• Title/Summary/Keyword: anatomic variation

Search Result 67, Processing Time 0.026 seconds

Positioning errors of dental implants and their associations with adjacent structures and anatomical variations: A CBCT-based study

  • Ribas, Beatriz Ribeiro;Nascimento, Eduarda Helena Leandro;Freitas, Deborah Queiroz;Pontual, Andrea dos Anjos;Pontual, Maria Luiza dos Anjos;Perez, Danyel Elias Cruz;Ramos-Perez, Flavia Maria Moraes
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.281-290
    • /
    • 2020
  • Purpose: The objective of the present study was to evaluate the prevalence of dental implants positioning errors and their associations with adjacent structures and anatomical variations by means of cone-beam computed tomography (CBCT). Materials and Methods: CBCT images of 207 patients (584 dental implants) were evaluated by 2 oral radiologists. The distance between the implant and the adjacent teeth/implants was measured and classified as adequate (≥1.5 mm and ≥3 mm, respectively) or inadequate. The presence of thread exposure, cortical perforation, implant dehiscence, implant penetration into adjacent structures, and anatomical variations was also recorded. The incisor canal diameter and the depth of the concavity of the submandibular fossa were measured in order to evaluate their correlations with the frequency of implant penetration in these structures. Descriptive analyses, the Fisher exact test, and Spearman correlation analysis were performed (α=0.05). Results: The overall prevalence of positioning errors was 82.9%. The most common error was the inadequate distance between the implant and the adjacent teeth/implants. The presence of anatomical variations did not significantly influence the overall prevalence of errors (P>0.05). There was a positive correlation between the diameter of the incisor canal and the frequency of implant penetration in this structure (r=0.232, P<0.05). Conclusion: There was a high prevalence of dental implant positioning errors, and positioning errors were not associated with the presence of anatomical variations. Professionals should be aware of the space available for implant placement during the preoperative planning stage.

Anomalous Origins of the Bilateral Vertebral Arteries Arising from the Aortic Arch: A Case Report (대동맥궁에서 기시하는 양측 추골동맥의 이상기시: 증례 보고)

  • Changhyun Park;Byung Hoon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.743-748
    • /
    • 2021
  • Various anomalous origins of the vertebral arteries (VAs) have been reported. However, anomalous origins of the bilateral VAs arising directly from the aortic arch are extremely rare. We encountered a 60-year-old male who developed sudden-onset right hemiparesis with an incidentally discovered rare origins of the bilateral VAs from aortic arch. CT angiography demonstratedt he right VA originating from the aortic arch distal to the left subclavian artery and left VA originating from the aortic arch between the left common carotid artery and the left subclavian artery. The possible embryological mechanism of this variant was also reviewed. If the VA can not be found in the usual position during the procedure, a rare variant of the VA with anomalous origin should be considered. Understanding these variations is important to avoid unexpected events during endovascular procedures or surgery.

Sural nerve involvement accompanying peroneal nerve palsy (비골신경 마비에 따른 비복신경 손상의 정도)

  • Yoon, Won-Tae;Lee, Taek-Jun;Shin, Kyung-Jin;Kim, Byoung-Joon
    • Annals of Clinical Neurophysiology
    • /
    • v.6 no.1
    • /
    • pp.31-34
    • /
    • 2004
  • Backgrounds: The pathway of the sural nerve (SN) is variable, but usually divided into medial and lateral sural branches joining the posterior tibial nerve (PTN) and the peroneal nerve (PN). The sural nerve may be affected by PN palsy. The frequency or the severity of SN involvement in peroneal palsy is not known. The purpose of the study is to investigate the frequency and the severity of the SN involvement by the peroneal nerve palsy. Methods: Total 85 patients were included with peroneal palsy. Amplitudes of distal peroneal, sural, and superficial peroneal nerves (SPN) were compared between normal and paralyzed sides. The frequency and severity of SN involvement by peroneal palsy were investigated. Results: Mean age was $48.4{\pm}17.4$ years old at the time of the test. Peroneal palsy was right side in 32, left in 38, and bilateral in 15 patients. Mean amplitudes of affected distal PN, SPN, and SN were $1.51{\pm}1.64mV$, $3.50{\pm}4.86{\mu}V$, and $10.42{\pm}6.59{\mu}V$ in right side, and $1.19{\pm}1.57mV$, $4.38{\pm}5.67{\mu}V$, and $11.06{\pm}6.87{\mu}V$ in left side, respectively. Sensory nerve action potential (SNAP) amplitude of the SN in the affected side was average $73.7{\pm}33.1%$ of normal, which was significantly lower than that in the normal side(p<0.01). The decrease of the sural SNAP amplitude was more than 15% in 39 out of 70 patients with unilateral peroneal palsy. Peroneal compound muscle action potential (CMAP) amplitude was not correlated with the amplitude of the sural SNAP. By complete peroneal palsy, SN SNAP amplitude was decreased to 4% of SNAP and $57.7{\pm}31.8%$ of that in normal side. Conclusions: PN injury without PTN involvement may induce reduction of sural SNAP amplitude. Because of the anatomic variation of SN, the electrophysiological findings are variable. It should be considered to interpret the location of the PN lesion.

  • PDF

A comparative study of established z score models for coronary artery diameters in 181 healthy Korean children

  • Ryu, Kyungguk;Yu, Jeong Jin;Jun, Hyun Ok;Shin, Eun Jung;Heo, Young Hee;Baek, Jae Suk;Kim, Young-Hwue;Ko, Jae-Kon
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.11
    • /
    • pp.373-378
    • /
    • 2017
  • Purpose: The aim of this study was to investigate the statistical properties of four previously developed pediatric coronary artery z score models in healthy Korean children. Methods: The study subjects were 181 healthy Korean children, whose age ranged from 1 month to 15 years. The diameter of each coronary artery was measured using 2-dimensional echocardiography and converted to the z score in the four models (McCrindle, Olivieri, Dallaire, and Japanese model). Descriptive statistical analyses and 1-sample t tests were performed. Results: All calculated z scores had P values of ${\geq}0.050$ using the Kolmogorov-Smirnov test. The one sample t test showed that the mean z scores did not converge to zero except in 1 model, and the mean right coronary artery (RCA) z score was less than zero in all 4 models. The smaller RCA diameter in this study could be associated with the more distal measuring point used to avoid the conal branch. The percentage of subjects with extreme z score values (${\geq}2.0$ and ${\geq}2.5$) for the left main coronary artery (LMCA) seems to be higher in the Dallaire (4.9% and 3.3%) and Japanese models (7.1% and 3.8%). Conclusion: All 4 models showed statistical feasibility of normal distribution. More precise instructions would be needed for the measurement of the RCA. The higher percentage of extreme z scores for the LMCA is compatible with the basic understanding of anatomic variation in the LMCA.

Correlation of Proliferating Cell Nuclear Antigen (PCNA) Expression and S-phase Fraction, Survival Rate in Primary Non-Small Cell Lung Cancer (원발성 비소세포 폐암에서 PCNA의 발현정도와 암세포의 분열능 및 생존률과의 관계)

  • Yang, Sei-Hoon;Kim, Hak-Ryul;Gu, Ki-Seon;Jung, Byung-Hak;Jeong, Eun-Taik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.756-765
    • /
    • 1997
  • Background : To study the prognosis of patients with lung cancer, many investigators have reported the methods to detect cell proliferation in tissues including PCNA, thymidine autoradiography, flow cytometry and Ki-67. PCNA, also known as cyclin, is a cell related nuclear protein with 36KD intranuclear polypeptide that is maximally elevated in S phase of proliferating cells. In this study, PCNA was identified by paraffin-embedding tissue using immunohistochemistry which has an advantage of simplicity and maintenance of tissue architecture. The variation of PCNA expression is known to be related with proliferating fraction, histologic type, anatomic(TNM) stage, degree of cell differentiation, S-phase fraction and survival rate. We analyzed the correlation between PCNA expression and S-phase fraction, survival. Method : To investigate expression of PCNA in primary lung cancer, we used immunohistochemical stain to paraffin-embedded sections of 57 resected primary non-small cell lung cancer specimen and the results were analyzed according to the cell type, cell differentiation, TNM stage, S-phase fraction and survival. Results : PCNA expression was divided into five group according to degree of staging(-, +, ++, +++, ++++). Squamous cell type showed high positivity than in adenocarcinoma. Nonsignificant difference related to TNM stage was noticed. Nonsignificant difference related to degree of cell differentiation was noticed. S-phase fraction was increased with advance of PCNA positivity, but it could not reach the statistic significance. The 2 year survival rate and median survival time were -50% 13 months, +75% 41.3 months, ++73% 33.6 months, +++67% 29.0 months, ++++25% 9 months with statistic significance (P<0.05, Kaplan-Meier, generalized Wilcox). Conclusion : From this study, PCNA expression was high positive in squamous cell cancer. And, there was no relationship between PCNA positivity and TNM stage, cellular differentiation or S-phase fraction. But, the patients with high positive PCNA staining showed poor survival rate than the patients with lower positive PCNA staining (p<0.05). It was concluded that PCNA immunostaining is a simple and useful method for survival prediction in paraffin embedded tissue of non-small cell lung cancer.

  • PDF

Impact of Pulmonary Vascular Compliance on the Duration of Pleural Effusion Duration after Extracardiac Fontan Procedure (수술 전 폐혈관 유순도가 심장 외 도판을 이용한 Fontan 수술 후 늑막 삼출 기간에 미치는 영향)

  • Yun Tae-Jin;Im Yu-Mi;Song Kwang-Jae;Jung Sung-Ho;Park Jeong-Jun;Seo Dong-Man;Lee Moo-Song
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.579-587
    • /
    • 2006
  • Background: Preoperative risk analysis for Fontan candidates is still less than optimal in that patients with apparently low risks may have poor surgical outcome; prolonged pleural drainage, protein losing enteropathy, pulmonary thromboembolism and death. We hypothesized that low pulmonary vascular compliance (PVC) is a risk factor for prolonged pleural effusion drainage after the Fontan operation. Material and Method: A retrospective review of 96 consecutive patients who underwent the Extracardiac Fontan procedures (median age: 3.9 years) was performed. Fontan risk score (FRS) was calculated from 12 categorized preoperative anatomic and physiologic variables. PVC $(mm^2/m^2{\cdot}mmHg)$ was defined as pulmonary artery index $(mm^2/m^2)$ divided by total pulmonary resistance $(W.U{\cdot}/m^2)$ and pulmonary blood flow $(L/min/m^2)$ based on the electrical circuit analogue of the pulmonary circulation. Chest tube indwelling time was log-transformed (log indwelling time, LIT) to fit normal distribution, and the relationship between preoperative predictors and LIT was analyzed by multiple linear regression. Result: Preoperative PVC, chest tube indwelling time and LIT ranged from 6 to 94.8 $mm^2/mmHg/m^2$ (median: 24.8), 3 to 268 days (median: 20 days), and 1.1 to 5.6 (mean: 2.9, standard deviation: 0.8), respectively. FRS, PVC, cardiopulmonary bypass time (CPB) and central venous pressure at postoperative 12 hours were correlated with LIT by univariable analyses. By multiple linear regression, PVC (p=0.0018) and CPB (p=0.0024) independently predicted LIT, explaining 21.7% of the variation. The regression equation was LIT=2.74-0.0158 PVC+0.00658 CPB. Conclusion: Low pulmonary vascular compliance is an important risk factor for prolonged pleural effusion drainage after the extracardiac Fontan procedure.

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF