• 제목/요약/키워드: analysis of optimal operating condition

검색결과 101건 처리시간 0.031초

공기식 태양광/열 시스템 공기채널 내 여러 저항체 설치에 따른 전열성능에 관한 CFD 해석 (CFD Analysis on the Heat Transfer Performance with Various Obstacles in Air Channel of Air-Type PV/Thermal Module)

  • 최휘웅;파쿠르 로커만;김영복;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제38권2호
    • /
    • pp.33-43
    • /
    • 2018
  • PV/Thermal module is the combined system, which consist of a photovoltaic module and solar thermal collector that can obtain electrical power and thermal energy simultaneously. Thus the power generation can be increase by decreasing the temperature of photovoltaic module and thermal energy retrieved from module also can be used for heating system. In this study, Heat transfer performance of air type PV/Thermal module was confirmed with various bottom obstacles that can be installed easily to real photovoltaic module by CFD (computational fluid dynamics) analysis. Eight type obstacles were investigated according to the shape and arrangement. As a result, nusselt number represent heat transfer performance was increased about 86% compare with the basic type PV/Tthermal module that has no obstacle and triangle type obstacle had higher value than other types. But pressure drop was also increased with increment of heat transfer enhancement. Thus the performance factor considering both heat transfer and pressure drop was confirmed and V-fin type obstacle arranged in a row for Reynolds number below 9,600 and protrusion type obstacle arranged in zigzag for Reynolds number above 14,400 were shown higher performance factor than other types. From these results, V-fin type obstacle arranged in row and protrusion type obstacle arranged in zigzag were considered as a proper type for applying to real PV/thermal module according to operating condition. But the heat transfer performance can be changed by the geometric conditions of obstacle such as height, width, length and arrangement. Thus, it could also confirmed that the optimal condition and arrangement of this obstacle need to be found in further study.

원심펌프 회전차 Modification시 성능개선에 관한 유동해석 연구 (A Fluid Analysis Study on Centrifugal Pump Performance Improvement by Impeller Modification)

  • 이아영;장현준;이진우;조원정
    • 한국가스학회지
    • /
    • 제24권2호
    • /
    • pp.1-8
    • /
    • 2020
  • 원심펌프는 통상적으로 임펠러를 고속으로 회전시켜 원심력을 통해 유체 에너지를 전달하는 설비로서 기화용 해수펌프, 공업용수 및 해수를 사용하는 소화펌프 등 많은 LNG 생산기지에서 사용하고 있는 주요 프로세스 설비이다. 현재 LNG 플랜트 현장에서의 펌프는 장기간 수요처가 원하는 공급량에 따라 운전조건이 변동되어 펌프의 성능이 저하되고 있다. 특히 펌프는 플랜트 현장에서 소비 전략량의 많은 부분을 차지하고 있어, 최적의 운전조건을 찾지 못한다면 장기간 플랜트 운영 시 막대한 에너지 손실비용을 발생할 수 있다. 이러한 문제점을 해결하기 위해 펌프의 운전조건별 변동에 따른 유동해석 및 결과분석을 통하여 성능저하 요인을 파악하고 최적의 운전조건을 확인하는 기술이 필요하다. 실험기법을 통해 운전 효율성 평가를 하기 위해서는 현장의 운전조건과 실험장비 제작 등 상당한 시간과 비용이 발생되기 때문에 신속하고 정확한 전산유체역학(CFD) 기법을 활용하여 본 연구에서 결과를 도출하였다. 펌프의 성능이 현장의 사정에 맞지 않아 펌프 성능을 줄일 필요가 있는 경우, 회전수에 변화를 주거나 고점도 혹은 고형물이 함유된 특수액을 사용하는 방법 등이 사용된다. 특히 LNG 생산기지의 설비운영에 차질이 발생하지 않도록 하기 위해 단시간 내에 펌프의 기존 임펠러를 가공하여 필요한 성능 조건을 만족시키는 기술이 필요하다. 따라서 본 연구에서는 펌프의 기존 회전차를 가공한 3D 모델링 형상을 적용하여 ANSYS CFX 프로그램으로 유동해석을 수행하였다. 유동해석 결과와 MATLAB 프로그램의 Curve Fitting Toolbox를 활용하여 수치 해석적으로 분석하여 회전차 외경수정 이론식을 검증하였다.

폐촉매 부산물로부터 대체 응집제 제조 및 응집성능 평가 (Production of Alternative Coagulant Using Waste Activated Alumina and Evaluation of Coagulation Activity)

  • 이상원;문태섭;김효수;최명원;이대선;박상태;김창원
    • 대한환경공학회지
    • /
    • 제36권7호
    • /
    • pp.514-520
    • /
    • 2014
  • 본 연구에서는 상용 응집제와 동일한 응집 성능을 확보할 수 있는 대체 응집제(황산알루미늄 용액)의 제조 가능성을 평가하였다. 사용된 대체 응집제 원료는 폴리머 제조 공정에서 발생하는 폐촉매 부산물(Waste activated alumina)이며, 대체 응집제는 1) 강열 및 분쇄, 2) 황산과의 화학적 중합 및 치환 반응, 3) 용해 및 희석, 4) 침전 및 분리과정을 거쳐 제조되었다. 실험실 규모의 autoclave 및 용해조에서의 최적 운전 조건을 도출하기 위해 황산 순도, 반응 온도, 황산 주입비 및 용해조에서의 물 주입비의 변화 등에 따른 대체 응집제 내 $Al_2O_3$ 함량이 분석되었다. 연구 결과, 황산 순도 50%, 반응 온도 $120^{\circ}C$, 황산 주입비 5배 및 용해조 물 주입비 2.5배의 조건하에서, 7~8% 범위의 $Al_2O_3$ 함량을 가지는 대체 응집제가 제조된다는 것이 확인되었다. 대체 응집제의 응집 성능을 평가하기 위해 호기조 유출수를 대상으로 Jar-test를 수행한 결과, Al/P의 몰비를 1.5 및 2.0으로 주입한 두 가지 경우 모두에서 기존 응집제의 인 제거 성능과 유사하거나 더 높은 제거 성능이 확인되었다. 추가적으로 경제성 평가를 통해 상용 응집제와 비교했을 때 50% 이상의 생산 단가 절감이 가능하였고, 생태독성 평가를 통해 환경적 문제없이 대체 응집제가 실제 하수처리장 또는 폐수처리장에 적용될 수 있는 것이 확인되었다.

폐플라스틱의 열분해 시 열중량 분석 및 동역학 연구 (A Kinetic Studies of the Pyrolysis of Waste Plastic Based on the Thermogravimetic Analyses)

  • 정원학;황현욱;김명균;순지엔펑;느지오카 안토니 무투아;김영주
    • 자원리싸이클링
    • /
    • 제24권5호
    • /
    • pp.15-21
    • /
    • 2015
  • 폐플라스틱은 조성뿐만 아니라 다양한 플라스틱의 종류로 인하여 열분해 및 연소 속도가 달라진다. 본 연구는 폐플라스틱 고체 연료 (Refused Plastic Fuel)의 열분해 및 연소 시 설계요소 도출을 위한 열중량 분석 및 동역학 특성을 규명하였다. 열중량 분석기 (Thermogravimetric analysis)의 결과을 이용하여 동력학 특성 중 가장 일반적인 방법인 Kissinger 방법을 통하여 활성화 에너지를 구하였다. TGA의 실험 조건은 다음과 같이 설정하였다. 질소 가스유량 20 ml/min, 승온 속도 $5{\sim}50^{\circ}C/min$ 및 최대온도는 $800^{\circ}C$로 하였다. 본 연구의 폐플라스틱 열분해 특성 연구를 위하여 적용된 방법은 실제의 반응기에서 반응기의 성능, 설계 및 최적 운전조건을 결정할 때 기초자료로 사용될 수 있을 것으로 사료된다.

다상유동 전산모사를 통한 공학 규모의 cathode processor의 성능평가 (Performance Evaluation to Develop an Engineering Scale Cathode Processor by Multiphase Numerical Analysis)

  • 유병욱;박성빈;권상운;김정국;이한수;김인태;이종현
    • 방사성폐기물학회지
    • /
    • 제12권1호
    • /
    • pp.7-17
    • /
    • 2014
  • 용융염 전해정련공정은 사용후핵연료로부터 전기화학적인 방법을 통해 음극에서 우라늄을 회수 하는 공정이다. 이 때 우라늄은 약 30wt%의 염을 포함하고 있어 순수한 우라늄을 얻기 위해서는 염을 제거하는 Cathode Process (CP)가 필수적이다. CP는 대량의 우라늄을 처리해야 하므로 파이로공정의 난관중의 하나로 인식되고 있으며, 우라늄의 순도가 최종적으로 결정되는 단계이므로 매우 중요한 공정이다. 현재, 이에 대한 연구는 주로 실험적 방법에 근거 하고 있어 염 제거 공정 중 온도, 압력, 염 가스의 거동을 관찰하기 어렵다. 따라서 본 연구에서는, 공정의 운전 조건에 대해 적합한 수학적 모델을 이용하여 전산모사 해석을 진행하였다. 본 연구는 증류부에서 염 가스의 증류 량, 확산계수에 의해 계산된 장치 내 염 가스의 이동 그리고 응축부에서의 응결속도를 중점적으로 연구하였다. 장치내의 각각의 염 가스 거동을 정의하기 위해 Hertz-Langmuir 관계식, Chapman-Enskog Theory, ANSYS-CFX의 상용 코드를 사용하였다. 그리고 HSC Chemistry에서 염의 물성 값을 이용하여 모델을 구성하였다. 본 연구의 전산모사 해석을 통해 얻은 연구 결과를 이용하여 염 가스의 거동과 장치의 최적 운전조건을 예측하였다. 따라서 본 해석 결과는 CP의 물리적 현상을 깊게 이해하는데 쓰일 뿐 아니라, 공학규모의 CP 장치를 상용규모로 확장하는데 이용 할 수 있다.

해양 환경오염 모니터링을 위한 국가환경시료은행 괭이갈매기(Larus crassirostris) 알 시료 채취 절차 (Sampling Procedure of Black-tailed Gull (Larus crassirostris)'s eggs in National Environmental Specimen Bank for Monitoring Long-term Marine Environmental Pollution)

  • 이장호;이종천;이상희;김명진;이유진;한아름
    • 환경영향평가
    • /
    • 제22권6호
    • /
    • pp.745-751
    • /
    • 2013
  • Environmental Specimen Banks (ESBs) have been established widely in the world since 1979 for monitoring long-term bio-accumulation of environmental pollutants. The ESBs perform the retrospective analysis of representative biological samples collected regularly and store them in cryogenic condition. In Korea, National Environmental Specimen Bank (NESB) was established in 2009. Since then, NESB had prepared the standard operating procedures (SOPs) for the seven kinds of specimens (Red Pine (Pinus densiflora), Common Carp (Cyprinus carpio), and etc.) for monitoring the effect of environmental pollution on the terrestrial ecosystem and river ecosystem. In 2012, NESB added Black-tailed Gull (Larus crassirostris)'s eggs to the list of the environmental specimen for monitoring marine environmental pollution. In this study, we sampled the eggs of the Black-tailed Gull on two islands (Baekryeongdo of the West Sea and Hongdo of the South Sea). Especially, we selected eggs which remained in the early stages of embryo development for certifying the consistent and stable monitoring for environmental pollutants in egg contents. However, it was not considered to classify an order of eggs per clutch in this study. It is known that the concentration variations of pollutants exist among eggs in one clutch. Therefore, it is needed to consider the positions of eggs in the laying sequences to meet the objective of bioaccumulation monitoring. We collected 30 eggs in each site but the amount may be insufficient to achieve storage target (over 2,000 g). Therefore, we need to consider an optimal sampling size.

공연비 변화가 MILD 연소 특성에 미치는 영향에 관한 해석적 연구 (A numerical study of the air fuel ratio effect on the combustion characteristics in a MILD combustor)

  • 하지수;김태권;심성훈
    • 대한환경공학회지
    • /
    • 제32권6호
    • /
    • pp.587-592
    • /
    • 2010
  • 연소과정 중에 발생하는 질소산화물을 저감하는 기술인 MILD 연소에 대하여 공연비를 변화시키면서 나타나는 연소 특성을 수치해석을 통하여 연구하였다. 작은 크기의 공기분출속도(10 m/s)에서는 공기가 연소로 내 상부영역까지 침투하지 못한다. 반면에 공기분출속도가 30 m/s인 경우에는 공기유동이 연료유동을 억제하고 상부영역까지 흘러간다. 이론공기량에 해당하는 공기분출속도 18 m/s에서는 10 m/s 보다 상대적으로 상부영역까지 침투하였다. 이러한 유동 양상으로 공기분출속도가 작은 10 m/s에서는 연소반응대가 공기노즐 측에 치우쳐 나타나고 30 m/s에서는 연료노즐 측에 형성되었다. 공기분출속도 16, 18, 20 m/s에서는 공기노즐과 연료노즐 중간 영역에서 연소반응대가 형성되었다. 연소로 내 최대온도와 NOx 생성은 공기분출속도가 10 m/s, 30 m/s인 경우 보다 이론공기량이거나 이에 가까운 16, 18, 20 m/s에서 낮게 나타났다. 본 연구로부터 MILD 연소로에서 이론공기량 조건이 NOx를 저감하는 최적의 조건이라는 것을 밝혔다.

부탄가스 증기운폭발의 피해범위에 영향을 미치는 변수에 관한 고찰 (The 'Consequence Analysis' of Variables Affecting the Extent of Damage Caused by Butane Vapor Cloud Explosions)

  • 차순철;추광호
    • 한국가스학회지
    • /
    • 제5권4호
    • /
    • pp.1-7
    • /
    • 2001
  • 본 연구는 플랜트에서 일반적으로 사용하는 서장탱크에서 Heavy가스의 누출에 의한 증기운폭발사고에 대한 영향평가방법을 제시하고 변수의 최적선택조건을 얻기 위하여 부탄저장용기의 누출사고에서 증기운폭발에 대한 사고결과를 평가하고 사고결과에 미치는 변수의 영향을 분석하였다. 이 때 증기운폭발에서 지표면과 일정한 높이에서 연속 누출하여 분산되는 경우에 대하여 $SuperChems^{TM}$ Professional Edition을 사용하여 기상변수와 공정변수들의 변화에 대한 영향을 분석하였다 실제의 조업조건을 표준조건으로 하여 부탄이 저장탱크에서 15분 동안 누출되는 경우에 대하여 사고결과를 산출하고 해석한 결과 연소하한농도(LFL)의 최대거리가 52m이었고. 증기운폭발에 의한 생성된 과압이 128.2m에서 1 psi를 나타내었다. 부탄저장용기의 누출사고 결과에 미치는 변수의 영향 정도는 다소 차이가 있었으나 대기안정도, 바람속도, 배관의 크기, 관심거리 등이었으며, 이들 변수들의 값의 변화에 따라 사고 결과값의 변화가 크게 나타났으며 관심거리가 짧을수록, 누출공의 크기가 클수록 사고에 미치는 영향이 증가하고, 사고결과에 따른 피해범위가 크게 나타났다. 바람속도가 느릴수록, 대기의 상태가 안정한 상태일수록 연소하한농도에 이르는 거리가 증가하고 사고결과가 크게 나타났으며 사고결과에 미치는 변수들의 영향도 증가하였다. 따라서 부탄과 같은 Heavy가스의 저장용기에서의 누출사고에 의한 사고결과에 영향을 미치는 변수들의 영향분석을 바탕으로 영향평가방법을 제시하고 사고결과에 영향을 미치는 중요변수를 선정하고 변수들의 최적선택조건을 얻기 위하여 적절한 변수 값들을 선택하는 기준을 제시하였고 사고결과를 정확한 방법에 의하여 평가하고 예측할 수 있도록 하였다.하며, $31\%$가 한국인 약사에게 건강관리를 의존하는 것으로 나타나 미국사회의 의료 서비스 접근도는 극히 취약한 것으로 드러났다. 의료서비스 접근을 막는 주요 장벽으로는 비싼 의료비 $(53\%)$ , 의사소통장애$(37\%)$로 나타났다. 보건의료 서비스를 위해 주로 이용하며 생활의 정보를 얻는 통로로는 한국어 신문$(69\%)$과 한국어 TV$(61\%)$, 한국어 라디오 $(57\%)$로 밝혀졌다. 결론적으로 한국 이민자들에게 좀더 나은 의료 서비스 수혜를 위해서는 문화 친밀도가 높은 의료환경 조성 및 의료 서비스 제공자들의 이해를 높이는 일 등과 함께 한국 이민자들이 의료보험을 살수 있도록 한국어로 된 의료 서비스 정보를 제공하는 등의 노력이 필요할 것으로 생각한다. 열등한 위치에 있는 여성층과 초기 이민 적응에 가장 문제를 일으킬 소지가 있는 노년층을 들 수 있겠다. 이 연구는 몇 가지 제한점을 가진다. 첫째. 연구 대상자 선정이 어려워서 자원자를 대상으로 연구가 행해졌다. 둘째. 적은 수의 연구 대상자를 대상으로 연구가 행해졌다. 셋째. 연구기간이 짧았던 까닭에 좀더 상세한 사례 연구가 이루어질 수 없었다 좀 더 신뢰할 수 있는 표본 추출 방법을 통하여 선정된, 많은 연구 대상자를 가지고, 심도 있는 연구가 추후 반복적으로 이루어져야 할 것이다.더욱 더 발전을 거듭하고 있으며, 외식은 여행과 여가 활동의 필수적인 요소로써 그 역할을 일조하고 있다. 이와 같은 여가시간의 증가는 독신자들에게는 좀더 많은 여유시간을 가족을 이루고 있는 가족구성원들에게는 가족과의 유대를 강화하는 휴식과 오락의 소비 트렌드를 창출시켰다. 이와 더불어 외식은 식사를

  • PDF

개조된 케이슨 플로팅 도크의 구조 보강에 대한 연구 (A Study on the Structural Reinforcement of the Modified Caisson Floating Dock)

  • 김홍조;서광철;박주신
    • 해양환경안전학회지
    • /
    • 제27권1호
    • /
    • pp.172-178
    • /
    • 2021
  • 선박 수리시장은 선박에 의한 환경오염 방지 강화, 선박구조에 대한 안전기준 강화 등의 영향으로 유지 및 보수에 관한 관심이 꾸준히 증대되고 있다. 이러한 영향을 반영하여 서남해에 있는 수리 조선사들에 외국 선사들의 수리 요청 접수 건수가 증가하고 있다. 그러나, 서남해권 수리 조선사들은 영세한 중소업체가 대부분이라서 수리조선 업체의 통합적 시너지 효과로 이어지기가 쉽지 않고, 집적화가 되어있지 않아서 인프라 공동활용이 어려워서 수리조선업 활성화에 걸림돌로 작용하고 있다. 수리조선업을 운영하기 위해서는 플로팅 도크가 필수적으로 필요로 하며, 대부분 노후화된 케이슨 도크를 해외로부터 수입한 후, 개/보수를 통하여 운용하고 있다. 그러나, 사용 수명이 30년 이상이고, 구조물 검사 기준이 없어서 안전분야에 취약성을 갖고 있다. 본 연구에서는 개조된 케이슨 도크의 구조 안전성을 평가하고, 도출된 문제점을 해결하기 위하여 추가적인 구조 보강안을 찾기 위하여 유한요소해석 프로그램인 ANSYS를 활용하였다. 플로팅 도크의 경우, 선급 규정이 있지만 구조강도 관련해서는 규정이 미흡하여 적용성이 떨어지고 있는 실정이다. 이러한 부족한 평가 영역에 대해서는 상세 구조해석을 통하여 보완하였다. 보강안은 수리조선소 작업의 특성을 고려하여 폰툰 갑판 상부 보강과 선측 탱크 보강으로 결정하였다. 결정안에 대한 구조해석을 통하여 선측 보강안을 최종안을 선정하였고, 실제 구조물을 제작하여 보강안을 반영하였다. 도출된 주요 결과들은 유사 설비의 구조 강도 개선을 위한 참고 자료로 활용 가능하며, 개/보수 시 이러한 방법을 활용하면 빨리 최적 해를 찾을 수 있을 것으로 기대된다.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF