuracy of the transformer. Especially, industrial disaster such as an electric shock and/or a burn accident occurs occasionally by disregard of warning or attention. In this paper, we developed the detector for open of current transformer secondary terminal, and which was tested by the Korea Electrotechnology Research Institute. Test results show that Current Transformer secondary Open Detector(CTOD) interrupted within one second electronically when the 2nd terminal of current transformer opened.

OLTC를 고려한 33 MVA 초전도 변압기 설계 (Design of a 33 MVA HTS Transformer with OLTC)

  • 최지훈;이승욱;박명진;김우석;최경달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.885-886
    • /
    • 2006
  • We have proposed a 100 MVA, 3 phases, 154 kV class HTS transformer which will substitute for 60 MVA conventional transformer. In this paper, we designed conceptually the structure of the superconducting windings of a single phase 33 MVA transformer. The power transformer of 154 kV class has a tertiary winding besides primary and secondary windings. So the HTS transformer should have the 3rd superconducting winding, it makes the cost of the HTS transformer high and the efficiency low. Further more we considered On Load Tap Changer (OLTC) in HTS power transformer. OLTC equipment is required for fitting to a power transformer by which the voltage ratio between the windings can be varied while the transformer is on load. We analyzed the electrical characteristics of the HTS transformer such as magnetic stress and AC loss.

  • PDF

3차 권선을 고려한 단상 33MVA 고온초전도 변압기의 개념설계 (Conceptual Design of a Single Phase 33 MVA HTS Transformer with a Tertiary Winding)

  • 이승욱;김우석;한송엽;황영인;최경달
    • Progress in Superconductivity
    • /
    • 제7권2호
    • /
    • pp.162-166
    • /
    • 2006
  • We have proposed a 3 phase, 100 MVA, 154 kV class HTS transformer substituting for a 60 MVA conventional transformer. The power transformer of 154 kV class has a tertiary winding besides primary and secondary windings. So the HTS transformer should have the 3rd superconducting winding. In this paper, we designed conceptually the structure of the superconducting windings of a single phase 33 MVA transformer. The electrical characteristics of the HTS transformer such as % impedance and AC loss vary with the arrangement of the windings and gaps between windings. We analyzed the effects of the winding parameters, evaluated the cost of each design, and proposed a suitable HTS transformer model for future power distribution system.

  • PDF

고속철도차량 주변압기 기계적 특성 분석 (A Study on Mechanical Characteristic Analysis for Main Transformer of High Speed Railway)

  • 한영재;김석원;이태형;구훈모;조광우;박상옥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.713-718
    • /
    • 2006
  • In this study, temperature sensors were adhered to transformer that is used in KHST(Korean High-Speed Train) to verify variation of temperature characteristics about transformer synthetically and efficiently. In the case that temperature of transformer exceeds reference temperature for running of KHST, overheating of transformer may cause a fatal accident of vehicle. Characteristics and main specifications of transformer in KHST were described in this paper. Also, measuring system for temperature measurement of transformer was explained in brief. Temperature data of transformer was acquired using measuring system, KRRI(Korea Railroad Research Institute) analyzed characteristic in contrast with comparing with temperature of transformer about month, running speed and running time.

  • PDF