• Title/Summary/Keyword: analysis parameters

Search Result 18,206, Processing Time 0.048 seconds

Dst Prediction Based on Solar Wind Parameters (태양풍 매개변수를 이용한 Dst 예측)

  • Park, Yoon-Kyung;Ahn, Byung-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.4
    • /
    • pp.425-438
    • /
    • 2009
  • We reevaluate the Burton equation (Burton et al. 1975) of predicting Dst index using high quality hourly solar wind data supplied by the ACE satellite for the period from 1998 to 2006. Sixty magnetic storms with monotonously decreasing main phase are selected. In order to determine the injection term (Q) and the decay time ($\tau$) of the equation, we examine the relationships between $Dst^*$ and $VS_s$, ${\Delta}Dst^*$ and $VS_s$, and ${\Delta}Dst^*$ and $Dst^*$ during the magnetic storms. For this analysis, we take into account one hour of the propagation time from the ACE satellite to the magnetopause, and a half hour of the response time of the magnetosphere/ring current to he solar wind forcing. The injection term is found to be $Q(nT/h)\;=\;-3.56VS_s$ for $VS_s$ > 0.5mV/m and Q(nT=h) = 0 for $VB_s\;{\leq}\;0.5mV/m$. The $\tau$ (hour) is estimated as $0.060Dst^*\;+\;16.65$ for $Dst^*$ > -175nT and 6.15 hours for $Dst^*\;{\leq}\;-175nT$. Based on these empirical relationships, we predict the 60 magnetic storms and find that the correlation coefficient between the observed and predicted $Dst^*$ is 0.88. To evaluate the performance of our prediction scheme, the 60 magnetic storms are predicted again using the models by Burton et al. (1975) and O'Brien & McPherron (2000a). The correlation coefficients thus obtained are 0.85, the same value for both of the two models. In this respect, our model is slightly improved over the other two models as far as the correlation coefficients is concerned. Particularly our model does a better job than the other two models in predicting intense magnetic storms ($Dst^*\;{< \atop \sim}\;-200nT$).

New Analytical Method to Identify Chromium Species, Cr(III) and Cr(VI), and Characteristic Distribution of Chromium Species in the Han River (한강수계해서의 크롬(III,VI) 종(species) 분포 및 분석방법 정립)

  • Jeong, Gwan-Jo;Kim, Dok-Chan;Park, Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.590-598
    • /
    • 2005
  • An adequate method to identify chromium separation, Cr(III) and Cr(VI), in water samples were studied by using High Performance Liquid Chromatography(HPLC) coupled with Inductively Coupled Plasma Mass Spectometer(ICP-MS) equipped with Dynamic Reaction Cell(DRC). The characteristic distribution of Cr(III) and Cr(VI) in the raw water taken at the six water intake stations in Seoul, was analyzed by the method developed by the authors. The chromium species separated by HPLC was isocratically conducted by using tetrabutylammonium phosphate monobasic(1.0 mM TBAP), ethylenediaminetetraacetic acid(0.6 mM EDTA) and 2% v/v methanol as the mobile phase. 5% v/v methanol was used as flushing solvent. A reactive ammonia($NH_3$) gas was used to eliminate the potential interference of $ArC^+$. Several Parameters such as solvent ratio, pH, flow rate and sample injection volume were optimized for the successful separation and reproducibility. Although it has been reported thai the separation sensitivity of Cr(III) is superior to that of Cr(VI), the authors observed Cr(VI) was more sensitive than Cr(III) when ammonia($NH_3$) gas was used as the reaction gas. It took less than 3 minutes to analyze chromium species with this method and the estimated detection limits were $0.061\;{\mu}g/L$ for Cr(III) and $0.052\;{\mu}g/L$, for Cr(VI). According to the results from the analysis on chromium species in the raw water of the six intake stations, the concentrations of Cr(III) ranged from 0.048 to $0.064\;{\mu}g/L$(ave. $0.054\;{\mu}g/L$) while that of Cr(VI) ranged from 0.014 to $0.023\;{\mu}g/L$(ave. $0.019\;{\mu}g/L$). Recovery ratio was very high($90.1{\sim}94.1%$). There were two or three times more Cr(III) than Cr(VI) in the raw water.

Analysis of Distribution Characteristics of Flowrate and Water Quality in Tributary at Chungcheongnam-do (충청남도 지류하천의 유량 및 수질 분포특성 분석)

  • Park, Sang-Hyun;Moon, Eun-Ho;Choi, Jeong-Ho;Cho, Byung-Wook;Kim, Hong-Su;Jeong, Woo-Hyeok;Yi, Sang-Jin;Kim, Young-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.739-747
    • /
    • 2011
  • The major 81 tributaries in Chungcheongnam-do were monitored for flowrate and water quality in order to understand the characteristics of the watershed and to select the tributary catchment for improving water quality. The value of flowrate in the tributaries at Nonsancheon catchment at the Geum-River watershed and Gokgyocheon, Muhancheon, Sapgyocheon at the Sapgyo-Reservoir watershed, which is located in the southern and northern area in Chungcheongnam-do, was relatively greater than the other watersheds. The concentration of water pollutants regardless of water quality parameters in Nonsancheon catchment at the Geum-River watershed, Gokgyocheon catchment at the Sapgyo-Reservoir watershed and the Anseongcheon watershed, which have a dense source of pollution, were higher than the other watersheds. However, 64 percent of the tributaries at the Geum-River watershed, 45 percent of tributaries at the Sapgyo-Reservoir watershed, 26 percent of tributaries at the Geum-River watershed all satisfied the Class II regulations in the Framework Act on Environment Policy, but all of the tributaries located in the Anseongcheon watershed exceeded the Class II regulations. Therefore, the policy for improving the water quality of the tributary in Chungcheongnam-do should be established in the following order: Anseongcheon, Seohae, Sapgyo-Reservoir watersheds. Consequently, the tributary catchment for improving water quality, which has a large flowrate and a high concentration of water pollutants, was selected at Ganggyeongcheon, Geumcheon, Nonsancheon, Seokseongcheon, Seungcheoncheon, Jeongancheon, Jeungsancheon (so far Geum-River watershed), Gokgyocheon, Namwoncheon, Maegokcheon, Muhancheon, Sapgyocheon Oncheoncheon, Cheonancheon (so far Sapgyo-Reservoir watershed), Gwangcheoncheon, Dangjincheon, Daecheoncheon, Dodangcheon, Waryongcheon, Cheongjicheon, Pangyocheon, Heungincheon (so far Seohae watershed), Dunpocheon, Seonghwancheon, Ipjangcheon (so far Anseongcheon watershed). The plans as installation of environmental facilities to reduce the source of pollution for improving the water quality of these tributary catchments should be urgently established and implemented.

Use of Tributary Water Quality and Flowrate Monitoring Data for Effective Implementation of TMDL (수질오염총량관리제의 효율적인 시행을 위한 지류하천 수질.유량모니터링 자료의 활용)

  • Kim, Young-Il;Jeong, Woo-Hyeok;Kim, Hong-Su;Yi, Sang-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.2
    • /
    • pp.119-125
    • /
    • 2012
  • The tributary water quality and flowrate monitoring result, which is fundamental data for the establishment of the water environmental policy, is used as very important data for the implementation of TMDL. This study introduced how to use the tributary water quality and flowrate monitoring data for the analysis of the watersheds, the satisfactory assessment of water quality standards in the watersheds, the selection of watersheds for the establishment of the implementation plan, and the selection of the tributary catchments for improving the water quality using a stream grouping method. According to the analytical results of tributary catchment using water quality and flowrate monitoring data of thirty-seven tributaries in the Geum-River watershed at Chungcheongnam-do, the value of flowrate in the tributaries, which is located in the middle-lower Geum-River watershed, was greater than the other areas and the concentration of the water pollutants regardless of water quality parameters in the tributaries at Nonsancheon catchment was relatively higher than the other areas. The problems, which have the determination of satisfaction of water quality standards and selection of target watersheds for establishment of the implementation plan regardless of the water quality of tributary in the watershed due to the water quality and flowrate monitoring results of the main river, were improved use of the results of tributary water quality and flowrate monitoring. Also, the tributary catchments for improving the water quality, according to stream grouping method based on the results of tributary water quality and flowrate monitoring, were selected. In the Geum-River watershed at Chungcheongnam-do, the tributary in the Nonsancheon, Byeongcheoncheon, Seokseongcheon, Jocheon catchments, which has a large flow and a high concentration of water pollutants, should be preferentially selected for improving the water quality of the tributary in accordance with the reduction of the source of pollution.

The impact college students' sexual assault awareness has on the sexual assault experience :Mediating effects of the sexual violence allowance scale (대학생의 성폭력 인식도가 성폭력 피해경험에 미치는 영향 : 성폭력 허용도의 매개효과)

  • Kang, cha-sun;Jung, Min;Yoem, Soon-Joung;Park, Jeong-hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.551-560
    • /
    • 2016
  • The aim of this study was to verify the effect of the parameters in relation to college students' awareness of sexual assault and sexual violence experience. The subjects were 408 male and female college students attending four universities located in Jeju island. Sexual assault awareness measures, sexual violence experience scale, and the scale of sexual violence allowance scale were used in the questionnaires. First, correlation analysis showed a significant negative correlation between sexual violence awareness and sexual violence. Also, sexual violence awareness and sexual violence allowance scale showed a considerable negative correlation. This suggests that the higher the sexual assault awareness, the lower the sexual damage and sexual violence allowance scale. Second, after analyzing the division of the subject into research model and competition model to verify the mediation effect in relationship of the sexual violence awareness and sexual violence experience, it was clear that sexual awareness does not have a direct effect on the experience of sexual damage. It rather mediated the sexual violence allowance scale. Therefore, the research model, which is the full mediation model, was selected. In other words, sexual assault awareness appeared to fully mediate the relationship between sexual assault awareness and sexual assault experience. This means that sexual assault perception has an indirect influence through sexual assault allowance rather than a direct effect on the sexual assault experience. Thus, the more well established that sexual assault awareness is, the lower the sexual assault allowance scale. Finally, the lowered sexual assault allowance scale could reduce the sexual assault harm. To improve the sexual assault recognition, a systematic sexual violence prevention education should be conducted. Sexual assault prevention education would allow students in dating relationships to become mature in their human rights and maintain the proper emotional relationship and enable a reduction in the harm sexual assault as a result of giving them the consideration. Finally, this study had a limitation in selecting the subjects as the college students living in Jeju. Therefore, in order to compensate for this limitation, follow-up studies should be carried out on with a sample of generalized and various research subjects.

Flip Angle of the Optimal T1 Effect Using FLASH Pulse Sequence at 3T Abdominal MRI (FLASH를 이용한 3T 복부검사에 있어서 최적의 T1효과를 위한 적정 Flip Angle)

  • Han, Jae-Bok;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.101-106
    • /
    • 2009
  • Purpose of this study is to compare the signal intensity (SI) and CNR with T1 weighted image using FLASH at 3T abdominal MRI by varying flip angle (FA). Totally 20 patients (male : 12, female : 8, Age : $28{\sim}63$ years with mean : 51) were examined by 3 Tesla MR scanner (Magnetom Tim Trio, SIEMENS, Germany) with 8 channel body array coil between september and October 2008. Imaging parameters were as follows : FLASH sequence, TR : 120 ms, TE : minimum, FOV (field of view) : $360{\times}300\;mm$, Matrix : $256{\times}224$, slice : 6 mm, scan time : 15 sec and Breath-hold technique. Abdominal image, with a 50 ml syringe filled with water placed in the FOV measuring the water signal, were acquired with varying FA through $10^{\circ}$ to $90^{\circ}$ with $10^{\circ}$ interval. SI's were measured three times at liver parenchyme, water, spleen and background and averaged. The CNR's were measured between the ROIs (region of interest). Statistic analysis was performed with ANOVA test using SPSS software (version 17.0). Less than FA $30^{\circ}$, abdominal images were severely inhomogeneity. Especially, T1 effect of water signal was weak. As the flip angle increased, the signal intensity decreased at all the regions. Especially, flip angle of the highest signal intensity was observed with $40^{\circ}$ at the liver parenchyme, $20^{\circ}$ at water, $30^{\circ}$ at the spleen, respectively. The CNR between liver and water was -60.92 at FA $10^{\circ}$ and 15.16 at FA $80^{\circ}$. The CNR between liver and spleen was -3.18 at FA $10^{\circ}$ and 9.65 at $80^{\circ}$. In conclusion, FA $80^{\circ}$ is optimal for T1 weighted effect using FLASH pulse sequence at 3.0 T abdominal MRI.

  • PDF

The Occupant Perception and Investigation of Indoor Air Quality at Home in Seoul

  • Sohn, Jong-Ryeul;Kim, Young-Whan;Byeon, Sang-Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 2003
  • Indoor air quality(IAQ) in workplace and residential environments has been concern of people. Recently, Ministry of Environment in Korea has recognized the potential risk on the healthy effect related to indoor air pollution at home. Therefore, the purpose of this study was performed to measure the indoor air pollutants of IAQ at different homes and investigate to compare the perception of IAQ recognition at home from questionnaire survey in Seoul. We estimated the IAQ of selected 6 homes based on site region and housing type. The indoor air pollutants and parameters such as temperature, relative humidity, respirable suspended particulate matter($PM_{10}$), formaldehyde(HCHO), total bacteria counts, carbon monooxide(CO) and carbon dioxide($CO_2$) were monitored for summer and winter. In monitoring results, the respirable suspended particulate matter(($PM_{10}$) and indoor airborne bacteria level of home 5 and 6 were higher than the standard of the public $150{\;}{\mu}g/m^3$ and $500{\;}{\mu}g/m^3$, the level formaldehyde(HCHO) was exceed 0.1 ppm of the standard of Korea at all monitored homes. In statistics analysis, we could find a correlation between the building age and the concentration of CO, TBC were significant at 0.01 level and Relative Humidity was significant at 0.05 level for summer. Finally, the important air pollutants of IAQ in home were HCHO and total bacteria counts(TBC). And we performed a questionnaire survey of 500 people about their awareness for the importance of IAQ in our home during same period. In results, all most response of occupant has recognized the importance of IAQ at home. Therefore, it can be concluded that the IAQ of selected 6 home studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems, and the occupants need to be effort to reduce the exposure of sources to undesirable pollutants.

Study on the Physical and Mechanical Properties of Particleboard and Oriented Strandboard Manufactured by Tulliptree (Liriodendron tulipifera L.) (백합나무를 이용하여 제조한 3층 파티클보드와 배향성 스트랜드보드(OSB)의 물성에 관한 연구)

  • Seo, Jun won;Gang, Gil woo;Jo, Gun hee;Park, Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.67-72
    • /
    • 2018
  • This study was conducted to investigate a potential of Yellow poplar (Liriodendron tulipifera L.) as a raw material for the manufacturing of particleboard (PB) and oriented strandboard (OSB). PB panels were prepared at the parameters of $0.7g/cm^3$ density, 15 mm thickness, three-layer, $E_1$ grade urea-formaldehyde (UF) resin, emulsion wax, and hardener. OSB panels were manufactured with a density of $0.65g/cm^3$, thickness of 10 mm, and $E_1$ grade of UF resin. Particle size of the face layer of PB was 20~80 mesh with 7~9% moisture content (MC), while that of core-layer was 3~20 mesh with 3~5% MC, which was similar to the production condition of commercial PB. As a result, the manufactured PB panels with 15.8 mm thickness, $0.7g/cm^3$ density, and 5.8% MC satisfied the requirement of bending strength of 15 type PB of Korean Industrial Standard (KS F 3104). Both internal bonding (IB) strength and surface screw withdrawal resistance also satisfied the requirement of 18 type PB of the standard. But, the edge screw withdrawal resistance satisfied the requirement of 15 type PB of the standard. These differences in properties could be due to the slenderness ratio of raw particles. In case of OSB panels with 10.7 mm thickness, $0.68g/cm^3$ density, and 5.8% MC satisfied all the requirements of bending strength, screw withdrawal resistance, and IB strength of 18 type PB of the standard. These results suggest that Yellow poplar wood has a good potential as a raw material for the production of PB and OSB.

A Web-based 'Patterns of Care Study' System for Clinical Radiation Oncology in Korea: Development, Launching, and Characteristics (우리나라 임상방사선종양을 위한 웹 기반 PCS 시스템의 개발과 특성)

  • Kim, Il Han;Chie, Eui Kyu;Oh, Do Hoon;Suh Chang-Ok;Kim, Jong Hoon;Ahn, Yong Chan;Hur, Won-Joo;Chung, Woong Ki;Choi, Doo Ho;Lee, Jae Won
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.291-298
    • /
    • 2003
  • Purpose: We report upon a web-based system for Patterns of Care Study (PCS) devised for Korean radiation oncology. This PCS was designed to establish standard tools for clinical quality assurance, to determine basic parameters for radiation oncology processes, to offer a solid system for cooperative clinical studies and a useful standard database for comparisons with other national databases. Materials and Methods: The system consisted of a main server with two back-ups in other locations. The program uses a Linux operating system and a MySQL database. Cancers with high frequencies in radiotherapy departments in Korea from 1998 to 1999 were chosen to have a developmental priority. Results: The web-based clinical PCS .system for radiotherapy in www.pcs.re.kr was developed in early 2003 for cancers of the breast, rectum, esophagus, larynx and lung, and for brain metastasis. The total number of PCS study items exceeded one thousand. Our PCS system features user-friendliness, double entry checking, data security, encryption, hard disc mirroring, double back-up, and statistical analysis. Alphanumeric data can be input as well as image data. In addition, programs were constructed for IRB submission, random sampling of data, and departmental structure. Conclusion: For the first time in the field of PCS, we have developed a web-based system and associated working programs. With this system, we can gather sample data in a short period and thus save, cost, effort and time. Data audits should be peformed to validate input data. We propose that this system should be considered as a standard method for PCS or similar types of data collection systems.

Changes of Microbial Activity and Physicochemical Environment during Composting of Papermill Sludge in a Pilot Plant (제지슬럿지의 퇴비화 과정 중 미생물활성 및 이화학적 환경변화)

  • Chung, Young-Ryun;Chung, Man-Hoon;Han, Shin-Ho;Oh, Say-Kyun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.3 no.2
    • /
    • pp.79-89
    • /
    • 1995
  • Changes of microbial activity and physicochemical environment during composting of papermill sludge(PMS) in the pilot plant equipped with an agitated bed reactor were monitored for establishing the efficient composting system. Microbial activity determined as the evolution of $CO_2$ increased for the first 10 days after introduction of PMS to the reactor and decreased thereafter. Population changes of microorganisms in the reactor-PMS were not typical as in windrow system. The ratio of thermophilic bacteria to mesophilic bacteria, however, increased slowly even 23 days after introduction. Temperature of PMS increased rapidly from the first day and reached $62^{\circ}C$ at 7 days after introduction and decreased slowly thereafter. The acidity of PMS was pH 6.8 initially, increased to pH 8.0 after 7 days and decreased to pH 7.4 after 23 days. Redox potential(Eh) of PMS was -320mV at the beginning of composting, but it was increased with time to reach -15mV after 23 days composting. However, Eh of PMS pre-sterilized before measurement was average 50mV, regardless of composting periods indicating the major role of microorganisms during composting process. Water content of PMS was 67% initially and decreased to about 50% after 23 days composting in the reactor. Less than 13 days-old compost inhibited growth of radish in the container mixture with bed soil. Based on statistical analysis of microbial and physicochemical parameters of PMS during composting, an equation was developed for determining compost maturity. A number of experiments using various organic wastes are required before application of the formular to the practical use.

  • PDF