• 제목/요약/키워드: analysis of optimal operating condition

검색결과 101건 처리시간 0.031초

이중외피 건물 난방시스템의 발정제어 및 가변제어를 위한 최적로직의 개발 및 성능평가 (Development and Performance Evaluation of Optimal Control logics for the Two-Position- and Variable-Heating Systems in Double Skin Facade Buildings)

  • 백용규;문진우
    • KIEAE Journal
    • /
    • 제14권3호
    • /
    • pp.71-77
    • /
    • 2014
  • This study aimed at developing and evaluating performance of the two logics for respectively operating two-position- and variable-heating systems. Both logics control the heating system and openings of the double skin facade buildings in an integrated manner. Artificial neural network models were applied for the predictive and adaptive controls in order to optimally condition the indoor thermal environment. Numerical computer simulation methods using the MATLAB (Matrix Laboratory) and TRNSYS (Transient Systems Simulation) were employed for the performance tests of the logics in the test module. Analysis on the test results revealed that the variable control logic provided more comfortable and stable temperature conditions with the increased comfortable period and the decreased standard deviation from the center of the comfortable range. In addition, the amount of heat supply to the indoor space was significantly reduced by the variable control logic. Thus, it can be concluded that the optimal control method using the artificial neural network model can work more effectively when it is applied to the variable heating systems.

Complete and Incomplete Observability Analysis by Optimal PMU Placement Techniques of a Network

  • Krishna, K. Bala;Rosalina, K. Mercy;Ramaraj, N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1814-1820
    • /
    • 2018
  • State estimation of power systems has become vital in recent days of power operation and control. SCADA and EMS are intended for the state estimation and to communicate and monitor the systems which are operated at specified time. Although various methods are used we can achieve the better results by using PMU technique. On placing the PMU, operating time is reduced and making the performance reliable. In this paper, PMU placement is done in two ways. Those are 'optimal technique with pruning operation' and 'depth of unobservability' considering incomplete and complete observability of a network. By Depth of Unobservability Number of PMUs are reduced to attain Observability of the network. Proposed methods are tested on IEEE 14, 30, 57, SR-system and Sub systems (1, 2) with bus size of 270 and 444 buses. Along with achieving complete observability analysis, single PMU loss condition is also achieved.

전기분해공정을 이용한 유기물저감 및 수소 생산을 위한 최적 조건에 관한 연구 (A Study on Optimal Conditions for Organic Matter Reduction and Hydrogen Production Using Electrolysis Process)

  • 안정윤;노연희;장순웅
    • 한국수소및신에너지학회논문집
    • /
    • 제31권6호
    • /
    • pp.546-552
    • /
    • 2020
  • In this study, optimization research was conducted through statistical analysis with the aim of maximizing the efficiency of organic matter reduction and hydrogen production by applying electrolysis process at sewage treatment plant. Statistical analysis and optimal operating conditions of organic matter removal efficiency and H2 generation, which varied with various conditions in the electrolysis process, were derived using response surface methodology. As a result, 1,268 μS/cm of conductivity, 350 A current, and pH 3.2 was found to be the optimum condition to reach the desired value as 38% of organic matter reduction and 2.58 L/min of H2 production. The experiment also determined that the optimization study was reliable. Base on this study, it was confirmed that the removal of organic matter and hydrogen production could be stably by applying the electrolysis process in the sewage treatment plant.

암모니아 유니트 쿨러의 열성능 해석 (Analysis on the Thermal Performance of an Ammonia Unit Cooler)

  • 최재광;김무근;박병규
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1125-1133
    • /
    • 2001
  • Since the surface temperature of the evaporating tube in an ammonia unit cooled is lower than the dew point of atmosphere, the moisture in the atmosphere condenses and the frost grows on the tube. The frost of liquid film decreases the heat transfer rate. The reliable analysis of the heat transfer is required for the prediction of the optimal design of the ammonia unit cooler. For the specific commercial model, the performance was numerical1y estimated for the variation of operating condition and geometric configuration. It is found that there exists an optimum range for the parameters such as mass flow rate of air and refrigerant, humidity, refrigerant quality, fin pitch, the number of step, the number of rows and the pattern of refrigerant path.

  • PDF

와이어코일 삽입법을 이용한 열전달 촉진기술 성능평가 (Evaluation of Heat Transfer performance of Wire-coil Inserted Tube)

  • 이주동;박종호;이상천
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.457-465
    • /
    • 2000
  • An experiment was carried out to evaluate the thermal performance of the wire-coil inserts method. Tested were the smooth tubes with the wire-nil inserts of various pitch and helix angle combinations. Test fluids were the 50%-solution of the ethylene glycol and the Hue water. Heat transfer coefficient and friction factors were deduced from the measured values of temperatures, flowrates and pressure drops. A unified dimensionless correlation for the heat transfer coefficients was developed as a function of the pitch to diameter ratio, the Reynolds number and the Prandtl number. An exergy analysis was performed to evaluate an optimal operating condition with the wire-coil inserts.

  • PDF

컴퓨터 시뮬레이션을 이용한 리니어 피더의 설계 및 분석 (Design and Analysis of a Linear Feeder using Computer Simulation)

  • 이규호;김성현;정진태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.749-753
    • /
    • 2007
  • The purpose of this study is to design of a linear feeder using a multi body dynamic program, and to analyze a dynamic motion of the feeder that can transport small mechanical parts uniformly. In order to establish the analysis model of the linear feeder, each parts of the feeder are divided into two types which the rigid and flexible body. For the dynamic simulation, RecurDyn, which is a commercial multi-body dynamic package, is used. We also consider the design parameters for optimal dynamic motion such as centroid, stiffness, and mass of the feeder system. In order to analyze the dynamic motion of a linear feeder, the displacements of the feeder are measured by several accelerometers when it is in an operating condition. After the signal data from the accelerometers are captured in the time domain, the dynamic motion in the space is visualized by using graphic computer software.

  • PDF

환경${\cdot}$에너지 시스템에 관한 수치해석적 연구 : SNCR, 보텍스튜브 (Numerical Study on Energy and Environmental System : SNCR, Vortex Tube)

  • 장동순;신나일;서재동;신미수;엄태인;김동찬
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 춘계 학술대회논문집
    • /
    • pp.162-170
    • /
    • 1999
  • Numerical study has been peformed to develop a computer code for the design & optimal operating condition of SNCR(Selective Noncatalytic Reactor) for NOx reduction together with the analysis of the performance of vortex tube. Especially for the SNCR of the scale of industrial boiler, the required mixing and residence time of $NH_3$ solution was successfully tested numerically by the implementation of some baffle setups in a combustor. The introduction of interesting phenomena of vortex tube and similar system is made together with a theoretical hypothesis and simple cold flow simulation for the flow field analysis.

  • PDF

특수 압력요기용 안전밸브의 2중 구조로 디스크의 최적설계 (Optimal Design of Dual-Structured Disc of a Safety-Valve for the Specialized Pressure Vessel Considering Thermal Expansion)

  • 김창호
    • 한국기계가공학회지
    • /
    • 제6권4호
    • /
    • pp.81-85
    • /
    • 2007
  • A safety valve is used for protecting the pressure vessel and facilities by discharging the operating fluid into the valve from the accident when the pressure is over the designated value. The fluid is sulfurous acid and nitric acid. etc. in the semi-conductor assembly line. Thus the valve elements material must be acid resistance. Teflon, which is used generally as inner parts of a valve, tends to easily sticks to sliding surface by thermal expansion under high temperature. Some studies are performed to change teflon to another material and shape to have a better fluidity under the condition. The analysis of the thermal expansion is conducted by commercial FEM software to improve the problems. Boundary conditions were temperature and load in this study. From the analysis, the thermal expansion of stainless steel is verified to be lower than that of teflon under high temperature. Thus coupled teflon/stainless steel-made valve is applied to assembly line without danger due to thermal expansion.

  • PDF

유기성 슬러지 양생장치의 건조특성 (The Charncteristics of Organic Sludge in Curing Equipment)

  • 정호윤;박재성;강진수;윤희철;이연원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3173-3177
    • /
    • 2007
  • Recently, we have many problems on the process of the sludge. In past, the sewage sludge was treated by reclaimed land or thrown away in the sea. But these methods caused environmental pollution. Today, many researchers are studying various methods for reducing its volume. One of these method, this study is to reduce the moisture of sewage sludge and to solidify it using a dryer and curing equipment. In this research, we investigated about design parameter and operation condition of the equipment. The curing equipment reduces the percentage of water content from 30% of dryer to 10%. So, we have to study the curing characteristics and performance of curing equipment. For example, there are internal flow characteristics and change of the percentage of water content. And we investigated the change of data at outlet along the initial condition, temperature, humidity and air flow. Using this data, we achieve the experimental results of curing efficiency by each geometry and operating condition. And we also investigated numerical analysis of internal flow using CFD code. This research is basic study for optimal design of the curing equipment.

  • PDF

실제 날씨를 고려한 PV-MPPT 제어기의 최적 주기와 변량전압 (Optimum Control Period and Perturbation Voltage for PV-MPPT Controller Considering Real Wether Condition)

  • 류단비;김용중;김효성
    • 전력전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.1-5
    • /
    • 2020
  • Solar power generation systems require maximum power point tracking (MPPT) control to operate PV panels at their maximum power point (MPP). Most conventional MPPT algorithms are based on the slope-tracking concept. A typical slope-tracking method is the perturb and observe (P&O) algorithm. The P&O algorithm measures the current and voltage of a PV panel to find the operating point of the voltage at which the calculated power is maximized. However, the measurement error of the sensor causes irregularity in the calculation of the generated power and voltage control. This irregularity leads to the problem of not finding the correct MPP operating point. In this work, the power output of a PV panel based on the P&O algorithm is simulated by considering the insolation profiles from typical clear and cloudy weather conditions and the errors of current and voltage sensors. Simulation analysis suggests the optimal control period and perturbation voltage of MPPT to maximize its target efficiency under real weather conditions with sensor tolerance.