• Title/Summary/Keyword: analytical testing

Search Result 442, Processing Time 0.02 seconds

Validation of the Proximity of Clothing to Self Scale for Older Persons (의복의 자아 근접성 척도 검증 - 노년층을 대상으로 -)

  • Lee, Young-A;Sontag, M. Suzanne
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.6 s.165
    • /
    • pp.848-858
    • /
    • 2007
  • Sontag and Lee (2004) recently developed an objectively measurable instrument, the Proximity of Clothing to Self(PCS) Scale, which measured the psychological closeness of clothing to self. They validated a 4-factor, 24-item PCS Scale for use with adolescents and identified the need for confirmation of the factor structure with other age groups. This paper extends the work of Sontag and Lee by employing the PCS Scale with older persons, age 65 and over, and reports the validation of a 3-factor, 19-item PCS Scale for older persons. A mail survey was sent to a national random sample of 1,700 older Persons by means of a list purchased from a U.S. survey sampling company in late November 2004. Total usuable number of respondents was 250 with an adjusted response rate of 15.6 percent. Three analytical rounds of confirmatory factor analysis(CFA) to test the construct validity of the PCS Scale were conducted by using AMOS 5.0(Analysis of Moment Structures), one of several structural equation modeling(SEM) programs. Completion of three rounds of the CFA resulted in a 3-factor, 19-item PCS Scale with demonstrated construct validity and reliability for older persons. The three PCS dimensions are clothing in relation to 1) self as structure-process(PCS Dimension 1-2-3 combined), 2) self-esteem-evaluative and affective processes(PCS Dimension 4-5 combined), and 3) body image and body cathexis(PCS Dimension 6). The initially hypothesized 6-factor scale(Sontag & Lee, 2004) was not confirmed for adolescents in their study nor with older persons in this study. In addition, the 4-factor solution for the adolescent group did not hold for older persons. It appears that the self-system of older persons is more integrated than may be true for younger individuals. Recommendations for future testing of construct validity of the PCS Scale are made.

Flexural Test of H-Shape Members Fabricated of High-Strength Steel with Considering Local Buckling (국부좌굴을 고려한 고강도 조립 H형강 부재의 휨성능 실험)

  • Lee, Cheol-Ho;Han, Kyu-Hong;Park, Chang-Hee;Kim, Jin-Ho;Lee, Seung-Eun;Ha, Tae-Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.417-428
    • /
    • 2011
  • Depending on the plastic deformation capacity required, structural steel design under the current codes can be classified into three categories: elastic, plastic, and seismic design. Most of the current steel codes explicitly forbid the use of a steel material with a yield strength higher than 450 MPa in the plastic design because of the concerns about its low plastic deformation capacity as well as the lack of test data on local and lateral torsional buckling behavior. In this study, flexural tests on full-scale H-shape members built with SM490A (ordinary steel or benchmark material) and HSB800 (high-strength steel) were carried out. The primary objective was to investigate the appropriateness of extrapolating the local buckling criterion of the current codes, which was originally developed for normal-strength steel, to the case of high-strength steel. All the SM490A specimens performed consistently with the current code criteria and exhibited sufficient strength and ductility. The performance of the HSB800 specimens was also very satisfactory from the strength perspective; even the specimens with a noncompact and slender flange developed the plastic moment capacity. The HSB800 specimens, however, showed an inferior plastic rotation capacity due to the premature tensile fracture of the beam bottom flange beneath the vertical stiffener at the loading point. The plastic rotation capacity that was achieved was less than 3 (or the minimum level required for a plastic design). Although the test results in this study indicate that the extrapolation of the current flange local-buckling criterion to the case of high-strength steel is conservative from the elastic design perspective, further testing together with an associated analytical study is required to identify the causes of the tensile fracture and to establish a flange slenderness criterion that is more appropriate for high-strength steel.