• 제목/요약/키워드: analysis with repeated measurements

검색결과 139건 처리시간 0.023초

지하수위 변동에 따른 고속철도 콘크리트궤도의 침하 영향 검토 (Investigation of Settlement of Concrete Track on High-Speed Railway Due to Groundwater Variation)

  • 이현정;최영태;이일화;이민수;이태규
    • 한국철도학회논문집
    • /
    • 제20권2호
    • /
    • pp.248-256
    • /
    • 2017
  • 고속철도 콘크리트궤도의 일부 토공구간 침하 원인으로 지하수위 저하가 보고되었다. 이에 본 연구에서는 현장 계측 값과 수치해석을 통하여 지하수위 저하에 따른 침하 영향을 분석하였다. 시행착오법을 이용한 역해석을 통해 구성된 수치해석 모델을 이용하여 지하수위 저하, 연약층의 두께, 성토고에 따른 잔류침하거동을 검토하였다. 4m이상의 연약층이 존재할 경우, 지하수위 저하에 의한 원지반침하량은 30mm이상으로 예상되어 설계 및 시공단계에서 지하수위 거동에 의한 침하도 설계시 고려되어야 할 것으로 보인다.

Effect of the shades of background substructures on the overall color of zirconia-based all-ceramic crowns

  • Suputtamongkol, Kallaya;Tulapornchai, Chantana;Mamani, Jatuphol;Kamchatphai, Wannaporn;Thongpun, Noparat
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.319-325
    • /
    • 2013
  • PURPOSE. The objective of this study was to determine the effect of the color of a background substructure on the overall color of a zirconia-based all-ceramic crown. MATERIALS AND METHODS. Twenty one posterior zirconia crowns were made for twenty subjects. Seven premolar crowns and six molar crowns were cemented onto abutments with metal post and core in the first and second group. In the third group, eight molar crowns were cemented onto abutments with a prefabricated post and composite core build-up. The color measurements of all-ceramic crowns were made before try-in, before and after cementation. A repeated measure ANOVA was used for a statistical analysis of a color change of all-ceramic crowns at ${\alpha}$=.05. Twenty four zirconia specimens, with different core thicknesses (0.4-1 mm) were also prepared to obtain the contrast ratio of zirconia materials after veneering. RESULTS. $L^*$, $a^*$, and $b^*$ values of all-ceramic crowns cemented either on a metal cast post and core or on a prefabricated post did not show significant changes (P>.05). However, the slight color changes of zirconia crowns were detected and represented by ${\Delta}E{^*}_{ab}$ values, ranging from 1.2 to 3.1. The contrast ratios of zirconia specimens were 0.92-0.95 after veneering. CONCLUSION. No significant differences were observed between the $L^*$, $a^*$, and $b^*$ values of zirconia crowns cemented either on a metal cast post and core or a prefabricated post and composite core. However, the color of a background substructure could affect the overall color of posterior zirconia restorations with clinically recommended core thickness according to ${\Delta}E{^*}_{ab}$ values.

협응이동훈련이 척추 측만증 고객의 족저압과 균형에 미치는 효과 -단일사례연구- (Effect of Coordinative Locomotor Training on Balance and Plantar Foot Pressure in Scoliosis Patients -A Single Subject Study-)

  • 김진철;김태윤;이정아
    • PNF and Movement
    • /
    • 제15권3호
    • /
    • pp.227-236
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of coordinative locomotor training (CLT) on the foot pressure and balance of patients with scoliosis. Methods: This was a single-case A-B-A study involving two patients with scoliosis. The study was designed to perform repeated measurements as follows: 5 times at baseline (A), 10 times during intervention (B), and 5 times after intervention (A). The study period was 5 weeks, and the CLT program was divided into warm up, CLT program, and cool down stages, at 50 min per stage. For the primary outcome measure, Gait View AFA-50 was used to determine the foot pressure and balance ability. For the secondary outcome measure, the SRS-22 questionnaire was used to assess the quality of life of the patients with scoliosis. Descriptive statistics and visual analysis using graphs were used to compare the rates of change. Results: The results of this study showed that the foot pressure and balance ability of the two subjects improved during the intervention period and remained improved even during the baseline period. However, their quality of life did not change after the intervention. Conclusion: CLT may have a positive effect on foot pressure and balance ability in patients with scoliosis. Also, this body function improvement may have positive effects on the performance of daily activities which employ the upright position.

다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교 (Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure)

  • 송효숙;전태국;최은정;김미정
    • 기본간호학회지
    • /
    • 제8권3호
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

Color discrepancy of single-shade composites at different distances from the interface measured using cell phone images

  • Marcia Luciana Carregosa Santana;Gabriella de Jesus Santos Livi;Andre Luis Faria-e-Silva
    • Restorative Dentistry and Endodontics
    • /
    • 제49권1호
    • /
    • pp.7.1-7.11
    • /
    • 2024
  • Objectives: This study aimed to evaluate the impact of substrate color and interface distance on the color adjustment of 2 single-shade composites, Vittra APS Unique and Charisma Diamond One. Materials and Methods: Dual disc-shaped specimens were created using Vittra APS Unique or Charisma Diamond One as the center composite, surrounded by shaded composites (A1 or A3). Color measurements were taken with a spectrophotometer against a gray background, recording the color coordinates in the CIELAB color space. Illumination with a light-correcting device and image acquisition using a polarizing filter-equipped cell phone were performed on specimens over the same background. Image processing software was used to measure the color coordinates in the center and periphery of the inner composite and in the outer composite. The color data were then converted to CIELAB coordinates and adjusted using data from the spectrophotometer. Color differences (ΔE00) between the center/periphery of single-shade and outer composites were calculated, along with color changes in single-shade composites caused by different outer composites. Color differences for the inner composites surrounded by A1 and A3 were also calculated. Data were analyzed using repeated-measures analysis of variance (α = 0.05). Results: The results showed that color discrepancies were lowest near the interface and when the outer composite was whiter (A1). Additionally, Charisma Diamond One exhibited better color adjustment ability than Vittra APS Unique. Conclusions: Color discrepancies between the investigated single-shade composites diminished towards the interface with the surrounding composite, particularly when the latter exhibited a lighter shade.

Changes in body weight, blood pressure and selected metabolic biomarkers with an energy-restricted diet including twice daily sweet snacks and once daily sugar-free beverage

  • Nickols-Richardson, Sharon M.;Piehowski, Kathryn E.;Metzgar, Catherine J.;Miller, Debra L.;Preston, Amy G.
    • Nutrition Research and Practice
    • /
    • 제8권6호
    • /
    • pp.695-704
    • /
    • 2014
  • BACKGROUND/OBJECTIVES: The type of sweet snack incorporated into an energy-restricted diet (ERD) may produce differential effects on metabolic improvements associated with body weight (BW) loss. This study compared effects of incorporating either twice daily energy-controlled dark chocolate snacks plus once daily sugar-free cocoa beverage (DC) to non-chocolate snacks plus sugar-free non-cocoa beverage (NC) into an ERD on BW loss and metabolic outcomes. MATERIALS/METHODS: In an 18-week randomized comparative trial, 60 overweight/obese premenopausal women were assigned to DC (n = 30) or NC group (n = 30). Dietary intake was measured at baseline and week 18, and BW, anthropometrics, blood pressure (BP) and serum glucose, insulin and lipid concentrations were measured at baseline, and weeks 6, 12 and 18. Data were analyzed using repeated measures ANOVA. RESULTS: Using intention-to-treat analysis, women in DC and NC groups reduced energy intake (both P < 0.001) and lost $4.4{\pm}0.6kg$ and $5.0{\pm}0.9kg$ (both P < 0.001), respectively. Both groups lowered systolic and diastolic BP [DC = 2.7 (P < 0.05), 2.7 (P < 0.01); NC = 3.4 (P < 0.01), 4.2 (P < 0.01) mmHg, respectively]. Glucose and insulin concentrations decreased by 0.72 mmol/L (P < 0.001) and 13.20 pmol/L (P < 0.01) in DC group and by 0.83 mmol/L (P < 0.001) and 13.20 pmol/L (P < 0.01), respectively, in NC group. Total cholesterol increased in NC group (P < 0.05), with no significant lipid changes in DC group. There were no significant differences in biomarker outcomes between groups. CONCLUSIONS: Overweight/obese premenopausal women following an 18-week ERD that included either DC or NC sweet snack and sugar-free beverage lost equivalent amounts of BW and improved BP measurements and glucose and insulin concentrations.

The Association Between Oxidative Stress and Depressive Symptom Scores in Elderly Population: A Repeated Panel Study

  • Han, Changwoo;Lim, Youn-Hee;Hong, Yun-Chul
    • Journal of Preventive Medicine and Public Health
    • /
    • 제49권5호
    • /
    • pp.260-274
    • /
    • 2016
  • Objectives: Previous epidemiological studies about oxidative stress and depression are limited by hospital-based case-control design, single-time measurements of oxidative stress biomarkers, and the small number of study participants. Therefore, in this study, we analyzed the association between biomarker of oxidative stress and depressive symptom scores using repeatedly measured panel data from a community-dwelling elderly population. Methods: From 2008 to 2010, a total of 478 elderly participants residing in Seoul, Korea, were evaluated three times. Participants underwent the Korean version of the Short Form Generic Depression Scale (SGDS-K) test for screening depression, and urinary malondialdehyde (MDA) levels were measured as an oxidative stress biomarker. We used a generalized estimating equation with a compound symmetry covariance structure to estimate the effects of oxidative stress on depressive symptom scores. Results: A two-fold increase in urinary MDA concentration was significantly associated with a 33.88% (95% confidence interval [CI], 21.59% to 47.42%) increase in total SGDS-K scores. In subgroup analyses by gender, a two-fold increase in urinary MDA concentration was significantly associated with increased SGDS-K scores in both men and women (men: 30.88%; 95% CI, 10.24% to 55.37%; women: 34.77%; 95% CI, 20.09% to 51.25%). In bivariate analysis after an SGDS-K score ${\geq}8$ was defined as depression, the third and the fourth urinary MDA quartiles showed a significantly increased odds ratio(OR) of depression compared to the lowest urinary MDA quartile (third quartile OR, 6.51; 95% CI, 1.77 to 24.00; fourth quartile OR, 7.11; 95% CI, 1.99 to 25.42). Conclusions: Our study suggests a significant association between oxidative stress and depressive symptoms in the elderly population.

Cone Beam Computed Tomography를 이용한 상악 임플란트 식립 전후의 골밀도 변화에 관한 연구 (ASSESSMENT OF BONE DENSITY ON MAXILLA AFTER IMPLANTATION WITH CONE BEAM COMPUTED TOMOGRAPHY)

  • 최정훈;이주민;김용덕;신상훈;정인교
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권3호
    • /
    • pp.229-235
    • /
    • 2010
  • Purpose: This study examined the significance of increased bone density according to time after implantation on maxilla using demographic data with CBCT and compared the bone density between before vs. after implantation using the Hounsfield index. Materials and Methods: Twenty-five implant site on maxilla were selected. Cone-beam computerized tomography (CBCT) scans were used for the analysis. The implant sites were evaluated digitally using the Hounsfield scale with EzImplant TM and the results were compared over time. Statistical data over time was carried out to determine the correlation between the recorded Hounsfield unit (HU) over time and gender difference using repeated ANOVA. Results: The bone density of implantation site over time showed an increase in the HU mean values. Immediately after implantation, bone density was significantly increased than bone density before implantation. Until 6 month follow-up, bone density showed stable increasement. There is no significant difference on gender. Conclusions: Using CBCT, bone density increased over time after implantation on maxilla. Bone density measurements using CBCT might provide an objective assessment of the bone quality as well as the correlation between bone density and stability of implant.

Structural behavior of arch dams considering experimentally validated prototype model using similitude and scaling laws

  • Altunisik, Ahmet Can;Kalkan, Ebru;Basaga, Hasan B.
    • Computers and Concrete
    • /
    • 제22권1호
    • /
    • pp.101-116
    • /
    • 2018
  • As one of the most important engineering structures, arch dams are huge constructions built with human hands and have strategical importance. Because of the fact that long construction duration, water supply, financial reasons, major loss of life and material since failure etc., the design of arch dams is very important problem and should be done by expert engineers to determine the structural behavior more accurately. Finite element analyses and non-destructive experimental measurements can be used to investigate the structural response, but there are some difficulties such as spending a long time while modelling, analysis and in-situ testing. Therefore, it is more useful to conduct the research on the laboratory conditions and to transform the obtained results into real constructions. Within the scope of this study, it is aimed to determine the structural behavior of arch dams considering experimentally validated prototype laboratory model using similitude and scaling laws. Type-1 arch dam, which is one of five arch dam types suggested at the "Arch Dams" Symposium in England in 1968 is selected as reference prototype model. The dam is built considering dam-reservoir-foundation interaction and ambient vibration tests are performed to validate the finite element results such as dynamic characteristics, displacements, principal stresses and strains. These results are considered as reference parameters and used to determine the real arch dam response with different scales factors such as 335, 400, 416.67 and 450. These values are selected by considering previously examined dam projects. Arch heights are calculated as 201 m, 240 m, 250 m and 270 m, respectively. The structural response is investigated between the model and prototype by using similarity requirements, field equations, scaling laws etc. To validate these results, finite element models are enlarged in the same scales and analyses are repeated to obtain the dynamic characteristics, displacements, principal stresses and strains. At the end of the study, it is seen that there is a good agreement between all results obtained by similarity requirements with scaling laws and enlarged finite element models.

Gait analysis on the condition of arm swing in healthy young adults

  • Koo, Hyun-Min;Lee, Su-Young
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권3호
    • /
    • pp.149-154
    • /
    • 2016
  • Objective: The arm swing is associated with gait ability in healthy young adults. The purpose of this study was to examine the effects of arm swing during gait in healthy young adults. Design: Cross-sectional study. Methods: Forty-five subjects without any orthopedic or neurological injuries participated in this study. All subjects performed all three conditions according to the arm swing type as follows: first procedure (condition 1), walking as usual without arm swing constraint; second procedure (condition 2), constraint of dominant arm swing walking as usual; third procedure (condition 3), constraint of both arm swing walking as usual. Gait parameters such as gait velocity, stride length, cadence, step time, single limb support, and double limb support were measured in all arm swing conditions performed randomly, with the mean value obtained from three measurements. A rest period of 5 minutes was given to prevent repetition of each condition and learning effect. All data was analyzed using repeated measures ANOVA to notice the changes between arm swing conditions. Results: Within walking conditions, significant difference of gait velocity, stride length, cadence, and double limb support was noticed (p<0.05), except step time and single limb support. Gait velocity and stride length were significant reduced, and in cadence and double limb support were increased (p<0.05). Condition 3 had the most significant decrease of gait ability compared with condition 1 (p<0.05). Conclusions: These finding suggested that constraint arm swing conditions reduced gait ability in healthy young adults. Also, these findings can be utilized as a reference to future studies that not only pelvic, knee and ankle, but also upper limb affect to gait ability.